• Title/Summary/Keyword: MicroCT

Search Result 423, Processing Time 0.026 seconds

Effect of Porcine Cancellous Bones on Regeneration in Rats with Calvarial Defect (랫드의 두개골 결손부에서 돼지 해면질골이 골재생에 미치는 영향)

  • Yoo, Kyeong-Hoon;Kim, Se-Eun;Shim, Kyung-Mi;Park, Hyun-Jeong;Choi, Seok-Hwa;Kang, Seong-Soo
    • Journal of Life Science
    • /
    • v.20 no.8
    • /
    • pp.1207-1213
    • /
    • 2010
  • The purpose of this study was to evaluate the effect of porcine cancellous bone as a scaffold in a rat calvarial defect model. Critical-sized defects were created in 30 male Sprague-Dawley rats. The animals were divided into critical defect (CD, n=10), $\beta$-tricalcium phosphate (TCP) graft (BT, n=10) and porcine cancellous bone graft (PCB, n=10) groups. Each defect was filled with $\beta$-TCP mixed with fibrin glue or porcine cancellous bone powder mixed with fibrin glue. In the CD group, the defect was left empty. All rats were sacrificed at 8 weeks after bone graft surgery, and bone formation was evaluated by gross observation, plain radiography, micro-computed tomography scanning and histological evaluation. Repair of bone defect was the least in the CD group, and significant new bone formation was observed in the PCB group. Grafting of porcine cancellous bone was more efficient for regenerating new bone than grafting $\beta$-TCP.

The Effect of Post-Treatment N-Acetylcysteine in LPS-Induced Acute Lung Injury of Rats

  • Choi, Jae Sung;Lee, Ho Sung;Seo, Ki Hyun;Na, Ju Ock;Kim, Yong Hoon;Uh, Soo Taek;Park, Choon Sik;Oh, Mee Hye;Lee, Sang Han;Kim, Young Tong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.73 no.1
    • /
    • pp.22-31
    • /
    • 2012
  • Background: Oxidation plays an important role in acute lung injury. This study was conducted in order to elucidate the effect of repetitive post-treatment of N-acetylcysteine (NAC) in lipopolysaccaride (LPS)-induced acute lung injury (ALI) of rats. Methods: Six-week-old male Sprague-Dawley rats were divided into 4 groups. LPS (Escherichia coli 5 mg/kg) was administered intravenously via the tail vein. NAC (20 mg/kg) was injected intraperitoneally 3, 6, and 12 hours after LPS injection. Broncho-alveolar lavage fluid (BALF) and lung tissues were obtained to evaluate the ALI at 24 hours after LPS injection. The concentration of tumor necrosis factor ${\alpha}$ (TNF-${\alpha}$) and interleukin $1{\beta}$ (IL-$1{\beta}$) were measured in BALF. Nuclear factor ${\kappa}B$ (NF-${\kappa}B$), lipid peroxidation (LPO), and myeloperoxidase (MPO) were measured using lung tissues. Micro-computed tomography (micro-CT) images were examined in each group at 72 hours apart from the main experiments in order to observe the delayed effects of NAC. Results: TNF-${\alpha}$ and IL-$1{\beta}$ concentration in BALF were not different between LPS and NAC treatment groups. The concentration of LPO in NAC treatment group was significantly lower than that of LPS group ($5.5{\pm}2.8$ nmol/mL vs. $16.5{\pm}1.6$ nmol/mL) (p=0.001). The activity of MPO in NAC treatment group was significantly lower than that of LPS group ($6.4{\pm}1.8$ unit/g vs. $11.2{\pm}6.3$ unit/g, tissue) (p<0.048). The concentration of NF-${\kappa}B$ in NAC treatment group was significantly lower than that of LPS group ($0.3{\pm}0.1\;ng/{\mu}L$ vs. $0.4{\pm}0.2\;ng/{\mu}L$) (p=0.0001). Micro-CT showed less extent of lung injury in NAC treatment than LPS group. Conclusion: After induction of ALI with lipopolysaccharide, the therapeutic administration of NAC partially attenuated the extent of ALI through the inhibition of NF-${\kappa}B$ activation.

