Inexpensive Materials for Microsurgery in Middle- and Low-Income Countries

  • Pedro Ciudad;Joseph M. Escandon;Edgar Llanos;Juan Ludena;Oscar J. Manrique;Jorge Castro;Rafael Rossi
    • Archives of Plastic Surgery
    • /
    • v.50 no.1
    • /
    • pp.121-124
    • /
    • 2023
  • With the continuous incorporation of new technologies and advancements in surgical technique, microsurgical procedures around the world have generated a higher success rate and innovative procedures are now possible. In this setting, limitations regarding accessibility and acquisition of medical resources and equipment for these types of operations may be difficult in developing countries. We believe the dexterities of surgeons go beyond the surgical technique, meaning that we are able to use everyday materials to re-create affordable solutions that can be used during surgery in a safe way. This manuscript presents our experience with different surgical instruments and gadgets, developed out of necessity, to improve microsurgical interventions in developing countries.

Usefullness with 3D CT Angiography in Microsurgical Reconstruction (미세수술을 이용한 하지의 재건시 삼차원 컴퓨터 혈관조영술의 유용성)

  • Sung, Yong Duck;Kim, Hyo Heon
    • Archives of Plastic Surgery
    • /
    • v.33 no.2
    • /
    • pp.175-180
    • /
    • 2006
  • Preoperative angiography is frequently used in the planning of microsurgical reconstruction for identification of vascular abnormality that influence the planning of operation. But, recently 3D CT angiography is considered as new technique that can provide detailed information about vascular anatomy as well as soft and bony tissue without the risks of invasive angiography. 3D CT angiograms were performed in 19 patients before microsurgical reconstruction for the lower extremity and hand between May of 2003 and Oct of 2004. Sixteen of the studies were of the donor site and all of 19 studies were of the recipient site. No complications were found from the 3D CT angiograms. In one case of the bone exposed open wound, the injury of anterior tibial artery was identified and the zone of injury was adequately demonstrated. With the improvement in quality of CT imaging, 3D CT angiograms may provide a favorable alternative to invasive angiography. It is capable of providing high-resolution, three dimensional vascular imaging without the need for arterial puncture and prolonged post-procedure observation. The relation among blood vessels, bones, and soft tissue is well demonstrated in 3D CT angiogram. Also The acquisition time and examination cost were considerably lower in comparison with invasive angiography. In conclusion, this study demonstrates that 3D CT angiography may provide accurate, safe, and cost-effective preoperative imaging. The 3D CT angiography with relatively low morbidity, low cost, ease of image acquisition can have an broader role in microsurgical reconstructive surgery.

Dye-Perfused Human Placenta for Simulation in a Microsurgery Laboratory for Plastic Surgeons

  • Laura C. Zambrano-Jerez;Karen D. Diaz-Santamaria;Maria A. Rodriguez-Santos;Diego F. Alarcon-Ariza;Genny L. Melendez-Florez;Monica A. Ramirez-Blanco
    • Archives of Plastic Surgery
    • /
    • v.50 no.6
    • /
    • pp.627-634
    • /
    • 2023
  • In recent decades, a number of simulation models for microsurgical training have been published. The human placenta has received extensive validation in microneurosurgery and is a useful instrument to facilitate learning in microvascular repair techniques as an alternative to using live animals. This study uses a straightforward, step-by-step procedure for instructing the creation of simulators with dynamic flow to characterize the placental vascular tree and assess its relevance for plastic surgery departments. Measurements of the placental vasculature and morphological characterization of 18 placentas were made. After the model was used in a basic microsurgery training laboratory session, a survey was given to nine plastic surgery residents, two microsurgeons, and one hand surgeon. In all divisions, venous diameters were larger than arterial diameters, with minimum diameters of 0.8 and 0.6 mm, respectively. The majority of the participants considered that the model faithfully reproduces a real microsurgical scenario; the consistency of the vessels and their dissection are similar in in vivo tissue. Furthermore, all the participants considered that this model could improve their surgical technique and would propose it for microsurgical training. As some of the model's disadvantages, an abundantly thick adventitia, a thin tunica media, and higher adherence to the underlying tissue were identified. The color-perfused placenta is an excellent tool for microsurgical training in plastic surgery. It can faithfully reproduce a microsurgical scenario, offering an abundance of vasculature with varying sizes similar to tissue in vivo, enhancing technical proficiency, and lowering patient error.

