• Title/Summary/Keyword: Microporous

Search Result 258, Processing Time 0.021 seconds

Development of Controlled Release Oral Drug Delivery System by Membrane-Coating Method-III- Preparation of Theophylline Tablets and Pharmacokinetic Evaluation in Man- (피막법에 의한 경구투여용 제어방출제제의 개발-III-테오필린함유 제어방출제제의 제조 및 사람의 타액중 농도로부터의 평가-)

  • Shim, Chang-Koo;Kim, Chong-Kook;Lee, Min-Hwa;Kim, Shin-Keun
    • Journal of Pharmaceutical Investigation
    • /
    • v.22 no.3
    • /
    • pp.205-210
    • /
    • 1992
  • In order to develop a controlled-release oral drug delivery system (DDS) of theophylline (TP), microporous membrane-coated tablets were prepared and evaluated in vitro and in vivo. Rapidly water-soluble core tablets of TP (300 mg) were prepared by wet granulation and compression technique, Then the core tablets were spray-coated with polyvinylchloride (PVC) in which micronized sucrose particles were dispersed. Effect of formula compositions of coating suspensions on the pharmaceutical characteristics such as membrane strength and dissolution was investigated in vitro. The membranes remained unbroken in pH 1.2 buffer at $37^{\circ}C$ at least for 2 hours after the disintergration test. TP was released from the coated-released tablets at a zero-order rate over 8 hours. The release at pH 1.2 and 4.0 was similar in rate but a little more rapid than that at pH 6.8. The coated tablets were administered to three healthy male volunteers and their saliva profiles of TP were compared with those from the commercial sustained release TP tablets such as Slobid and Asconthin. Saliva TP concentrations from the coated tablets were successfully sustained over 48 hours after the dosing and were comparable to those of the commercial sustained-release tablets. The membrane-coating technique is very simple and does not need any sophisticated equipments. In this respect, the membrane-coated tablets may be superior to the commercial sustained-release tablets and this technique is worth adopting by the pharmaceutical industries.

  • PDF

Hydrogen Storage Capacities of MOF-5 and Microporous Carbon: Effects of Pt Loading and Hybridization (MOF-5 및 마이크로다공성 카본의 수소 저장 성능: Pt 첨가 및 하이브리드화의 영향)

  • Yunatri, Rika Tri;Suh, Dong-Jin;Suh, Young-Woong
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.19 no.5
    • /
    • pp.377-385
    • /
    • 2008
  • In this study, we demonstrated that, although hydrogen molecules can be adsorbed onto the adsorbent such as MOF and MC itself, the loading of noble metal such as Pt is necessary to enhance the $H_2$ storage capacity since $H_2$ molecules can be dissociatively adsorbed on Pt metal and migrated to high-surface-area adsorbent via the primary spillover. In addition, the hybrid material have been prepared coupling MOF-5 with Pt/MC through carbon bridges formed by sucrose polymerization/carbonization. That this material showed the highest $H_2$ uptake at room temperature and about 100 bar is believed to be associated with the secondary spillover effect. Thus, such a strategy is very promising in developing $H_2$ storage technology using porous adsorbents. However, further experiments should be carried out to explore the choice of bridge carbon, the hybridization method, the dispersion technique of noble metals, etc.

CO2 Capture & Separation in Microporous Materials: A Comparison Between Porous Carbon and Flexible MOFs (다공성 물질을 이용한 CO2 포집 및 분리: 다공성 탄소와 유연한 MOF 비교 연구)