Reliability Assessment and Prediction of Solder Joints in High Temperature Heaters (고온히터 솔더접합부의 신뢰성 평가 및 예측)

  • Park, Eunju;Kwon, Daeil;Sa, Yoonki
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.24 no.2
    • /
    • pp.23-27
    • /
    • 2017
  • This paper proposes an approach to predict the reliability of high temperature heaters by identifying their primary failure modes and mechanisms in the field. Test specimens were designed to have the equivalent stress conditions with the high temperature heaters in the field in order to examine the effect of stress conditions on the solder joint failures. There failures often result from cracking due to intermetallic compound (IMC) or void formation within a solder joint. Aging tests have been performed by exposing the test specimens to a temperature of $170^{\circ}C$ in order to reproduce solder joint failures in the field. During the test, changes in IMC formation were investigated by scanning electron microscopy (SEM) on the cross-sections of the test specimens, while changes in void formation were monitored both by resistance spectroscopy and by micro-computed tomography (microCT), alternately. The test results demonstrated the void volume within the solder increased as the time at the high temperature increased. Also, the phase shift of high frequency resistance was found to have high correlation with the void volume. These results implied the failure of high temperature heaters can be non-destructively predicted based on the correlation.

The effects of zoledronic acid on the progression of experimental periodontitis in rats: histological and microtomographic analyses

  • de Marcelos, Priscylla Goncalves Correia Leite;da Cruz Perez, Danyel Elias;Soares, Diego Moura;de Araujo, Samuel Silva;Evencio, Liriane Baratella;Pontual, Maria Luiza dos Anjos;Ramos-Perez, Flavia Maria de Moraes
    • Journal of Periodontal and Implant Science
    • /
    • v.51 no.4
    • /
    • pp.264-275
    • /
    • 2021
  • Purpose: Periodontitis is considered a local risk factor for medication-related osteonecrosis of the jaws (MRONJ). However, little is known about the progression of periodontitis in the presence of zoledronic acid (ZOL). The aim of this study was to evaluate the effects of the systemic use of ZOL on the progression of experimental periodontitis (EP) in rats, as ZOL could modulate the progression of periodontitis and concomitantly cause MRONJ in individuals with periodontitis. Methods: Forty-eight male Wistar rats were randomly distributed in 6 groups (n=8 each). To induce EP, ligatures were placed around the right first mandibular molars. Three groups were treated with ZOL (0.15 mg/kg/week, intraperitoneal), and 3 with 0.9% saline solution (controls). In the ZOL/Lig30 and ZOL/Lig 15 groups, after 4 weeks of treatment with ZOL, EP was induced and euthanasia was performed after 30 and 15 days of EP induction, respectively. In both groups, the animals continued to receive ZOL after EP until the end of the experiment. In the Lig/ZOL group, EP was induced first, and 15 days later, ZOL was administered for 8 weeks, with euthanasia 1 week after the last dose. After euthanasia, the mandibles were evaluated using micro-computed microtomography (micro-CT) and histomorphometry. Bone loss was measured, and the presence of osteonecrosis was evaluated histologically. The data were evaluated using the Student t-test and the Mann-Whitney test, with a significance level of 5%. Results: In the Lig/ZOL group, micro-CT revealed less alveolar bone resorption in the distal root (P<0.01) than in the control group (Lig/Con). Histomorphometric analysis confirmed less alveolar bone resorption in the Lig/ZOL group (P=0.001). Histologically, osteonecrosis was more common in the ZOL groups. Conclusion: ZOL decreased alveolar bone resorption in rats with EP. However, it presented a higher risk for MRONJ.

