• 제목/요약/키워드: Microwave Effective Index

검색결과 16건 처리시간 0.024초

급격히 꺾인 Taper를 갖는 Traveling-wave Coplanar Waveguide형 $LiNbO_34$전기광학변조기 전송선로의 전기적 특성 (Electrical Properties of Traveling-wave Coplanar Waveguide Transmission Line with a Abruptly broken Input-Output-taper for $LiNbO_3$Optical Modulator Electrode)

  • 정운조;김성구
    • 한국전기전자재료학회논문지
    • /
    • 제13권12호
    • /
    • pp.1051-1057
    • /
    • 2000
  • A traveling-wave CPW(coplanar waveguide) electrode with abruptly broken input/output-taper for LiNbO$_3$optical modulator was designed and fabricated. The electrical characteristics of traveling-wave electrode on z-cut LiNbO$_3$crystal with SiO$_2$buffer layers were measured by network analyzer. To confirm the possibility of the electro-optic modulator electrode, detailed calculations of the impedance, microwave effective index and attenuation constants are presented as a function of the microwave electrode thickness, but the buffer layer thickness is fixed as 1${\mu}{\textrm}{m}$. These characteristics are discussed from the viewpoint of the device optimization and are expected to be design guides for the LiNbO$_3$modulator’s electrodes.

  • PDF

Characterization of Heterogeneous Interaction Behaviour in Ternary Mixtures by Dielectric Analysis: The H-Bonded Binary Polar Mixture in Non-Polar Solvent

  • Sengwa, R.J.;Madhvi;Sankhla, Sonu;Sharma, Shobha
    • Bulletin of the Korean Chemical Society
    • /
    • 제27권5호
    • /
    • pp.718-724
    • /
    • 2006
  • The heterogeneous association behaviour of various concentration binary mixtures of mono alkyl ethers of ethylene glycol with ethyl alcohol were investigated by dielectric measurement in benzene solutions over the entire concentration range at 25 ${^{\circ}C}$. The values of static dielectric constant $\epsilon_0$ of the mixtures were measured at 1 MHz using a four terminal dielectric liquid test fixture and precision LCR meter. The high frequency limiting dielectric constant $\epsilon_\infty$ values were determined by measurement of refractive index $n_D$ ($\epsilon_\infty\;=\;n_D\;^2$). The measured values of $\epsilon_0$ and $\epsilon_\infty$ were used to evaluate the values of excess dielectric constant $\epsilon^E$, effective Kirkwood correlation factor $g^{eff}$ and corrective correlation factor $g_f$ of the binary polar mixtures to obtain qualitative and quantitative information about the H-bond complex formation. The non-linear behaviour of the observed $\epsilon_0$ values of the polar molecules and their mixtures in benzene solvent confirms the variation in the associated structures with change in polar mixture constituents concentration and also by dilution in non-polar solvents. Appearance of the maximum in $\epsilon^E$ values at different concentration of the polar mixtures suggest the formation of stable adduct complex, which depends on the molecular size of the mono alkyl ethers of ethylene glycol. Further, the observed $\epsilon^E$ < 0 also confirms the heterogeneous H-bond complex formation reduces the effective number of dipoles in these polar binary mixtures. In benzene solutions these polar molecules shows the maximum reduce in effective number of dipoles at 50 percent dilutions. But ethyl alcohol rich binary polar mixtures in benzene solvent show the maximum reduce in effective number of dipoles in benzene rich solutions.

릿지 형태 CPW 진행파형 구조의 등가회로 분석 (Analysis of Equivalent Circuit Approach for Ridge Type CPW Traveling - Wave Structure)

  • 윤상준;공순철;옥성해;윤영설;구민주;박상현;최영완
    • 대한전자공학회논문지SD
    • /
    • 제41권3호
    • /
    • pp.45-54
    • /
    • 2004
  • 릿지 형태 CPW 진행파형 전계 흡수 광 변조기와 광 검출기의 구조에 있어서 마이크로파의 특성은 도파관을 형성하는 진성 영역의 폭, 두께, 신호전극과 접지 전극사이의 거리의 영향을 받게 된다. 이러한 요소들은 소자에 존재하는 캐패시턴스(C)와 인덕턴스(L)의 크기를 변화시키게 되며 마이크로파의 유효 굴절률과 특성 임피던스를 결정하게 된다. 하지만 기존의 논문들은 전계와 자계의 분포에 따라 마이크로스트립과 CPW로 각각 근사화하여 해석했다. 본 논문에서는 FDTD를 이용해 릿지형태 CPW 진행파형 구조의 마이크로파 특성을 분석하고 C와 L의 정량적인 값을 구했으며 이를 등가회로의 회로 소자로써 적용 시켰다. 등가회로에서 구해진 마이크로파의 특성은 FDTD 결과와 거의 일치함을 보였다.

