• 제목/요약/키워드: Micro-sized

Search Result 405, Processing Time 0.028 seconds

Preparation of Mono-dispersed Polyamide 6(Nylon 6) Micro-particle (단분산린 Polyamide 6(Nylon 6) 미세입자의 제조)

  • Cho, Hangu-Gu;Kim, Hyung-Joong
    • Polymer(Korea)
    • /
    • v.31 no.4
    • /
    • pp.322-328
    • /
    • 2007
  • Mono-dispersed polyamide 6(Nylon 6) micro-particles sized in $4{\sim}5\;{\mu}m$ diameter were prepared by dispersion polymerization of ${\varepsilon}-caprolactam$ in liquid paraffin as a dispersion medium. Potassium metal(K) as a catalyst was separately added twice over the anionic ring-opening polymerization of ${\varepsilon}-caprolactam$. The size, shape, and size-distribution of prepared particles were varied with the concentration of anti-coagulant as well as the amount of initiator and catalyst. As the initiator concentration was in the range of $0.97{\sim}1.17\;wt%$ in monomer, about 90.6% of yield was accomplished. In addition, the highest yield of well-spherically shaped micro-particles was achieved by adding about $1.3{\sim}1.4\;wt%$ of catalyst.

Low Temperature Hermetic Packaging using Localized Beating (부분 가열을 이용한 저온 Hermetic 패키징)

  • 심영대;김영일;신규호;좌성훈;문창렬;김용준
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.1033-1036
    • /
    • 2002
  • Wafer bonding methods such as fusion and anodic bonding suffer from high temperature treatment, long processing time, and possible damage to the micro-scale sensor or actuators. In the localized bonding process, beating was conducted locally while the whole wafer is maintained at a relatively low temperature. But previous research of localized heating has some problems, such as non-uniform soldering due to non-uniform heating and micro crack formation on the glass capsule by thermal stress effect. To address this non-uniformity problem, a new heater configuration is being proposed. By keeping several points on the heater strip at calculated and constant potential, more uniform heating, hence more reliable wafer bonding could be achieved. The proposed scheme has been successfully demonstrated, and the result shows that it will be very useful in hermetic packaging. Less than 0.2 ㎫ contact Pressure were used for bonding with 150 ㎃ current input for 50${\mu}{\textrm}{m}$ width, 2${\mu}{\textrm}{m}$ height and 8mm $\times$ 8mm, 5mm$\times$5mm, 3mm $\times$ 3mm sized phosphorus-doped poly-silicon micro heater. The temperature can be raised at the bonding region to 80$0^{\circ}C$, and it was enough to achieve a strong and reliable bonding in 3minutes. The IR camera test results show improved uniformity in heat distribution compared with conventional micro heaters. For gross leak check, IPA (Isopropanol Alcohol) was used. Since IPA has better wetability than water, it can easily penetrate small openings, and is more suitable for gross leak check. The pass ratio of bonded dies was 70%, for conventional localized heating, and 85% for newly developed FP scheme. The bonding strength was more than 30㎫ for FP scheme packaging, which shows that FP scheme can be a good candidate for micro scale hermetic packaging.

  • PDF

Development of Micro Wired pH Electrode for Real-Time Monitoring for Gastroesophageal Reflux (위식도 역류 실시간 모니터링 마이크로 와이어 pH 전극 개발)

  • Kim, Eung-Bo;Lee, Kyu-Jin;So, Sang-Kyun;Joung, Yeun-Ho;Park, Jung Ho;Kim, Nam Hee
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.6
    • /
    • pp.277-284
    • /
    • 2017
  • This paper presents an implantable pH measurement electrode for wireless gastroesophageal reflux measurement. Usually, gastroesophageal reflux is diagnosed by a catheter-type wire connection between the esophagus and the diagnostic device which brings many side effects such as restriction of daily living, pain, and discomfort in the nasal cavity and pharynx of patients. In order to solve these issues, researchers have been studied a wireless measurement method and a micro-sized pH electrode for human body insertion is necessary. Commercial glass packaged pH meter is formed by a sensing and a reference electrodes in a KCl solution. However, if the glass meter is inserted into the human body, there are risks of leakage of the solution, breakage of the glass package, injury of the body elements. Therefore, the solution should be solidified on the micro-sized noble metal wire which has a characteristic of biocompatible. After solidified wire fabrication, the designed meter was tested for feasibility of measurement and the result was well agreed with pH values of commercial pH meter. Potentials in pH 1 to 12 solution was measured to obtain the sensitivity of the sensor with linearity. And we have designed a simulation of gastroesophageal reflux with symptom frequency, interval, and duration time in pH 2 solution. The proposed sensor has capable to get the same potential for 24 measurements in 3 days, and it has sensed same pH values of 2 for one hour with every 10 minutes. Furthermore, the sensor was survived for 48 hours with reasonable potentials in the acid solution.

