• Title/Summary/Keyword: Micro-current electrical therapy

Search Result 11, Processing Time 0.026 seconds

The Effect of Micro-current Electrical Therapy on Muscle Atrophy and Delayed Wound Healing Process Induced Rat Caused by Traumatic Peripheral Nerve Injury (외상성 말초신경 손상으로 인한 창상 치유 지연 및 근위축이 유발된 소동물에서의 미세전류 자극 효능 평가)

  • Lee, Hana;Kim, Seohyun;Hwang, Donghyun;Yoo, Lee;Yu, Jihee;Kim, Minju;Cho, Seungkwan;Kim, Han Sung
    • Journal of Biomedical Engineering Research
    • /
    • v.39 no.1
    • /
    • pp.1-9
    • /
    • 2018
  • This study was carried out to evaluate the effect of micro-current therapy on muscle atrophy and delayed wound healing process caused by traumatic peripheral nerve injury. For this, twenty-five 5-week-old Sprague Dawley rat were used and assigned to five groups including the normal group (NOR, n=5), the wound group (WD, n=5), the wounded and treated with micro-current electrical therapy group (WD+MET, n=5), the sciatic nerve denervated and wounded group (WD+DN, n=5), and the sciatic nerve denervated, wounded and treated with micro-current electrical therapy group (WD+DN+MET, n=5). In order to assess the changes in length of incisional wound for 12 days and the muscle volume for 2 weeks, the ImageJ analysis of macroscopic analysis and micro-CT data were obtained and analyzed. As a result, significant delay in the process in wound healing were observed and micro-current therapy suppress the postponement of healing process. Furthermore, there were significant changes in muscle volume between electrically treated group and non-treated group. These result shows that electrical stimulation may improve the delayed healing process and muscle atrophy at once.

The Effects of Microcurrent Treatment and Ultrasound Treatment on the Pain Relief and Functional Recovery after Total Knee Replacement (미세전류치료와 초음파치료가 슬관절전치환술 후 통증경감과 기능회복에 미치는 영향)

  • Cho, Woon-Su;Kim, Yong-Nam;Kim, Yong-Seong;Hwang, Tae-Yeon;Jin, Hee-Kyung
    • The Journal of Korean Physical Therapy
    • /
    • v.24 no.2
    • /
    • pp.118-126
    • /
    • 2012
  • Purpose: The purpose of this study was to investigate pain relief and functional recovery after total knee replacement. Methods: The treatment was performed by dividing individuals into a control group ($n_1=5$), ultrasound treatment group ($n_2=5$), and micro-current treatment group ($n_3=5$). The control group applied the hot pack for 15 minutes, Transcutaneous Electrical Nerve Stimulation (TENS) for 15 minutes, and Continuous Passive Movement (CPM) for 40 minutes. The ultrasound therapy group applied the frequency of 1 MHz, intensity of 1.0 $W/cm^2$ for five minutes following the same treatment as the control group. The micro-current therapy group applied the intensity of 25 ${\mu}A$, and pulsation frequency 5 pps for 15 minutes following the same treatment as the control group. After treatment, Visual Analogue Scale (VAS), Korean Western Ontario and McMaster Universities Arthritis Index (K-WOMAC), Berg Balance Scale (BBS), Range of Movement (ROM) and wound length was measured. Results: VAS showed significant effect in the control group and micro-current therapy group during the treatment period. According to the treatment of K-WOMACK, BBS, ROM, and Healing wounds showed main effects between groups. Conclusion: According to the results of this study, data showed improvement of pain relief, wound healing effects, and range of motion recovery. Thus, these selected treatments were effective after total knee replacement. In other words, electrical treatment continues to influence pain relief and functional recovery after total knee replacement.

Efficacy of electrical neuromuscular stimulation in the treatment of chronic periodontitis

  • Puhar, Ivan;Kapudija, Amalija;Kasaj, Adrian;Willershausen, Brita;Zafiropoulos, Gregory-George;Bosnjak, Andrija;Plancak, Darije
    • Journal of Periodontal and Implant Science
    • /
    • v.41 no.3
    • /
    • pp.117-122
    • /
    • 2011
  • Purpose: The purpose of the present randomized controlled clinical study was to evaluate the short-term outcomes of micro-current electrical neuromuscular stimulation (MENS) as an adjunct method to nonsurgical periodontal therapy. Methods: Twenty patients with moderate to severe chronic periodontitis were recruited into the study and randomly treated with either nonsurgical periodontal therapy followed by 5 MENS treatments with a micro current device or by nonsurgical periodontal therapy alone. Periodontal parameters were measured at baseline and 6 weeks following therapy, and included the plaque index, bleeding on probing, probing depth, and clinical attachment level (CAL). Results: All measured values were reduced at the time of re-evaluation. The amount of inflammation was significantly reduced in both the test (P=0.002) and control group (P=0.015). The test group demonstrated a significant CAL gain at 6 weeks following therapy, including non-molar (P=0.009) and molar teeth (P=0.028). In comparison with the control group, the test group showed statistically significant differences in the CAL on both molar (P=0.027) and non-molar teeth (P=0.031). Conclusions: In conclusion, the short-term results of the study indicate that MENS could be a suitable adjunctive method in the treatment of chronic periodontitis.

