• 제목/요약/키워드: Millimeter Scale

검색결과 46건 처리시간 0.026초

A Wire-overhead-free Reset Propagation Scheme for Millimeter-scale Sensor Systems

  • Lee, Inhee;Bang, Suyoung;Kim, Yejoong;Kim, Gyouho;Sylvester, Dennis;Blaauw, David;Lee, Yoonmyung
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제17권4호
    • /
    • pp.524-533
    • /
    • 2017
  • This paper presents a novel reset scheme for mm-scale sensing systems with stringent volume and area constraints. In such systems, multi-layer structure is required to maximize the silicon area per volume and minimize the system size. The multi-layer structure requires wirebonding connections for power delivery and communication among layers, but the area overhead for wirebonding pads can be significant. The proposed reset scheme exploits already existing power wires and thus does not require additional wires for system-wide reset operation. To implement the proposed reset scheme, a power management unit is designed to impose reset condition, and a reset detector is designed to interpret the reset condition indicated by the power wires. The reset detector uses a coupling capacitor for the initial power-up and a feedback path to hold the developed supply voltage. The prototype reset detector is fabricated in a $180-{\mu}m$ CMOS process, and the measurement results with the prototype mm-scale system confirmed robust reset operation over a wide range of temperatures and voltages.

미세 연소기 개발(I) - 소형 연소기 환경에서의 연소 특성 - (Design and Development of Micro Combustor (I) - Combustion Characteristics in Scale-Downed Combustor -)

  • 이대훈;최권형;권세진
    • 대한기계학회논문집B
    • /
    • 제26권1호
    • /
    • pp.74-81
    • /
    • 2002
  • Combustion phenomena in a sub-millimeter scale combustor have been investigated. To evaluate scale effect on flame propagation characteristics, a cylindrical combustion chamber with variable depth was built in-house. The combustor was charged with premixed gas of hydrogen and air and ignited electronically. A piezo electric pressure transducer recorded transient pressure after the ignition. Measurements were made at different test conditions specified with chamber depth and initial pressure as parameters. Visual observation was made through a quartz glass window on top side of the combustion chamber using high speed digital video camera. From the pressure data, available work was estimated and compared with energy input required for stable ignition. The preliminary results suggested that the net thermal energy release is sufficient to generate power and enables a combustor of the size in the present study to be used as the energy source of a micro power devices .

양성자에 대한 금 나노입자의 밀도에 따른 흡수 에너지의 몬테카를로 전산모사 (Monte Carlo Simulation of Absorbed Energy by Gold Nano-Particles for Proton)

  • 천권수
    • 한국방사선학회논문지
    • /
    • 제18권1호
    • /
    • pp.1-9
    • /
    • 2024
  • 양성자 치료는 브래그 피크로 인해 우수한 치료 기법으로 알려져 있다. 양성자의 치료 효과를 높이기 위해 금 나노입자를 종양에 분포시켜 흡수선량을 높이는 방법이 연구되고 있다. 마이크로미터와 나노미터 범위에서 금 나노입자를 다루었던 것을 밀리미터 범위에서 금 나노입자를 전산모사 할 수 있는 방법을 제시하였다. 전산모사를 위해 Geant4 툴킷을 사용하였다. 인체와 유사한 물과 금 나노입자가 균일하게 분포되어 있다는 것을 가정하고 밀도비를 통해 금 나노입자의 개수 또는 농도를 조절하였다. 브래그 피크 위치에서 밀도비가 5%일 때 금 나노입자로 인해 순수 물 팬텀에 비해 흡수 에너지의 이득이 거의 2배로 나타났다. 밀도비가 증가할수록 흡수 에너지의 이득은 선형적으로 증가하였다. 브래그 피크 위치에서 금 나노입자가 하나의 복셀에만 분포하고 있을 때 양성자의 에너지는 자신 주변의 복셀에만 영향을 미치지만, 넓은 영역에 금 나노입자가 분포하는 경우 순수 물 팬텀에서 최고 흡수 에너지 (9.95 keV)의 95% 흡수 에너지 (9.46 keV)를 나타내는 부피는 16배 큰 영역에서 흡수 에너지의 이득이 나타났다. 그리고 이 영역은 밀도비가 증가할수록 증가하였다. 밀리미터 범위에서 금 나노입자의 밀도비와 RBE의 관계를 정량화하는 등 추가적인 연구가 필요하다.

