• Title/Summary/Keyword: Microcatheter

Search Result 31, Processing Time 0.023 seconds

Endovascular Rescue Method for Undesirably Stretched Coil

  • Cho, Jae Hoon
    • Journal of Korean Neurosurgical Society
    • /
    • v.56 no.4
    • /
    • pp.364-367
    • /
    • 2014
  • Undesirable detachment or stretching of coils within the parent artery during aneurysm embolization can be related with thrombus formation, which can be caused occlusion of parent artery or embolic event(s). To escape from this situation, several rescue methods have been reported. A case with undesirably stretched coil in which another rescue method was used, is presented. When the stretched coil is still located in the coil delivery microcatheter, the stretched coil can be removed safely using a snare and a handmade monorail microcatheter. After a snare is lodged in the handmade monorail microcatheter, the snare is introduced over the coil delivery micorcatheter and located in the distal part of the stretched coil. After then, the handmade monorail microcatheter captures the stretched coil and the snare as one unit. This technique using a handmade monorail microcatheter and a snare can be a good rescue modality for the undesirably stretched coil, still remained within the coil delivery microcatheter.

Comparison of Long-Term Angiographic Results of Wide-Necked Intracranial Aneurysms : Endovascular Treatment with Single-Microcatheter Coiling, Double-Microcatheter Coiling, and Stent-Assisted Coiling

  • Kim, Hyun Sik;Cho, Byung Moon;Yoo, Chan Jong;Choi, Dae Han;Hyun, Dong Keun;Shim, Yu Shik;Song, Joon Ho;Oh, Jae Keun;Ahn, Jun Hyong;Kim, Ji Hee;Chang, In Bok
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.5
    • /
    • pp.751-762
    • /
    • 2021
  • Objective : Endovascular treatment of intracranial aneurysms is challenging in case of wide-necked aneurysms because coils are prone to herniate into the parent artery, causing thromboembolic events or vessel occlusion. This study aims to compare long-term angiographic results of wide-necked aneurysms treated by stent-assisted, double-microcatheter, or single-microcatheter groups. Methods : Between January 2003 and October 2016, 108 aneurysms that were treated with endovascular coil embolization with a neck size wider than 4 mm and a follow-up period of more than 3 years were selected. We performed coil embolization with single-microcatheter, double-microcatheter, and stent-assisted techniques. Angiographic results were evaluated using the Raymond-Roy occlusion classification (RROC). All medical and angiographic records were reviewed retrospectively. Results : Clinical and angiographic analyses were conducted in 108 wide-necked aneurysms. The immediate post-procedural results revealed RROC class I (complete occlusion) in 66 cases (61.1%), class II (residual neck) in 36 cases (33.3%), and class III (residual sac) in six cases (5.6%). The final follow-up results revealed class I in 48 cases (44.4%), class II in 49 cases (45.4%), and class III in 11 cases (10.2%). Of a total of 45 (41.6%) radiologic recurrences, there were 21 cases (19.4%) of major recurrence that required additional treatment, and 24 cases (22.2%) of minor recurrence. The final follow-up angiographic results showed statistically significant differences between the stent-assisted group and the others (p<0.01). Conclusion : Long-term follow-up angiography demonstrated that the stent-assisted technique had a better complete occlusion rate than the other two techniques.

Microguidewire Looping to Traverse Stented Parent Arteries of Intracranial Aneurysms

  • Cho, Young Dae;Rhim, Jong Kook;Yoo, Dong Hyun;Kang, Hyun-Seung;Kim, Jeong Eun;Han, Moon Hee
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.2
    • /
    • pp.262-268
    • /
    • 2017
  • Objective : Stents are widely used in coil embolization of intracranial aneurysms, but on occasion, a microcatheter must traverse a stented segment of artery (so-called trans-cell technique) to select an aneurysm, or double stenting may necessary. In such situations, microguidewire passage and microcatheter delivery through a tortuous stented parent artery may pose a technical challenge. Described herein is a microguidewire looping technique to facilitate endovascular navigation in these circumstances. Methods : To apply this technique, the microguidewire tip is looped before entering the stented parent artery and then advanced distally past the stented segment, with the loop intact. Rounding of the tip prevents interference from stent struts during passage. A microcatheter is subsequently passed into the stented artery for positioning near the neck of aneurysm, with microguidewire assistance. The aneurysm is then selected, steering the microcatheter tip (via inner microguidewire) into the dome. Results : This technique proved successful during coil embolization of nine saccular intracranial aneurysms (internal carotid artery [ICA], 6; middle cerebral artery, 2; basilar tip, 1), performing eight trans-cell deliveries and one additional stenting. Selective endovascular embolization was enabled in all patients, resulting in excellent clinical and radiologic outcomes, with no morbidity or mortality directly attributable to microguidewire looping. Conclusion : Microguidewire looping is a reasonable alternative if passage through a stented artery is not feasible by traditional means, especially at paraclinoid ICA sites.