Development of 4ch Light Irradiator for Medical Therapy (의료용 4ch 광 조사 발진기 개발)

  • Cheon, Min-Woo;Kim, Seong-Hwan;Mun, Seong-Pyo;Park, Yong-Pil;Kim, Tae-Gon;Park, No-Bong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.480-480
    • /
    • 2007
  • This paper performed the basic study for developing the light therapy equipment for medical treatment. We developed the equipment for medical therapy using a high brightness LED. This equipment was fabricated using a micro-controller and a high brightness LED, and designed to enable us to control light irradiation time, intensity, frequency and so on. Especially, to control the light irradiation frequency, and to control the change of output value, TLC5941 was used. Control stage is divided into 4 step by program. Consequently, the current value could be controlled by the change of level in Continue Wave(CW) and the output of a high brightness LED could be controlled, stage by stage.

  • PDF

The Effects of Microcurrent Stimulation on Recovery of Function and Pain in Chronic Low Back Pain (만성요통 환자에 대한 미세전류자극 치료가 통증 및 기능 회복에 미치는 영향)

  • Oh, Hyen-Ju;Kim, Jong-Youl;Park, Rae-Joon
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.3 no.1
    • /
    • pp.47-56
    • /
    • 2008
  • Purpose : This study observed the recovery of function and pain on the eletrostimulation therapy(transcutaneous electrical nerve stimulation(TENS) and micro current therapy(MT)). Methods : Subjects were assigned randomly either experimental group(n=17) who were taken TENS or the control group(n=20) who were taken MT. Also subjects were assessed for pain(Visual Analog Scale; VAS) and function(Oswestry LBP disability index). Results : The VAS has a statistically significant difference with each groups(p<.05), but there was no statistically significant difference with intergroup during treatment period(p>.05). The Oswestry LBP disability index has a statistically significant difference with each groups(p<.05), also there was a statistically significant difference with intergroup during treatment period(p<.05). Conclusion : The efficancy of microcurrent therapy used in this study should be futher investigated in a long period study and objective study outcomes.

  • PDF

4-channel Light Medical Therapy Apparatus for External Injury Cure (체외 상처 치유를 위한 4-채널 광 치료기)

  • Cheon, Min-Woo;Kim, Seong-Hwan;So, Keum-Young;Moon, Young-Lae;Mun, Seong-Pyo;Park, Yong-Pil;Lee, Ho-Sik;Kim, Tae-Gon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.8
    • /
    • pp.731-735
    • /
    • 2007
  • We developed the 4channel Light Medical Therapy Apparatus for External Injury Cure using a high brightness LED. This equipment was fabricated using a micro-controller and a high brightness LED, and designed to enable us to control light irradiation time, intensity, frequency and so on, Especially, to control the light irradiation frequency, FPGA was used, and to control the change of output value, TLC5941 was used. Control stage is divided into 4 levels by program. Consequently, the current value could be controlled by the change of level in Continue Wave(CW) and the output of a high brightness LED could be controlled stage by stage. Compared with one LED irradiation, several LEDs irradiation could increase optical power.

Effects of Microcurrent Delayed Onset Muscle Soreness on Creatine Kinase (지연성 근육통에 대한 미세전류자극치료가 통증과 CK에 미치는 영향)

  • Cho, Namjeong;Song, SeongHyeok
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.2 no.3
    • /
    • pp.31-37
    • /
    • 2014
  • Purpose : Delayed onset muscle soreness(DOMS) is a common problem that can interfere with rehabilitation as well as activities of daily living. The purpose of this study was to compare the effect of both trascutaneous electrical nerve stimulation(TENS) Micro current(MC) and only normal Therapy on Delyed Onset Muscle Soreness(DOMS). Method : The Methods ten untrained and male volunteer subjects were randomly assigned to one of two treatment groups: 1) a group that received TENS (60Hz) MC($60{\mu}A$, 3pps) a control group that received no MC treatment. Subjects performed repeated eccentric exercise of the non-dominant forearm flexor muscle with submaximal intensity by the simply designed eccentric exercise devices. Treatments were applied after 24hours and 48hours. Subjects attended on two consecutive days for treatment and measurement of paining(visual analogue scale: VAS) and CK(Creatine kinase) on a daily basis. Measurements were taken after treatment. Results : 1) There were no significant differences between TENS and MENS by two-way repeated ANOVA. The Results that t-test for VAS revealed significant differences within TENS group. 3) The t-test for VAS, and Creatine Kinase of time revealed significant differences within MC group. Conclusion : These findings suggest that both TENS and MENS had effect on DOMS.