영상처리를 이용한 정동적 변위 계측과 속도, 가속도 추산방식 연구 (Measurement of Static and Dynamic Displacement by Image Processing and Study for Prediction Method of Velocity and Acceleration)

  • 허석;곽문규;이호범
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2010년도 추계학술대회 논문집
    • /
    • pp.527-532
    • /
    • 2010
  • This paper is concerned with the measurement of static and dynamic displacement by image processing(IP) and study for prediction method of velocity and acceleration. To measure the displacement visually, the measurement system consists of a telephoto zoom camera, ccd image device and a computer. The specific target on the white board is used to calculate the displacement of the structure. The captured image is then converted into a pixel-based data and then analyzed numerically. The limitation of the system depends on the image capturing speed and the pixel-size of image. In this paper, we developed for the displacement measurement using the image processing method. The proposed method enables us to measure the vibration measurement, velocity and acceleration directly without any contact. The current resolution of the displacement measurement is limited to 1/100 millimeter scale.

  • PDF

Demonstration of Adaptive Analogue Beam Forming in the E-Band

  • Dyadyuk, Val;Stokes, Leigh;Nikolic, Nasiha;Weily, Andrew R.
    • Journal of electromagnetic engineering and science
    • /
    • 제10권3호
    • /
    • pp.138-145
    • /
    • 2010
  • In this paper, we report the test results of a small-scale prototype that implements an analogue-beam-formed phased antenna array in the E-band. A four-channel dual-conversion receive RF module for 71~76 GHz frequency band has been developed and integrated with a linear end-fire antenna array. Measured performance is very close to the simulated results. An ad-hoc wireless communication system has also been demonstrated. Low BER was measured for an 8PSK data stream at 1.5 Gbps with the receive array beam formed in the direction of arrival of the transmitted signal. To our knowledge this is the first steerable antenna array reported to date in the E-band.

천체화학과 성간분자 (ASTROCHEMISTRY AND INTERSTELLAR MOLECULES)

  • 민영철
    • 천문학논총
    • /
    • 제25권1호
    • /
    • pp.1-13
    • /
    • 2010
  • Astrochemistry provides powerful tools to understand various cosmic phenomena, including those in our solar system to the large-scale structure of the universe. In addition, the chemical property of an astronomical body is a crucial factor which governs the evolution of the system. Recent progress in astrophysical theories, computational modelings, and observational techniques requires a detailed understanding of the interactions between the constituents of an astronomical system, which are atoms and molecules within the system. Especially the far-infrared/sub-millimeter wave range, which is called as the last frontier in astronomical observations, contains numerous molecular lines, which may provide a huge amount of new information. However, we need an astrochemical understanding to use this information fully. Although this review is very limited, I would like to stress the importance of astrochemical approach in this overview for the field, which is getting much more attention than ever before.

Measurements of Temperature and Flow Fields with Sub-Millimeter Spatial Resolution Using Two-Color Laser Induced Fluorescence (LIF) and Micro-Particle Image Velocimetry (PIV)

  • Kim Hyun Jung
    • Journal of Mechanical Science and Technology
    • /
    • 제19권2호
    • /
    • pp.716-727
    • /
    • 2005
  • Comprehensive measurements for velocity and temperature fields have been conducted. A Micro PIV 2-color LIF system have been setup to measure the buoyancy driven fields in a 1-mm heated channel with low Grashof-Prandtl numbers [$86]. Fluorescence microscopy is combined with an MPIV system to obtain enough intensity images and clear pictures from nano-scale fluorescence particles. The spatial resolution of the Micro PIV system is $75{\mu}m\;by\;67{\mu}m$ and error due to Brownian motion is estimated $1.05\%$. Temperature measurements have achieved the $4.7\;{\mu}m$ spatial resolution with relatively large data uncertainties the present experiment. The measurement uncertainties have been decreased down to less than ${\pm}1.0^{\circ}C$ when measurement resolution is equivalent to $76\;{\mu}m$. Measured velocity and temperature fields will be compared with numerical results to examine the feasibility of development as a diagnostic technique.

