• 제목/요약/키워드: Millimeter Scale

검색결과 46건 처리시간 0.021초

미세 연소기 개발 (II) - 미세동력 장치용 미세 전극의 제작과 성능평가 - (Design and Development of Micro Combustor (II) - Design and Test of Micro Electric Spark discharge Device for Power MEMS -)

  • 권세진;이대훈;박대은;윤준보;한철희
    • 대한기계학회논문집B
    • /
    • 제26권4호
    • /
    • pp.524-530
    • /
    • 2002
  • Micro electric spark discharge device was fabricated on a FOTURAN glass wafer using MEMS processing technique and its performance of electron discharge and subsequent formation of ignition kernel were tested. Micro electric spark device is an essential subsystem of a power MEMS that has been under development in this laboratories. In a combustion chamber of sub millimeter scale depth, spark electrodes are formed by electroplating Ni on a base plate of FOTURAN glass wafer. Optimization of spark voltage and spark gap is crucial for stable ignition and endurance of the electrodes. Namely, wider spark gaps insures stable ignition but requires higher ignition voltage to overcome the spark barrier. Also, electron discharge across larger voltage tends to erode the electrodes limiting the endurance of the overall system. In the present study, the discharge characteristics of the proptotype ignition device was measured in terms of electric quantities such as voltage and currant with spark gap and end shape as parameters. Discharge voltage shows a little decrease in width of less than 50㎛ and increases with electrode gap size. Reliability test shows no severe damage over 10$\^$6/ times of discharge test resulting in satisfactory performance for application to proposed power MEMS devices.

KVN single-dish survey of the MALATANG galaxies

  • Poojon, Panomporn;Chung, Aeree;Lee, Bumhyun;Baek, Junhyun;Jung, Taehyun;Sohn, Bong Won;Oh, Se-Heon;Sengupta, Chandreyee
    • 천문학회보
    • /
    • 제43권1호
    • /
    • pp.57.2-57.2
    • /
    • 2018
  • We present the preliminary result from our KVN single-dish observations of the MALATANG sample. The MALATANG (Mapping the dense molecular gas in the strongest star-forming Galaxies) is one of the JCMT legacy surveys on the nearest 23 IR-brightest galaxies beyond the Local Group. The goal of the MALATANG survey is to map the sample in the dense gas tracers (HCN and HCO+J=4-3), and probe the relationships between the dense molecular gas and star formation activities. As a complementary study, we recently launched a KVN/KaVA program on the same sample, in order to measure their flux densities and parsec-scale jet/outflows in the millimeter regime, which will be greatly useful in understanding the initial conditions of the feedback process. In this work, we present the preliminary result from our pilot KVN single-dish program on a sub-sample, which will be used to select the future VLBI imaging study under plan. We investigate the KVN spectral energy distributions (SED) of the sample as a function of the power source of the luminous IR brightness of each target (starburst? AGN? or hybrid?). We also discuss the technical challenges that we experienced during our KVN observations due to the large size of the sample in the sky.

  • PDF

Use of an Optical Scanning Device to Monitor the Progress of Noninvasive Treatments for Chest Wall Deformity: A Pilot Study

  • Kelly, Robert E. Jr.;Obermeyer, Robert J.;Kuhn, M. Ann;Frantz, Frazier W.;Obeid, Mohammad F.;Kidane, Nahom;McKenzie, Frederic D.
    • Journal of Chest Surgery
    • /
    • 제51권6호
    • /
    • pp.390-394
    • /
    • 2018
  • Background: The nonsurgical treatment of chest wall deformity by a vacuum bell or external brace is gradual, with correction taking place over months. Monitoring the progress of nonsurgical treatment of chest wall deformity has relied on the ancient methods of measuring the depth of the excavatum and the protrusion of the carinatum. Patients, who are often adolescent, may become discouraged and abandon treatment. Methods: Optical scanning was utilized before and after the intervention to assess the effectiveness of treatment. The device measured the change in chest shape at each visit. In this pilot study, patients were included if they were willing to undergo scanning before and after treatment. Both surgical and nonsurgical treatment results were assessed. Results: Scanning was successful in 7 patients. Optical scanning allowed a visually clear, precise assessment of treatment, whether by operation, vacuum bell (for pectus excavatum), or external compression brace (for pectus carinatum). Millimeter-scale differences were identified and presented graphically to patients and families. Conclusion: Optical scanning with the digital subtraction of images obtained months apart allows a comparison of chest shape before and after treatment. For nonsurgical, gradual methods, this allows the patient to more easily appreciate progress. We speculate that this will increase adherence to these methods in adolescent patients.

