• Title/Summary/Keyword: Microwave Radiation

Search Result 233, Processing Time 0.021 seconds

POLARIZATION AND POLARIMETRY: A REVIEW

  • Trippe, Sascha
    • Journal of The Korean Astronomical Society
    • /
    • v.47 no.1
    • /
    • pp.15-39
    • /
    • 2014
  • Polarization is a basic property of light and is fundamentally linked to the internal geometry of a source of radiation. Polarimetry complements photometric, spectroscopic, and imaging analyses of sources of radiation and has made possible multiple astrophysical discoveries. In this article I review (i) the physical basics of polarization: electromagnetic waves, photons, and parameterizations; (ii) astrophysical sources of polarization: scattering, synchrotron radiation, active media, and the Zeeman, Goldreich-Kylafis, and Hanle effects, as well as interactions between polarization and matter (like birefringence, Faraday rotation, or the Chandrasekhar-Fermi effect); (iii) observational methodology: on-sky geometry, influence of atmosphere and instrumental polarization, polarization statistics, and observational techniques for radio, optical, and $X/{\gamma}$ wavelengths; and (iv) science cases for astronomical polarimetry: solar and stellar physics, planetary system bodies, interstellar matter, astrobiology, astronomical masers, pulsars, galactic magnetic fields, gamma-ray bursts, active galactic nuclei, and cosmic microwave background radiation.

Retrospective dosimetry using fingernail electron paramagnetic resonance response

  • Noori, Abbas;Mostajaboddavati, Mojtaba;Ziaie, Farhood
    • Nuclear Engineering and Technology
    • /
    • v.50 no.3
    • /
    • pp.526-530
    • /
    • 2018
  • Human fingernails were used to estimate the radiation dose via electron paramagnetic resonance measurements of radiation-induced radicals. The limiting factors in this research were mechanically induced electron paramagnetic resonance signals due to the mechanical stress during the preparation of the samples. Therefore, different treatment methods of fingernails were used to reduce the mechanically induced signals. The results demonstrate that the mechanically induced and radiation-induced signals have apparently different microwave power saturation behaviors. In addition, the mechanically induced signal shows a fading evolution over time and reaches a constant value. Chemical treatment using the different reagents showed that the minimum mechanically induced signal was obtained using the dithiothreitol reagent. The dose-response curves of the samples treated with dithiothreitol for 30 minutes demonstrated a greater linearity than those of samples treated for 5 minutes. Therefore, to find an unknown absorbed dose in a fingernail sample using a calibration curve, we recommend adopting the mentioned chemical treatment procedure to reduce the uncertainty.

A Facile Solvent and Catalyst Free Synthesis of New Dihydro Pyrimidinones as Antimicrobial Agents

  • Hegde, Hemant;Ahn, Chuljin;Gaonkar, Santosh L.;Shetty, Nitinkumar S.
    • Journal of the Korean Chemical Society
    • /
    • v.63 no.6
    • /
    • pp.435-439
    • /
    • 2019
  • An efficient one pot multicomponent synthesis of pyrimidinone derivatives of Biginelli type is described. 4-amino-6-aryl-pyrimidine-5-carbonitrile molecules were synthesized efficiently via three-component Biginelli-type condensation of aldehyde, malononitrile, and semicarbazone as urea substituent in the presence of a catalytic amount of PEG-400 as green medium under microwave irradiation. The reactions proceeded efficiently in the presence of microwave radiation to afford the desired products in good to excellent yields. Products have been confirmed by IR, and NMR spectral analysis. All the molecules were tested for their antimicrobial activity against E. coli, S. aureus, P. aeruginosa and C. tropicalis. Some of the compounds have shown moderate to good inhibition efficiency against both gram-positive and gram-negative bacteria. The potent activity was observed against the fungal species with minimum inhibition concentration 12.5 ㎍/mL.

Development of Helical Antenna using Microwave ZST Ceramics (마이크로파 ZST 세라믹을 이용한 Helical Antenna 개발)

  • Lee, Jong-Bae;Yook, Young-Jin;Sin, Ho-Yong;Kim, Hyung-Sun;Im, Jong-In
    • Journal of the Korean Ceramic Society
    • /
    • v.45 no.4
    • /
    • pp.208-213
    • /
    • 2008
  • In this study, helical antenna with microwave ZST ceramics was designed using finite element method and developed. Studied parameters are relative dielectric constant of the dielectric core and the width of the conduction metal band of the antenna. As shown in the results, the center frequency of the antenna was decreased as the dielectric constant increased. Also beam width of the antenna increased as both the dielectric constant and the conduction band width increased. Based on the designed optimal shape, the manufactured antenna has the good beam width at center frequency 1.58 GHz.

