• Title/Summary/Keyword: Micro-sensor

Search Result 994, Processing Time 0.036 seconds

Design and Fabrication of Low Power Sensor Network Platform for Ubiquitous Health Care

  • Lee, Young-Dong;Jeong, Do-Un;Chung, Wan-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1826-1829
    • /
    • 2005
  • Recent advancement in wireless communications and electronics has enabled the development of low power sensor network. Wireless sensor network are often used in remote monitoring control applications, health care, security and environmental monitoring. Wireless sensor networks are an emerging technology consisting of small, low-power, and low-cost devices that integrate limited computation, sensing, and radio communication capabilities. Sensor network platform for health care has been designed, fabricated and tested. This system consists of an embedded micro-controller, Radio Frequency (RF) transceiver, power management, I/O expansion, and serial communication (RS-232). The hardware platform uses Atmel ATmega128L 8-bit ultra low power RISC processor with 128KB flash memory as the program memory and 4KB SRAM as the data memory. The radio transceiver (Chipcon CC1000) operates in the ISM band at 433MHz or 916MHz with a maximum data rate of 76.8kbps. Also, the indoor radio range is approximately 20-30m. When many sensors have to communicate with the controller, standard communication interfaces such as Serial Peripheral Interface (SPI) or Integrated Circuit ($I^{2}C$) allow sharing a single communication bus. With its low power, the smallest and low cost design, the wireless sensor network system and wireless sensing electronics to collect health-related information of human vitality and main physiological parameters (ECG, Temperature, Perspiration, Blood Pressure and some more vitality parameters, etc.)

  • PDF

A Wireless Intraocular Pressure Sensor with Variable Inductance Using a Ferrite Material

  • Kang, Byungjoo;Hwang, Hoyong;Lee, Soo Hyun;Kang, Ji Yoon;Park, Joung-Hu;Seo, Chulhun;Park, Changkun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.13 no.4
    • /
    • pp.355-360
    • /
    • 2013
  • A wireless intraocular (IOP) pressure sensor based on micro electro mechanical system (MEMS) technology is proposed. The proposed IOP sensor uses variable inductance according to the external pressure. The proposed sensor is composed of two flexible membranes: a ferrite bottom part, an inductor, and a capacitor. The inductance of the sensor varies according to the external pressure. The resonance frequency of the sensor is also varied, and this frequency is detected using an external coil. The external coil is designed with an FR-4 printed circuit board. The feasibility of the proposed sensor structure using variable inductance to detect the external pressure is successfully demonstrated.

Fabrication and Characteristic Analysis of a Flexible Tactile Sensor Using PVDF (PVDF를 이용한 유연 촉각센서의 제작 및 특성해석)

  • 윤명종;권대규;유기호;이성철
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.390-390
    • /
    • 2000
  • This research is the development of a skin-type tactile sensor for service robot using PVDF film for the detection of the contact state. The Prototype of the tactile sensor which has 8$\times$8 taxels was fabricated using PVDF film In the fabrication procedure of the sensor, the electrode patterns and common electrode of the thin conductive tape were attached to the both side of the 28 micro meter thickness PVDF film using conductive adhesive. The sensor was covered with polyester film for insulation and attached to the rubber base for making stable structure. The signals of a contact pressure to the tactile sensor were sensed and processed in the DSP system in which the signals were digitized and filtered. Finally, the signals were integrated for taking the force profile. The processed signals of the output of the sensor were visualized in PC, the shape and force distribution of the contact object were obtained. The reasonable performance for the detection of contact state was verified through the experiment.

  • PDF

Methane sensing characteristics and power consumption of MEMS gas sensor based on ZnO nanowhiskers (ZnO 나노휘스커 소재를 이용한 MEMS가스센서의 소비전력과 메탄 감응 특성 연구)

  • Moon, Hyung-Shin;Park, Sung-Hyun;Kim, Sung-Eun;Yu, Yun-Sik
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.462-468
    • /
    • 2010
  • A low power gas sensor with microheater was fabricated by MEMS technology. In order to heat up the gas sensing material to a operating temperature, a platinum(Pt) micro heater was built on to the micromachined Si substrate. The width and gap of microheater were $20\;{\mu}m$ and $4.5\;{\mu}m$, respectively. ZnO nanowhisker arrays were fabricated on a sensor device by hydrothermal method. The sensor device was deposited with ZnO seeds using PLD systems. A 200 ml aqueous solution of 0.1 mol zinc nitrate hexahydrate, 0.1 mol hexamethylenetetramine, and 0.02 mol polyethylenimine was used for growthing ZnO nanowhiskers. The power consumption to heat up the gas sensor to a operating temperature was measured and temperature distribution of sensor was analyzed by a Infrared Thermal Camera. The optimum temperature for highest sensitivity was found to be $250^{\circ}C$ although relatively high(64 %) sensitivity was obtained even at as low as $150^{\circ}C$. The power consumption was 72 mW at $250^{\circ}C$ and was only 25 mW at $150^{\circ}C$.

