• 제목/요약/키워드: Micro-deformation

검색결과 483건 처리시간 0.022초

적층형 압전재료를 이용한 초정밀 선형 모터에 관한 연구 (Research for ultra precision linear motor by using piezo stack actuators)

  • 임장환;김재환
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.649-654
    • /
    • 2003
  • This paper is focused on the research of the ultra precision linear motor by using piezo stack actuators. The development of linear motor which can be controlled nano or micro scale is necessary for the precision manufacturing. Self-moving-cell principle is used for the design of linear motor Self-moving-cell linear motor is consisted of three cell structures, and each cell has two shells and one piezo-stack actuator. Each cell can do clamping and moving by two shell structures. The shell structure deformation by piezo stack actuator can move the linear motor by losing the clamping between the shall and guideway. This paper presents the design, manufacturing and test of the motor.

  • PDF

Dynamic buckling response of temperature-dependent functionally graded-carbon nanotubes-reinforced sandwich microplates considering structural damping

  • Shokravi, Maryam;Jalili, Nader
    • Smart Structures and Systems
    • /
    • 제20권5호
    • /
    • pp.583-593
    • /
    • 2017
  • This research deals with the nonlocal temperature-dependent dynamic buckling analysis of embedded sandwich micro plates reinforced by functionally graded carbon nanotubes (FG-CNTs). The material properties of structure are assumed viscoelastic based on Kelvin-Voigt model. The effective material properties of structure are considered based on mixture rule. The elastic medium is simulated by orthotropic visco-Pasternak medium. The motion equations are derived applying Sinusoidal shear deformation theory (SSDT) in which the size effects are considered using Eringen's nonlocal theory. The differential quadrature (DQ) method in conjunction with the Bolotin's methods is applied for calculating resonance frequency and dynamic instability region (DIR) of structure. The effects of different parameters such as volume percent of CNTs, distribution type of CNTs, temperature, nonlocal parameter and structural damping on the dynamic instability of visco-system are shown. The results are compared with other published works in the literature. Results indicate that the CNTs have an important role in dynamic stability of structure and FGX distribution type is the better choice.

고분해능 원자 현미경 스캐닝 무아레 기법을 이용한 미소 영역의 변형량 측정 (Measurement of Deformations in Micro-Area Using High Resolution AFM Scanning Moiré Technique)

  • 박진형;이순복
    • 대한기계학회논문집A
    • /
    • 제31권6호
    • /
    • pp.659-664
    • /
    • 2007
  • $Moire\'{e}$ interferometry is a useful technique to assess the reliability of electronic package because $Moire\'{e}$ interferometry can measure the whole-field and real-time deformations. The shear strain of a small crack site is important to the reliability assessment of electronic package. The optical limitation of $Moire\'{e}$ interferometry makes ambiguous the shear strain of a small area. An atomic force microscope (AFM) is used to measure the profile of a micro site. High resolution of AFM can apply to the $Moire\'{e}$ technique. AFM $Moire\'{e}$ technique is useful to measure the shear strain of a small area. In this research, the method to accurately measure the deformation of a small area by using AFM $Moire\'{e}$ is proposed. A phase-shifting method is applied to improve the resolution of AFM $Moire\'{e}$.

PC소재의 선형 패턴 제작에 관한 연구 (A study on Linear Pattern Fabrication of Plate-type PC)

  • 정유나;이은경;강충길
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2008년도 춘계학술대회 논문집
    • /
    • pp.277-280
    • /
    • 2008
  • Recently, a demand of nano/micro patterned polymer for display or biochip has been rising. Then many studies have been carried out. Nano/micro-embossing is a deformation process where the workpiece materials is heated to permit easier material flow and then forced over a planar patterned tool. In this work, the hot-emboss process is performed with different forming conditions; forming temperature, load, press hold time, to get the proper condition for linear pattern fabrication on plated-type polymers (PC). Replicated pattern depth increases in proportion to the forming temperature, load and time. Reduction of the workpiece thickness increases according to press hold time. In process of time, reduction ratio of workpiece thickness decreases because of surface area increment of the workpiece and pressure decline on it.

  • PDF

Influence of variable thermal conductivity on waves propagating through thermo-elastic medium

  • Abo-Dahab, Sayed M.;Jahangir, Adnan;Dar, Adiya
    • Structural Engineering and Mechanics
    • /
    • 제82권4호
    • /
    • pp.459-467
    • /
    • 2022
  • We investigated the influence of variable thermal conductivity on waves propagating through the elastic medium. Infinitesimal deformation results in generation of thermal signal, and is analyzed by using dual phase lag heat (DPL) conduction model. The medium considered is homogenous, isotropic and bounded by thermal shock. The elastic waves propagating through the medium are considered to be harmonic in nature, and expressions for the physical variables are obtained accordingly. Analytically, we obtained the expressions for displacement components, temperature, micro-temperature component and stresses. The theoretical results obtained are computed graphically for the particular medium by using MATLAB.

줄-톰슨 마이크로 냉각기용 소형 금속 벨로우즈의 구조적 특성에 관한 연구 (A Study on the Structural Characteristics of Miniature Metal Bellows in Joule-Thomson Micro-Cryocooler)

  • 이승하;이태원
    • 한국정밀공학회지
    • /
    • 제25권9호
    • /
    • pp.95-102
    • /
    • 2008
  • A miniature metal bellows is used to minimize the excessive flow of the cryogenic gas in Joule-Thomson micro cryocooler. It is made of metal alloy and its geometry is axisymmetric. The bellows is filled with high pressure gas. It contracts or expands in the axial direction for a wide change of temperature, because the pressure and volume inside the bellows must be satisfied with state equation of the gas. Therefore, in order to design the bellows in Joule-Thomson micro-cryocooler, it is important to evaluate deformation of the bellows under internal pressure exactly. Considering geometric nonlinearity, deformations analysis of the bellows were obtained by a commercial finite element code ANSYS, The bellows was modeled by 3-node axisymmetric shell elements with reduced integration. Experiments were also performed to prove the validity of proposed numerical analysis. The results by numerical analysis and experiments were shown in good agreements.

