• Title/Summary/Keyword: Micro-scale

Search Result 1,171, Processing Time 0.037 seconds

Spatio-temporal Visualization of PM10 Flow Pattern Using Gravity Model (중력모델을 적용한 미세먼지 흐름 패턴 시공간 시각화)

  • Lee, Geon-Woo;Yom, Jae-Hong
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.37 no.6
    • /
    • pp.417-426
    • /
    • 2019
  • Conventional visualization of PM (Particulate Matter)10 flows applies superimposition of concentration distribution maps and wind field maps. This method is efficient for small scale maps where only macro flow trends are of interest. However, in the case of urban areas, local flows are difficult to model at micro level using wind fields, and therefore different methods of flow extraction is deemed necessary. In this study, flow information is extracted and visualized directly from the PM10 density data by using the gravity model. This method has the advantage that additional information such as wind field is not necessary for estimating the intensity and direction of PM10 flow. The extracted spatio-temporal flow patterns of PM10 are analyzed with relation to traffic information.

SPACE PHYSICS PACKAGE ON KAISTSAT-4 (과학위성 1호의 우주 플라즈마 관측 시스템)

  • HWANG JUNG-A;LEE JAE-JIN;LEE DAE-HEE;LEE JIN-GUN;KIM HEE-JUN;PARK JAE-HEUNG;MIN KYOUNG WOOK;SHIN YOUNG-HOON
    • Publications of The Korean Astronomical Society
    • /
    • v.15 no.spc2
    • /
    • pp.45-52
    • /
    • 2000
  • Four plasma instruments are currently under development for KAISTSAT-4 (K-4) which is scheduled for launch in 2002. They are the Solid-State Telescope, Electro-Static Analyzer, Langmuir Probe, and the Scientific Magnetometer, that will respectively allow in-situ detection of high energy and low energy components of auroral particles, ionospheric thermal electrons, and magnetic field disturbances. These instruments, together with the Far-ultraviolet IMaging Spectrograph, will provide micro-scale physics of Earth's polar ionosphere with detailed spectral information that has not been previously achieved with other space missions. In this paper, we review the concept of the four space plasma instruments as well as the anticipated results from the instruments.

  • PDF

Donor-Site Morbidity after Partial Second Toe Pulp Free Flap for Fingertip Reconstruction

  • Kim, Hyung Su;Lee, Dong Chul;Kim, Jin Soo;Roh, Si Young;Lee, Kyung Jin;Yang, Jae Won;Ki, Sae Hwi;Harijan, Aram
    • Archives of Plastic Surgery
    • /
    • v.43 no.1
    • /
    • pp.66-70
    • /
    • 2016
  • Background In this study, we characterize the morbidity at the donor-site of partial second toe pulp free flaps in terms of wound management as well as long-term outcomes. Methods A single-institutional retrospective review was performed for patients who had undergone partial second toe pulp free flap transfer to the fingertip. Patient charts were reviewed for infection, skin necrosis, wound dehiscence, and hematoma for the donor site. Additionally, a questionnaire survey was given to patients who had a follow-up of longer than 1 year to characterize long-term postoperative pain and appearance. Results The review identified a total of 246 cases. Early wound complications were significant for wound dehiscence (n=8) and hematoma (n=5) for a wound complication rate of 5.3%. The questionnaire was distributed to 109 patients, and 54 patients completed the survey. Out of these 54 patients, 15 patients continued to have donor-site pain (28%) at a mean follow-up period of 32.4 months. However, the pain intensity was relatively low in the range between 2 to 5, on a 0-10 scale. None of these patients felt this donor-site pain interfered significantly with daily activity, nor did any patient require pain medications of any type. Donor-site appearance was satisfactory to most patients. Conclusions The partial second toe pulp flap was associated with low rates of wound complications and favorable long-term outcomes. Given the functional and aesthetic gain in the recipient finger, donor-site morbidities appear acceptable in this patient population. This study can be helpful in counseling patients regarding donor-site morbidity during the informed consent process.