Clinical Significance of Joint Detection of Serum VEGF, SIL-2R and HGF in Patients with Primary Hepatocellular Carcinoma before and after Percutaneous Microwave Coagulation Therapy

  • Chen, Ji-Dong;Xiong, Yan-Qun;Dong, Ke;Luo, Jun;Yue, Lin-Xian;Chen, Qin
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권11호
    • /
    • pp.4545-4548
    • /
    • 2014
  • Objective: To investigate the changes of serum vascular endothelial growth factor (VEGF), soluble interleukin-2 receptor (SIL-2R) and hepatocyte growth factor (HGF) contents in patients with primary hepatocellular carcinoma (HCC) before and after percutaneous microwave coagulation therapy (PMCT) and determine their clinical significance. Materials and Methods: Fasting venous blood (3 mL) from 81 patients with primary HCC diagnosed by pathology was collected in the mornings 1 day before PMCT, and 1 day, 7 days and 1 month after PMCT, and then the serum was separated and stored in $-70^{\circ}C$. The contents of VEGF, SIL-2R and HGF were detected by enzyme linked immunosorbent assay (ELISA). Results: The serum VEGF, SIL-2R and HGF contents in 81 patients with primary HCC had obviously dynamic changes before and after PMCT. By comparison to 1 day after PMCT with pre-operation, there was no statistical significance regarding VEGF and SIL-2R contents (P>0.05), but HGF content showed significant difference (P<0.01). Compared with pre-operation, VEGF, SIL-2R and HGF contents 7 days and 1 month after PMCT all manifested significant differences (P<0.01). By comparison to 7 days with 1 month after PMCT, there was no statistical significance regarding the VEGF content (P>0.05), whereas SIL-2R and HGF contents showed significant change (P<0.01). Conclusions: The contents of serum VEGF, SIL-2R and HGF have obviously dynamic changes in primary HCC before and after PMCT, and their joint detection is expected to be an effective hematologic evaluation index of PMCT for primary HCC.

진행파형 전기광학 집적소자에 대한 전극의 위상정합에 관한 연구 (A Study on Phase-Matching of Electrodes for Traveling-Wave Electrooptic Integrated Devices)

  • 정홍식;이두복;정영식
    • 전자공학회논문지A
    • /
    • 제29A권8호
    • /
    • pp.41-48
    • /
    • 1992
  • The characteristics of traveling-wave electrodes for high-frequency electroptic integrated devices are described from the view point of improvement of phase-matching based on the conformal mapping method. Specific calculations of the characteristic impedance, effective microwave index, and eletrode loss for asymmetric coplanar strip(ACPS) and coplanar waveguide(CPW) electrode structures are presented as a function of the geometric electrode parameters including the electrode thickness and buffer layer thickness. 5-10(x10S0-6Tm) thick Au-ACPS electrodes were successfully fabricated by electroplating and ECR etcher. The improvement of modulation bandwidth can be theoretically observed from the combination of electrode and buffer layer thickness.

  • PDF

100Gbps Ti:LiNbO$_3$ 광강도 변조기 (100Gbps Ti: LiNbO$_3$ Optical Intensity Modulator)

  • 김성구;이한영;윤형도;임상규;구경환
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.282-285
    • /
    • 1999
  • Fabrication and pakaging method for low delve voltage and 10Gbps Ti diffused waveguide LiNbO$_3$ optical intensity modulator are described. Optical waveguides were prepared by conventionaly electron-beam evaporation and Ti-indiffusion into Z-cut plate LiNbO$_3$. Traveling-wave electrodes were used for obtaining the wideband frequency response and impedance matching. Microwave effective index and characteristic impedance measured by time domain reflectometry and compared with the calculated value by conformal mapping. The characteristics of 10Gbps modulator at the 1550nm wavelength are as follows : perfect modulation voltage Is about 5V, optical insertion loss Is about 5dB, 3-dB bandwidth is 10GHz, and characteristic impedance is about 50$\Omega$.