  • Jung, Minji;Park, Seoha;Oh, Hyunchul;Park, Kwi-il
    • Korean Journal of Materials Research
    • /
    • v.28 no.7
    • /
    • pp.417-422
    • /
    • 2018
  • The stereotype of flexible MOFs(Amino-MIL-53) and carbonized porous carbon prepared from renewable resources is successfully synthesized for $CO_2$ reduction application. The textural properties of these microporous materials are investigated, and their $CO_2$ storage capacity and separation performance are evaluated. Owing to the combined effects of $CO_2-Amino$ interaction and its flexibility, a $CO_2$ uptake of $2.5mmol\;g^{-1}$ is observed in Amino-MIL-53 at 20 bar 298 K. In contrast, $CH_4$ uptake in Amino-MIL-53 is very low up to 20 bar, implying potential sorbent for $CO_2/CH_4$ separation. Carbonized samples contain a small quantity of metal residues(K, Ca, Mg, S), resulting in naturally doped porous carbon. Due to the trace metal, even higher $CO_2$ uptake of $4.7mmol\;g^{-1}$ is also observed at 20 bar 298 K. Furthermore, the $CH_4$ storage capacity is $2.9mmol\;g^{-1}$ at 298 K and 20 bar. To evaluate the $CO_2$ separation performance, the selectivity based on ideal adsorption solution theory for $CO_2/CH_4$ binary mixtures on the presented porous materials is investigated.

Structure Variation of Polypropylene Hollow Fiber Membrane with Operation Parameters in Stretching Process (연신 공정 조업변수에 따른 폴리프로필렌 중공사막의 구조 변화)

  • Lee Gyu-Ho;Kim Jin-Ho;Song Ki-Gook;Kim Sung-Soo
    • Polymer(Korea)
    • /
    • v.30 no.2
    • /
    • pp.175-181
    • /
    • 2006
  • Hybrid process of thermally-induced phase separation and stretching was developed for the preparation of microporous polypropylene hollow fiber membranes. Precursor for stretching was prepared by using soybean oil as a diluent and benzoic acid as a nucleating agent far the sphenlite control and it was stretched far the micrporous hollow fiber membrane. The effects of stretching ratio and deformation rate for stretching process were investigated. Increase of stretching ratio resulted in the greater pore size with nonuniform size distribution. Higher deformation rate also increaser the pore size with uniform size distribution. Stretching ratio was closely related with the orientation of polymer chain and increased the mechanical strength of the fiber. Increase of deformation rate had little effects on the orientation of crystalline phase, and decreased the orientation of amorphous phase which caused the decrease of tensile strength of the fiber and broke the micro-fibrils connecting spherulites to form a circular pore shape.

Development of Controlled Release Oral Drug Delivery System by Membrane-Coating Method-I - Preparation and pharmaceutical evaluation of controlled release acetaminophen tablets-

  • Shim, Chang-Koo;Kim, Ki-Man;Kim, Young-Il;Kim, Chong-Kook
    • Archives of Pharmacal Research
    • /
    • v.13 no.2
    • /
    • pp.151-160
    • /
    • 1990
  • In order to develop a controlled-release oral drug delivery system (DDS) which sustains the plasma acetaminophen (AAP) concentration for a certain period of time, microporous membrane-coated tablets were prepared and evaluated in vitro. Firstly, highly water-soluble core tablet of AAP were prepared with various formulations by wet granulation and compression technique. Then the core tablets were coated with polyvinychloride (PVC) in which micronized sucrose particles were dispersed. Effect of formula compositions of core tablets and coating suspensions on the pharmaceutical characteristics such as drug release kinetics and membrane stability of the coated tablets was investigated in vitro. AAP was released from the coated tablets as a zero-order rate in a pH-independent manner. This independency of AAP release to pH change from 1.2 to 7.2 is favorable for the controlled oral drug delivery, since it will produce a constant drug release in the stomach and intestine regardless of the pH change in the GI tract. Drug release could be extended upto 10 h according to the coating condition. The release rate could be controlled by changing the formula compositions of the core tablets and coating suspensions, coat weight per each tablet, and especially PVC/sucrose ratio and particle size of the sucrose in the coating suspension. The coated tablets prepared in this study had a fairly good pharmaceutical characteristics in vitro, however, overall evaluation of the coated tablet should await in vivo absorption study in man.

