• 제목/요약/키워드: Mineral Detection

검색결과 199건 처리시간 0.022초

3차원 전기비저항탐사에 의한 석회암 공동탐지 (Detection of Limesilicate Cavities by 3-D Resistivity Survey)

  • 박삼규;이명종;김창렬;손정술;김정호;조성준;서구원
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 춘계 학술발표회 논문집
    • /
    • pp.147-152
    • /
    • 2006
  • In this study, we examined the applicability of three-dimensional electrical resistivity survey to detect underground cavities of ground subsidence area at the field test site, located at Yongweol-ri, Muan-gun in Korea. Underground cavities are widely present within the limesilicate bedrock overlain by the alluvial deposits in the area of the test site where the ground subsidences have occurred in the past. The limesilicate cavities are mostly filled with groundwater and clays in the test site. Thus, cavities have low electrical resistivity compared to the surrounding host bedrock. The results of the study have shown that the zones of low resistivity correspond to the zones of the cavities identified in the boreholes at the site, and that the three-dimensional electrical resistivity survey used are very effective to detect underground cavities.

  • PDF

3차원 전기비저항탐사에 의한 카르스트 지역에서의 공동탐지 (Detection of cavities in a karst area by means of a 3D electrical resistivity technique)

  • 박삼규;김창렬;손정술;이명종;김정호
    • 지구물리와물리탐사
    • /
    • 제12권1호
    • /
    • pp.27-32
    • /
    • 2009
  • 이 연구는 한국 남서쪽에 위치한 무안군 용월리의 카르스트 지역에서 지하 공동 탐지를 위하여 3차원 전기비저항탐사의 적용성을 시험한 것이다. 현장 조사지역은 과거에 지반침하가 발생하였으며, 지하 공동은 충적층 하부에 분포하고 있는 석회암내에서 발견된다. 석회암 공동은 대부분 지하수와 점성토로 충진 되어 있기 때문에 주변의 기반암에 비하여 전기비저항이 상대적으로 낮게 나타난다. 이 연구 결과에 의하면 시추공에서 인식되고 있는 공동 분포대가 저비저항대와 일치하고 있으며, 이로부터 3차원 전기비저항탐사가 카르스트 지역에서의 지하 공동을 탐지하고 영상화 하는데 매우 유용함을 입증했다.

A Study on the Analytical Methods Using Solid-phase Extraction for the Determination of Phenols in Water

  • Jeon, Chi-Wan;Lee, Jung-Hwa;Lee, Sang-Hak
    • 한국환경과학회:학술대회논문집
    • /
    • 한국환경과학회 2003년도 International Symposium on Clean Environment
    • /
    • pp.135-138
    • /
    • 2003
  • Based on solid phase extraction, gas chromatography and mass spectrometry procedure for determining phenol and its derivatives in natural water was presented. In solid phase extraction, three types of techniques using solid phase adsorption material were treated with acid and salt, and converted second portion of acetyl derivatives. Under the these condition, extraction efficiency and detection ability dependent on extraction methods were discussed. Obtained results using optimized solid phase extraction techniques showed more convenience, simplifier and lower cost than the conventional analytical methods with holding wide dynamic range and lower detection limits.

  • PDF

형광(螢光)을 이용한 식품(食品) 방부제의 검사(檢査) (Detection of Chemical Preservatives by the Use of Fluorescence)

  • 이미순
    • 한국식품과학회지
    • /
    • 제11권3호
    • /
    • pp.166-170
    • /
    • 1979
  • UVSL-25 mineral light를 조사(照射)한 경우에 발생하는 식품(食品) 보존료(保存料) 자체(自體)의 형광(螢光)을 이용하여 신속하고 간편하게 보존료(保存料)를 검사(檢査)할 수 있는 방법(方法)을 시도(試圖)하였다. 유동(流動) 파라핀에 현탁(懸濁)된 분말(粉末) 시료(試料)의 흡수(吸收) 및 발광(發光) 스펙트럼은 보존료(保存料)의 종류에 따라 특징적인 패턴을 나타냈다. 장파장(長波長) 측(側) 및 단파장(短波長) 측(側) 영역(領域)의 자외선(紫外線) 조사(照射)에서 얻은 스펙트럼 특성을 대조(對照)하여 비교하므로써 보존료(保存料)의 종류가 보다 용이하게 판별되었다.

