• Title/Summary/Keyword: Middle ear

Search Result 190, Processing Time 0.025 seconds

A Study on Frequency Characteristics According to the Output Transmission Method of Round Window Driving Middle Ear Implants (정원창 구동형 인공중이의 출력 전달 방식에 따른 주파수 특성 연구)

  • Seong, KiWoong;Shin, DongHo;Na, SungDae;Lee, JyungHyun;Kim, MyoungNam;Cho, Jin-Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.39 no.5
    • /
    • pp.183-187
    • /
    • 2018
  • In this paper, we investigated the efficiency according to the output transmission method of the round window driving type AMEIs (active middle ear implants) through the cadaveric experiment. For the experiment, we fabricated DRT (direct rod transducer) and FMT (floating mass transducer) type vibrational transducers based on our previous studies and conducted their output characteristics were measured. TCBT (tri-coil bellows transducer) and DFMT (differential floating mass transducer) were implemented with the same driving force and electrical characteristics as one of DRT and FMT, respectively. In the experiment using three human temporal bone, normal stapes vibration was measured with 1 Pa in front of tympanic membrane, and then was compared with each output of transducers. From the comparison, the DRT type vibration transducer was superior in overall energy transfer efficiency, especially in the low frequency range. There was no difference in implantation difficulty between the two transducers. The results of this study suggest that the DRT type vibrational transducer is more efficient and needs further study to overcome the low frequency degradation in round window approaching with FMT.

Relationship between Increased Intracranial Pressure and Mastoid Effusion

  • Jung, Hoonkyo;Jang, Kyoung Min;Ko, Myeong Jin;Choi, Hyun Ho;Nam, Taek Kyun;Kwon, Jeong-Taik;Park, Yong-sook
    • Journal of Korean Neurosurgical Society
    • /
    • v.63 no.5
    • /
    • pp.640-648
    • /
    • 2020
  • Objective : This study aimed to assess the relationship between increased intracranial pressure (ICP) and mastoid effusions (ME). Methods : Between January 2015 and October 2018, patients who underwent intracranial surgery and had ICP monitoring catheters placed were enrolled. ICP was recorded hourly for at least 3 days. ME was determined by the emergence of opacification in mastoid air cells on follow-up brain imaging. C-reactive protein (CRP) levels, presence of endotracheal tube (ETT) and nasogastric tube (NGT), duration of intensive care unit (ICU) stay, duration of mechanical ventilator application, diagnosis, surgical modalities, and presence of sinusitis were recorded. Each factor's effect on the occurrence of ME was analyzed by binary logistic regression analyses. To analyze the independent effects of ICP as a predictor of ME a multivariable logistic regression analysis was performed. Results : Total of 61 (53%) out of 115 patients had ME. Among the patients who had unilateral brain lesions, 94% of subject (43/50) revealed the ipsilateral development of ME. ME developed at a mean of 11.1±6.2 days. The variables including mean ICP, peak ICP, age, trauma, CRP, ICU stays, application of mechanical ventilators and presence of ETT and NGT showed statistically significant difference between ME groups and non-ME groups in univariate analysis. Sex and the occurrence of sinusitis did not differ between two groups. Adding the ICP variables significantly improved the prediction of ME in multivariable logistic regression analysis. Conclusion : While multiple factors affect ME, this study demonstrates that ICP and ME are probably related. Further studies are needed to determine the mechanistic relationship between ICP and middle ear pressure.

Lumped Model Parameter Estimation of Floating Mass Transducers based on Sequential Quadratic Programming Method for IMEHDs (Sequential Quadratic Programming 방법을 이용한 인공중이용 플로팅 매스 트랜스듀서의 집중 모델 파라미터 추정)

  • Park, I.Y.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.5 no.1
    • /
    • pp.59-64
    • /
    • 2011
  • In this paper, the lumped element model parameter estimation method and its implemented estimation software for fabricated floating mass transducers of IMEHDs have been presented so that the estimated parameter values could be compared with the designed ones and applied to predict the output performance when the transducers were implanted into human ears. The presented method is based on the sequential quadratic programming (SQP) for estimating parameters in the transducer's lumped model and has been implemented by the use of LabVIEW graphical language. Using the implemented estimation software, the accuracy of parameter estimation has been verified and our implemented estimation method has been evaluated by the comparison of the estimated transducer parameter values with the designed ones for a practically fabricated floating mass transducer for IMEHDs.