  • PDF

SURFACE ANALYSES OF TITANIUM SUBSTRATE MODIFIED BY ANODIZATION AND NANOSCALE Ca-P DEPOSITION

  • Lee, Joung-Min;Kim, Chang-Whe;Lim, Young-Jun;Kim, Myung-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.6
    • /
    • pp.795-804
    • /
    • 2007
  • Statement of problem. Nano-scale calcium-phosphate coating on the anodizing titanium surface using ion beam-assisted deposition (IBAD) has been recently introduced to improve the early osseointegration. However, not much is known about their surface characteristics that have influence on tissue-implant interaction. Purpose. This study was aimed to investigate microtopography, surface roughness, surface composition, and wettability of the titanium surface modified by the anodic oxidation and calcium phosphate coating using IBAD. Material and methods. Commercially pure titanium disks were used as substrates. The experiment was composed of four groups. Group MA surfaces represented machined surface. Group AN was anodized surface. Group CaP/AN was anodic oxidized and calcium phosphate coated surfaces. Group SLA surfaces were sandblasted and acid etched surfaces. The prepared titanium discs were examined as follows. The surface morphology of the discs was examined using SEM. The surface roughness was measured by a confocal laser scanning microscope. Phase components were analyzed using thin-film x-ray diffraction. Wettability analyses were performed by contact angle measurement with distilled water, formamide, bromonaphtalene and surface free energy calculation. Results. (1) The four groups showed specific microtopography respectively. Anodized and calcium phosphate coated specimens showed multiple micropores and tiny homogeneously distributed crystalline particles. (2) The order of surface roughness values were, from the lowest to the highest, machined group, anodized group, anodized and calcium phosphate deposited group, and sandblasted and acid etched group. (3) Anodized and calcium phosphate deposited group was found to have titanium and titanium anatase oxides and exhibited calcium phosphorous crystalline structures. (4) Surface wettability was increased in the order of calcium phosphate deposited group, machined group, anodized group, sandblasted and acid etched group. Conclusion. After ion beam-assisted deposition on anodized titanium, the microporous structure remained on the surface and many small calcium phosphorous crystals were formed on the porous surface. Nanoscale calcium phosphorous deposition induced roughness on the microporous surface but hydrophobicity was increased.

Fabrication of Super-hydrophobic Surface using Solubility Difference of Polystyrene at Two Different Solvents (두 용매에서의 폴리스타이렌의 용해도 차이를 이용한 초소수성 표면 제조)

  • Jung, Jin-Suk;Park, Kwang-Bae;Choi, Ho-Suk
    • Clean Technology
    • /
    • v.14 no.1
    • /
    • pp.35-39
    • /
    • 2008
  • In this study, we successfully fabricated a super-hydrophobic polymer layer on the surface of slide glass using the solubility difference of a polymer at two different solvents. After dissolving polystyrene (PS) resins in tetrahydrofuran (THF) as a good solvent and then adding ethanol(EtOH) as a poor solvent, we were able to fabricate super-hydrophobic surface. We also investigated the effect of EtOH addition, coating methods, solution mixing time and speed, and other alcohols on the surface hydrophobicity. The water contact angle (WCA) of the fabricated surface revealed $WCA>150^{\circ}$ and the microporous surface structure composed of microparticles with the size less than $5\;{\mu}m$.

  • PDF

Preparation of Pore-filled Ion-exchange Membranes using Poly(vinylbenzyl ammoninum salt) (Poly(vinylbenzyl ammonium salt)를 이용한 Pore-filled 이온교환막의 제조)