  • PDF

Iterative Error Analysis 기반 분광혼합분석에 의한 초분광 영상의 표적물질 탐지 기법 (Hyperspectral Target Detection by Iterative Error Analysis based Spectral Unmixing)

  • 김광은
    • 대한원격탐사학회지
    • /
    • 제33권5_1호
    • /
    • pp.547-557
    • /
    • 2017
  • 본 연구에서는 탐지하고자 하는 표적신호를 초기 엔드멤버로 하여 Iterative Error Analysis를 통해 배경물질들의 반사 스펙트럼을 순차적으로 엔드멤버로 추출하고, 추출된 엔드멤버들을 이용하여 분광 혼합분석함으로써 표적물질의 분포를 탐지하는 새로운 초분광 표적탐지 기법을 제안한다. 제안된 기법에서는 표적물질에 대한 점유율의 변화가 주어진 문턱값보다 작아질 때 엔드멤버 추출을 위한 반복을 멈추게 된다. 이 기법은 Orthogonal Subspace Projection과 같은 모델 기반 표적 탐지기법들과 달리 사전에 엔드멤버들을 확보해야 할 필요가 없으며, Matched Filter와 같은 확률론적 표적 탐지 기법들과 달리 배경 전체를 하나의 신호로 특징화하지 않기 때문에 표적의 희소성 여부에 의한 영향을 받지 않는다는 장점을 가지고 있다. 실제 항공 초분광 영상자료 및 다양한 인공 표적물질들이 삽입된 모의 초분광 영상자료를 이용한 실험 결과, 제안된 방법이 희소 및 비 희소 표적의 탐지에 매우 효과적임이 확인되었다. 제안된 방법은 표적 물체 탐지뿐만 아니라 광물, 오염물질 등 자원 및 환경 분야에서 다양한 피복 물질을 탐지하는데 효과적으로 사용될 수 있을 것으로 기대된다.

Electrical resistivity survey and interpretation considering excavation effects for the detection of loose ground in urban area

  • Seo Young Song;Bitnarae Kim;Ahyun Cho;Juyeon Jeong;Dongkweon Lee;Myung Jin Nam
    • Geomechanics and Engineering
    • /
    • 제35권2호
    • /
    • pp.109-119
    • /
    • 2023
  • Ground subsidence in urban areas due to excessive development and degraded underground facilities is a serious problem. Geophysical surveys have been conducted to estimate the distribution and scale of cavities and subsidence. In this study, electrical resistivity tomography (ERT) was performed near an area of road subsidence in an urban area. The subsidence arose due to groundwater leakage that carried soil into a neighboring excavation site. The ERT survey line was located between the main subsidence area and an excavation site. Because ERT data are affected by rapid topographic changes and surrounding structures, the influence of the excavation site on the data was analyzed through field-scale numerical modeling. The effect of an excavation should be considered when interpreting ERT data because it can lead to wrong anomalous results. A method for performing 2D inversion after correcting resistivity data for the effect of the excavation site was proposed. This method was initially tested using a field-scale numerical model that included the excavation site and subsurface anomaly, which was a loosened zone, and was then applied to field data. In addition, ERT data were interpreted using an existing in-house 3D algorithm, which considered the effect of excavation sites. The inversion results demonstrated that conductive anomalies in the loosened zone were greater compared to the inversion that did not consider the effects of excavation.