Performance characteristics of AGM lead acid battery with the content of positive plate incorporating nano-size additive material (나노 사이즈 입자가 포함된 양극 활물질 함량에 따른 차량용 AGM 연축전지 성능 특성)

  • Lim, Tae Seop;Kim, Sung Jun;Kim, Sang Dong;Yang, Seung Cheol;Jung, Yeon Gil
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.30 no.4
    • /
    • pp.123-130
    • /
    • 2020
  • Nano seed incorporated in micro-sized 4BS (Tetrabasic lead Sulfate) seed was applied to the positive electrode active material and compared with Nano 4BS seed (NS). The dispersion of NS decreased due to the aggregation phenomenon, while the nano seed incorporated in micro-sized 4BS seed (INS) could confirm excellent dispersion. As the content of INS increased, the particle size of the active material became small and constant, which was confirmed through SEM and particle size analysis. The specific surface area for the reaction was increased and the high-rate discharge and lifetime characteristics were improved. In order to confirm the variation in particle size distribution in the plate manufacturing process, internal resistance and voltage were measured for 200 AGM lead-acid batteries, and it was confirmed that batteries quality variation decreased.

KAUSAT-5 Development and Verification based on 3U Cubesat Standard Platform (3U 큐브위성 표준 플랫폼에 기반한 한누리 5호 개발 및 검증)

  • Song, Sua;Lee, Soo-Yeon;Kim, Hong-Rae;Chang, Young-Keun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.45 no.8
    • /
    • pp.686-696
    • /
    • 2017
  • The major objective of this study is to develop and verify the KAUSAT-5 based on the modular 3U CubeSat standard platform. In the mechanical system design of a 3U standard platform, subsystem and micro equipment functions/performance should be integrated and miniaturized on micro-sized PCBs and electrical capability was maximized to accommodate multiple payloads. KAUSAT-5 is 3U-sized Cubesat which will be operated in Low Earth Orbit(LEO), which implements mainly two scientific missions; one is to observe the Earth through infrared camera and the other is to measure space radiation with a Geiger Muller tube. An additional mission is to verify the equipment(device) such as VSCMG and fuzzy logic-based MPPT internally developed. The results of ETB, qualification and acceptance level environmental tests were shown to verify standard platform and KAUSAT-5 Cubesat.

Hydrophobic and Hydrophilic PDMS Sponges Prepared Through Physicochemical Treatments (물리화학적 처리에 따른 PDMS 특성 조절)

  • Nam, Kyungmok;Park, Sungmin;Kim, Jonghun;Yoon, Sang-Hee
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.8
    • /
    • pp.737-742
    • /
    • 2016
  • An elastomer (especially PDMS) sponge is considered to be a promising selective absorber in cleaning up oil spills. The performance of a PDMS sponge in capturing and separating oil from (sea) water depends on several parameters such as surface roughness, physicochemical treatments, and hydrostatic stability. Here, we first present a method of fabricating the PDMS sponges having numerous micro-sized pores that act as absorption and storage spaces for the target material, and then we report an experimental effort undertaken to control the surface physicochemistry (i.e., hydrophobicity or hydrophilicity) of the PDMS sponges by adjusting the size of the pores and the concentration of the surfactant (i.e., silwet L-77). From the experimental results, we develop an in-depth understanding of the mechanism for controlling the surface physicochemistry of PDMS using water-soluble micro-sized particles and a surfactant. The surface energy and absorbing behavior of the PDMS sponges are also extensively discussed.

Synthesis and Characteristics of CU/CUO Nanopowders by Pulsed Wire Evaporativn(PWE) Method (전기폭발법에 의한 CU/CUO 나노분말의 제조 및 분말특성)

  • Maeng, D.Y.;Rhee, C.K.;Lee, N.H.;Park, J.H.;Kim, W.W.;Lee, E.G.
    • Korean Journal of Materials Research
    • /
    • v.12 no.12
    • /
    • pp.941-946
    • /
    • 2002
  • Both Cu and Cu-oxide nanopowders have great potential as conductive paste, solid lubricant, effective catalysts and super conducting materials because of their unique properties compared with those of commercial micro-sized ones. In this study, Cu and Cu-oxide nanopowders were prepared by Pulsed Wire Evaporation (PWE) method which has been very useful for producing nanometer-sized metal, alloy and ceramic powders. In this process, the metal wire is explosively converted into ultrafine particles under high electric pulse current (between $10^4$ and $10^{ 6}$ $A/mm^2$) within a micro second time. To prevent full oxidations of Cu powder, the surface of powder has been slightly passivated with thin CuO layer. X-ray diffraction analysis has shown that pure Cu nanopowders were obtained at $N_2$ atmosphere. As the oxygen partial pressure increased in $N_2$ atmosphere, the gradual phase transformation occurred from Cu to $Cu_2$O and finally CuO nanopowders. The spherical Cu nanopowders had a uniform size distribution of about 100nm in diameter. The Cu-oxide nanopowders were less than 70nm with sphere-like shape and their mean particle size was 54nm. Smaller size of Cu-oxide nanopowders compared with that of the Cu nanopowders results from the secondary explosion of Cu nanopowders at oxygen atmosphere. Thin passivated oxygen layer on the Cu surface has been proved by XPS and HRPD.

