• Title/Summary/Keyword: Microscopic image

Search Result 199, Processing Time 0.027 seconds

The Study of Hanji and Washi Fiber Orientation using Image analysis (Image analysis에 의한 한지와 화지의 섬유 배향성 연구)

  • Han, Yoon-Hee;Enomae, Toshiharu;Isogai, Akira
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2006.11a
    • /
    • pp.89-96
    • /
    • 2006
  • To estimate the manufacturing district and generation of ancient paper as a cultural property, fiber orientation is one of the criteria. Image analysis using fast Fourier transform with suitable modifications was demonstrated to be an effective means to determine angle and intensity of fiber orientation as a nondestructive method. Binarization process of microscopic images of paper surface and precise calculation for average Fourier coefficients as an angular distribution by linear interpolation were newly introduced in the procedures to improve the accuracy. This analysis method was applied to digital optical micrographs of paper surfaces. Korea and Japanese traditional hand making papers were well distinguished. Korea and Japanese papers made in the traditional ways showed its own characteristic orientation behavior in accordance with the motion of a bamboo wire.

  • PDF

A Systematic Review of Trends for Image Quality Improvement in Light Microscopy (광학 현미경 영상 화질개선의 추세에 관한 체계적 고찰)

  • Kyuseok Kim;Youngjin Lee
    • Journal of radiological science and technology
    • /
    • v.46 no.3
    • /
    • pp.207-217
    • /
    • 2023
  • Image noise reduction algorithm performs important functions in light microscopy. This study aims to systematically review the research trend of types and performance evaluation methods of noise reduction algorithm in light microscopic images. A systematic literature search of three databases of publications from January 1985 to May 2020 was conducted; of the 139 publications reviewed, 16 were included in this study. For each research result, the subjects were categorized into four major frameworks-1. noise reduction method, 2. imaging technique, 3. imaging type, and 4. evaluation method-and analyzed. Since 2003, related studies have been conducted and published, and the number of papers has increased over the years and begun to decrease since 2016. The most commonly used method of noise reduction algorithm for light microscopy images was wavelet-transform-based technology, which was mostly applied in basic systems. In addition, research on the real experimental image was performed more actively than on the simulation condition, with the main case being to use the comparison parameter as an evaluation method. This systematic review is expected to be extremely useful in the future method of numerically analyzing the noise reduction efficiency of light microscopy images.

컴퓨터 영상처리에 의한 윤활시스템의 상태진단

  • 서영백;박흥식;전태옥;이충엽
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1997.04a
    • /
    • pp.224-231
    • /
    • 1997
  • Microscopic examination for the morphological estimation of wear debris on the oil-lubrcated moving system is an accepted method for machine condition and fault diagnosis. However wear particle anaysis has not been widely accepted industry because it is dependent on expert interpretation of particle morphology and relies on subjective assessment criteria. This paper was undertaken to estimate the morphology of wear debris on the oil-lubricated movig system by computer image analysis. The wear test was performed under different sliding conditions using a wear test device made in our laboratory and wear testing specimen of the pin-on-disk-type was rubbed in pararline series base oil. In order to describe characteristics of debris of various shape and size, four shape parameters (50% volumetric diameter, aspect, roundness and reflectivity) have been developed and outlined in the paper. A system using such techniques promises to obviate the need for subjective, human interpretation of particle morphology in machine condition monitoring.

  • PDF

Flow Visualization around the Endothelial Cell Model by the PIV System (입자영상유속계를 이용한 혈관내피세포 모형 주위의 유동가시화)

  • Roh, Hyung-Woon;Suh, Sang-Ho;Yoo, Sang-Sin
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.381-384
    • /
    • 2000
  • Relationships between biochemical phenomena and hemodynamics on human endothelial cells are very important to study the mechanism of atherosclerotic formation and development. The objective of this study is to investigate the flow phenomena around the endothelial cell model by the PIV experiment. The microscopic images of endothelial cells were acquired by a CCD camera to fabricate the shape of endothelial cell. The cell models were fabricated by using a photoforming process. Two consecutive particle images were captured by the CCD camera for the image processing. Conifer powder as the tracing particles was added to water to visualize the flow field. The cross-correlation method was applied fer the image processing of the flow visualization. Pressure and wall shear stress variations on the surfaces of the endothelial cells were calculated to investigate the effects of hemodynamic forces on the morphological changes.

  • PDF

CCD Scanning type MTF Measuring System for Microlens Arrays (CCD를 이용한 미세렌즈의 MTF 측정)

  • 이윤우;조현모;이인원;박태호;윤성균;서형원
    • Korean Journal of Optics and Photonics
    • /
    • v.5 no.3
    • /
    • pp.364-371
    • /
    • 1994
  • Real-time MTF measuring system for testing microlens arrays with a linear CCD array is developed. The spread function of slit image that is relayed and magnified by a microscopic object lens can be measured at several times in a second. The signal uniformity and MTF of CCD is also calibrated. The experimental result of micro lens arrays developed for contact image sensor is presented.sented.

  • PDF

Dimensions of Structural Elements in Fusiform Ray of Sitka Spruce (Picea sitchensis (Bong.) Carr.) Affecting Radial Permeability

  • Usta, Ilker
    • Journal of the Korean Wood Science and Technology
    • /
    • v.33 no.5 s.133
    • /
    • pp.1-6
    • /
    • 2005
  • The anatomical structure of fusiform ray was examined by scanning electron microscopy (and microscopic images were analysed by image analyser) to explain the differences in radial fluid uptake between the extremes in the radial treatment data, i.e. between the selected trees of QCI (Queen Charlotte Islands in Rhondda, South Wales) and SO (South Oregon in Dalby, North-East England) planted in the UK. The ray structure of these two seed origins was examined microscopically and different patterns of ray composition were observed. The most important anatomical features influencing radial permeability were the nature of fusiform ray, and the condition of the resin canals, epithelial cells and intercellular spaces in particular.

