• Title/Summary/Keyword: Microstrp-line impedance transformer

Search Result 1, Processing Time 0.013 seconds

Measurement method of the signal transfer characteristic(S21) of the impedance transformer (임피던스 변환회로의 신호 전달특성(S21) 측정 방법)

  • Park, Ung-hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.10
    • /
    • pp.1282-1289
    • /
    • 2019
  • In order to measure the transfer characteristic(S21) of the impedance transformer, two impedance transformers must be symmetrically connected. However, the transfer characteristic of two symmetrically connected impedance transformers is influenced by the length of the intermediate connection line. This paper theoretically examines closely the length of the intermediate connection line to obtain the accurate transfer characteristic of the impedance transformer. The electrical length of the intermediate connection line for obtaining the accurate transfer characteristic of the 4:1(50-Ω:12.5-Ω) impedance transformer is calculated about 45°. Using the calculated length of the connection line, The λ/4-microstrip impedance transformer is fabricated at 1 GHz to measure the transfer characteristic. The symmetrically connected impedance transformer is measured the reflection characteristic(S11) of -40.64dB and the transfer characteristic(S21) of -0.154dB at 0.980GHz. This value is approximately equal to the theoretical calculated 987MHz center frequency and -0.15dB transfer loss value of the λ/4-microstrip impedance transformer.