Layered structure of sialoliths compared with tonsilloliths and antroliths

  • Buyanbileg Sodnom-Ish;Mi Young Eo;Yun Ju Cho;Mi Hyun Seo;Hyeong-Cheol Yang;Min-Keun Kim;Hoon Myoung;Soung Min Kim
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.50 no.1
    • /
    • pp.13-26
    • /
    • 2024
  • Objectives: The aim of this study was to perform a comparative analysis of the ultrastructural and chemical composition of sialoliths, tonsilloliths, and antroliths and to describe their growth pattern. Materials and Methods: We obtained 19 specimens from 18 patients and classified the specimens into three groups: sialolith (A), tonsillolith (B), and antrolith (C). The peripheral, middle, and core regions of the specimens were examined in detail by histology, micro-computed tomography (micro-CT), scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy, and transmission electron microscopy (TEM). Results: In the micro-CT, group A showed alternating radiodense and radiolucent layers, while group B had a homogeneous structure. Group C specimens revealed a compact homogeneous structure. Histopathologically, group A showed a laminated, teardrop-shaped, globular structure. Group B demonstrated degrees of immature calcification of organic and inorganic materials. In group C, the lesion was not encapsulated and showed a homogeneous lamellar bone structure. SEM revealed that group A showed distinct three layers: a peripheral multilayer zone, intermediate compact zone, and the central nidus area; groups B and C did not show these layers. The main elemental components of sialoliths were O, C, Ca, N, Cu, P, Zn, Si, Zr, F, Na, and Mg. In group B, a small amount of Fe was found in the peripheral region. Group C had a shorter component list: Ca, C, O, P, F, N, Si, Na, and Mg. TEM analysis of group A showed globular structures undergoing intra-vesicular calcification. In group B, bacteria were present in the middle layer. In the outer layer of the group C antrolith, an osteoblastic rimming was observed. Conclusion: Sialoliths had distinct three layers: a peripheral multilayer zone, an intermediate compact zone and the central nidus area, while the tonsillolith and antrolith specimens lacked distinct layers and a core.

Numerical Analysis on the compressive behavior of closed-cell Al foam (닫힌 셀 구조 Al 발포 재료의 압축 거동에 대한 수치해석)

  • Jeon, In-Su
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1663-1666
    • /
    • 2007
  • The finite element method is applied to analyze the deformation mechanisms in the closed-cell Al foam under the compression. The modeling of the real cellular structure proceeds with the concept of the reverse engineering. First of all, the small, $10{\times}\;10{\times}\;10mm^3$ sized specimens of the closed-cell Al foam are prepared. The micro focus X-ray CTsystem of SHIMADZU Corp. is used to scan the full structures of the specimens. The scanned structures are converted to the geometric surfaces and solids through the software for 3-D scan data processing, RapidFormTMof INUS Tech. Inc. Then the solid meshes are directly generated on the converted geometric solids for the finite element analysis. The large elastic-plastic deformation and 3-D contact problems for the Al cellular material are considered. The clear and successful analysis for the deformation mechanisms in the closed-cell Al foam is carried out through the comparison of the numerical results in this research with the referred experimental ones.

  • PDF

Fabrication and Characterization of Electrospun PLGA/Gelatin Nanofiber Tube for Potential Intestinal Stent Application

  • Son, So-Ra;Franco, Rose-Ann;Bao, Trinh-Quang;Bae, Sang-Ho;Min, Young-Ki;Lee, Byong-Taek
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.05a
    • /
    • pp.51.1-51.1
    • /
    • 2011
  • An electrospun Poly (lactice-co-glycolide acid) (PLGA) and Gelatin nanofiber tube was fabricated for potential intestinal stent application. Mechanical properties of tube were evaluated by tensile strength and burst strength tests. Physical and chemical properties were evaluated by contact angle measurement, swelling rates and porosity measurements. Biodegradability was investigated by immersion in simulated body fluid (SBF). Biocompatibility was investigated in vitro by cytotoxicity and proliferation studies by MTT assay, confocal microscopy and western blot using IEC-18 (Rat intestinal epithelial cell). After intestinal stent was implanted into rat bowel for periods from 7 to 10days, it was then analyzed using micro-computed tomography (Micro CT) and X-ray techniques. Futhermore, histological analysis was performed by hematoxylin-eosin (H&E) stain.

  • PDF

Evaluation of apical canal shapes produced sequentially during instrumentation with stainless steel hand and Ni-Ti rotary instruments using Micro-computed tomography (Stainless steel hand file과 Ni-Ti rotary file을 이용한 근관 형성시 근단부 근관 형태의 순차적 변화에 대한 평가)