Laser-induced chemical vapor deposition of micro patterns for TFT-LCD circuit repair (레이저 국소증착을 이용한 TFT-LCD 회로수정 패턴제조)

  • Park Jong-Bok;Jeong Sungho;Kim Chang-Jae;Park Sang-Hyuck;Shin Pyung-Eun;Kang Hyoung-Shik
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.657-662
    • /
    • 2005
  • In this study, the deposition of micrometer-scale metallic interconnects on LCD glass for the repair of open-circuit type defects is investigated. Although there had been a few studies Since 1980 s for the deposition of metallic interconnects by laser-induced chemical vapor deposition, those studies mostly used continuous wave lasers. In this work, a third harmonic Nd:YLF laser (351nm) of high repetition rates, up to 10 KHz, was used as the illumination source and $W(CO)_6$ was selected as the precursor. General characteristics of the metal deposit (tungsten) such as height, width, morphology as well as electrical properties were examined for various process conditions. Height of the deposited tungsten lines ranged from 35 to 500 nm depending on laser power and scan speed while the width was controlled between $3\~50{\mu}$ using a slit placed in the beam path. The resistivity of the deposited tungsten lines was measured to be below 1 $O\cdot{\mu}m$, which is an acceptable value according to the manufacturing standard. The tungsten lines produced at high scan speed had good surface morphology with little particles around the patterns. Experimental results demonstrated that it is likely that the deposit forms through a hybrid process, namely through the combination of photolytic and pyrolytic mechanisms.

  • PDF

Advanced Wastewater Treatment using Bioreactor Combined with Alternative Membrane (하수의 고도처리를 위한 저비용 저에너지의 대체 막을 조합한 생물반응기의 개발)

  • Kim, Dong-Ha
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.1
    • /
    • pp.25-30
    • /
    • 2005
  • In order to decrease the high costs of membrane process, we have tried to develop two alternatives to membrane; a cartridge type filter and a metal membrane were tested for the high permeation flux with low cost and low energy. This research mainly focused on three points; 1) operation with high permeation flux by using of a cartridge type filter and a metal membrane, 2) removals of the filterable organic materials (FOC) by pretreatments for the membrane fouling control, and 3) advanced wastewater treatment by SMBR process with intermittent aeration and high MLSS. An Intermittently aerated membrane bioreactor using a submerged micro filter (cartridge type) was applied in laboratory scale for the advanced wastewater treatment. To minimize membrane fouling, intermittent aeration was applied inside of the filter with $3.0kg_f/cm^2$. The experiments was conducted for 6 months with three different HRTs (8, 10, 12 hr) and high MLSS of 6,000 and 10,000mg/L. The filtration process could be operated up to 50 days with permeation flux of 500LMH. Regardless of the operating conditions, more than 95% of COD, BOD and SS were removed. Fast and complete nitrification was accomplished, and denitrification was appeared to be the rate-limiting step. More than 75% T-N could be removed due to the endogenous denitrification. T-P removal efficiency was increased to 80% under the condition of MLSS 10,000mg/L.

Study on the Optimal Release Condition of Wafer Level Molding Process using Plasma Surface Treatment Method (플라즈마 표면처리 방법을 이용한 웨이퍼레벨 몰딩 공정용 기판의 최적 이형조건 도출)

  • Yeon, Simo;Park, Jeonho;Lee, Nukkyu;Park, Sukhee;Lee, Hyejin
    • Journal of Institute of Convergence Technology
    • /
    • v.5 no.1
    • /
    • pp.13-17
    • /
    • 2015
  • In wafer level molding progress, the thermal releasing failure phenomenon is shown up as the important problem. This phenomenon can cause the problem including the warpage, crack of the molded wafer. The thermal releasing failure is due to the insufficiency of adhesion strength degradation of the molding tape. To solve this problem, we studied experimental method increasing the release property of the molding tape through the plasma surface treatment on the wafer substrate. In this research, the vacuum plasma treatment system is used for release property improvement of the molding tape and controls the operating condition of the hydrophilic($O_2$, 100kW, 10min) and hydrophobic($C_2F_6$, 200kW, 10min). In order to perform the peeling test for measuring the releasing force precisely, we remodel the micro scale material property evaluation system developed by Korea institute of industrial technology. In case of hydrophilic surface treatment on the wafer substrate, we can figure out the releasing property of molding tape increase. In order to grasp the effect that it reaches to the release property increase when repeating the hydrophilic treatment, we make an experiment with twice treatment and get the result to increase about 12%. We find out the hydrophilic surface treatment method using plasma can improve releasing property of molding tape in the wafer level molding process.