Microsurgical Replantation of Very Distally Amputated Finger (수지 첨부 절단의 재접합술)

  • Kang, Hong-Dae;Kim, Johng-Jin;Lee, Nae-Ho;Yang, Kyung-Moo;Moon, Ji-Hyun
    • Archives of Reconstructive Microsurgery
    • /
    • v.16 no.2
    • /
    • pp.75-81
    • /
    • 2007
  • Introduction: Microsurgical replantation of amputated digit have become common procedure in recent years. However replantation of fingertip amputation, Zone I by Yamano classification, is still difficult because digital arteries branch into small arteries and also digital veins are hard to separate from the immobile soft tissue. So, fingertip amputation was covered by volar V-Y flap, composite graft, cross finger flap and groin flap. But patients who have been treated by these methods experience shortening of digit, nail deformity, excessive tenderness and persistent pain. Replantation could solve most of these problems. Material & Methods: In our department, from March 2004 to August 2007, 36 digits in 32 patients with complete amputation at distal to nail base were replanted using a microsurgical technique. Results: The overall survival rate of the replanted finger was 75%. Venous anastomosis was possible in 8 cases and impossible in 28 cases. In latter cases external bleeding technique was applied with medical leech. Conclusion: After replantation, a few patient complained decreased sensibility, nail deformity and cold intolerance. But most of patients were satisfied with the functional and cosmetic appearance of the viable replanted digits. We believe the replantation should be the first choice in fingertip amputation.

  • PDF

Microsurgical Training using Reusable Human Vessels from Discarded Tissues in Lymph Node Dissection

  • Ishii, Naohiro;Kiuchi, Tomoki;Oji, Tomito;Kishi, Kazuo
    • Archives of Plastic Surgery
    • /
    • v.43 no.6
    • /
    • pp.595-598
    • /
    • 2016
  • The use of human vessels at the beginning of microsurgery training is highly recommended. But vessels with the appropriate length for training are not often obtained. Whether these vessels may be reused for training has not been reported. Accordingly, we harvested vessels from discarded tissues in lymph node dissection and demonstrated that vascular anastomosis training using the same human vessels several times is possible by placing the vessels in a freezer and defrosting them with hot water. Vascular walls can be stored for microsurgical training until about 4 years after harvest, as shown in the gross appearance and histologic findings of our preserved vessels. We recommend the technique presented here for the long-term reuse of human vessels for microsurgery training that closely resembles real procedures.

FABRICATION OF NEO-OSSEOUS FLAP USING DEMINERALIZED ALLOGENEIC BONE (탈회동종골을 이용한 신혈류화골판 형성에 관한 연구)

  • Lee, Jong-Ho;Kim, Hyeon-Tae
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.17 no.3
    • /
    • pp.253-263
    • /
    • 1995
  • Microsurgical vascularized bone transfer has the disadvantages of limitation of available donor sites, loss of donor function, and the possibility of donor site defects or deformity. To overcome these shortage of current microsurgical tissue transfer, the method of creating the neovascularized free flap has been introduced. Potentially, this technique must be an innovation in providing the free vascularized bone grafts that are not limited by natural vascular anatomy. But, as could be imagined technique resulted in unavoidable donor bone defect and additional operation for harvesting the autologous bone. The purpose of this study was to evaluate the efficacy of demineralized allogeneic bone as a possible substitute for autologous bone in fabricating the neo-osseous flap. By histologic, microangiographic and radioisotope method, the viability and vascularity of neo-osseous flap, which has been fabricated using allogeneic bone or autologous bone, was assessed in rat model. After 6 weeks, demineralized allogeneic bone showed consistent bone formation and neovascularization. The clinical and microscopic findings of demineralized allogeneic bone group were inferior to those of autogenous bone with regard to bone regeneration. The amount of bone blood floow per dry weight of demineralized allogeneic bone group was significantly higher than that of autogenous bone, even higher that of control intact iliac bone. In conclusion, findings supported that allogeneic bone could be the potential substitute for autologous bone source in creating a prefabricated neo-osseous flap.

