• Title/Summary/Keyword: Micropump

Search Result 99, Processing Time 0.027 seconds

Performance Analysis of the Viscous-driven Micropump with Tandem Rotating Cylinders (한 쌍의 실린더를 가지는 점성구동 마이크로 펌프의 성능 해석)

  • Choi, Hyung-Il;Cho, Sung-Chan;Maeng, Joo-Sung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.9
    • /
    • pp.1256-1261
    • /
    • 2003
  • Since the viscous effect increases as the size of device decreases, viscous-driven micropump is a promising mechanism in microscale applications. In the present study, a dual-rotor type pump which contains two counter-rotating cylinders for improving performance characteristics is proposed. First, for flows in the single-rotor type pump, the present unstructured grid simulation method is validated by comparing its results to the previous results. Next, the performance of the dual-rotor type pump is evaluated by the parametric studies and is compared to that of the previous single-rotor type pump. The flow characteristics are qualitatively similar to those of single-rotor type pump. However, the performance of the micropump with tandem rotors is still better than that of previous pumping type, e.g. much larger flow rate, smaller driving region, higher efficiency, and wider operation range.

A Numerical Study on the Flow Characteristics of a Valveless Micropump (무밸브 마이크로 펌프의 유동 특성에 관한 수치해석)

  • Chin, Sang-Mun;Hur, Nahmkeon
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.748-753
    • /
    • 2004
  • The performance of a valveless micropump driven by chamber wall oscillation was numerically investigated for various frequency and amplitude of the oscillation. The numerical study was performed in the range of oscillation frequency from 200Hz to 1000Hz and amplitude from $1{\mu}m$ to $15{\mu}m$. And optimal values for the parameters are found. At the oscillation frequency 600Hz, the net flow rate of micropump shows a maximum value. Also the results show good agreement with the experimental results. The total flow rate was increased with the oscillation amplitude. However, the net flow rate was found to be decreased over $7{\mu}m$.

  • PDF

A Numerical Study on the Flow Characteristics of a Peristaltic Micropump (연동형 마이크로펌프의 유동에 대한 수치해석 연구)

  • Lee, Na-Ri;Lee, Sang-Hyuk;Hur, Nahm-Keon
    • The KSFM Journal of Fluid Machinery
    • /
    • v.12 no.4
    • /
    • pp.37-43
    • /
    • 2009
  • In the present study, the flow characteristics of a peristaltic micropump were numerically analyzed. A channel wall motion of the micropump was simulated using a moving mesh technique. A sine wave pattern was assumed to simulate the peristaltic motion of wall. The present numerical method was verified by comparing the result with the available numerical data. The effects of the operating conditions which include the maximum displacement and frequency of the channel wall and the phase difference between top and bottom walls on the flow characteristics were investigated. From these numerical results, the pressure-flowrate characteristic curve was obtained for various maximum displacement and frequencies.

Micro Cell Counter Integrated with An Oxygen Micropump (산소 미세 펌프가 내장된 미세 세포 계수기)

  • Son, Sang-Uk;Choi, Yo-Han;Lee, Seung-Seob
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.8 s.227
    • /
    • pp.1159-1165
    • /
    • 2004
  • This paper describes fabrication of a micro cell counter integrated with an oxygen micropump and counting experiment with Sephadex G-25 beads ($70{\sim}100\;{\mu}m$). The pumping part consisted of a microheater, catalyst (manganese dioxide) enveloped with paraffin, hydrogen peroxide, and microchannel, and the counting part consisted of collimated light, a microwindow, and a phototransistor including an external circuit. The micropump generated oxygen gas by decomposing hydrogen peroxide with manganese dioxide, which was initiated by melting the paraffin with the microheater, and pumped beads in the microchannel. When the beads passed the microwindow, they shaded the collimated light and changed the illumination on the phototransistor, which caused the current variation in the circuit. The signals, according to the bead size, reached up to 22 mV with noise level of 2 mV during 50 seconds and the numbers of peaks were analyzed by magnitude.