22Cr 마이크로 듀플렉스 스테인리스강의 변형유기마르텐사이트에 미치는 Ni과 Mn의 영향 (Effect of Ni and Mn on Strain Induced Martensite Behavior of 22Cr Micro-Duplex Stainless steel)

  • 박준영;김기엽;안용식
    • 동력기계공학회지
    • /
    • 제17권6호
    • /
    • pp.122-129
    • /
    • 2013
  • The microstructure and deformation behavior in 22Cr-0.2N micro-duplex stainless steels with various Ni and Mn contents were compared using by OM, TEM, and XRD. The 22Cr-0.2N duplex stainless steel plates were fabricated and hot rolled, followed by annealing treatment at the temperature range of $1,000-1,100^{\circ}C$. All the samples showed the common strain hardening behaviour during the tensile test at a room temperature. The steels tested at the temperatures of $-30^{\circ}C$ or $-50^{\circ}C$ showed a distinct inflection point in the stress-strain curves, which should be resulted from the formation of strain-induced martensite(SIM) of austenite phase. This was confirmed by TEM observations. The onset strain of a inflection point in a stress-strain curve should be depended up the value of $M_d30$. With the decrease of the tensile test temperature, the inflection point appeared earlier, and the strength and fracture strain were higher. The tensile behaviour was discussed from the point of austenite stability of the micro-duplex stainless steels with the different Ni and Mn content.

열풍동형 폴리실리콘 마이크로 액츄에이터의 제작 및 특성 분석 (Fabrication of thermally driven polysilicon micro actuator and its characterization)

  • 이종현
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1996년도 춘계학술대회 논문집
    • /
    • pp.146-150
    • /
    • 1996
  • A thermal micro actualtor has been fabricated using surface micromachining techniques. It consists of doped ploysilicon as a moving part and TEOS(Tetra Ethyl Ortho Silicate) as a sacrificial layer. The polysilicon was annealed for the reduction of residual stress which is the main cause to its deformation such as bending and buckling. And the newly developed HF VPE(vapor phase etching)process was also used as an effective release method for the elimination of sacrificaial layer. With noliquid involved during any of the steps for relasing, unlike other reported relase techniques, the HF VPE pocess has produced polysilicon microstructures with virtually no process-induced stiction problem. The actuation is incured by the thermal expasion due to current flow in active polysilicon cantilever, which motion is amplified bylever mechanism. The thickness of pllysilicon is 2 .mu. m and the length of active and passive polysilicon cantilever are 500 .mu. m, respectively. The moving distance of polysilicon actuator was experimentally conformed as large as 21 .mu. m at the input voltage level of 10 V and 50Hz square wave. These micro actuator technology can be utilized for the fabrication of MEMS (microlectromechanical system) such as microrelay, which requires large displacement or contact force but relatively slow response.

  • PDF

유한요소 모델 변수의 역 추정법을 이용한 생체의 물성 규명 (Biomechanical Characterization with Inverse FE Model Parameter Estimation: Macro and Micro Applications)

  • 안범모;김영진;신현정;김정
    • 대한기계학회논문집A
    • /
    • 제33권11호
    • /
    • pp.1202-1208
    • /
    • 2009
  • An inverse finite element (FE) model parameter estimation algorithm can be used to characterize mechanical properties of biological tissues. Using this algorithm, we can consider the influence of material nonlinearity, contact mechanics, complex boundary conditions, and geometrical constraints in the modeling. In this study, biomechanical experiments on macro and micro samples are conducted and characterized with the developed algorithm. Macro scale experiments were performed to measure the force response of porcine livers against mechanical loadings using one-dimensional indentation device. The force response of the human liver cancer cells was also measured by the atomic force microscope (AFM). The mechanical behavior of porcine livers (macro) and human liver cancer cells (micro) were characterized with the algorithm via hyperelastic and linear viscoelastic models. The developed models are suitable for computing accurate reaction force on tools and deformation of biomechanical tissues.

소재 크기효과를 고려한 미세가공공정 유한요소해석 (Finite Element Analysis for Micro-Forming Process Considering the Size Effect of Materials)

  • 변상민;이영석
    • 소성∙가공
    • /
    • 제15권8호
    • /
    • pp.544-549
    • /
    • 2006
  • In this work, we have employed the strain gradient plasticity theory to investigate the effect of material size on the deformation behavior in metal forming process. Flow stress is expressed in terms of strain, strain gradient (spatial derivative of strain) and intrinsic material length. The least square method coupled with strain gradient plasticity was used to calculate the components of strain gradient at each element of material. For demonstrating the size effect, the proposed approach has been applied to plane compression process and micro rolling process. Results show when the characteristic length of the material comes to the intrinsic material length, the effect of strain gradient is noteworthy. For the microcompression, the additional work hardening at higher strain gradient regions results in uniform distribution of strain. In the case of micro-rolling, the strain gradient is remarkable at the exit section where the actual reduction of the rolling finishes and subsequently strong work hardening take places at the section. This results in a considerable increase in rolling force. Rolling force with the strain gradient plasticity considered in analysis increases by 20% compared to that with conventional plasticity theory.