• Title/Summary/Keyword: Microfluidic Channel

Search Result 138, Processing Time 0.023 seconds

CaCO3 Biomineralization in Microfluidic Crystallizer (미세유체 결정화기를 이용한 탄산칼슘 Biomineralization)

  • Seo, Seung Woo;Ko, Kwan Young;Lee, Chang Soo;Kim, In Ho
    • Korean Chemical Engineering Research
    • /
    • v.51 no.1
    • /
    • pp.151-156
    • /
    • 2013
  • Crystallization of $CaCO_3$ is practiced on a polymethylsiloxane (PDMS) - based microfluidic system. Liquid- liquid reaction was investigated by mixing calcium chloride ($CaCl_2$) and sodium carbonate ($Na_2CO_3$) solution to crystallize $CaCO_3$. Aspartic acid (Asp) was added to investigate the morphology change such as vaterite and calcite. Suitable ratio of $Na_2CO_3$ and $CaCl_2$ was searched for initial seed formation. Christmas tree model was used as microfluidic device to form concentration gradient of $Na_2CO_3$ and $CaCl_2$. After observing microfluidic channel by using optical microscope, we found that seeds of $CaCO_3$ were formed under the condition that the ratio of $Na_2CO_3$ and $CaCl_2$ was 2:1. Morphology of crystals were also observed as $CaCO_3$ crystals grow. When Asp was added, vaterite crystal was more frequently found in two morphologies (vaterite and calcite) and seed formation and crystal growth were inhibited.

A Study on the Ultra-Precision Polishing Technique for the Upper Surface of the Micro-Channel Structure (미세채널 구조물 상부의 초정밀 연마 기술 연구)

  • 강정일;이윤호;안병운;윤종학
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.313-317
    • /
    • 2003
  • Micro-Channel ultra-precision polishing is a new technology used in magnetic field-assisted relishing. In this paper, an electromagnet or the i18 of test system was designed and manufactured. A size of magnetic abrasive is used on 25~75${\mu}{\textrm}{m}$ and for the polish a micro-channel upper part. A surface of channel which is not even is manufactured using magnetic abrasive finishing at upper surface of micro-channel. As a result, the surface roughness rose by 80% after upper surface of micro- channel was polished up 8 minutes by polishing.

  • PDF

Fabrication of channel-integrated optoelectrofluidic device using stamp-to-stick bonding and microtransfer methods (Stamp-to-Stick Bonding 및 Microtransfer Molding 방법을 이용한 미세유체 채널이 집적된 광전기유체소자의 제작)

  • Hwang, Hyun-Goo;Lee, Do-Hyun;Park, Je-Kyun
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.2
    • /
    • pp.154-159
    • /
    • 2009
  • This paper describes two methods - stamp-to-stick bonding and microtransfer molding - to integrate microfluidic channel into an optoelectrofluidic device for in-channel microparticle manipulation. We have demonstrated the optoelectronic microparticle manipulation in the channel-integrated optoelectrofluidic device using a liquid crystal display. As injecting a liquid sample containing $15{\mu}m$-diameter polystyrene particles into the fabricated channel, trapping and transport of individual microparticles have been successfully demonstrated. This channel-integrated optoelectrofluidic device may be useful for several in-channel applications based on the optoelectrofluidics such as optoelectronic flow control, droplet-based protein assay and bead-based immunoassay.

A Disposable BioChip for Single Cell Manipulation

  • Yoon, Euisik
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2004.10a
    • /
    • pp.1-15
    • /
    • 2004
  • o Various microfluidic components including mixromixers and micropumps have been developed for disposable biochip applications. o Single cell capturing, positioning and nanoliter drug injection chip has been demostrated. o Multi-channel, two-dimensional micro-well array has been fabricated and cell capturing and specific reagent injection have been performed.