  • PDF

Ridge형 도파로구조 X-cut $LiNbO_3$ 광변조기의 광대역 설계 (Wide-band design of X-cut $LiNbO_{3}$ optcal modulator employing a ridge waveguide)

  • 허현;김희주;반재경
    • 한국통신학회논문지
    • /
    • 제22권1호
    • /
    • pp.89-95
    • /
    • 1997
  • X-cut y-propagation $LiNbO_{3}$ 광변조기를 해석하고, 광대역 변조특성을 얻기 위한 설계조건을 구한다. 먼저, 구성된 전극에 대하여 최대 변조효율을 얻기 위한 광도파로의 최적위치를 찾고, 다양한 설계조건에 따른 구동전압, 특성 임피던스, M/W 변조파 유효굴절율을 계산하였으며, 이와 같은 수치적 해석을 위해 유한요소법(FEM: Finite Element Method)을 사용하였다. 그리고 사용된 설계 틀의 유용성을 확인하기 위하여 Becker의 결과와 비교평가 하였다. 본 논문에서는 ridge형 도파로구조의 x-cut $LiNbO_{3}$ 광변조기에 대한 다양한 계산을 통하여, 결과적으로 $1.3{\mu}{\textrm{m}}$의 광신호에 대하여 1.8 V.cm의 구동전압과 특성임피던스 $48.13{\Omega}$ M/W(microwave) 변조파 유효굴절율 2.168을 가치는 x-cut $LiNbO_{3}$ 광변조기를 설계하였다.

  • PDF

Analysis of Coplaner $LiNBO_3$ Waveguide Structures Applicable Electrooptic Modulator with FDTD method

  • Lee, Byung-Je;Byun, Joon-Ho;Kim, Nam-Young;Kim, Jong-Heon;Lee, Jong-Chul
    • 한국전자파학회논문지
    • /
    • 제11권7호
    • /
    • pp.1211-1217
    • /
    • 2000
  • The three-dimensional finite-difference time-domain (FDTD) method and the two-dimensional quasi-static formulation have been used to calculate the characteristic impedance and the microwave effective index of coplanar waveguide structures on Lithium Niobate ($LiNBO_3$) single crystal substrates with a yttria-stabilized zirconia (YSZ) or $SiO_2$ buffer layer. The results shown can be a good source to predict the modulator characteristics. The effects of the thin buffer layer and anisotropy of the $LiNBO_3$ crystal (x-cut and z-cut) are discussed. The comparison between the FDTD and quasi-static results shows good agreement. In this paper, the efficient modeling technique of the FDTD method for the coplanar waveguide (CPW) structures based on an anisotropic substrate with a thin buffer layer is developed.

  • PDF

In vivo antioxidant, hypoglycemic, and anti-tumor activities of anthocyanin extracts from purple sweet potato

  • Zhao, Jin-Ge;Yan, Qian-Qian;Lu, Li-Zhen;Zhang, Yu-Qing
    • Nutrition Research and Practice
    • /
    • 제7권5호
    • /
    • pp.359-365
    • /
    • 2013
  • Anthocyanin from purple sweet potato (PSP) extracted by microwave baking (MB) and acidified electrolyzed water (AEW) exhibited antioxidant activity. After further purification by macroporous AB-8 resin, the color value of PSP anthocyanin (PSPA) reached 30.15 with a total flavonoid concentration of 932.5 mg/g. The purified extracts had more potent antioxidant activities than the crude extracts. After continuously administering the PSP extracts to 12-mo-old mice for 1 mo, the anti-aging index of the experimental group was not significantly different from that of 5-mo-old mice. To a certain degree, PSPA was also effective for controlling plasma glucose levels in male Streptozocin (STZ)-treated diabetic mice. In addition, the extracts inhibited Sarcoma S180 cell growth in ICR mice. Mice consuming the PSP extracts formed significantly fewer and smaller sarcomas than mice consuming the control diets. The highest inhibition rate was 69.03%. These results suggest that anthocyanin extracts from PSP not only exert strong antioxidant effects in vitro, but also had anti-aging, anti-hyperglycemic, and anti-tumor activities.

PERFORMANCE OF COMS SNOW AND SEA ICE DETECTION ALGORITHM

  • Lee, Jung-Rim;Chung, Chu-Yong;Ahn, Myoung-Hwan;Ou, Mi-Lim
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2007년도 Proceedings of ISRS 2007
    • /
    • pp.278-281
    • /
    • 2007
  • The purpose of this study is to develop snow and sea ice detection algorithm in Communication, Ocean and Meteorological Satellite (COMS) meteorological data processing system. Since COMS has only five channels, it is not affordable to use microwave or shortwave infrared data which are effective and generally used for snow detection. In order to estimate snow and sea ice coverage, combinations between available channel data(mostly visible and 3.7 ${\mu}m$) are applied to the algorithm based on threshold method. As a result, the COMS snow and sea ice detection algorithm shows reliable performance compared to MODIS products with channel limitation. Specifically, there is partial underestimation over the complicated vegetation area and overestimation over the area of high level clouds such as cirrus. Some corrections are performed by using water vapor and infrared channels to remove cloud contamination and by applying NDVI to detect more snow pixels for the underestimated area.

  • PDF