The Effect of Microcurrent Electrical Stimulation on Muscle Atrophy Suppression in a Sciatic Nerve Injured Rat Model; Comparative Study by Current Intensity (좌골신경손상 쥐 모델을 이용한 미세전류 자극의 근위축 억제 효과 확인 및 자극 세기 별 비교)

  • Hwang, Donghyun;Kim, Seohyun;Lee, Hana;Jang, Seungjun;Kim, Sebin;kim, Tackjoong;Choi, Sooim;Kwak, Hoyoung;Kim, Han Sung
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.4
    • /
    • pp.175-182
    • /
    • 2017
  • Microcurrent electrical stimulation(MES) has been used to accelerate recovery of atrophied skeletal muscle. However, convincing stimulation parameters for suppressing muscle atrophy due to injured sciatic nerve remains unclear. The objective of this study was to investigate the effective intensity of MES on restraining muscle atrophy with rat model underwent sciatic nerve injury(SNI). Twenty-5-week-old Sprague Dawley male rats were equally assigned to five groups : Control group(Control, CON, n = 4), Denervation group(Denervation, D, n = 4), Denervation with MES of $22{\mu}A$ group(Denervation + $22{\mu}A$, D+22, n = 4), Denervation with MES of $100{\mu}A$ group (Denervation + $100{\mu}A$, D+100 n = 4), Denervation with MES of $400{\mu}A$ group(Denervation + $400{\mu}A$, D+400, n = 4). To induce muscle atrophy, all rats in the D, D+22, D+100, and D+400 groups, were subjected to sciatic nerve injury on their right hindlimb and allowed to have 1 week of resting period. Following this period, rats underwent daily MES(60 min/ a day, 5times/1week) for 4 weeks. After that, we investigate morphological changes in muscle volume by using in vivo micro-computed tomography at week 0, 1, 3 and 5. After 5 weeks, the muscle volume had the highest value in D+400 group, and also noticeably increased in D+100 group compared to it in D group. The results of this study imply that MES with current intensities between $100-400{\mu}A$ can suppress muscle atrophy effectively.

Development of LED Irradiation System for Cell Proliferation (세포증식을 위한 LED 조사 시스템 개발)

  • Cheon, Min-Woo;Park, Yong-Pil;Lee, Ho-Shik;Kim, Tae-Gon;Kim, Young-Pyo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.05a
    • /
    • pp.581-582
    • /
    • 2010
  • This paper performed the basic study for developing the Photodynamic Therapy Equipment for medical treatment. We developed the equipment palpating cell proliferation using a high brightness LED. This equipment was fabricated using a micro-controller and a high brightness LED, and designed to enable us to control light irradiation time, intensity, frequency and so on. Especially, to control the light irradiation frequency, FPGA was used, and to control the change of output value, TLC5941 was used. Control stage is divided into 30 step by program. Consequently, the current value could be controlled by the change of level in Continue Wave(CW) and Pulse Width Modulation(PWM), and the output of a high brightness LED could be controlled stage by stage.

  • PDF

Characteristics of Low-level Light Source for Animal Cell Proliferation (동물 세포 증식을 위한 저출력 광 소스의 특성)

  • Cheon, Min-Woo;Kim, Seong-Hwan;Song, Chang-Hun;Mun, Seong-Pyo;Kim, Tae-Gon;Park, Yong-Pil;Kim, Dae-Young;Kim, Young-Su
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.1
    • /
    • pp.92-97
    • /
    • 2007
  • This paper performed the basic study for developing the Photodynamic Therapy Equipment for medical treatment. We developed the equipment palpating cell proliferation using a high brightness LED. This equipment was fabricated using a micro-controller and a high brightness LED, and designed to enable us to control light irradiation time, intensity, frequency and so on. Especially, to control the light irradiation frequency, FPGA was used, and to control the change of output value, TLC5941 was used. Control stage is divided into 30 levels by program. Consequently, the current value could be controlled by the change of level in Continue Wave(CW) and Pulse Width Modulation(PWM), and the output of a high brightness LED could be controlled stage by stage. And then, each experiment was performed to irradiation group and non-irradiation group for both Rat bone marrow and Rat tissue cells. MTT assay method was chosen to verify the cell increase of two groups and the effect of irradiation on cell proliferation was examined by measuring 590 nm transmittance of ELISA reader. As a result, the cell increase of Rat bone marrow and tissue cells was verified in irradiation group as compared to non-irradiation group. The fact that specific wavelength irradiation has an effect on cell vitality and proliferation is known through this study.