• Title/Summary/Keyword: Miniature heat pipe

Search Result 14, Processing Time 0.021 seconds

An Analytical Model for Predicting the Effective Thermal Conductivity of Woven Wire Wick Structure

  • Lee, Jin-Sung;Kim, Chul-Ju
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.10 no.2
    • /
    • pp.72-78
    • /
    • 2002
  • Woven wire wick is a very effective structure because of its easiness to insert inside of pipe for a miniature heat pipe. The present study was conducted to predict the porosity and the effective thermal conductivity of liquid-saturated woven wire wick. The porosity and the effective thermal conductivity of the evaporator region indicate different values from those of the condenser region due to the existence of non-flow region. The minimum value of the effective thermal conductivity indicates on condition of the $\theta$=$45^{Wcirc}$ and the values of the effective thermal conductivity increases symmetrically centering around the minimum value. The values of the effective thermal conductivity in the evaporator region at the angle of $45^{Wcirc}$ indicate about 60~80% higher than those in the condenser region for various combinations of copper, and stainless with water and ethanol.

Experimental Investigation on Thermal Characteristics of Heat Pipes Using Water-based MWCNT Nanofluids (물 기반 탄소나노튜브 나노유체 히트파이프의 열적 특성에 관한 실험적 해석)

  • Ha, Hyo-Jun;Kong, Yu-Chan;Do, Kyu-Hyung;Jang, Seok-Pil
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.7
    • /
    • pp.528-534
    • /
    • 2011
  • In this paper, thermal characteristics of cylindrical grooved wick heat pipes with water-based MWCNT nanofluids as working medium are experimentally investigated. Volume fractions of nanoparticles are varied with 0.1% to 0.5%. Transient hot wire method developed in house is used to measure the thermal conductivity of nanofluids. It is enhanced by up to 29% compared to that of DI water. The thermal resistances and temperature distributions at the surface of the heat pipes are measured at the same evaporation temperature. The experimental results show that the thermal resistance of the heat pipes with water-based MWCNT nanofluids as working fluid is reduced up to 35.2% compared with that of heat pipe using DI water. The reduction rate of thermal resistance is greater than the enhancement rate of thermal conductivity. Finally, based on the experimental results, we present the reduction of the thermal resistances of the heat pipes compared with conventional heat pipes cannot be explained by only the thermal conductivity of water-based MWCNT nanofluids.

A Study on Operating Characteristics and Development of Woven-Wired Wick Heat Pipe (편조 윅 히트파이프의 개발과 작동특성에 관한 연구)

  • Moon, Seok-Hwan;Choi, Choon-Gi;Hwang, Gunn;Choy, Tae-Goo
    • Journal of Energy Engineering
    • /
    • v.9 no.1
    • /
    • pp.54-59
    • /
    • 2000
  • 전자부품 및 시스템의 고속/고밀도화 추세에 따라 발열밀도가 계속증가하고 있다. 최근 팬티엄 II 급이상의 노트북 컴퓨터의 CPU에서는 칩당 발열량이 10W 이상으로 증가하고 있고 패키징 공간의 제한 때문에 소형히트파이프를 이용한 냉각이 많이 적용되고 있다. 본 연구에서는 모세압구동력이 크고 생산성등이 고려된 편조 형태의 새로운 윅을 개발하였으며 , 노트북 컴퓨터의 CPU 등 소형 전자부품냉ㄱ가에 적용가능한 직경 3, 4 mm 히트파이프를 설계 및 제작하였다. 직경 3, 4 mm Miniature Heat Pipe (이하 MHP) 의 작동특성은 일반적인 중형히트파이프와 다르므로 MHP 의 열전달 특성 및 작동성능에 미치는 각종 인자들의 영향을 파악하고자 성능시험을 수행하였다. 고려된 작동인자로는 작동유체 충전률, 전체 파이프길이 및 증발부, 응축부길이, 설치 경사각, 윅의 가닥수, 열부하 등이다. 작동인자의 영향과 관련된 연구결과는 향후 패키징을 위한 응용연구의 기초자료로 활용할 수 있을 것이다.

  • PDF

Operational Characteristics for a Miniature Heat Pipe with a V-shaped Groove Wick (V형 그루브윅을 갖는 소형 히트파이프의 작동특성)

  • 강환국;김철주;홍성은
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1999.05a
    • /
    • pp.197-205
    • /
    • 1999
  • 소형 히트파이프에서 ?을 구리망사 또는 그루브를 적용할 수 있고 그루브 형상은 U, V 등 다양하다. 망사?은 모세압이 큰 잇점이 있어나 제작 단가가 높다. 그루브?은 대량생산이 용이하나 전밀 가공 기술이 요구된다. 현재까지 국내에서는 노트북 PC의 CPU 냉각에 사용한 소형 히트파이프의 전량을 해외에서 구매하고 있다. 본 연구에서는 직경 7 mm U형 그루브 관을 인발하여 관직경을 축소한 결과 내경 3.6 mm의 외경 4mm 의 V형 그루브관을 얻을 수 있었다. 이 관을 이용하여 소형 히트파이프를 제작하고 열전달 성능 시험을 수행하였다. 열전달 한계는 40~6$0^{\circ}C$ 범위작동온도 경사각 0$^{\circ}$ 에서 3 W를 얻을 수 있었다. U형 그루브 히트파이프에 비하여 모세압 저하로 인하여 낮은 값을 나타내었다. 열저항을 약 0.7~l.3 $^{\circ}C$/W 로 U형 그루브와 유사하였다.