• Title/Summary/Keyword: Microscopic observation

Search Result 708, Processing Time 0.03 seconds

ATOMIZATION PROCESS OF DIESEL FUEL SPRAY IN THE INITIAL STAGE OF INJECTION

  • KO K. N.;LEE C. S.;HUH J. C.
    • International Journal of Automotive Technology
    • /
    • v.6 no.1
    • /
    • pp.9-14
    • /
    • 2005
  • An experimental investigation has been carried out to reveal the atomization process of the diesel fuel spray. The spray injected through a single hole nozzle was taken by a camera on the opposite side of a stroboscope for macroscopic observation or a nanolite for microscopic observation. The effect of nozzle aspect ratio was analyzed with disintegration phenomena of the diesel spray. Based on the enlarged spray photograph, atomization process was observed in detail and further the spray cone angle was measured under various ambient pressures. The result shows that atomization of diesel spray in early stage of injection is mainly progressed in the vicinity of spray periphery region except the region close to the nozzle exit and spray head region. The spray cone angle is nearly constant under the pressurized condition, while it decreases with elapsing time under the atmospheric condition.

MICROSCOPIC OBSERVATION OF DRAPED COMPOSTTE MATERIALS : Picture Frame Test (직물 복합재료의 드레이핑 미소 거동 관찰: 사진틀 전단실험)

  • Kang Jae-Hoon;Chang Seung-Hwan
    • Composites Research
    • /
    • v.18 no.2
    • /
    • pp.13-19
    • /
    • 2005
  • In this paper deformation of micro-mechanical parameters such as tow interval, tow thickness and change in tow amplitude are investigated by using dry fabrics (Five-harness satin weave) under shear deformation. To evaluate the observation results according to the generated in-plane forces in the material, bias extension, biaxial test results are compared with. It was found that a picture frame test with a misaligned fibre orientation angle shows large differences in deformation between tensile and compressive tow directions.

Artifacts Frequently Encountered in Electron Micrographs (생물시료의 전자현미경 시료 제작 및 관찰 과정에서 발생되는 인공물)

  • Park, Chang-Hyun;Cho, Kang-Yong;Uhm, Chang-Sub
    • Applied Microscopy
    • /
    • v.35 no.1
    • /
    • pp.1-13
    • /
    • 2005
  • Fine photographs are essential in the electron microscopy. Artifacts can be introduced during all steps of electron microscopy; specimen processing, observation and printing. Every caution is necessary to avoid the artifact formation. In this review, the authors discussed the causes of various artifacts and suggested the solution to help the correct tissue handling and electron microscopic observations.

Electrical and optical characteristics AZO transparent conductivity thin films by solid state diffusion method (고상확산법에 의해 제조된 AZO 투명전도막의 전기-광학특성)

  • Lim, Kwang-Soo;Pyo, Jin-Gu;So, Soon-Jin;Park, Choon-Bae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.785-787
    • /
    • 2002
  • Conductivity and transmittancy of ZnO is very excellent and the price is low. So the study of transparent electrode materials and electromagnetic wave shielding wall is actively in progress. We add $Al_2O_3$(0.0, 2.0, 3.0, 5.0wt%) to ZnO and observe microscopic structure and conductivity. For XRD observation, Al peak of AZO is increased by increasing the amount of $Al_2O_3$. We observe that the size of grain is reduced by increasing the liquid phase of grain boundary to SEM observation. Conductivity of AZO is increased by increasing the amount of $Al_2O_3$. We confirm the application possibility of the materials for electromagnetic wave reflection materials.

  • PDF

The damage diagnosis and countermeasure of rolling stock parts (전동차부품의 손상진단 및 그 대책)

  • Park, Soo-Choong;An, Young-Whan;Lim, Sang-Yoon
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1626-1630
    • /
    • 2007
  • This dissertation finds out trouble types and occurrence regions using the faulty statistics of nondestructive test items in rolling stock parts of the Seoul Metro and using mechanical test about defective and broken parts with broken surface observation, cutting examination about trouble region, hardness experiment and tensile test. Also this dissertation finds out cause of trouble and damage through observation of microscopic formation using metallurgical microscope and scanning electron microscope, residual stress measurement about welding parts and damage diagnosis about defective and broken parts. Moreover it will present the improved plan of nondestructive method about trouble and the removal method of defect and repair welding and find solutions of reliability in parts and preventive maintenance.