해양조석하중에 의한 지각변위 분석 (ANALYSIS OF CRUSTAL DEFORMATION DUE TO OCEAN TIDE LOADING)

  • 박관동;원지혜;김호균;임관창
    • Journal of Astronomy and Space Sciences
    • /
    • 제24권3호
    • /
    • pp.249-260
    • /
    • 2007
  • 한반도에서 발생하는 해양조석하중(OTL, Ocean Tide Leading)에 의한 지각변위는 수직방향으로 최대 ${\sim}3cm$에 달한다. 현재 우주측지 기술로 성취할 수 있는 측위 정확도가 mm수준임을 고려할 때, cm 단위로 발생하는 OTL 지각변위 영향은 정밀하게 모델링하고 측위 시 보정해야할 대상이다. 이 연구에서는 먼저 OTL 지각변위 보정에 필요한 해양조석 모델들을 서로 비교하고 OTL 지각변위 예측 프로그램을 검증하였다. 경기만 지역의 경우 해양조석 모델에 따라 ${\sim}6mm$ RMS의 수직성분 지각변위 차이가 발생하였다. VLBI 천문대가 설치되는 서울, 울산, 서귀포에서의 OTL 지각변위를 분석한 결과 서귀포는 ${\sim}3.5cm$, 서울과 울산은 ${\sim}2cm$ 진폭의 수직방향 지각변위가 예측되었다. 또한 GPS 자료 처리에서 OTL 지각변위 영향을 보정하지 않았을 경우 GPS Zenith Wet Delay(ZWD) 추정 값이 달라졌으며, OTL 지각변위와 ZWD간의 배율인자(scale facto.)는 3.72로 나타났다.