  • PDF

Single Magnetic Bead Detection in a Microfluidic Chip Using Planar Hall Effect Sensor

  • Kim, Hyuntai;Reddy, Venu;Kim, Kun Woo;Jeong, Ilgyo;Hu, Xing Hao;Kim, CheolGi
    • Journal of Magnetics
    • /
    • v.19 no.1
    • /
    • pp.10-14
    • /
    • 2014
  • In this study, we fabricate an integrated microfluidic chip with a planar Hall effect (PHE) sensor for single magnetic bead detection. The PHE sensor was constructed with a junction size of $10{\mu}m{\times}10{\mu}m$ using a trilayer structure of Ta(3 nm)/NiFe(10 nm)/Cu(1.2 nm)/IrMn(10 nm)/Ta(3 nm). The sensitivity of the PHE sensor was 19.86 ${\mu}V/Oe$. A diameter of 8.18 ${\mu}m$ magnetic beads was used, of which the saturation magnetization was ~2.1 emu/g. The magnetic susceptibility ${\chi}$ of these magnetic beads was calculated to be ~0.14. The diluted magnetic beads solution was introduced to the microfluidic channel attributing a single bead flow and simultaneously the PHE sensor voltage was measured to be 0.35 ${\mu}V$. The integrated microchip was able to detect a magnetic moment of $1.98{\times}10^{-10}$ emu.

Spin-coated ultrathin multilayers and their micropatterning using microfluidic channels

  • Hongseok Jang;Kim, Sangcheol;Jinhan Cho;Kookheon Char
    • Korea-Australia Rheology Journal
    • /
    • v.15 no.1
    • /
    • pp.1-7
    • /
    • 2003
  • A new method is introduced to build up organic/organic multilayer films composed of cationic poly(allylamine hydrochloride) (PAH) and negatively charged poly (sodium 4-styrenesulfonate) (PSS) using the spinning process. The adsorption process is governed by both the viscous force induced by fast solvent elimination and the electrostatic interaction between oppositely charged species. On the other hand, the centrifugal and air shear forces applied by the spinning process significantly enhances desorption of weakly bound polyelectrolyte chains and also induce the planarization of the adsorbed polyelectrolyte layer. The film thickness per bilayer adsorbed by the conventional dipping process and the spinning process was found to be about 4 ${\AA}$ and 24 ${\AA}$, respectively. The surface of the multilayer films prepared with the spinning process is quite homogeneous and smooth. Also, a new approach to create multilayer ultrathin films with well-defined micropatterns in a short process time is Introduced. To achieve such micropatterns with high line resolution in organic multilayer films, microfluidic channels were combined with the convective self-assembly process employing both hydrogen bonding and electrostatic intermolecular interactions. The channels were initially filled with polymer solution by capillary pressure and the residual solution was then removed by the .spinning process.

Phase-Separation Properties of Poly(Ethylene Glycol) had Dextran Solutions In Microfluidic Device (미세 유체장치 내에서 Poly(Ethylene Glycol)과 Dextran 용액의 상 형성 특성 연구)

  • Choi, Joo-Hyung;Chang, Woo-Jin;Lee, Sang-Woo
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.2
    • /
    • pp.244-249
    • /
    • 2007
  • Fluidic conditions for the separation of phases were surveyed in a microfluidic aqueous two-phase extraction system. The infusion ratio between polyethylene glycol (PEG) and dextran solution defines the concentrations of each polymer in micro-channel, which determine the phase-separation. The appropriate ratio between PEG (M.W. 8000, 10%, w/v) and dextran T500 (M.W. 500000, 5%, w/v) in order to perform the separation of phases of both polymers was observed as changing the mixed ratio of both polymers. Based on the fluidic conditions, stable two-phase solutions were obtained within 4% to 8% and 3% to 1% of PEG and dextran, respectively. In addition, the characteristics of the two-phase were discussed. The separation technique studied in the paper can be applied for the implementation of a lab-on-a chip which can detect various biological entities such cells, bacterium, and virus in an integrated manner using built in a biosensor inside the chip.

