• Title/Summary/Keyword: Middle Power

Search Result 804, Processing Time 0.032 seconds

Drying Characteristics of Large Western Redcedar Timber During Radio Frequency/Vacuum Drying (웨스턴 레드시더 큰 정각재(正角材)의 고주파 진공 건조 특성)

  • Jung, Hee-Suk;Avramidis, Stavros;Cai, Liping
    • Journal of the Korean Wood Science and Technology
    • /
    • v.26 no.3
    • /
    • pp.1-8
    • /
    • 1998
  • Western redcedar timber, 26 by 26cm in cross section and by 200cm long, was dried in a laboratory radio-frequency/vacuum kiln under 65torr of ambient pressure and a fixed frequency of 6.78MHz for the potential rapidly dry large timber. All process data were collected and saved in a computer through a data acquisition system. The temperature in the middle of timber was higher than temperature at the quarter point of timber length and thickness. Temperature gradients developed in the longitudinal and transverse direction of timber. The pressure in the middle of timber was higher than pressure at the quarter point of timber length. The pressure in the middle of timber was lower in the early stage of drying, and higher in the latter stage of drying than pressure at the quarter point of timber thickness. Power density was very highest during heating period and then gradually decreased. The drying curve was approximately linear and the total drying time was 27 hours from an initial moisture content(MC) of 48.6 percent to a final Me of 19.2 percent with only a few mild internal checks in the middle location of timber.

  • PDF

Al-foil Electrode for Detecting Partial Discharge in Middle Joint Box (초고압 전력케이블용 중간접속부내 부분방전 검출을 위한 박전극)

  • Shin, Hyun-Mahn;Kim, Hyang-Kon
    • Proceedings of the KIEE Conference
    • /
    • 2008.09a
    • /
    • pp.211-213
    • /
    • 2008
  • To detect partial discharge of 154kV joint box, we have made experiment by using the Al-foil electrode sensor. Generally the signals which are detected in partial discharge test of underground power transmission cable are accompanied with both noises of high voltage and noises of surrounding power cable. The most noise in near to end part of joint box is corona, beside other noises flowed from surrounding area. Partial discharge test is difficulty due to these noises. First, we had used Al-Foil sensor on middle joint box of 154[kV] underground transmission power cable, and then analysed reliability of calibration signal by using the Al-Foil electrode sensor of NJB. From above results, decrement properties measured highly. But incase of injecting calibration signal of 500[pC] after measuring signals in IJB, the S/N ratio had about 25[dB] acquisition.

  • PDF

Effects of Education Concerning Radiation and Nuclear Safety and Regulation on Elementary, Middle, and High School Students in Korea

  • Choi, Yoon-Seok;Kim, Jung-Min;Han, Eun-Ok
    • Journal of Radiation Protection and Research
    • /
    • v.45 no.3
    • /
    • pp.108-116
    • /
    • 2020
  • Background: This foundational study on educational interventions aimed to analyze the changes in awareness, knowledge, and attitudes of young learners after they received objective information on safety management. Materials and Methods: Educational sessions on nuclear power and radiation safety were delivered to 4,934 Korean elementary, middle, and high school students in two separate sessions conducted in 2016 and 2017. The effects of these interventions were subsequently analyzed. Results and Discussion: Learner attitudes toward safety were found to be the predominant variables affecting the post-intervention risk (safety) awareness of nuclear power generation. Conclusion: The safety awareness of future generations will significantly influence policy decisions on nuclear power generation. Hence, the design of educational interventions on this subject must match variables suited to learner levels.

Fresnel lens optics simulation with middle sized linear concentration without secondary optics (2차 광학계가 필요없는 프레넬 렌즈를 이용한 중집광 광학계 시뮬레이션)

  • Kang, Sung-Won;Kim, Yong-Sik;Sim, Chang-Ho
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.27-33
    • /
    • 2011
  • HCPV(High Concentrated PV) systems have well known for CPV market all over the world. Low concentration type silicon based modules have been introduced in the market. But low cost of standard flat silicon modules made them useless nowadays. High cost of compound semiconductor solar cell reduced cost effective cpv module production than that of recently silicon solar cell. In order to overcome increasing cost of CPV module, we study middle concentration type fresnel lens simulation using concentrated type silicon based solar cell. Linear type fresnel lens made production of CPV module without secondary optics such as light pipe or light tunnel. This type of fresnel lens design makes more cost effective solution for cpv niche market.

  • PDF

Ecological Study of the Marine Algal Community at the Coast of Taean Thermal Power Plant, Korea (태안화력발전소 주변 해조군집의 생태 연구)

  • Yu, Jong-Su;Kim, Yeong-Hwan
    • ALGAE
    • /
    • v.18 no.4
    • /
    • pp.311-320
    • /
    • 2003
  • The community structure of benthic marine algae was investigated at Taean Thermal Power Plant and other places around Taean Peninsula, the west coast of Korea. Total of 100 species including 3 Cyanophyta, 14 Chlorophyta, 18 Phaeophyta, and 65 Rhodophyta were identified. The number of species was highest with 78 species at the Power Plant intake, followed by 61 at the discharge, 56 at Bunjeondo, and 50 at Maoe. It was noteworthy that a subtropical species Caulerpa okamurae was collected at the intake in autumn and it was the first observation in the west coast of Korea. The pattern of vertical algal distribution showed Gloiopeltis furcata occurred in the upper intertidal zone, Sargassum thunbergii and Corallina spp. in the middle and lower zone and Enteromorpha spp. in the lower middle zone. These were all dominant species except for Enteromopha spp., which was subdominant species. Other subdominant species were Chondrus ocellatus and Neorhodomela aculeata. The average diversity indices were between 0.70 and 1.20 at each area based on their dry weight. The similarity index was 0.79 between the algal flora of this study and that of 1987, indicating that the condition of the benthic environment remained unchanged since then. This area maintained its environmental quality, so the algal community remained same with similar structure. This study area seemed a suitable place for long term monitoring of the benthic environment where industrial facilities such as a power plant might affect the benthic algal community.