Implementation of a DSP Based Fuel Cell Hardware Simulator (DSP기반 연료전지 하드웨어 시뮬레이터 구현)

  • Oum, Jun-Hyun;Lim, Young-Cheol;Jung, Young-Gook
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.1
    • /
    • pp.59-68
    • /
    • 2009
  • Fuel cell generators as the distributed generation system with a few hundred watt$\sim$a few hundred kilowatt capacity, can supply the high quality electric power to user as compared with conventional large scale power plants. In this paper, PEMFC(polymer electrolyte membrane fuel cell) generator as micro-source is modelled by using PSIM simulation software and DSP based fuel cell hardware simulator based on the PSIM simulation model is implemented. The relation of fuel cell voltage and current(V-I curve) is linearized by first order function on the ohmic area in voltage-current curve of fuel cell. The implemented system is composed of a PEMFC hardware simulator, an isolated full bridge dc boost converter, and a 60[Hz] voltage source PWM inverter. The voltage-current-power(V-I-P) characteristics of the implemented fuel cell hardware simulator are verified in load variation and transient state and the 60[Hz] output voltage sinusoidal waveform of the PWM inverter is investigated under the resistance load and nonlinear diode load.

Investigation on the Size Effects of Polycrystalline Metallic Materials in Microscale Deformation Processes (미세성형 공정에서 다결정 금속재료의 크기효과에 관한 연구)

  • Kim, Hong-Seok;Lee, Yong-Sung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.10
    • /
    • pp.1463-1470
    • /
    • 2010
  • Microforming, which exploits the advantages of metal forming technology, appears very promising in manufacturing microparts since it enables the production of parts using various materials at a high production rate, it has high material utilization efficiency, and it facilitates the production of parts with excellent mechanical properties. However, the conventional macroscale forming process cannot be simply scaled down to the micro-scale process on the basis of the extensive results and know-how on the macroscale process. This is because a so-called "size effect" occurs as the part size decreases to the microscale. In this paper, we attempt to develop an effective analytical and experimental modeling technique for explaining the effects of the grain size and the specimen size on the behavior of metals in microscale deformation processes. Copper sheet specimens of different thicknesses were prepared and heat-treated to obtain various grain sizes for the experiments. Tensile tests were conducted to investigate the influence of specimen thickness and grain size on the flow stress of the material. In addition, an analytical model was developed on the basis of phenomenological experimental findings to quantify the effects of the grain size and the specimen size on the flow stress of the material in microscale and macroscale forming.

Fracture Behavior of Glass/Resin/Glass Sandwich Structures with Different Resin Thicknesses (서로 다른 레진 두께를 갖는 유리/레진/유리샌드위치 구조의 파괴거동)

  • Park, Jae-Hong;Lee, Eu-Gene;Kim, Tae-Woo;Yim, Hong-Jae;Lee, Kee-Sung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.12
    • /
    • pp.1849-1856
    • /
    • 2010
  • Glass/resin/glass laminate structures are used in the automobile, biological, and display industries. The sandwich structures are used in the micro/nanoimprint process to fabricate a variety of functional components and devices in fields such as display, optics, MEMS, and bioindustry. In the process, micrometer- or nanometer-scale patterns are transferred onto the substrate using UV curing resins. The demodling process has an important impact on productivity. In this study, we investigated the fracture behavior of glass/resin/glass laminates fabricated via UV curing. We performed measurements of the adhesion force and the interfacial energy between the mold and resin materials using the four-point flexural test. The bending-test measurements and the load-displacement curves of the laminates indicate that the fracture behavior is influenced by the interfacial energy between the mold and resin and the resin thickness.

Measurement of Geometric Errors of an Ultra Precision mMT Using PSDs (PSD를 이용한 초정밀소형공작기계의 기하학적 오차 측정)

  • Kwon, Seol-Ryung;Kweon, Sung-Hwan;Yang, Seung-Han
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.1
    • /
    • pp.53-58
    • /
    • 2011
  • Ultra-precision miniaturized machine tools essential for manufacturing accurate machine components in micro/meso-scale have been developed. To realize high accuracy using mMTs, geometric errors, which are considered as the main sources of inaccuracy should be identified and compensated. The conventional systems for measuring geometric errors, such as a laser interferometer, can measure only one geometric error in a single setup and they involve complicated measurement procedures. A measurement system using PSDs is a promising alternative but the measurable range of such systems is limited to the active range of the PSDs. The proposed measurement system using PSDs can overcome the limit of small measurable range. Further, the mounting errors that could occur during set-up process can be avoided. In this paper, an algorithm corresponding to the system was analyzed and experiments were carried out.