Application of an Energy Sensitive CZT Detector to a DXA Type of Bone Densitometer

  • Yoon, Je-Woong;Lee, Hyung-Koo;Lee, Heung-Kyu
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.422-424
    • /
    • 2002
  • The accuracy of DXA(Dual Energy X-ray Absorptiometry) highly depends on the detection and separation capability of dual energy X-ray X-ray photons. In addition both of scan time and patient exposure are affected by detection efficiency. A CZT detector with a good energy resolution and high detection efficiency was evaluated for the application of bone densitometry. Its performance was compared to a photomultiplier tube with a NaI(T1) scintillator in terms of energy resolution, detection efficiency and the accuracy of bone mineral density measurement. The comparison study was performed with CZT detector and PM tube using DXA equipments(OSTEO Plus, OSTEO Prima, ISOL Technology). The energy spectrum was acquired using MCA(Multi-Channel Analyzer). The used X-ray energy ranged from 20keV to 86keV. The MCA result of the CZT detector showed a slightly sharper energy spectrum than that of NaI(T1). Detection efficiency of the CZT detector at 59.5keV was 1.4 times better. Remarkably the final results of bone mineral density measurements demonstrate only less than 1% difference. The CZT detector appears to have many benefits for the application of bone densitometry. Its excellent energy resolution can enhance the counting accuracy of dual energy X-ray spectrum. Furthermore its compactness in physical dimension and no cooling requirement will be additional benefits for a more compact and accurate bone densitometer.

  • PDF

Detection of Thermal Effluent Discharged from Nuclear Power Plant Using Airborne MSS and Landsat ETM+

  • Han, Joung-Gyu;Chi, Kwang-Hoon;Yeon, Young-Kwang
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2002년도 Proceedings of International Symposium on Remote Sensing
    • /
    • pp.323-329
    • /
    • 2002
  • The thermal effluent discharged from nuclear power plants can affect the offshore ecosystem change. The ability of measuring sea surface temperature in high resolution with Airborne MSS thermal spectral band(8.5 $\mu$m ~ 12.5 $\mu$m) and Landsat ETM+(10.4$\mu$m ~ 12.5 $\mu$m) gives us an information of spread range of thermal effluent. This information can be used as one of major factors fur analyzing the impact of the fish farm damage around the nuclear power plants. Every season from November 1999, this research has been conducted to investigate the extent of diffusion of thermal effluent discharged from KoRi, UlJin and WolSung Nuclear Power Plant located at the coastline of the East Sea of Korea.

  • PDF

CHANGE DETECTION OF LAND COVER ENVIRONMENT IN THE HAMPYEONG-BAY, KOREA USING LANDSAT DATA

  • Lee Hong-Jin;Chi Kwang-Hoon;Jang Se-Won
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2005년도 Proceedings of ISRS 2005
    • /
    • pp.402-402
    • /
    • 2005
  • The purpose of this study is to analyze the land cover environment changes of tidal flat in the Hampyeong Bay. Especially, it centers on the changes in the sedimentary environment using remote sensing data. Multi-temporal Landsat data (Path-Row: 116-034) were used in this study. Remote sensing data can be effectively applied for quantitative analysis of geological environment changes in the Hampyeong-bay.

  • PDF

Extraction Characteristics and Quantitational Methods for Total Petroleum Hydrocarbons in Soil

  • Jeon, Chi-Wan;Lee, Jung-Hwa;Song, Kyung-Sun;Lee, Sang-Hak;Lee, Jung-Min
    • 한국환경과학회:학술대회논문집
    • /
    • 한국환경과학회 2003년도 International Symposium on Clean Environment
    • /
    • pp.119-122
    • /
    • 2003
  • Quantitation methods of total petroleum hydrocarbons to determinate oil contaminated level in soil were discussed. Extraction characteristics of several pretreatment methods and practical detection limit and reappearances in gas chromatography/mass spectrometry. with each pretreatment method were investigated. The obtained results showed that the newly adopted quantitation method and mechanical shaking extraction method using methanol with extraction solvent are more practical and applicable to real sample than the conventional methods. In applying these methods to gasoline, kerosene, fuel oil which are major source of soil contamination, the practical quantitation limit and % relative standard deviation was able to determine with range of 2.5 - 10 ppm, 5 - 7 %.

  • PDF