• Title/Summary/Keyword: MicroCT

Search Result 423, Processing Time 0.023 seconds

The relationship between 3D bone architectural parameters and elastic moduli of three orthogonal directions predicted from finite elements analysis (돼지 하악 과두의 해면골에서 유한요소분석법으로 예측한 방향에 따른 탄성율과 3차원 골 미세지표 간의 상관관계)

  • Park, Kwan-Soo;Lee, Sam-Sun;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.38 no.2
    • /
    • pp.81-87
    • /
    • 2008
  • Purpose: To investigate the relationship between 3D bone architectural parameters and direction-related elastic moduli of cancellous bone of mandibular condyle. Materials and Methods: Two micro-pigs (Micro-$pig^R$, PWG Genetics Korea) were used. Each pig was about 12 months old and weighing around 44 kg. 31 cylindrical bone specimen were obtained from cancellous bone of condyles for 3D analysis and measured by micro-computed tomography. Six parameters were trabecular thickness (Tb. Th), bone specific surface (BS/BV), percent bone volume (BV/TV), structure model index (SMI), degree of anisotropy (DA) and 3-dimensional fractal dimension (3DFD). Elastic moduli of three orthogonal directions (superior-inferior (SI), medial-lateral (ML), andterior-posterior (AP) direction) were calculated through finite element analysis. Results: Elastic modulus of superior-inferior direction was higher than those of other directions. Elastic moduli of 3 orthogonal directions showed different correlation with 3D architectural parameters. Elastic moduli of SI and ML directions showed significant strong to moderate correlation with BV/TV, SMI and 3DFD. Conclusion: Elastic modulus of cancellous bone of pig mandibular condyle was highest in the SI direction and it was supposed that the change into plate-like structure of trabeculae was mainly affected by increase of trabeculae of SI and ML directions.

  • PDF

Suggestion of the morphological characteristic parameters according to the Lee's physical constitution theory using X-ray computed tomography (X선 CT화상을 이용한 사상체질의 형태학적 특징 파라메타의 제안)

  • Jo, Bong-Kwan;Bae, Jong-Il;Ko, Byung-Hee;Saito, Masao
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1993 no.11
    • /
    • pp.13-16
    • /
    • 1993
  • In this paper the morphological characteristic parameters according to the Lee's physical constitution theory are suggested using the X-ray computed tomography. The Lee's physical constitution theory is classify into 4 physical constitutional types by the relative degree of visceral function: those are macro-negative(strong liver- weak lung), micro-negative(strong kidney- weak spleen), micro-positive(strong spleen- weak kidney) and macro-positive(string lung- weak liver). The morphological characteristic parameters are the following. The AA-line is the distance between Rt. & Lt. acupuncture point keug-cheun. The BB-line is the length of lung. The CC-line is the longest width of thorax. The DD-line is the vertical distance between the CC-line and the EE-line. The EE-line is the distance between the Rt. and Lt. anterior superior iliac spines. As the results macro-negative(strong liver-weak lung) has the longest CC-line and the short BB-line. Micro-negative(strong kidney-weak spleen) has the longest EE-line and the short CC-line. Micro-positive(strong spleen-weak kidney) has the longest DD-line and the short BB-line. And macro-positive(strong lung-weak kidney) has the longest BB-line and the short EE-line.

  • PDF

The Micro-Current Stimulation Inhibits Adipogenesis by Activating Wnt/β-Catenin Signaling (Wnt/β-catenin 신호 활성화를 통한 미세전류 자극의 지방생성 억제 효과)

  • Hwang, Donghyun;Lee, Hana;Lee, Minjoo;Cho, Seungkwan;Kim, Han Sung
    • Journal of Biomedical Engineering Research
    • /
    • v.41 no.6
    • /
    • pp.235-246
    • /
    • 2020
  • This study aimed to evaluate the inhibitory effect of micro-current stimulation(MCS) on adipogenesis regarding with Wnt/β-catenin pathway using the ob/ob mouse and 3T3-L1 cell line. 6-week old ob/ob male mice were equally assigned to four groups: obese group(ob), obese with MCS groups(50 μA, 200 μA, and 400 μA). 6-week old C57BL/6J male mice were assigned to the control group(CON). We analyzed abdominal adipose tissue volume by using in vivo micro-CT and measured the body weight, feed intake, liver weight and triglycerides in serum. All the MCS groups showed that significantly reduced body weight and triglycerides in serum. In the case of liver weight and abdominal adipose tissue volume, the inhibitory effect of adipogenesis was shown in the 200 μA and 400 μA groups. To elucidate the anti-obesity effect of MCS, β-catenin, C/EBPα and FAS protein expressions were analyzed by western blotting. β-catenin expression was upregulated, C/EBPα and FAS expression were down-regulated in the relatively high-intensity groups(200 μA and 400 μA). Thus, the 200 μA and 400 μA for the intensity of MCS were chosen for cell experiments. In the 3T3-L1 cell line, Wnt/β-catenin pathway including Wnt10b, Wnt3a, β-catenin and Cyclin D1 was activated in all MCS groups. Accordingly, the expression level of C/EBPα was decreased during the differentiation and lipid droplet was significantly reduced in Oil red O staining results. These results suggest that the Wnt/β-catenin signaling might be activated by MCS with current intensities between 200-400 μA and it may lead to anti-obesity effects.