Endovascular Approach in Patients with Acute Complete Occlusion Due to Middle Cerebral Artery Dissection

  • Park, Kang-Hoon;Kwak, Hyo Sung;Park, Jung-Soo
    • Journal of Korean Neurosurgical Society
    • /
    • v.63 no.6
    • /
    • pp.717-722
    • /
    • 2020
  • Objective : Dissection of the middle cerebral artery (MCA) is less common than dissection of vessels in the vertebrobasilar system or carotid artery. Acute complete occlusion related to MCA dissection is extremely rare. We report an endovascular approach in patients with acute complete occlusion due to MCA dissection. Methods : We reviewed retrospectively the endovascular procedure and clinical results for acute-stroke patients who underwent recanalization from October 2014 through December 2018. Initial imaging findings and the endovascular procedure were analyzed for patients with acute complete occlusion due to MCA dissection. Results : We undertook first-line aspiration thrombectomy using a Penumbra catheter in 294 patients with acute occlusion of the M1 segment. Of these patients, seven were confirmed to have acute complete occlusion due to MCA dissection. All patients had angiographic findings of an intimal flap at the proximal occlusion site of the MCA. One patient complained of severe headache during microcatheter passage through the occluded lesion and died due to massive bleeding caused by rupture of the false lumen. The remaining patients underwent initial contact aspiration thrombectomy without microcatheter passage. After aspiration thrombectomy, six patients had delayed flow through the MCA. One patient underwent stenting of the MCA because of progressive symptoms. Conclusion : An intimal flap at the proximal portion of an occluded MCA can suggest the possibility of MCA dissection. Contrast aspiration thrombectomy without microcatheter passage can reduce the risk of false lumen rupture in cases of MCA dissection.

Folded-Loop Guidewire Remodeling Technique: Catheterizing Markedly Angulated Branches during Intravascular Embolization (Folded-Loop Guidewire Remodeling Technique: 색전술 시 급격한 분지 각도를 가지는 혈관의 선택적 진입 방법)

  • Dong Hyun Kim;Ung Rae Kang;Young Hwan Kim;Jung Guen Cha
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.2
    • /
    • pp.418-426
    • /
    • 2023
  • Purpose Practical challenges are encountered in percutaneous intravascular procedures when applied to markedly angulated branching vessels. Herein, we introduced a folded-loop guidewire remodeling technique-the guidewire-shaping technique-to overcome difficult catheterization. Materials and Methods First, the tip of a 0.014-inch micro-guidewire was manually shaped like a pigtail loop. Second, the shaped guidewire was introduced into the microcatheter and was preloaded into the hollow metal introducer for suitability with the microcatheter hub. Gentle rotation of the guidewire after release from the microcatheter can create the preshaped pigtail loop configuration. On pulling back, the loop loosened, the configuration was changed to a small U-shaped tip, and the guidewire tip was easily introduced into the target artery. Results Between December 2019 and January 2022, the described technique was used in 64 patients (male/female, 49/15; mean age, 66.8 ± 9.5 years) for selective arterial embolization, after failed attempts with the conventional selection technique. The technique was successful in 63/64 patients (98%). The indications of embolization include transcatheter arterial chemoembolization, gastrointestinal bleeding, hemoptysis, trauma-induced bleeding, and tumor bleeding. Conclusion The folded-loop guidewire remodeling technique facilitates the catheterization of markedly angulated branching arteries; when usual catheterization method fails.

Transcranial Direct Middle Meningeal Artery Puncture for the Onyx Embolization of Dural Arteriovenous Fistula Involving the Superior Sagittal Sinus

  • Oh, Jae-Sang;Yoon, Seok-Mann;Shim, Jai-Joon;Bae, Hack-Gun
    • Journal of Korean Neurosurgical Society
    • /
    • v.57 no.1
    • /
    • pp.54-57
    • /
    • 2015
  • A 66-year-old woman presented with intermittent paraparesis and generalized tonic-clonic seizure. Cerebral angiography demonstrated dural arteriovenous fistula (AVF) involving superior sagittal sinus (SSS), which was associated with SSS occlusion on the posterior one third. The dural AVF was fed by bilateral middle meningeal arteries (MMAs), superficial temporal arteries (STAs) and occipital arteries with marked retrograde cortical venous reflux. Transfemoral arterial Onyx embolization was performed through right MMA and STA, but it was not successful, which resulted in partial obliteration of dural AVF because of tortuous MMA preventing the microcatheter from reaching the fistula closely enough. Second procedure was performed through left MMA accessed by direct MMA puncture following small decortications of cranium overlying the MMA using diamond drill one week later. Microcatheter could be located far distally to the fistula through 5 F sheath placed into the MMA and complete obliteration of dural AVF was achieved using 3.9 cc of Onyx.