Redistribution of an Intergranular-Liquid Phase During Sintering of 1 mol%-Al2O3-doped Calcia-Stabilized Zirconia: Estimation by Impedance Spectroscopy

  • Choi, Jung-Hae;Lee, Jong-Heun;Kim, Doh-Yeon
    • 한국세라믹학회지
    • /
    • 제39권9호
    • /
    • pp.818-821
    • /
    • 2002
  • The grain boundary resistivity of a 1-mol%-$Al_2O_3$-dopedd CaO-Stabilized Zirconia(CSZ) specimen was determined by impedance spectroscopy using sub-millimeter-scale electrodes. At the initial stage of sintering, the grain-boundary resistivity of the specimen interior was observed to be higher than that of the surface. However, upon further sintering the boundary resistivity of the specimen interior became lower than that of the surface. The results were explained in terms of a redistribution of the intergranular liquid phase. The liquid phase was predicted to initially coagulate at the interior of the specimen then spread outward during sintering.

초고추파 집적 회로를 위한 새로운 실리콘 MEMS 패키지 (THe Novel Silicon MEMS Package for MMICS)

  • 권영수;이해영;박재영;김성아
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권6호
    • /
    • pp.271-277
    • /
    • 2002
  • In this paper, a MEMS silicon package is newly designed, fabricated for HMIC, and characterized for microwave and millimeter-wave device applications. The proposed package is fabricated by using two high resistivity silicon substrates and surface/bulk micromachining technology. It has a good performance characteristic such as -20㏈ of $S_11$/ and -0.3㏈ of $S_21$ up to 20㎓, which is useful in microwave region. It has also better heat transfer characteristics than the commonly used ceramic package. Since the proposed silicon MEMS package is easy to fabricate and wafer level chip scale packaging is also possible, the production cost can be much lower than the ceramic package. Since it will be a promising low-cost package for mobile/wireless applications.

혼합물실험계획법과 가진을 이용한 알루미나 파우더의 충진율 분석 (Analysis of Powder Packing for Alumina Using Design of Experiment with Mixture and Vibration)

  • 전상준;김영신;양대종
    • Composites Research
    • /
    • 제34권5호
    • /
    • pp.330-336
    • /
    • 2021
  • 알루미나 파우더는 산업용으로 널리 사용되는 소재 중 하나이지만 파우더 패킹 상태에 따라 제품의 강도가 변하는 문제점이 있다. 위 문제해결을 위하여 입자 패킹효율을 높이려는 많은 선행연구들이 수행되었지만, 기존 연구는 밀리미터 스케일의 입자의 충진 특성을 분석한 것이 대부분이므로 마이크로미터 스케일과 물리적 특성이 달라, 그 선행연구 결과를 토대로 마이크로미터 스케일에 적용하기 어렵다. 따라서 본 논문에서는 마이크로미터 스케일의 알루미나 파우더를 이용하여 충진률을 높이기 위하여 통계적방법을 이용하여 3단계 실험을 수행하였다. 먼저, 혼합물시험계획법을 이용하여 충진율이 높은 크기 조합 및 혼합 비율을 선정하였으며, 진동 실험장치에서 가진 주파수 변경에 따른 충진 높이 변화를 분석하여 적정 가진 주파수를 선정하였다. 마지막으로 앞서 언급한 실험 결과값을 토대로 알루미나 파우더 충진율 시험을 수행하였다. 그 결과, 최대 높이 변화량은 충진 크기조합 선정을 위해 수행한 최초의 실험 결과 최댓값보다 42% 향상된 것을 확인하였다.