Clinical Management and Micro-Computed Tomography Analysis of Supernumerary Teeth in Infancy: A Case Report (영유아기 과잉치의 임상적 처치 및 micro-computed tomography 분석: 증례 보고)

  • Chaehyun, Na;Hana, Lee;Hansung, Kim;Jihun, Kim
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.49 no.3
    • /
    • pp.348-356
    • /
    • 2022
  • Supernumerary teeth develop from excessive proliferation and development of the dental lamina. Supernumerary teeth can cause several problems, including ectopic eruption, delayed eruption, root resorption of adjacent teeth, and diastema. Supernumerary teeth in infancy are rare and have rarely been reported. Case of a 2-day-old infant with 3 supernumerary teeth is presented here and the patient was followed up for 21 months. The erupted supernumerary tooth in the primary dentition was extracted under moderate sedation at the age of 14 months. Microcomputed tomography analysis of the extracted tooth confirmed microscopic root malformation. After extraction, the midline diastema was reduced and oral hygiene improved. Early diagnosis and prompt treatment can prevent complications of supernumerary teeth.

Comparison of capsule type resin modified glass ionomer porosity according to mixing methods (혼합방법에 따른 캡슐형 광중합글라스아이노머의 공극률 비교)

  • Kim, Jung-min;Kim, Jin-Woo;Cho, Kyung-Mo;Lee, Yoon;Kim, Eung-Hyun;Park, Se-Hee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.37 no.4
    • /
    • pp.217-224
    • /
    • 2021
  • Purpose: The purpose of this study was to evaluate the porosity of resin modified glass ionomer (RMGI) by different mixing methods. Materials and Methods: Five specimens were prepared for each groups according to capsules and mixing methods. Two RMGI capsule and two mixing machines were used for this study. One resin-modified glass ionomer cement is Fuji II LC (F2LC) and the other is Photac Fil Quick Aplicap (PFQ). For Mixing of RMGI capsule, Rotomix using rotating motion and CM-II using shaking motion were used. After measuring height, radius and mass of specimens, Density was calculated. And porosity was measured using micro-computed tomography (micro-CT). All data were statistically analyzed using T-test, two-way ANOVA to compare between groups at 95% significance level to evaluate the affect of capsule and mixing method on the porosity. Results: The porosity was observed in all specimens generally. And there is significant differece between porosities according to RMGI capsule and Mixing method. The porosity of PFQ was lower than that of F2LC and the porosity of Rotomix was lower than that of CM-II. Conclusion: There was a difference of porosity according to kind of capsules and mixing methods. When using same capsule, less porosity was observed on PFQ than F2LC. When using same mixing mehod, less porosity was observed on Rotomix than CM-II. Using mixing machine of same coporation as that of RMGI capsule did not lead to lower porosity. Therefore, Selecting optimal mixing machine is important.

In vitro evaluation methods on adaptation of fixed dental prosthesis (고정성 보철물의 적합도에 대한 실험적 평가방법)

  • Lee, Hyunho;Lee, Du-Hyeong;Lee, Kyu-Bok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.2
    • /
    • pp.63-70
    • /
    • 2017
  • Clinically, the fit of fixed prosthesis is an essential element for successful restoration. The fit of prosthesis is largely classified into marginal fit and internal fit, and various methods to assess these have been introduced including microscopic margin measurement, cross-sectional measurement, silicone replica technique, 3-dimensional scanning data superposition, weight technique and micro CT scanning. Thus, this study is aimed at proposing a more convenient and accurate measurement method of fits in a digital environment by comparatively analyzing the advantages and disadvantages of each known method based on existing literature.

In vitro Estimation of The Hounsfield Units and The Volume and Void of Canine Struvite Stones as Predictors of Fragility in Extracorporeal Shock Wave Lithotripsy

  • Wang, Ji-hwan;Hwang, Tae-sung;Jung, Dong-in;Yeon, Seong-chan;Lee, Hee-chun
    • Journal of Veterinary Clinics
    • /
    • v.34 no.3
    • /
    • pp.178-184
    • /
    • 2017
  • The aim of this study was to determine whether Hounsfield units (HUs), volume, and various void parameters can predict stone fragility in extracorporeal shock wave lithotripsy (ESWL). HU, volume, porosity, number of voids/stone volume, and void distribution of 30 struvite stones were estimated using helical computed tomography (CT) and micro-CT. The number of shock waves necessary for full fragmentation was accepted as a measure of the stone fragility in ESWL. The correlations between the number of shock waves and the HU, volume, porosity, and number of voids/stone volume were examined. The number of shock waves of the two groups according to the void distribution was also compared. Stone volume correlated with the number of shock waves. Shell-patterned struvite stones were significantly less susceptible to fragmentation in ESWL than non-shell-patterned struvite stones. Stone volume and void distribution may be predictors of the outcome of ESWL treatment.