Computer Vision System for Analysis of Geometrical Characteristics of Agricultural Products and Microscopic Particles (I) -Algorithms for Automatic Threshold Selection- (농산물 및 미립자의 기하학적 특성 분석을 위한 컴퓨터 시각 시스템(I) -자동(自動) 문턱값 설정(設定) 알고리즘-)

  • Lee, J.W.;Noh, S.H.
    • Journal of Biosystems Engineering
    • /
    • v.17 no.2
    • /
    • pp.132-142
    • /
    • 1992
  • The main objective of this paper is to evaluate and modify the existing algorithms for the automatic threshold selection. Four existing algorithms were evaluated quantitatively using test images of coffee droplets and an apple. The images had the different area ratio of the object to the image size, different average gray values between the object and the background, and different S/N ratio of the Gaussian noise. The result showed that Histogram Clustering Method and Maximum Entropy Method were better than Moment Preserving Method and Simple Image Statistic Method in automatic thresholding.

  • PDF

Detection of Gastrointestinal Cancer using Linked Color Imaging and Blue Light Imaging (위장관암 발견에 있어 Linked Color Imaging와 Blue Light Imaging의 유용성)

  • Yoo, In Kyung;Cho, Joo Young;Osawa, Hiroyuki
    • Journal of Digestive Cancer Reports
    • /
    • v.7 no.2
    • /
    • pp.31-39
    • /
    • 2019
  • The early detection of early gastric cancer (EGC) is important. However, the sensitivity of conventional white light imaging (WLI) in detecting EGC had been reported to range only from 77% to 84%. Although the resolution of endoscopes has been remarkably developed, precancerous lesions such as adenomas and microscopic early cancers are difficult to diagnose with general endoscopy. Linked Color Imaging (LCI) magnifies the differences in color for easy detection. Therefore, it produces a bright image from a distance and is performed for screening endoscopy. The 410 nm wavelength of BLI (Blue Light Imaging) helps to detect cancer by showing microstructure and microvessels in the mucosal superficial layer. This review will focus on the utility of Image enhanced endoscopy (IEE) techniques in diagnosis of gastrointestinal cancer.

Electron Microscopy and MR Imaging Findings in Embolic Effects

  • Park Byung-Rae;Koo Bong-Oh
    • Biomedical Science Letters
    • /
    • v.10 no.4
    • /
    • pp.367-373
    • /
    • 2004
  • Evaluated the hyperacute embolic effects of triolein and oleic acid in cat brains by using MR image and electron microscopy. In fat embolism, free fatty acid is more toxic than neutral fat in terms of tissue damage. T2-Weighted imaging, diffusion-weighted imaging, and contrast-enhanced T1-weighted imaging were performed in cat brains after the injection of triolein (group 1, n=8) or oleic acid (group 2, n=10) into the internal carotid artery. MR image were quantitatively assessed by comparing the lesions with their counterparts on T2-weighted images, apparent diffusion coefficient (ADC) maps, and contrast-enhanced T1-weighted images. Electron microscopic findings in group 1 were compared with those in group 2. Qualitatively, MR images revealed two types of lesions. Type 1 lesions were hyperintense on diffusion-weighted images and hypointense of ADC maps. Type 2 lesions were isointense or mildly hyperintense on diffusion-weighted images and isointense on ADC maps. Quantitatively, the signal intensity rations of type 1 lesions in group 2 specimens were significantly higher on T2-weighted images (P=.013)/(P=.027) and lower on ADC maps compared with those of group 1. Electron microscopy of type 1 lesions in both groups revealed more prominent widening of the perivascular space and swelling of the neural cells in groups 1. MR and electron microscopic data on cerebral fat embolism induced by either triolein or oleic acid revealed characteristics suggestive of both vasogenic and cytotoxic edema in the hyperacute stage. Tissue damage appeared more severe in the oleic acid group than in the triolein group.

  • PDF

The Physiological and Biochemical Studies of Nocardia sp (Part I) Cell Fine Structure of Nocardia sp (Nocardia sp의 생이생화학적연구 (제1보) Nocardia sp의 미세구조에 관하여)

  • 홍순덕
    • Microbiology and Biotechnology Letters
    • /
    • v.5 no.3
    • /
    • pp.133-140
    • /
    • 1977
  • The results of electron microscopic studies on the cell fine structure of Nocardia sp the location of tellurite-reducing enzyme and the reduction part of T. T. C. (Triphenyl tetrazonium chloride) were summarized as follows. As the fine structure of the cell, the membrane-like structure with unit membrane was distributed in the cytoplasm. The membrane-like structure had complicate forms: some of membrane-like structure appeared spiral form. As the metal tellurium salt appeared in the cytoplasm, it is obvious that tellurite and tellurate-reducing enzymes are present in the cytoplasm. Reduction of T. T. C. took place in the cell membrane and the intracellular membrane-like structure. Therefore, it was thought that reduction of tellurate and T. T. C. took place in different parts. T. T. C. formazane formed in the cell was reoxidized by osmic acid which was used as a fixation reagent for the electron microscopic specimen preparation. As 95% T. T. C. formazane was soluble in ethanol and embedding materials and removed out of the cell, an originally formed formazane appeared as electron light part on the electron microscopic image.

  • PDF