  • PDF

Pharmacognostical Studies on Alisma Plants (택사의 생약학적 연구)

  • Toh, Chung-Ae
    • Korean Journal of Pharmacognosy
    • /
    • v.26 no.4
    • /
    • pp.411-418
    • /
    • 1995
  • In order to clarify the originality of several Alisma Rhizomes, we investigated the differences of their morphological, anatomical and physiochemical characteristics. Morphological observation shows the variability of Alisma shape and quality. The diversities in morphological shapes and qualities of tuber were observed among different origins. Chinese product looked like corm shape, but korean's irregular shape. The microscopic observation of korean Alisma revealed the presence of irregular vascular bundle which was scattered transversely and longitudinaly, which was different from that of the rhizome. This facts suggest that the portion of crude drug in Alisma should be the corm rather than the rhizome. In the physicochemical differences, chinese Alisma contains larger amount of mineral elements such as K, Na and Ca than korean Alisma. On the contrary, protein contents in lyophilized powder of aqueous extracts in korean Alisma rhizome was significantly higher than chinese Alisma rhizome. The leaves and stems contained larger amount of Ca and Na than tuber, and may be used as the osmotic diuretics for chinese traditional medicine.

  • PDF

Microscopic Surface Dynamics Studied by Scanning Probe Microscopy

  • Gwon, Gi-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.111-111
    • /
    • 2011
  • Arrangement of individual atoms and molecules with atomic precision and understanding the resulting properties at the molecular level are ultimate goals of chemistry, biology, and materials science. For the past three decades, scanning probe microscopy has made strides towards these goals through the direct observation of individual atoms and molecules, enabling the discovery of new and unexpected phenomena. This talk will discuss the origin of forces governing motion of small organic molecules and their extended self-assembly into two-dimensional surface structures by direct observation of individual molecules using scanning tunneling microscopy (STM). In addition, atomic force microscopy (AFM) is utilized for the investigation of fundamental mechanisms of bone mineral dissolution by examining atomically well characterized simulated bone minerals under aqueous solution environments.

  • PDF

Evaluation and monitoring of degradation mechanism of Li-ion battery for portable electronic device (휴대전자기기용 저용량 리튬이온 배터리의 충방전 열화 기구 분석 및 모니터링)

  • Byeon, Jai Won
    • Journal of Applied Reliability
    • /
    • v.13 no.2
    • /
    • pp.129-140
    • /
    • 2013
  • As a fundamental experimental study for reliability improvement of lithium ion secondary battery, degradation mechanism was investigated by microscopic observation and acoustic emission monitoring. Microstructural observation of the decomposed battery after cycle test revealed mechanical and chemical damages such as interface delamination, microcrack of the electrodes, and solid electrolyte interphase (SEI). Acoustic emission (AE) signal was detected during charge and discharge of lithium ion battery to investigate relationships among cumulative count, discharge capacity, and microdamages. With increasing number of cycle, discharge capacity was decreased and AE cumulative count was observed to increase. Observed damages were attributed to sources of the detected AE signals.

Development of an Error-Type Analysis Frame and Analysis of High School Students' Error-Types in Observation Behavior Using Microscopes (고등학생의 현미경 관찰 활동에 대한 결과 보고 오류 유형 분석틀의 고안 및 오류 유형 분석)

  • Jin, Hyun-Jung;Lee, Il-Sun;Kwon, Yong-Ju
    • Journal of Science Education
    • /
    • v.35 no.2
    • /
    • pp.127-137
    • /
    • 2011
  • The purpose of this study is to develop the analysis frame of reporting observation results by high school students in biology experiments using microscopes and analyze their error types. For this study, five experiments were carried out by 12 high school students in B metropolitan city. Before these experiments, developed the analysis frame of reporting observation results. Tests for checking prior knowledge of students were done and results of each experiment were taken picture of. Using the developed framework, the real results and reported results submitted by students were analyzed. The result of this study shows how students report their observation results and they tend to have difficulty in doing observation activity itself. The ratio of factual reports is low because observation ways and recording ways have not been taught properly. Observation training is needed for observing real results objectively. The improvement in experiment environment is necessary for right observation, not observation for checking based on only results. In addition, the education of ethics in science research focusing on the integrity should be performed. The analysis data of reporting observation result by students can be used as basic data for teachers to plan observation strategies and to have right observation views and ways.

  • PDF

Histological Observation of Embryogenic and Non-embryogenic Callus in Long-term Subculture of Wild Viola (Viola patrinii DC.) (흰제비꽃 배양세포에 있어서 분화세포와 미분화세포 조직의 비교 관찰)

  • 정용모;손병구;이재헌;서정해;정정한;권오창
    • Korean Journal of Plant Tissue Culture
    • /
    • v.27 no.3
    • /
    • pp.233-238
    • /
    • 2000
  • To obtain a basic information of the development of Genus Viola, morphological and histological observation of in vitro calli and cells in Viola culture cells were investigated. There were two callus types obtained by long term subculture of wild viola (Viola partrinii DC. ) petiole callus. One was friable callus - soft and pale green in color and small cells in size, and the other was compact callus - compact and deep bluish green in color, large cells in size. In scanning electron microscopic observation, friable callus was composed of voculated cell around small. cell clump, while compact callus was composed of cells filled with protoplasm Somatic embryogenesis was observed from suspension culture of the compact callus.

  • PDF