Technical Consideration for Coiling of Ruptured Proximal Posterior Inferior Cerebellar Artery Aneurysm

  • Kim, Jong Hoon;Jeon, Ik Chan;Chang, Chul Hoon;Jung, Young Jin
    • Journal of Korean Neurosurgical Society
    • /
    • v.61 no.5
    • /
    • pp.653-659
    • /
    • 2018
  • Objective : Surgical obliteration of ruptured aneurysm of the proximal posterior inferior cerebellar artery (PICA) is challenging because of limited surgical accessibility. In recent years, coil embolization is the first-choice treatment for these lesions. However, coil embolization is not always easy in ruptured PICA aneurysm owing to the variable anatomical diversity of its shapes, its relationship to the parent artery, its low incidence, and accordingly, lesser neurointerventionist experience. Methods : The parent artery and microcatheter for easier navigation and the embolization technique for stable coiling were identified. Results : This study aimed to identify the more appropriate approach route, microcatheter, and strategies for an easier and safer, and more durable coil embolization in the treatment of lesions in the proximal PICA. Conclusion : Coil embolization for aneurysmal subarachnoid hemorrhage due to a ruptured proximal PICA remains a challenge, but with the appropriate coiling plan, it can be treated successfully.

A Study on Die Design Optimization for Microcatheter Extrusion Processes (마이크로 카테터 압출 공정을 위한 다이 설계 최적화에 관한 연구)

  • Jo, Seunggi;Lee, Euntaek
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.1
    • /
    • pp.34-41
    • /
    • 2021
  • Interventional radiology and minimally invasive surgery both require a precisely shaped microcatheter. Microcatheters are manufactured using polymer extrusion processes with a die and puller. The manufacturing parameters and die geometry greatly influence the profile of the extrudate and designing dies using a trial-and-error process is expensive and requires a lot of time. Therefore, predicting the profile of the extrudate is important for manufacturing microcatheters. This study investigates the effects of die design and geometry on the profile of the extrudate. The profiles of the extrudate are predicted using ANSYS Polyflow with respect to the different die geometries. The outer and inner diameters and wall thickness of the predicted extrudate are compared to those of a target extrudate. The die swell of melt polymer and the effect of the pulling are both examined. Optimized die designs are suggested for manufacturing the target extrudate.

Blood-Brain Barrier Experiments with Clinical Magnetic Resonance Imaging and an Immunohistochemical Study

  • Park, Jun-Woo;Kim, Hak-Jin;Song, Geun-Sung;Han, Hyung-Soo
    • Journal of Korean Neurosurgical Society
    • /
    • v.47 no.3
    • /
    • pp.203-209
    • /
    • 2010
  • Objective : The purpose of study was to evaluate the feasibility of brain magnetic resonance (MR) images of the rat obtained using a 1.5T MR machine in several blood-brain barrier (BBB) experiments. Methods : Male Sprague-Dawley rats were used. MR images were obtained using a clinical 1.5T MR machine. A microcatheter was introduced via the femoral artery to the carotid artery. Normal saline (group 1, n = 4), clotted autologous blood (group 2, n = 4), triolein emulsion (group 3, n = 4), and oleic acid emulsion (group 4, n = 4) were infused into the carotid artery through a microcatheter. Conventional and diffusion-weighted images, the apparent coefficient map, perfusion-weighted images, and contrast-enhanced MR images were obtained. Brain tissue was obtained and triphenyltetrazolium chloride (TTC) staining was performed in group 2. Fluorescein isothiocyanate (FITC)-labeled dextran images and endothelial barrier antigen (EBA) studies were performed in group 4. Results : The MR images in group 1 were of good quality. The MR images in group 2 revealed typical findings of acute cerebral infarction. Perfusion defects were noted on the perfusion-weighted images. The MR images in group 3 showed vasogenic edema and contrast enhancement, representing vascular damage. The rats in group 4 had vasogenic edema on the MR images and leakage of dextran on the FITC-labeled dextran image, representing increased vascular permeability. The immune reaction was decreased on the EBA study. Conclusion : Clinical 1.5T MR images using a rat depicted many informative results in the present study. These results can be used in further researches of the BBB using combined clinical MR machines and immunohistochemical examinations.