Design of Implantable Microphone for Artificial Middle Ear System

  • Kim Min-Kyu;Lim Hyung-Gyu;Yoon Young-Ho;Lee Jyung-Hyun;Park Il-Yong;Song Byung-Seop;Kim Myoung-Nam;Cho Jin-Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.26 no.3
    • /
    • pp.139-144
    • /
    • 2005
  • An implantable microphone that can be utilized as part of a totally implantable hearing aid is designed and implemented. The proposed microphone is implanted in the center of the pinna, and designed to ensure the speech frequency range and the appropriate sensitivity. The characteristics of the proposed microphone are evaluated using a finite element analysis (FEA). The microphone is composed of a small electric condenser microphone, titanium case 6.2mm in diameter and 3mm high, and $10{\mu}m$ SUS316L vibrating membrane in contact with hypodermic tissue to maintain the sensitivity of the microphone. The microphone components are all made of biocompatible materials, then the assembled microphone is hermetically sealed using a polymer and ceramic. Experiments with the fabricated microphone confirm an operational bandwidth of up to 5kHz without any decline of sensitivity in 6mm of hypodermic tissue.

A Physical Cochlear Model for Transducer Performance Evaluation of Implantable Hearing Aid with Round Window Driver (정원창 구동기의 진동체 성능 평가를 위한 내이 물리모델)

  • Shin, Dong Ho;Lim, Hyung Gyu;Jung, Eui Sung;Seong, Ki Woong;Lee, Jyung Hyun;Cho, Jin Ho
    • Journal of Sensor Science and Technology
    • /
    • v.22 no.2
    • /
    • pp.150-155
    • /
    • 2013
  • Recently, various hearing aids are developed to overcome hearing loss. There are available hearing aids, such as air conduction hearing aid, implantable middle ear hearing aid and so on. But air conduction hearing aid is inconvenience caused by howling, and ossicle chain driving type implantable middle ear hearing aid has some week point due to problem of possible nercobiosis of coupling spot along incus long process. In recent years, in order to improve these shortcomings round window (RW) driving hearing aid has been paying attention. In this paper, the physical cochlear model is proposed for a performance evaluation of the RW driving hearing aids of a transducer. In order to verify an experiment proposed on a performance of physical cochlear model, the transducer which has ossicles characteristics is used. By measuring and comparing the frequency characteristics of transducer with ossicles and human temporal bone, performance of physical cochlear model was verified. As from the result of experiment, it is expected that an implemented cochlear model is useful for evaluating characteristics of RW transducer.

Bacteriological Studies of Chronic Purulent Ototis Media (만성중이염에 있어서의 세균학적 고찰)

  • Im, Kwan;Kim, Ki-Heon;Kang, Ju-Won;Kim, Byung-Woo
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1972.03a
    • /
    • pp.1.2-1
    • /
    • 1972
  • It is the most important to know the causative organisms and the most effective antibiotics in the cases of chronic suppurative otitis media not only for the treatment of the cases of O.M.P.C. but also for postoperative control of middle ear surgery. In the authors' opinion, there are various organisms in the middle ear depending on the country, hygine, and area, etc., and many new antibiotics have recently been developed. To the otologists, it is helpful to know the causative organisms of O.M.P.C. and to compare with other authors' results about the sensitivity of antibiotics to the organisms. Thus the authors have performed bacteriological studies and its sensitivity test to the causative organisms in the cases of O.M.P.C. and obtained the following results. According to the our studies, in the gram-negative species, Proteus species (16.9%) was the most sensitive to Ampicillin 81.8% and Pseudomonas(18.5%) was the most sensitive to Colimycin 91.7%, and in the gram positive group, Staphylococcus Aureus (29.2%) was sensitive to Erythromycin 100% and Orbenin 94.7%.

  • PDF

Design of electromagnetic type transducer to drive round window with high efficiency (고효율 전자기형 정원창 구동 트랜스듀서의 설계)

  • Lee, Jang-Woo;Kim, Dong-Wook;Kim, Myoung-Nam;Cho, Jin-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.449-455
    • /
    • 2010
  • Implantable middle ear hearing devices(IMEHDs) have being actively studied to overcome the problems of conventional hearing aids. Vibration transducer, an output devices of IMEHDs, is attached on the ossicular chain and transmits mechanical vibration to cochlea. This approach allows us to hear more clear sound because mechanical vibration is effective to transfer high frequency acoustics, but occurs some problems such as fatigue accumulation to ossicular chian and reduction of vibration displacement caused by mass loading effect. Recently, many studies for the round window stimulation are announced, because it does not cause such problems. It have been studied by older transducers designed for attaching on ossicular chain. In this paper, we proposed a new electromagnetic transducer which consists of two magnets, three coils and a vibration membrane. The magnet assembly, magnet coupled in opposite direction, were placed in the center of three coils, and the optimum length of each coil generating maximum vibrational force was calculated by finite element analysis(FEA). The transducer was implemented as the calculated length of each coil, and measured vibration displacement. From the results, it is verified the vibration displacement can be improved by optimizing the length of coils.