Limit-current type zirconia oxygen sensor with porous diffusion layer (다공성 확산층을 이용한 한계전류형 지르코니아 산소센서)

  • Oh, Young-Jei;Lee, Chil-Hyoung
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.5
    • /
    • pp.329-337
    • /
    • 2008
  • Simple, small and portable oxygen sensors were fabricated by tape casting technique. Yttria stabilized zirconia containing cordierite ceramics (YSZC) were used as a porous diffused layer of oxygen in pumping cell. Yttria stabilized zirconia (YSZ) solid electrolyte, YSZC porous diffusion layer and heater-patterned ceramic sheets were prepared by co- firing method. Limit current characteristics and the linear relationship of current to oxygen concentration were observed. Viscosity variation of the slurries both YSZ and YSZC showed a similar behavior, but micro pores in the fired sheet were increased with increasing of the cordierite amount. Molecular diffusion was dominated due to the formation of large pores in porous diffusion layer. The plateau range of limit current in porous-type oxygen sensor was narrow than the one of aperture-type oxygen sensor. However limit current curve was appeared in porous-type oxygen sensor even at the lower applied voltage. The plateau range of limit-current was widen as increasing the thickness of porous diffusion layer of the YSZ containing cordierite. Measuring temperature of $600{\sim}650^{\circ}C$ was recommended for limit-current oxygen sensor. Porous diffusion layer-type oxygen sensor showed faster response than the aperture-type one and was stable up to 30 days running without any crack at interface between the layers.

Application of sensor and MEMS in medicine (의료에서의 센서와 MEMS 기술 응용)

  • ;Lee, Sang Soon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.1536-1540
    • /
    • 1997
  • Recently, many advanced technologies in electronics, mechanics, material and computer science have been applied to medictine and they have changed the method of diagnosis and treatment to more quantitative way than before. Now day, with the aid of this technology, the device for the minimal invasive diagnosis and treatment is being developed for the convenience and safety of patients. this paper introduces application of senso and MEMS(Micro Electro Mechnical System) in medicine and biotechnology, which are essential factor for the realization of minimal invasive diagnosis and treatment.

  • PDF

Development of Data Logger for Environmental Tele Monitoring System (원격 환경 모니터링을 위한 Data Logger 개발)

  • 정광조;이재종;이수호
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1097-1100
    • /
    • 2003
  • Data Loggers for environmental monitoring are mostly dispersion in installation and systems located at long distance from monitoring system. And, it requests mostly flexible functions and high performances. that can fit to various sensor inputs, sensor interfaces and conditions or system working. In this research, we developed the micro controller based Data Logger with minimum hardware construction that allows the higher flexibility of application. Finally, we developed software function for water quality monitoring and tested in real system launched at Han river.

  • PDF

Fiber-Optic Sensor for Acoustic Waves (광섬유를 이용한 음파탐지기의 제작)

  • 유회준;이경목;황준암
    • Proceedings of the Korean Institute of Communication Sciences Conference
    • /
    • 1983.10a
    • /
    • pp.44-47
    • /
    • 1983
  • Through intensity modulation induced by micro bending of an optical fiber, a sensor detects the pressure and frequency of acoustic wave has been implemented. Axial slots on the cylinder suface with a period of 5.5 mm induce efficient microbending of the fiber, and a rubber sleeve covering the fiber enhances the fiber. Compared with a conventional hydrophone, it has a low minimum detectable pressure and can detect acoustic wave in 100Hz - 2KHz range.

  • PDF

Development of Inductive and Capacitive Type Intraocular Pressure (IOP) Sensor to Improve Sensitivity and Minimize Size (민감도 향상과 센서 소형화를 위한 자기 및 용량형 안압센서의 개발)

  • Jang, Cheol In;Shin, Kyeong-Sik;Yun, Kwang-Seok;Kim, Yong Woo;Kang, Ji Yoon;Lee, Soo Hyun
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.6
    • /
    • pp.409-415
    • /
    • 2014
  • We had presented an inductive type intraocular pressure sensor (L-sensor) in previous work. The distance between a micro coil and a ferrite on the membrane was modulated by pressure, and as a result the inductance and resonant frequency were changed. However, L-sensor has some problems to implant in eyes. First problem is low sensitivity. When L-sensor was implanted in rabbit's eyes, resonant frequency of L-sensor was very hard to detect. Second problem is biocompatibility. Size of L-sensor is $6{\times}7{\times}1.2mm$. When L-sensor was implanted in the eyes, it caused the inflammation. Therefore, this study suggests an inductive and capacitive type IOP sensor (LCsensor). The sensitivity of the LC-sensor 27.3 kHz/mmHg under 60mmHg. It is much larger than 14 kHz/mmHg of the L-sensor. And the size of LC-sensor is 47% smaller than L-sensor. After 2 weeks from the implantation of LC-sensor into rabbit eyes, we measured the changes of resonant frequency of LC-sensor according to increased IOP by Balanced Salt Solution (BSS) injection. As a result, the sensitivity of LC-sensor in in vivo test is 25 kHz/mmHg. That is similar to the sensitivity of in vitro test.