Study of Nano-scale Fullerene (C60) Clusters Formed in Micro-sized Droplet by UV Irradiation

  • Yeo, Seung-Jun;Ahn, Jeung-Sun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.571-571
    • /
    • 2012
  • We discovered the formation of C60 aggregates in solution by means of photoluminescence spectroscopic study on C60 in solutions. From the in-depth investigation of temperature dependence of the luminescence of C60 in toluene, benzene and CS2 solutions, we reported that the C60 aggregates are formed during cooling at the freezing temperature of these solvents. Furthermore, the C60 aggregates can be changed to stable structures by irradiating with UV pulse-laser (Nd:YAG laser, 355nm). As a consequence, we could obtain nano-scale photo-polymerized C60 clusters, which appear as round-shaped nano- scale particles in high resolution transmission electron-microscopy (HRTEM) images. However, the yield of the nano-scale C60 clusters obtained by this method is too small. So we designed and developed a system to obtain C60 cluster of macroscopic quantity by using ultrasonic nebulizer. In this system, C60 solution was vaporized to several micro-sized droplets in vacuum, resulting in the formation of C60 aggregates by evaporating solvent (toluene). The system was invented to produce nano-scale carbon clusters by the irradiation of UV light upon C60 aggregates in vacuum. We have characterized the products, C60 cluster, obtained from the system by using UV absorption spectra and HPLC spectra. Although the products have a possibility of inclusion various forms of C60 cluster, results support that the product formed from the system by using vaporizer method establishes a new method to obtain C60 cluster in macroscopic quantity. In the presentation, the details of the system and the results of characterization are reported.

  • PDF

A Study of Homogeneous Sterilization of Micro-sized Food Powder by Rotatable Low-Temperature Plasma System (회전형 저온 플라즈마 시스템을 이용한 분말식품의 균일한 살균 연구)

  • Kim, Myung Chan;Park, Duck Mo;Han, Jin Soo;Woo, In Bong;Kim, Dong Hoo;Jang, Seong Eun;Yoon, Chan Suk;Kim, In
    • The Korean Journal of Food And Nutrition
    • /
    • v.31 no.2
    • /
    • pp.301-307
    • /
    • 2018
  • In this study, a relatively effective process is used to sterilize Escherichia coli on the surface of micro-sized calcium citrate powder using nitrogen and argon as process gases in a low-temperature vacuum plasma treatment. The purpose of this study is to confirm and to introduce the effectiveness of homogeneous surface treatment for the sterilization of fine inorganic powder by the rotatable low-temperature RF plasma system designed by ourselves. The results of the test using 3M petrifilm showed that there were no remarkable spots in the case of the surface of plasma treated powder, whereas the untreated powder showed many blue spots, which indicating that the E. coli was alive. After 5 days, in the same samples, the blue spots were seen to be larger and darker than before, while the plasma-treated powder showed no changes. The results from FE-SEM analysis showed that the E. coli was damaged and/or destroyed by reactive species generated in the plasma space, resulting in the E. coli being sterilized. Furthermore, the sterilization effects according to the selected parameters ($N_2$ and Ar; flow rate 30 and 50 sccm) adapted in this study were mutually similar, regardless of such different process parameters, and this indicates that homogeneous treatment of powder surfaces could be more effective than conventional methods. Therefore, the plasma apparatus used in this study may be a practical method to use in a powerful sterilization process in powder-type food.

Rheological Investigation of Aluminized Paraffin Wax Fuel on Particle Size and Contents (파라핀/알루미늄 연료의 알루미늄 입자크기 및 함유비 변화에 따른 유변학적 특성)

  • Ryu, Sunghoon;Han, Seongjoo;Moon, Heejang;Kim, Jinkon;Kim, Junhyung;Ko, Seungwon
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.22 no.2
    • /
    • pp.11-19
    • /
    • 2018
  • Viscosity measurements were conducted to investigate the rheological characteristics of aluminized paraffin wax fuel. To identify the effect of size and contents of the aluminum particles on the variation of viscosity, samples of nano- and micro- sized aluminum particles with an average particle size of 100 nm and $8{\mu}m$ were prepared and measured using a rheometer. The observed viscosity increment patterns of the nano- and micro-sized particles were vey different, and particularly above 10 wt%, where a relatively low overall regression rate is expected for nano- content fuel. It is possible that this phenomenon could cause the reduced entrainment regression rate.