• 제목/요약/키워드: Microrobot

검색결과 30건 처리시간 0.027초

전자기 구동 유영 마이크로로봇 (Swimming Microrobot Actuated by External Magnetic Field)

  • 변동학;김준영;백승만;최현철;박종오;박석호
    • 대한기계학회논문집A
    • /
    • 제33권11호
    • /
    • pp.1300-1305
    • /
    • 2009
  • The various electromagnetic based actuation(EMA) methods have been proposed for actuating microrobot. The advantage of EMA is that it can provide wireless driving to microrobot. In this reason a lot of researchers have been focusing on the EMA driven microrobot. This paper proposed a swimming microrobot driven by external alternating magnet field which is generated by two pairs of Helmholtz coils. The microrobot has a fish-like shape and consists of a buoyant robot body, a permanent magnet, and a fin. The fin is directly linked to the permanent magnet and the magnet is swung by the alternating magnet field, which makes the propulsion and steering power of the robot. In this paper, firstly, we designed the locomotive mechanism of the microrobot boy EMA. Secondly, we set up the control system. Finally, we demonstrated the swimming robot and evaluated the performance of the microrobot by the experiments.

Design of a Propagation Wave Type Microrobot for Moving on the Slippery Surface

  • Kim, Eui-Jin;Park, Jong-Hyeon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.2072-2077
    • /
    • 2003
  • Animal-like robots are serving an important role as a linkage between biology and engineering. So, in this paper, we aim to develop a biomimetic microrobot that mimics the locomotion mechanism of a gastropod. This microrobot has 3 DOF (x, y translation and rotation), and has small size, unlimited traveling range, high resolution and low cost. Its movement can be made using propagation wave that is generated by the controllable sinusoidal voltage source and piezoelectric effects. This soft motion that can be generated by propagation wave and piezoelectric mechanism would be useful for the motion on the slippery surface. So we modeled the propagation wave mechanism including piezoelectric effect and friction on the contact surface, and could know the velocity of the microrobot is dependent on the driving frequency, input voltage peak, propagation wavelength and surface friction coefficient. With these results we design the microrobot, and accomplish its fabrication and experimentation. The development of this microrobot shall be aimed to design an autonomous moving actuator like animal. Also it can be used from micromanipulation system technology to biology and medicine.

  • PDF

곤충 날개를 형상화한 마이크로로봇의 연구 (Study of Microrobot formed the Wing of a Insect)

  • 김종걸;이건영
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.424-424
    • /
    • 2000
  • The implementation of a insect-based flying microrobot has been previously proposed as using magnetic force. The flying principle of a butterfly is different from that of a airplane, which obtain lifting force above the wings by a air stream with low pressure. Butterflies obtain lifting force below the wings by flapping. They can fly when drag during the down stroke is greater that during the up stroke. The structure of flying microrobot must satisfy these condition. And that must be manufacture lightly and keep balance for rising to the air sufficiently. Moreover the efficiency of an electromagnet is high and the flux density is sustained uniformly and widely Nevertheless these condition is satisfied, the implementation of a flying microrobot is very difficult as the flying microrobot has to fly without guides or sensor. We propose differently a new model il] comparison with that other paper has suggested. This imitates the form of the Korean shield-shaped kite.

Multifunctional Robotic Guidewire System using Spiral-type Magnetic Microrobot with Magnetic Manipulation

  • Yu, Chang-Ho;Kim, Sung Hoon
    • Journal of Magnetics
    • /
    • 제21권4호
    • /
    • pp.616-621
    • /
    • 2016
  • This paper presents a new multifunctional active guidewire system for medical applications that uses a magnetic microrobot. The study demonstrated that the proposed microrobot system could swim and be controlled under Low-Reynolds-number (Re) environments in blood vessel models. The prototype of the robotic guidewire, which is driven within a three-axis Helmholtz coil system, consists of a guide-wire, spiral blade, drilling tip, and permanent magnet. The spiral-type microrobot showed stable active locomotion between 3 kA/m and 9.1 kA/m under driving frequency up to 70 Hz in a silicone oil (of viscosity 1000 cst). The microrobot produced a maximum moving velocity of $8.08{\times}10^{-3}m/s$ at 70 Hz and 9.1 kA/m. In particular, the robotic guidewire produced 3D locomotion with drilling in the three-axis Helmholtz coil system. We verified active locomotion, towing of guidewire, steering, and drilling of the proposed robotic guidewire system through experimental analyses.

초소형 로봇을 이용한 점도성 유체의 혼합 효율 향상 (Enhancement of Mixing Performance in Viscous Liquid Using an Electromagnetically Driven Microrobot)

  • 송현석;박유나;정상국
    • 한국가시화정보학회지
    • /
    • 제16권2호
    • /
    • pp.53-58
    • /
    • 2018
  • This paper presents an electromagnetically driven microrobot for the enhancement of mixing performance in high viscous liquid media such as blood and bone marrow. First, an electromagnetic system was fabricated, and the magnetic flux density generated from the system was compared with the theoretical value. Second, the reciprocating motion of the microrobot was demonstrated in microchannel using electromagnetic system. As a proof of concept, the mixing performance by the electromagnetically driven microrobot in high viscous liquid was investigated using safranin solution. As a result, it was completely mixed within 140 s with the reciprocating motion of the microrobot while it took 1680 s for natural diffusion. In addition, the mixing efficiency was quantitatively evaluated through a mixing index obtained by an image analysis. The proposed method provides not only wireless actuation of a microrobot with a simple design but also high mixing performance in variety of high viscous liquid media.