Symmetric Microwave Lens with Uniform Insertion Loss for Broad-band and Wide Beam Steering Coverage (균일한 삽입손실을 갖는 광대역 빔 조향용 대칭형 초고주파 렌즈)

  • 김인선;이광일;오승엽
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.3
    • /
    • pp.279-287
    • /
    • 2002
  • In this paper, a symmetric microwave lens to steer wide angle and to operate at broad band frequency range for a linear phased array transmitter was designed. To get accurate beam steering performance far a linear phased array transmitter, uniform amplitude transmission characteristics of microwave lens was focused. The measured result for the insertion loss deviation between Input and output ports of microstrip lens with 8 beam ports and 8 array ports was $\pm$3.1 ㏈ over 6~18 ㎓ band, which was very uniform characteristics. Using 8 elements linear array antenna, it was confirmed the radiation beam could be steered over $\pm$60$^{\circ}$ in azimuth. And the measured lens performance data and multi-beam steering pattern were presented.

Application on Microwave Energy in the Preparation of Fish Samples for Electron Microscopic Observation

  • Kim Soo Jin;Oh Hae Keun;Song Young-Hwan;Chung Hyun-Do;Kim Young-Tae;Park Nam-Kyu;Choi Tae-Jin
    • Fisheries and Aquatic Sciences
    • /
    • v.1 no.2
    • /
    • pp.187-191
    • /
    • 1998
  • Chemotherapy can not be applied for the control of fish viral diseases because viruses depend on host machinery for their replication. Although new control strategies including vaccination are under development, avoidance of virus introduction by rapid and correct diagnosis is the best way of fish viral disease control. Although observation of virus particles with an electron microscope is an easy method for virus detection, it take a few days for the sample preparation. In order to shorten the sample preparation time, microwave radiation was applied in the procedure. With this method, 15 seconds was enough for fixation of virus infected fish samples or cultured cells inoculated with infectious hematopoietic necrosis virus, which takes 2-4 hours with routine methods. Also four minutes was enough for polymerization of embedding resin which takes 24-48 hours with routine methods. Samples prepared with microwave were good enough for direct electron microscopic observation and immunogold labeling assay.

  • PDF

Design and Implementation of the Small Size Microwave Sensor Receiver for Human Body Detection (인체 감지용 소형 마이크로파 센서 수신기의 설계 및 제작)

  • Son, Hong-Min;Choi, Hyun-Ho
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.4
    • /
    • pp.403-406
    • /
    • 2016
  • This paper presents the design and implementation of the small size receiver to put a passive microwave sensor for human body detection to practical use. The requirements and specifications of the sensor receiver are drawn using the experimental data of human body detection by the existing sensor operated at 5.1 GHz. The small size sensor receiver to satisfy the drawn specifications is designed and implemented. The effectiveness of the fabricated sensor with small size receiver on human body detection is demonstrated experimentally in laboratory. The results show the sensor can detect human body to within 4 m distance from the antenna. The size and power consumption of the small size receiver are decreased to 60 % and 40 % compared to those of the existing receiver, respectively.

Microfabrication of Microwave Transceivers for On-Chip Near-Field Electromagnetic Shielding Characterization of Electroplated Copper Layers (극소형 전자기파 송수신기의 제작 및 전기도금된 구리박막의 칩단위 근접 전자기장 차폐효과 분석)

  • Gang, Tae-Gu;Jo, Yeong-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.6
    • /
    • pp.959-964
    • /
    • 2001
  • An experimental investigation on the near-field electromagnetic loss of thin copper layers has been presented using microfabricated microwave transceivers for applications to multi-chip microsystems. Copper layers in the thickness range of 0.2$\mu$m∼200$\mu$m have been electroplated on the Pyrex glass substrates. Microwave transceivers have been fabricated using the 3.5mm$\times$3.5mm nickel microloop antennas, electroformed on the silicon substrates. Electromagnetic radiation loss of the copper layers placed between the microloop transceivers has been measured as 10dB∼40dB for the wave frequency range of 100MHz∼1GHz. The 0.2$\mu$m-thick copper layer provides a shield loss of 20dB at the frequencies higher than 300MHz, whereas showing a predominant decreases of shield loss to 10dB at lower frequencies. No substantial increase of the shield effectiveness has been found for the copper shield layers thicker that 2 $\mu$m.