Clinical Study with Impedance Audiometry -Euatachian tube function and impedance audiometry- (Impedance audiometry의 임상적 연구 - III. impedance audiometry에 의한 구씨관 기능검사 -)

  • 민양기;노관택
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1976.06a
    • /
    • pp.85.2-85
    • /
    • 1976
  • Harford has pointed out that the application of impedance audiometry in the Eustachian tube function is of special value. As you know, with excessive negative pressure in the middle ear cavity with intact eardrum tympanograms reveal indirect evidence of Eustachian tube insufficiency. With normal Eustachian tube function eardrum should be pushed laterally by Valsalva maneuver, resulting in a temporary decrease in the compliance of the system, indicated by a swing of the balance meter needle. Therefore the authors measured the swing of the balance meter needle by the Valsalva maneuver in persons with intact eardrums, intact middle ear cavities, and intact Eustachian tube function. The results are as follows; The swing of the eardrum by Valsalva maneuver is 1.0 to 4.0 (mean $1.6{\pm}0.06$) and we conclude that the persons under 1.0 of the swing is suggestive of some disfunctions of the Eustachian tube.

  • PDF

Ultrastructure of the tympanic mucosa in experimentally produced serous otitis media (고양이에서 유발된 장액성중이염시 중이점막의 미세구조에 관한 연구)

  • Park, Soon-Il;Yoon, Kang-Mook;Shim, Sang-Yul
    • Applied Microscopy
    • /
    • v.12 no.1
    • /
    • pp.1-10
    • /
    • 1982
  • Serous otitis media is closely related with auditory tube function, but its etiology and pathogenesis are not clearly defined yet. So we tried to prove the theory of hydrops ex vacuo via the experimental study with cats by means of obstructing the pharyngeal orfice of the auditory tube and observe the serial changes in tympanic mucosa through light and electron microscopy. The results are as follows; 1. We confirmed the production of serous otitis media with auditory tube obstruction and have a new understanding of auditory tube function in middle ear aeration. 2. The effusion in serous otitis media was produced from the next day of experiment and increased till the fourteenth day, but decreased after the spontaneous perforation of ear drum. 3. Through the light microscopy, we observed the increasement of the sercretory cells including goblet cells, epithelial hyperplasia, capillary proliferation and invasion of inflammatory cells. 4. Through the elctron microscopy, we observed the protrusion of secretory cells, blobs in cilia, loss of cilia, increasement of vesicles, vacuoles and dense bodies in ciliated cells and Invasion of inflammatory cells. With above results, we concluded that aeration through auditory tube is the most important factor in serous otitis media and presumed the effusion was secreted by secretory cells.

  • PDF

The Effects of Auricular Acupressure Therapy on Middle-aged and Old Adults' Dry Eye Syndrome (이압요법이 중·노년의 안구건조증에 미치는 효과)

  • Choi, Yun-Joo;Hwang, Sun-Kyung;Kim, Sang-Sik
    • Journal of East-West Nursing Research
    • /
    • v.26 no.1
    • /
    • pp.17-27
    • /
    • 2020
  • Purpose: This study aimed to examine the effect of auricular acupressure therapy on reducing the ocular symptoms and signs for dry eye syndrome. Methods: The participants who were aged ≥ 40 years old and met the inclusion criteria of the ocular surface disease index score ≥ 13 and a tear film break-up time ≤ 10 seconds were enrolled into the two groups: experimental group (n=29) and control group (n=27). Experimental group received auricular acupressure therapy for 8 weeks. Seed stickers were applied to the eye, liver and tubercle point of each ear once a week. Data were collected at pre and 4 and 8 weeks after the treatment and analysed the efficacy of intervention by repeated measures ANOVA. Results: There were significant differences in the ocular surface disease index, standard patient evaluation of eye dryness and a tear film break-up time in both eyes at 8 weeks after the treatment between the two groups. Conclusion: The findings indicate that the auricular acupressure therapy may be helpful for relieving symptoms of dry eye as a nursing intervention. In addition, it could also be utilized as a self-care practice using proper education and training.