• Title/Summary/Keyword: Microscope

Search Result 8,084, Processing Time 0.03 seconds

Effects of Electroplating Condition on Micro Bump of Multi-Layer Build-Up PCB (다층 PCB 빌드업 기판용 마이크로 범프 도금에 미치는 전해조건의 영향)

  • Seo, Min-Hye;Hong, Hyun-Seon;Jung, Woon-Suk
    • Korean Journal of Materials Research
    • /
    • v.18 no.3
    • /
    • pp.117-122
    • /
    • 2008
  • Micro-sized bumps on a multi-layered build-up PCB were fabricated by pulse-reverse copper electroplating. The values of the current density and brightener content for the electroplating were optimized for suitable performance with maximum efficiency. The micro-bumps thus electroplated were characterized using a range of analytical tools that included an optical microscope, a scanning electron microscope, an atomic force microscope and a hydraulic bulge tester. The optical microscope and scanning electron microscope analyses results showed that the uniformity of the electroplating was viable in the current density range of $2-4\;A/dm^2$; however, the uniformity was slightly degraded as the current density increased. To study the effect of the brightener concentration, the concentration was varied from zero to 1.2 ml/L. The optimum concentration for micro-bump electroplating was found to be 0.6 ml/L based on an examination of the electroplating properties, including the roughness, yield strength and grain size.

NANO-STRUCTURAL AND NANO-CHEMICAL ANALYSIS OF NI-BASE ALLOY/LOW ALLOY STEEL DISSIMILAR METAL WELD INTERFACES

  • Choi, Kyoung-Joon;Shin, Sang-Hun;Kim, Jong-Jin;Jung, Ju-Ang;Kim, Ji-Hyun
    • Nuclear Engineering and Technology
    • /
    • v.44 no.5
    • /
    • pp.491-500
    • /
    • 2012
  • The dissimilar metal joints welded between Ni-based alloy, Alloy 690 and low alloy steel, A533 Gr. B with Alloy 152 filler metal were characterized by using optical microscope, scanning electron microscope, transmission electron microscope, secondary ion mass spectrometry and 3-dimensional atom probe tomography. It was found that in the weld root region, the weld was divided into several regions including unmixed zone in Ni-base alloy, fusion boundary, and heat-affected zone in the low alloy steel. The result of nanostructural and nanochemical analyses in this study showed the non-homogeneous distribution of elements with higher Fe but lower Mn, Ni and Cr in A533 Gr. B compared with Alloy 152, and the precipitation of carbides near the fusion boundary.

A Flexure Guided Planar Scanner for Scanning Probe Microscope ; Part 2. Evaluation of Static and Dynamic Properties (주사 현미경용 평면 스캐너 Part 2 : 정 · 동 특성 평가)

  • Lee, Moo-Yeon;Gweon, Dae-Gab;Lee, Dong-Yeon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.11 s.104
    • /
    • pp.1295-1302
    • /
    • 2005
  • This paper shows experimental evaluation results of the nano-positioning planar scanner used in the scanning probe microscope. The planar scanner is composed of flexure guides, piezoelectric actuators and feedback sensors as like explained in detail in Ref. (5). First, the fabrication methods were explained. Second, as the static Properties of the Planar scanner. we evaluated the maximum travel range & crosstalk. Also, we presented the correcting method for crosstalk using electric circuits finally. as the dynamic properties of the planar scanner, we evaluated the first resonant frequency. Also, we presented the actual AFM(atomic force microscope) imaging results with up to 2Hz imaging scan rate. Experimental results show that properties of the proposed planar scanner are well enough to be used in SPM applications like AFM.

Suppression of Melanose Caused by Diaporthe citri on Citrus Leaves Pretreated with Bio-sulfur

  • Shin, Yong Ho;Ko, Eun Ju;Kim, Su Jeong;Hyun, He Nam;Jeun, Yong Chull
    • The Plant Pathology Journal
    • /
    • v.35 no.5
    • /
    • pp.417-424
    • /
    • 2019
  • Melanose, caused by Diaporthe citri, is one of severe diseases in citrus, a major economic resource in Jeju island. To reduce the usage amount of organic synthetic fungicide, bio-sulfur was tested as an alternative chemical to control citrus melanose in the present study. Direct antifungal activity of bio-sulfur against D. citri was determined through in vitro experiment using artificial nutrient media. Disease severity of melanose on bio-sulfur pretreated citrus leaves was lower than that on untreated ones. To illustrate the mechanism of disease suppression by bio-sulfur, infection structures were observed with a fluorescent microscope and a scanning electron microscope. In fluorescent microscopic observation, most conidia rarely germinated. In addition, hyphal growth on leaves pretreated with bio-sulfur was inhibited compared to that on untreated ones. In scanning electron microscope images of bio-sulfur pretreated leaves, surfaces of most conidia were shrunk while hyphae were morphologically changed and frequently branched. Such microscopic observations were also found for leaves pretreated with a commercial fungicide Dithianon. These results suggest that bio-sulfur may be used to control citrus melanose as an environment friendly alternative to organic synthetic fungicides