  • Lee, Woo-Jin;Lee, Jeong-Ho;Chun, Kyung-A;Seo, Min-Seock;Yoo, Yeon-Jee;Baek, Seung-Ho
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.3
    • /
    • pp.231-237
    • /
    • 2011
  • Objectives: The purpose of this study was to determine the optimal master apical file size with minimal transportation and optimal efficiency in removing infected dentin. We evaluated the transportation of the canal center and the change in untouched areas after sequential preparation with a #25 to #40 file using 3 different instruments: stainless steel K-type (SS K-file) hand file, ProFile and LightSpeed using microcomputed tomography (MCT). Materials and Methods: Thirty extracted human mandibular molars with separated orifices and apical foramens on mesial canals were used. Teeth were randomly divided into three groups: SS K-file, Profile, LightSpeed and the root canals were instrumented using corresponding instruments from #20 to #40. All teeth were scanned with MCT before and after instrumentation. Cross section images were used to evaluate canal transportation and untouched area at 1-, 2-, 3-, and 5- mm level from the apex. Data were statistically analyzed according to 'repeated nested design' and Mann-Whitney test (p = 0.05). Results: In SS K-file group, canal transportation was significantly increased over #30 instrument. In the ProFile group, canal transportation was significantly increased after preparation with the #40 instrument at the 1- and 2- mm levels. LightSpeed group showed better centering ability than ProFile group after preparation with the #40 instrument at the 1 and 2 mm levels. Conclusions: SS K-file, Profile, and LightSpeed showed differences in the degree of apical transportation depending on the size of the master apical file.

Electrical characteristics for Multi-Nanocomposites throuh Surface Control of Epoxy/Nano_Micro $SiO_2$ Particles (Epoxy/Nano_Micro $SiO_2$입자 표면제어를 통한 멀티-나노콤포지트 전기적 특성연구)

  • Park, Young-Byum;Park, Hyun-Su;O, Chung-Yon;Kim, Hak-Jae;Park, Ki-Ryung;Lee, Dae-Kyoung;Park, Jae-Jun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.154-154
    • /
    • 2009
  • 본 연구는 고전압 전력기기인 몰드형변압기와 계기용 변성기인 CT, PT 절연특성에 유용한 Epoxy/Nano-Micro Mixture Composites(이하,ENMMC)를 개발하기위해 무엇보다 중요한 것은 Nano입자인 $SiO_2$_10nm입자의 표면을 제어하여 즉, 표면의 소수성을 크게 하여 나노입자의 균질한 분산을 얻은것이 무엇보다 중요하다. 개발된 Epoxy/$SiO_2$_10nm Nanocomposites와 Microcomposites을 기계적 전단응력을 이용하여 균질 혼합을 실시하였다. 이런 조건을 이용한 전기적특성을 측정하기위해 구대구 전극이 완전함침된 평등전계하에서 절연파괴전압을 측정하기 시편을 제조하였다. 마이크로입자의 충진함량을 일정하게 유지하여 나노입자 충진함량비율을 4가지로 변화시켜 절연파괴특성을 연구하였다. 충진함량이 나노입자의 경우 1wt%이하의 값이 상대적으로 우수한 절연파괴특성으로 와이블 플롯을 통하여 알수있었다. 상대적으로 멀티나노콤포지트의 형상파라미터가 큰 결과값을 얻을수 있었다. 그리고 스케일파리미터는 누적확률 밀도함수로서 63.2%에서 대단히 큰 초절연성의 절연소재를 개발할수 있었다.

  • PDF

Application of biodegradable metal based drug delivery carrier on Foot and Mouth Disease vaccination in pigs (돼지에서 생체 분해 금속성 전달체를 활용한 구제역 백신의 적용 연구)

  • Cho, Ara;Oh, Sang-Ik;Choe, Changyong;Jung, Young-Hun;Do, Yoon Jung;Kim, Suhee;Choo, Hyun Wook;Gu, Jong Su;Chung, Woo-Jin;Cho, Sung Youn;Yoo, Jae Gyu
    • Korean Journal of Veterinary Service
    • /
    • v.43 no.3
    • /
    • pp.129-137
    • /
    • 2020
  • In this study, we applied biodegradable drug delivery carries (BDDC) for food-and-mouth (FMD) vaccination. After FMD vaccination using BDDC, we estimated the percentage inhibition (PI) of antibody, decomposed patterns, and histopathologic features of BDDC. PI of antibody was higher than 50 at two weeks after injection and sustained positive PI until 10 weeks after injection. BBDC injection group showed significantly an increased pattern of blood monocyte at two and three weeks after injection. According to the Micro CT, micro-cracks were observed at two weeks after injection and the morphology of BDDC was lost at four weeks after injection. For histopathological examination, acute inflammation with neutrophil infiltration and micro-metallic residues were observed around BDDC until four weeks after injection and inflammatory responses gradually decreased at 10 weeks. Based on our experiment, BDDC is considered as an alternative way to vaccine injection for veterinary applications. Our study can be used as basic data for the drug delivery system using biodegradable metals in the future.