Optical Manipulation of Droplets in a Microfluidic Platform (미세 유체 플랫폼에서의 광력을 이용한 액적의 연속적인 제어 기술의 개발)

  • Jung, Jin Ho;Cho, Hyunjun;Ha, Byung Hang;Destgeer, Ghulam;Sung, Hyung Jin
    • Journal of the Korean Society of Visualization
    • /
    • v.12 no.2
    • /
    • pp.13-17
    • /
    • 2014
  • In the present study, the optofluidic droplet manipulation in a microfluidic platform was demonstrated via theoretical and experimental approaches. Optical scattering force and gradient force were used to separate and trap droplets. Two types of droplets were generated by a T-junction method in the microfluidic channel. While they approach a test region where the optical beam illuminates the droplets, they were pushed by the optical scattering beam. The displacement by the laser beam is dependent on the refractive index of the droplets. By using the optical gradient force, the droplets can be trapped and coalesced. In order to bring the droplets in a direct contact, the optical gradient force was used to trap the droplets. A theoretical modeling of the coalescence was derived by combining the optical force and drag force on the droplet.

Fabrication and Simulation of Fluid Wing Structure for Microfluidic Blood Plasma Separation

  • Choe, Jeongun;Park, Jiyun;Lee, Jihye;Yeo, Jong-Souk
    • Applied Science and Convergence Technology
    • /
    • v.24 no.5
    • /
    • pp.196-202
    • /
    • 2015
  • Human blood consists of 55% of plasma and 45% of blood cells such as white blood cell (WBC) and red blood cell (RBC). In plasma, there are many kinds of promising biomarkers, which can be used for the diagnosis of various diseases and biological analysis. For diagnostic tools such as a lab-on-a-chip (LOC), blood plasma separation is a fundamental step for accomplishing a high performance in the detection of a disease. Highly efficient separators can increase the sensitivity and selectivity of biosensors and reduce diagnostic time. In order to achieve a higher yield in blood plasma separation, we propose a novel fluid wing structure that is optimized by COMSOL simulations by varying the fluidic channel width and the angle of the bifurcation. The fluid wing structure is inspired by the inertial particle separator system in helicopters where sand particles are prevented from following the air flow to an engine. The structure is ameliorated in order to satisfy biological and fluidic requirements at the micro scale to achieve high plasma yield and separation efficiency. In this study, we fabricated the fluid wing structure for the efficient microfluidic blood plasma separation. The high plasma yield of 67% is achieved with a channel width of $20{\mu}m$ in the fabricated fluidic chip and the result was not affected by the angle of the bifurcation.

Magnetic Force-based Immunochip using Superparamagnetic Nanoparticles

  • Park, Je-Kyun;Kim, Kyu-Sung
    • 한국생물공학회:학술대회논문집
    • /
    • 2005.04a
    • /
    • pp.19-19
    • /
    • 2005
  • This paper reports a novel magnetic force-based microfluidic immunoassay using microbeads and magnetic nanoparticles. The magnetic force-based immunoassay was devised first and successfully applied to detect the rabbit IgG as the model analyte of microfluidic sandwich immunoassay. The microchannels were fabricated by poly(dimethysiloxane) (PDMS) molding processes and bonded on a slide glass by plasma treatment. At the part of the inlet, sample solution was hydrodynamically focused. The focused microbeads of sample solution were flowed through the 150 ${\mu}m$ width channel of outlet. However, when the microbeads are conjugated with the superparamagnetic nanoparticles under the applied magnetic fields, they will switch their flow path and flow through the 95 ${\mu}m$ width channel of outlet. The movements of microbeads conjugated with magnetic nanoparticles were demonstrated by magnetic field $gradients.^{1)}$ High magnetic field gradients using micro electromagnets could be applied to this detection method for high sensitivity and lower detection limit. In addition, the multiplexed $immunoassay^{2)}$ using an encoded microbead which is immobilized with a certain antibody could be possible using this detection principle.

  • PDF