The construction of Accoustic Reflection Microscope and its application (반사형 음향 현미경의 구성과 그 응용)

  • 고대식
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1987.11a
    • /
    • pp.48-51
    • /
    • 1987
  • In this paper, acoustic reflection microscope system has been built for the purpose of detecting subsurface defects in materials and demonstrated for nondestructive testing application. 100 won coin, aluminuim, ceramics, and IC component employed as experimental samples and acoustic reflection microscope was operated in the focused and defocused mode at a frequency of operation of 3 MHz. It has been found that acoustic reflection icroscope has the resolution of 500 ${\mu}{\textrm}{m}$ and it has been an excellent tool for nondestructive testing.

  • PDF

Measuement of Apparent Contact Angle in Yarn Using Microscope (광학 현미경을 이용한 실에서의 접촉각 측정)

  • 오동원;이광배
    • Proceedings of the Korean Fiber Society Conference
    • /
    • 1997.04a
    • /
    • pp.127-133
    • /
    • 1997
  • Authors measured the apparent contact angle in a yarn using microscope because it gives a useful information in the evaluation of comfort factors in fabrics. The mechanical stage of microscope was designed and built to facilitate this measurement. Variables examined were the fiber type, the twisting number, and the fluid type. All produced significant effect most of which could be rationalized based on the known concepts. The methodology used and the results obtained are discussed in detail.

  • PDF

Application of dental microscope in endodontic treatment procedure. (근관치료 영역에서 치과용 미세현미경의 활용)

  • Choi, Sung Baik
    • The Journal of the Korean dental association
    • /
    • v.55 no.8
    • /
    • pp.542-555
    • /
    • 2017
  • 1. Diagnosis Diagnosis of Crack, Direct pulp capping 2. Access opening Find the calcified canal orifice Removal of dentin shelf Obtaining the MB2 canal (MB2, MB3, DB2) 3. Perforation repair during endodontic treatment 4. Removal of the separated files 5. Open apex treatment 6. Void removal on CWT procedure 7. Re-endodontic treatment Removal of restorative material filled in pulp chamber Post removal Identification and removal of residual gutta-perch 8. Surgical endodontic treatment In each case will overview how to use a dental microscope.

  • PDF

A Study on the Ignition and Molten Mark Analysis of Ballast for Fluorescent Lamp (형광등용 안정기의 발화 및 용융흔 분석에 관한 연구)

  • 최충석;박창수;김혁수;김향곤;정재희
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 1998.11a
    • /
    • pp.173-177
    • /
    • 1998
  • In this paper, we reported an outbreak of fire hazard of ballast for fluorescent lamp. The surface structure and composition of ballast coil analyzed by using metallurgical microscope, scanning electron microscope(SEM) and energy dispersive x-ray spectroscopy(EDX). The surface of molten mark appeared columnar structure and void. EDX analysis indicated that the molten mark spectra were composed not only of the corresponding original spectra but also of several new lines.

  • PDF

Imaging and Manipulation of Benzene Molecules on Si Surfaces Using a Variable-low Temperature Scanning Tunneling Microscope

  • Hahn, J. R.
    • Bulletin of the Korean Chemical Society
    • /
    • v.26 no.7
    • /
    • pp.1071-1074
    • /
    • 2005
  • A variable-low temperature scanning tunneling microscope (VT-STM), which operates from 77 to 350 K in ultrahigh vacuum, was built and used to study imaging and manipulation of benzene molecules on Si surfaces. Four types of benzene adsorption structures were first imaged on the Si(5 5 12)-2x1 surface. Desorption process of benzene molecules by tunneling electrons was studied on the Si(001)-2xn surface.

Angle-Resolved Photoemission Spectroscopy: Momentum-Space Microscope

  • Hwang, Chan-Cuk
    • Applied Microscopy
    • /
    • v.45 no.3
    • /
    • pp.115-118
    • /
    • 2015
  • In this review paper, I'd like to introduce the basics of angle-resolved photoemission spectroscopy (ARPES) and some of my results taken at the Pohang Accelerator Laboratory (PAL), the only synchrotron radiation in South Korea. The results show that ARPES is very useful, in particular, for studying two-dimensional materials. It looks like a microscope in momentum space similar to transmission electron microscope imaging atoms in real space.