Modern Paper Quality Control

  • Olavi Komppa
    • 한국펄프종이공학회:학술대회논문집
    • /
    • 한국펄프종이공학회 2000년도 제26회 펄프종이기술 국제세미나
    • /
    • pp.16-23
    • /
    • 2000
  • The increasing functional needs of top-quality printing papers and packaging paperboards, and especially the rapid developments in electronic printing processes and various computer printers during past few years, set new targets and requirements for modern paper quality. Most of these paper grades of today have relatively high filler content, are moderately or heavily calendered , and have many coating layers for the best appearance and performance. In practice, this means that many of the traditional quality assurance methods, mostly designed to measure papers made of pure. native pulp only, can not reliably (or at all) be used to analyze or rank the quality of modern papers. Hence, introduction of new measurement techniques is necessary to assure and further develop the paper quality today and in the future. Paper formation , i.e. small scale (millimeter scale) variation of basis weight, is the most important quality parameter of paper-making due to its influence on practically all the other quality properties of paper. The ideal paper would be completely uniform so that the basis weight of each small point (area) measured would be the same. In practice, of course, this is not possible because there always exists relatively large local variations in paper. However, these small scale basis weight variations are the major reason for many other quality problems, including calender blacking uneven coating result, uneven printing result, etc. The traditionally used visual inspection or optical measurement of the paper does not give us a reliable understanding of the material variations in the paper because in modern paper making process the optical behavior of paper is strongly affected by using e.g. fillers, dye or coating colors. Futhermore, the opacity (optical density) of the paper is changed at different process stages like wet pressing and calendering. The greatest advantage of using beta transmission method to measure paper formation is that it can be very reliably calibrated to measure true basis weight variation of all kinds of paper and board, independently on sample basis weight or paper grade. This gives us the possibility to measure, compare and judge papers made of different raw materials, different color, or even to measure heavily calendered, coated or printed papers. Scientific research of paper physics has shown that the orientation of the top layer (paper surface) fibers of the sheet paly the key role in paper curling and cockling , causing the typical practical problems (paper jam) with modern fax and copy machines, electronic printing , etc. On the other hand, the fiber orientation at the surface and middle layer of the sheet controls the bending stiffness of paperboard . Therefore, a reliable measurement of paper surface fiber orientation gives us a magnificent tool to investigate and predict paper curling and coclking tendency, and provides the necessary information to finetune, the manufacturing process for optimum quality. many papers, especially heavily calendered and coated grades, do resist liquid and gas penetration very much, bing beyond the measurement range of the traditional instruments or resulting invonveniently long measuring time per sample . The increased surface hardness and use of filler minerals and mechanical pulp make a reliable, nonleaking sample contact to the measurement head a challenge of its own. Paper surface coating causes, as expected, a layer which has completely different permeability characteristics compared to the other layer of the sheet. The latest developments in sensor technologies have made it possible to reliably measure gas flow in well controlled conditions, allowing us to investigate the gas penetration of open structures, such as cigarette paper, tissue or sack paper, and in the low permeability range analyze even fully greaseproof papers, silicon papers, heavily coated papers and boards or even detect defects in barrier coatings ! Even nitrogen or helium may be used as the gas, giving us completely new possibilities to rank the products or to find correlation to critical process or converting parameters. All the modern paper machines include many on-line measuring instruments which are used to give the necessary information for automatic process control systems. hence, the reliability of this information obtained from different sensors is vital for good optimizing and process stability. If any of these on-line sensors do not operate perfectly ass planned (having even small measurement error or malfunction ), the process control will set the machine to operate away from the optimum , resulting loss of profit or eventual problems in quality or runnability. To assure optimum operation of the paper machines, a novel quality assurance policy for the on-line measurements has been developed, including control procedures utilizing traceable, accredited standards for the best reliability and performance.

휘어진 경계에서의 좁은 영역에 대한 Radiochromic 필름 도시메트리 평가 (Evaluation of the Radiochromic Film Dosimetry for a Small Curved Interface)

  • 강세권;박소아;황태진;정광호;한태진;김해영;이미연;김경주;배훈식
    • 한국의학물리학회지:의학물리
    • /
    • 제23권4호
    • /
    • pp.234-238
    • /
    • 2012
  • 눈꺼풀에 발생한 종양의 치료를 위해서는 종종 고에너지 전자선이 이용되며, 이 경우 환자의 시력 보호를 위해 금속차폐체를 눈꺼풀과 안구 사이에 삽입하고 방사선 치료를 시행한다. 차폐체에 접한 눈꺼풀 안쪽의 방사선량 확인을 위해서는 매우 작은 측정도구가 필요하며, 굽은 경계면의 특성상 유연한 측정도구가 바람직한데, radiochromic 필름 도시메트리는 이 목적에 매우 적합하다. 작으면서도 휘어진 경계면을 따라서 선량을 측정하기 위해, 눈꺼풀 팬텀과 차폐체 사이에 3-mm 폭의 EBT2 필름 띠를 삽입하고, 6MeV의 전자선을 조사 후, 선량분포를 얻었다. 금속차폐체와 동일한 크기로 아크릴 재질의 차폐체를 제작하여, 금속인공영상물이 없는 CT 영상을 얻은 후, 이를 이용하여 몬테칼로 전산모사를 수행하였다. 전산모사에서는 실제 안구차폐체의 재질을 따라 텅스텐, 알루미늄 및 스테인레스 스틸 등의 물질 정보를 이용하였다. 이렇게 얻은 전산모사 결과는 필름 측정과 2.1% 내에서 일치하였다. 밀리미터 크기 정도로 작고 또한 휘어진 영역에서 radiochromic 필름 도시메트리는 취급도 용이할 뿐만 아니라 만족스런 정확도를 보여주고 있다.