  • 변홍식
    • Membrane Journal
    • /
    • v.11 no.3
    • /
    • pp.109-115
    • /
    • 2001
  • Pore-filled ion-exchange membranes in which polypropylene(PP) microporous membrane was used as a nascent membrane were prepared by an in-situ cross-linking technique. Poly(vinylbenzyl chloride)(PVBCI) reacted with piperazine(PIP) or 1,4-diaminobicyclo[2,2,2]octane(DABCO) in a di-methylforamide(DMF) solution was filled in the pores of the microporous base membrane. After gellation the remaining chloromethyl groups were, then reacted with an amine such as trimethylamine to form positively charged, ammonium site. This will produce the pore-filled anion-exchange membrane. It was shown that this simple 2 step procedure gave dimensionally stable, pore-filled membranes in which the MG of polymer gel and degree of cross-linking could be easily controlled by the concentration of PVBCI and cross-linker in the starting DMF solution. Specially, high water permeability (7.8 kg/$m^2$hr, host membrane: PP3, MG: 73%, degree of cross-linking: 10%, crosslinker: PIP) at ultra low pressure(100 kPa) indicates the produced pore-filled membranes is usable as a water softening membrane.

  • PDF

Thends in Membrane Contactors (분리막 접촉기의 기술 동향)

  • Lee Kew-Ho;Kim Min-Joung;Sea Bongkuk;Park You-In;Lee Ki-Sub
    • Membrane Journal
    • /
    • v.15 no.3
    • /
    • pp.187-197
    • /
    • 2005
  • A membrane contactor is a device that achieves liquid/liquid or gas/liquid mass transfer without dispersion of one phase within another. This is accomplished by passing the fluids on opposite sides of a microporous membrane. This approach offers a number of important advantages over conventional dispersed phase contactors, including absence of emulsions, no flooding at high flow rates, no unloading at low flow rates, and high interfacial area. This article provides a general review of membrane contactors, including operating principles and applications.

Systemic-Pulmonary Shunts Using Microporous Polytetrafluoroethylene Prosthesis [Early and Late Results] (Polytetrafluoroethylene 인조혈관을 이용한 체-폐동맥 단락술의 조기성적 및 원격 성적)

  • 장병철
    • Journal of Chest Surgery
    • /
    • v.19 no.1
    • /
    • pp.50-57
    • /
    • 1986
  • Sixty-nine patients with various types of cyanotic congenital heart disease underwent systemic-pulmonary artery shunts with a microporous polytetrafluoroethylene [PTFE] prosthesis between 1979 and 1985. Their ages ranged from 2 months to 39 years [mean$\pm$SD: 5.2$\pm$7.4, median: 3.3 years]. Diagnosis included the following: Tetralogy of Fallot, 45: Double outlet right or left ventricle, 11: Single ventricle, .5: Transposition of great vessels, 4: Tricuspid atresia, 3 and Pulmonary atresia with intact ventricular septum, 1. Forty-eight patients had subclavian-pulmonary artery anastomosis, 12 patients aorta-right pulmonary artery anastomosis, 6 patients aorta-main pulmonary artery anastomosis, and 3 patients descending aorta-pulmonary artery anastomosis. The PTEE graft of 3 mm in diameter was used in 1, 4 mm in 29, 5 mm in 35 and 6 mm in 4 patients. Ten patients were died within 30 days after operation [mortality rate: 14.5%]. Among them, 6 patients were operated in urgency due to cardiac arrest or severe anoxic spell after cardiac catheterization, and so surgical mortality of elective operation is 9.5%. The 59 survivors showed improvement of the arterial oxygen saturation [65.4% - 9.8%] and hemoglobin [18.8 gm/dl - 16.0 gm/dl] values [V<0.01]. The follow up period ranged from 1 month to 67 months, [752 patient-months] and during this periods there were 4 late shunt failures after 3 months postoperatively with 4 mm graft, and 2 with 5 mm graft. The over-all patency rate of 4 mm PTFE was 85.9$\pm$9.2% [SEM] in 12 months and 40.9$\pm$22.5% in 24 months. The over-all patency rate of 5 mm PTFE was 87.5$\pm$9.6% in 12 months and 58.3$\pm$24.6% in 36 months. The lowest systolic pressure in death group was 64.9$\pm$15.0 mmHg and in survival group, 86.4$\pm$12.1 mmHg [P<0.001]. We think that the PTFE graft is useful in palliative shunt operation, but the effectiveness of the 4 mm PTFE graft may be limited. The blood pressure also may play an important role in patency of Prosthesis.

  • PDF