Compact 3-DOF Mobile Microrobot for Mirco/Nano Manipulation

  • Kim, Taesung;Park, Jungyul;Kim, Deok-Ho;Lee, Kyo-Il
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2002년도 ICCAS
    • /
    • pp.64.3-64
    • /
    • 2002
  • $\textbullet$ Introduction to 3-Dimensional Nanorobotic Manipulation System $\textbullet$ Concept Design and Operating Principle $\textbullet$ Analytic Model for target System $\textbullet$ Fabrication and Experimental Setup of 3-DOF Mobile Microrobot $\textbullet$ Experimental Works or 3-DOF Mobile Microrobot

  • PDF

캡슐형 내시경을 위한 체내 이동용 마이크로 로봇 (Locomotive Microrobot for Capsule Endoscopes)

  • 양성욱;박기태;이승석;나경환;김진석;최종호;박석호;박종오;윤의성
    • 로봇학회논문지
    • /
    • 제4권1호
    • /
    • pp.62-67
    • /
    • 2009
  • For diagnoses of digestive organs, capsule endoscopes are widely used and offer valuable information without patient's discomfort. A general capsule endoscope which consists of image sensing module, telemetry module and battery is able to move along gastro-intestinal tracts passively only through peristaltic waves. Thus, it is likely to have some limitations for doctor to acquire images from the desired organs and to diagnose them effectively. As solutions to these problems, a locomotive function of capsule endoscopes has being developed. We have proposed a capsule-type microrobot with synchronized multiple legs. However, the proposed capsular microrobot also has some limitations, such as low speed in advancement, inconvenience to controlling the microrobot, lack of an image module, and deficiency in a steering module. In this paper, we will describe the limitations of the locomotive microrobot and propose solutions to the drawbacks. The solutions are applied to the capsular microrobot and evaluated by in-vitro tests. Based on the experimental results, we conclude that the proposed solutions are effective and appropriate for the locomotive microrobot to explore inside intestinal tracts.

  • PDF

A Paddling Based Locomotive Mechanism for Capsule Endoscopes

  • Park Suk-Ho;Park Hyun-Jun;Park Sung-Jin;Kim Byung-Kyu
    • Journal of Mechanical Science and Technology
    • /
    • 제20권7호
    • /
    • pp.1012-1018
    • /
    • 2006
  • Diagnosis and treatment using the conventional flexible endoscope in gastro-intestinal tract are very common since advanced and instrumented endoscopes allow diagnosis and treatment by introducing the human body through natural orifices. However, the operation of endoscope is very labor intensive work and gives patients some pains. As an alternative, therefore, the capsule endoscope is developed for the diagnosis of digestive organs. Although the capsule endoscope has conveniences for diagnosis, it is passively moved by the peristaltic waves of gastro-intestinal tract and thus has some limitations for doctor to get the image of the organ and to diagnose more thoroughly. As a solution of these problems, various locomotive mechanisms for capsule endoscopes are introduced. In our proposed mechanism, the capsule-type microrobot has synchronized multiple legs that are actuated by a linear actuator and two mobile cylinders inside of the capsule. For the feasibility test of the proposed microrobot, a series of in-vitro experiments using small intestine without incision were carried out. From the experimental results, our proposed microrobot can advance along the 3D curved and sloped path with the velocity of about $3.29\sim6.26mm/sec$ and $35.1\sim66.7%$ of theoretical velocity. Finally, the proposed locomotive mechanism can be not only applicable to micro capsule endoscopes but also effective to advance inside of gastro-intestinal tract.

전자기 구동 시스템을 이용한 마이크로로봇의 3차원 이동 및 드릴링 (Three-dimensional Locomotion and Drilling Microrobot Using Electromagnetic Actuation System)

  • 이걸;최현철;차경래;정세미;박종오;박석호
    • 대한기계학회논문집A
    • /
    • 제35권12호
    • /
    • pp.1573-1578
    • /
    • 2011
  • 이 논문에서는 전자기구동시스템을 기반으로 이동 및 드릴링 기능을 수행하는 의료용 마이크로로봇 시스템을 제작하고 평가하였다. 마이크로로봇은 너무 작아 내부에 배터리나 제어장치를 삽입 할수 없다. 이 결점을 극복하기 위하여 외부에서 전자기 코일 시스템을 이용하여 전자기장의 힘으로 마이크로로봇을 구동 시킨다. 전자기 구동 코일 시스템은 x, y, z 각축에 사각형 타입의 헬름홀쯔 코일 3 쌍과 z축에 솔레노이드형 맥스웰 코일 1 쌍이 배치 되어 있고, 각 코일에 인가되는 전류값의 조절에 따라 구동에 필요한 자기장을 발생 시킨다. 다양한 실험을 통하여 우리는 제안된 시스템을 이용하여 마이크로로봇이 3 차원 공간에서 이동 가능하며 드릴링 기능을 수행할 수 있다는 것을 보였다.