Nondestructive Evaluation of Microstructure of SiCf/SiC Composites by X-Ray Computed Microtomography

  • Kim, Weon-Ju;Kim, Daejong;Jung, Choong Hwan;Park, Ji Yeon;Snead, Lance L.
    • Journal of the Korean Ceramic Society
    • /
    • v.50 no.6
    • /
    • pp.378-383
    • /
    • 2013
  • Continuous fiber-reinforced ceramic matrix composites (CFCCs) have a complex distribution of porosity, consisting of interfiber micro pores and interbundle/interply macro pores. Owing to the complex geometry of the pores and fiber architecture, it is difficult to obtain representative microstructural features throughout the specimen volume with conventional, destructive ceramographic approaches. In this study, we introduce X-ray computed microtomography (X-ray ${\mu}CT$) to nondestructively analyze the microstructures of disk shaped and tubular $SiC_f$/SiC composites fabricated by the chemical vapor infiltration (CVI) method. The disk specimen made by stacking plain-woven SiC fabrics exhibited periodic, large fluctuation of porosity in the stacking direction but much less variation of porosity perpendicular to the fabric planes. The X-ray ${\mu}CT$ evaluation of the microstructure was also effectively utilized to improve the fabrication process of the triple-layered tubular SiC composite.

마우스 골재생모델의 제작방법 검토와 골질(bone quality) 및 골양(bone quantity) 파라미터의 해석

  • Lee, Ji-Uk;Kawahara, Keita;Nakano, Takayoshi;Kim, Seung-Eon;Yun, Hui-Suk
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2009.05a
    • /
    • pp.44.1-44.1
    • /
    • 2009
  • 최근 경조직 재생 (hard tissue regeneration) 에 대한 연구가 활발히 진행되고 있다. 그러나 이와같은 연구는 결손도입의 어려움 및 이차적인 골절의 위험성 때문에 대형동물을 중심으로 진행되고 있으며, 그 결과 동물실험에 있어서 시간적 경제적으로 큰 리스크를 수반한다. 그러나 유전자 변형동물의 대부분은 마우스이며, 분자생물학적 관점에서 골재생의 과정을 이해하기 위해서는 마우스를 이용한 골재생 모델의 확립이 필요하다. 따라서 본 연구에서는 마우스를 통해 경조직 재생모델의 제작방법을 검토함과 동시에, 골재생부위에 대한 골질 (bone quality) 및 골양 (bone quantity) 평가의 방법을 수립하는 것을 목적으로 하였다. 골결손은 생후 8주의 마우스에 시술하였다. 치과용 드릴을 이용하여 경골 (tibia) 길이의 30 % 부근의 내측(medial) 면에서 골수강 (marrow cavity) 방향으로 $500\;{\mu}m\varphi$의 원주형 결손을 도입하였다. 시술 후의 골재생과정을 관찰하기 위해 ${\mu}CT$ (SMX-100CT: Simazu) 를 이용하여 주기적으로 촬영하였으며, 골양 (BV/TV) 의 회복과정은3D-bon (RATOC) 을 이용하여 정량적인 해석을 수행하였다. 그리고 재생부의 골질 (아파타이트 배행성; BAp orientation) 평가는 투과형micro-beam XRD (R-AXIS BQ: Rigaku)를 이용하여 수행하였다.

  • PDF

The effect of high-temperature on foamed concrete

  • Canbaz, Mehmet;Dakman, Hafid;Arslan, Baris;Buyuksungur, Arda
    • Computers and Concrete
    • /
    • v.24 no.1
    • /
    • pp.1-6
    • /
    • 2019
  • Within the scope of this study, the foam solution was prepared by properly mixing sulfonate based foam agent with water. Furthermore, this solution was mixed with the mixture of fine sand, cement, and water to produce foamed concrete. The mixture ratios which are the percentage of foam solution used in foam concrete were chosen as 0, 20, 40 and 60% by vol. After these groups reached 28 days of strength, they were heated to 20, 100, 400 and $700^{\circ}C$ respectively. Afterward, high-temperature effects on the foamed concrete were obtained by employing physical and mechanical properties tests. Additionally, SEM (scanning electron microscope) and EDX (energy-dispersive X-ray spectroscopy) tests were employed to analyze the microstructure, and ${\mu}-CT$ (micro computed tomography) images were used to reconstruct 3-D models of the heat-treated specimens. Then, these models are analyzed to examine the void structures and the changes in these structures due to the high temperatures. The study has shown that the void structures reduce the high-temperature effects and the foam solution could be mixed with concrete up to 40 % by vol. where the high strength of foamed concrete is non-mandatory.