The Application of Al-foil Electrode for Detecting Partial Discharge Signal in Middle Joint Box of EHV Power Cable (초고압 전력케이블용 중간 접속부 내의 부분방전신호 검출을 위한 박전극 응용)

  • Lee, Yong-Sung;Yang, Jong-Kyung;Yang, Jong-Keok;Choi, Yong-Sung;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.142-144
    • /
    • 2005
  • To detect partial discharge of 154kV joint box, we have made experiment by using the Al-foil electrode sensor. Generally the signals which are detected in partial discharge test of underground power transmission cable are accompanied wi th both noises of high voltage and noises of surrounding power cable. The most noise in near to end part of joint box is corona, beside other noises flowed from surrounding area. Partial discharge test is difficulty due to these noises. First, we had used Al-Foi1 sensor on middle joint box of 154[kV] underground transmission power cable, and then analyzed reliability of calibration signal by using the Al-Foi1 electrode sensor of NJB. From above results, decrement properties measured highly. But incase of injecting calibration signal of 500[pC] after measuring signals in IJB, the S/N ratio had about 25[dB] acquisition.

  • PDF

The Vibration Suppression using Reactive Power Compensator for Speed Control of Parallel Connected Dual Fan Motors fed by a Single Inverter (단일 인버터 기반 에어컨용 실외기 팬 모터 병렬운전에서의 무효전력보상기를 이용한 맥동저감 기법)

  • Yun, Chul;Kwon, Woo-Hyen;Cho, Nae-Soo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.12
    • /
    • pp.2008-2013
    • /
    • 2016
  • This paper proposes analysis and suppression method for reactive power vibration of the slave motor caused by back-EMF mismatch between the master and the slave motor and stator resistance during middle-low speed operation. The master and slave motors are parallel connected dual SPMSMs(Surface mounted Permanent Magnet Synchronous Motors) fed by a single inverter. To suppress vibration of reactive power, RPC(Reactive Power Compensator) proposed in this paper analyzes flux-axis current vibration of the slave motor that occurs in middle-low speed operation using a mathematical model of the fan motor. And RPC adds vibration components detected from flux-axis current of the slave motor to flux-axis current of the master motor. The results of experiment conducted verify the efficacy of the proposed method.

The Numerical Simulation of Unsteady Flow in a Mixed flow Pump Guide Vane

  • Li, Yi-Bin;Li, Ren-Nian;Wang, Xiu-Yong
    • International Journal of Fluid Machinery and Systems
    • /
    • v.6 no.4
    • /
    • pp.200-205
    • /
    • 2013
  • In order to investigate the characteristics of unsteady flow in a mixed flow pump guide vane under the small flow conditions, several indicator points in a mixed flow pump guide vane was set, the three-dimensional unsteady turbulence numerical value of the mixed flow pump which is in the whole flow field will be calculated by means of the large eddy simulation (LES), sub-grid scale model and sliding mesh technology. The experimental results suggest that the large eddy simulation can estimate the positive slope characteristic of head & capacity curve. And the calculation results show that the pressure fluctuation coefficients of the middle section in guide vane inlet will decrease firstly and then increase. In guide vane outlet, the pressure fluctuation coefficients of section will be approximately axially symmetrical distribution. The pressure fluctuation minimum of section in guide vane inlet is above the middle location of the guide vane suction surface, and the pressure fluctuation minimum of section in which located the middle and outlet of guide vane. When it is under the small flow operating condition, the eddy scale of guide vane is larger, and the pressure fluctuation of the channel in guide vane being cyclical fluctuations obviously which leads to the area of eddy expanding to the whole channel from the suction side. The middle of the guide vane suction surface of the minimum amplitude pressure fluctuation to which the vortex core of eddy scale whose direction of fluid's rotation is the same to impeller in the guide vane adhere.

The Effects of Family Functionality and Self-efficacy on Retirement Anxiety Among Middle-aged Men (중년남성의 가족기능성, 자기효능감이 은퇴불안에 미치는 영향)

  • Lim, Kyoung-Min;Park, Jung-Hoon;Oh, Chang-Seok
    • The Korean Journal of Health Service Management
    • /
    • v.12 no.3
    • /
    • pp.131-141
    • /
    • 2018
  • Objectives: This study was designed to determine the effects of middle-aged men's family functionality and self-efficacy on their retirement anxiety, in order to produce methods to alleviate this anxiety, including providing basic information for devising programs that help middle-aged men get better adjusted to and increase their awareness about retirement. Methods: For data collection, the study surveyed 364 middle-aged men who were residing in B Metropolitan City from February. 10 to 25, 2017. Results: This study found that the primary factor influencing middle-aged men's retirement anxiety is self-efficacy, for which the explanatory power for the surveyed men's retirement anxiety was 52.0%. In contrast, family functionality had no effect on retirement anxiety. Conclusions: To make middle-aged men less anxious about retirement, a variety of programs must be created and implemented that help them improve their self-efficacy prior to retirement. Furthermore, these men should be provided with educational and intervention programs that facilitate their adjustment to retirement and increase their awareness about retirement.