Design, fabrication and characterization of a flap valve mircopump using an ionic polymer-metal composite actuator (이온성 폴리머-금속 복합재료 작동층을 사용한 플랩 밸브 마이크로 펌프의 설계, 개발 및 특성 규명)

  • Nguyen, Thanh Tung;Nguyen, Vinh Khanh;Yoo, Young-Tai;Goo, Nam-Seo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.35 no.4
    • /
    • pp.302-307
    • /
    • 2007
  • In this paper, a flap valve micropump with an ionic polymer-metal composite (IPMC) actuator was designed, fabricated, and experimentally characterized. A multilayered IPMC based on Nafion/layered silicate and Nafion/silica nanocomposites was fabricated for the actuation section of the micropump. The IPMC diaphragm, a key element of the mircopump, was designed so that the IPMC actuator was supported by a flexible polydimethylsiloxane (PDMS) structure at its perimeter. This design feature enabled a significantly high displacement of the IPMC diaphragm. The overall size of the micropump is $20{\times}20{\times}5$ ${mm}^3$. Water flow rates of up to 760 ${\mu}l$/min and a maximum backpressure of 1.5 kPa were recorded. A significant advantage of the proposed micropump is its low driven voltage from only 1-3 V. In addition, a simple and effective design, and an ease of manufacturing are other advantages of the present micropump.

A Numerical Study on the Performance Characteristics of a Piezoelectric Micropump for Different Inlet and Outlet Positions (${\cdot}$출구 위치 변화에 따른 압전 구동방식 마이크로 펌프의 성능특성에 관한 수치해석적 연구)

  • Kim Dong Hee;Jeong Jin;Kim Chang Nyung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.1
    • /
    • pp.33-38
    • /
    • 2005
  • This study has been conducted to investigate flow characteristics of a micropump with piezoelectric materials. In this study, the change of flow rates has been investigated for different positions of the inlet and outlet and for different distances between them. The FSI(Fluid Structure Interaction) method has been employed for numerical analysis of the piezoelectric diffuser/nozzle based micropump. It has been found that time averaged flow rate is greater in the case that distance between the inlet and outlet is longer. For the cases where the positions of the inlet are different with the position of the fixed outlet at the center, the flow rate is increased as the inlet is located farther from the center. This study may supply fundamental understandings for the design and analysis of the prototypes of piezoelectric micropumps.

Development of having double-chamber in micro-bubble pump (두 개의 챔버를 갖는 마이크로 버블펌프의 개발)

  • 최종필;박대섭;반준호;김병희;장인배;김헌영
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1186-1190
    • /
    • 2003
  • In this paper, a valveless bubble-actuated fluid micropump was has been developed and its performance was tested. The valveless micropump consists of the lower plate, the middle plate, the upper plate and a resistive heater. The lower plate includes the nozzle-diffuser elements and the double-chamber. Nozzle-diffuser elements and a double-chamber are fabricated on the silicon wafer by the DRIE(Deep Reactive Ion Etching) process. The lower plate also has inlet/outlet channels for fluid flow. The middle plate is made of glass and plays the role of the diaphragm. The chamber in the upper plate is filled with deionized water, and which contacts with the resistive heater. The resistive heater is patterned on a silicon substrate by Ti/Pt sputtering. Three plates and the resister heater are laminated by the aligner and bonded in the anodic bonder. Since the bubble is evaporated and condensed periodically in the chamber, the fluid flows from inlet to outlet with respect to the diffusion effect. In order to avoid backflow, the double chamber system is introduced. Analytical and experimental results show the validity of the developed double-chamber micropump.

  • PDF

Development of the Portable Drug Delivery Systems with a Piezoelectric Micropump (압전 마이크로펌프 방식의 휴대용 약물전달장치 개발)

  • Kim, Sei Yoon;Kim, Young Tae;Seo, Hyun Bae
    • Journal of Drive and Control
    • /
    • v.12 no.4
    • /
    • pp.71-76
    • /
    • 2015
  • The therapy of injecting a fixed amount of a prescribed drug for a predetermined time is an effective treatment in relieving pain during anticancer treatments. Due to recent medical technology development, cancer is currently classified as a disease that can be managed in the patient's lifetime. If patients were able to use a drug delivery system that was portable, sustainable and had an accurate flow control, they would be able to inject medication whenever they need. In this study we developed a piezoelectric micropump for a drug delivery system by designing a pump chamber, check valve and diaphragm. We also developed a driving circuit that consumes low power and to which we applied a variety of signals. We fabricated a portable drug delivery system with this piezoelectric micropump and driving circuit. In addition, through a performance test, we confirmed that the system can precisely control the drug flow rate.