  • PDF

Lymphovenous anastomoses with three-dimensional digital hybrid visualization: improving ergonomics for supermicrosurgery in lymphedema

  • Will, Patrick A.;Hirche, Christoph;Berner, Juan Enrique;Kneser, Ulrich;Gazyakan, Emre
    • Archives of Plastic Surgery
    • /
    • v.48 no.4
    • /
    • pp.427-432
    • /
    • 2021
  • The conventional approach of looking down a microscope to perform microsurgical procedures is associated with occupational injuries, anti-ergonomic postures, and increased tremor and fatigue, all of which predispose microsurgeons to early retirement. Recently, three-dimensional (3D) visualization of real-time microscope magnification has been developed as an alternative. Despite its commercial availability, no supermicrosurgical procedures have been reported using this technology to date. Lymphovenous anastomoses (LVAs) often require suturing vessels with diameters of 0.2-0.8 mm, thus representing the ultimate microsurgical challenge. After performing the first documented LVA procedure using 3D-augmented visualization in our unit and gaining experience with this technique, we conducted an anonymized in-house survey among microsurgeons who had used this approach. The participants considered that 3D visualization for supermicrosurgery was equivalent in terms of handling, optical detail, depth resolution, and safety to conventional binocular magnification. This survey revealed that team communication, resident education, and ergonomics were superior using 3D digital hybrid visualization. Postoperative muscle fatigue, tremor, and pain were also reduced. The major drawbacks of the 3D visualization microscopic systems are the associated costs, required space, and difficulty of visualizing the lymphatic contrast used.

The Free Vascularized Groin Flap for the Reconstruction of Extremity (사지재건을 위한 서혜부 유리피부편 이식술)

  • Hahn, Soo-Bong;Park, Young-Hee;Kang, Ho-Jung
    • Archives of Reconstructive Microsurgery
    • /
    • v.7 no.1
    • /
    • pp.1-9
    • /
    • 1998
  • From January 1985 to February 1997, 96 patients had undergone the free vascularized groin flap on the upper and lower extremities with microsurgical technique at the department of orthopaedic surgery, Yonsei University College of Medicine. The results were as follows: 1. Average age at the time of operation was 24.9 years. and there were 71 men and 25 women and mean follow up was 62.4 months. 2. The lesion site was 82 cases on the lower extremity: foot(40), leg(20), ankle(13), and 14 cases on the upper extremity: forearm(6), elbow(3), hand(3), wrist(2). 3. The anatomical classification of the superficial circumflex iliac artery was as follows: 1) 39.8% of common origin with superficial inferior epigastric artery, 2) 30.1% of isolated origin and absent superficial inferior epigastric artery, 3) 13.3% of separate origin, 4) 16.9% of origin from the deep femoral artery. 4. There was no statistical significance on arterial anastomosis between end to end and end to side, and on venous anastomosis(end to end) between one vein and two veins. 5. The success rate was average 84.4% in 81 of 96 cases. 6. In the 15 failed cases, the additional procedures were performed: 5 cases of free vascularized scapular flap, 6 cases of full thickness skin graft, 2 cases of cross leg flap, 1 case of latissimus dorsi flap, 1 case of split thickness skin graft. In conclusion, the free vascularized groin flap can be considered as the treatment of choice for the reconstruction of the extensive soft tissue injury on the extremities, and show the higher success rate with the experienced surgeon.

  • PDF