• 제목/요약/키워드: Micro-current electrical therapy

검색결과 11건 처리시간 0.025초

외상성 말초신경 손상으로 인한 창상 치유 지연 및 근위축이 유발된 소동물에서의 미세전류 자극 효능 평가 (The Effect of Micro-current Electrical Therapy on Muscle Atrophy and Delayed Wound Healing Process Induced Rat Caused by Traumatic Peripheral Nerve Injury)

  • 이한아;김서현;황동현;유리;유지희;김민주;조승관;김한성
    • 대한의용생체공학회:의공학회지
    • /
    • 제39권1호
    • /
    • pp.1-9
    • /
    • 2018
  • This study was carried out to evaluate the effect of micro-current therapy on muscle atrophy and delayed wound healing process caused by traumatic peripheral nerve injury. For this, twenty-five 5-week-old Sprague Dawley rat were used and assigned to five groups including the normal group (NOR, n=5), the wound group (WD, n=5), the wounded and treated with micro-current electrical therapy group (WD+MET, n=5), the sciatic nerve denervated and wounded group (WD+DN, n=5), and the sciatic nerve denervated, wounded and treated with micro-current electrical therapy group (WD+DN+MET, n=5). In order to assess the changes in length of incisional wound for 12 days and the muscle volume for 2 weeks, the ImageJ analysis of macroscopic analysis and micro-CT data were obtained and analyzed. As a result, significant delay in the process in wound healing were observed and micro-current therapy suppress the postponement of healing process. Furthermore, there were significant changes in muscle volume between electrically treated group and non-treated group. These result shows that electrical stimulation may improve the delayed healing process and muscle atrophy at once.

미세전류치료와 초음파치료가 슬관절전치환술 후 통증경감과 기능회복에 미치는 영향 (The Effects of Microcurrent Treatment and Ultrasound Treatment on the Pain Relief and Functional Recovery after Total Knee Replacement)

  • 조운수;김용남;김용성;황태연;진희경
    • The Journal of Korean Physical Therapy
    • /
    • 제24권2호
    • /
    • pp.118-126
    • /
    • 2012
  • Purpose: The purpose of this study was to investigate pain relief and functional recovery after total knee replacement. Methods: The treatment was performed by dividing individuals into a control group ($n_1=5$), ultrasound treatment group ($n_2=5$), and micro-current treatment group ($n_3=5$). The control group applied the hot pack for 15 minutes, Transcutaneous Electrical Nerve Stimulation (TENS) for 15 minutes, and Continuous Passive Movement (CPM) for 40 minutes. The ultrasound therapy group applied the frequency of 1 MHz, intensity of 1.0 $W/cm^2$ for five minutes following the same treatment as the control group. The micro-current therapy group applied the intensity of 25 ${\mu}A$, and pulsation frequency 5 pps for 15 minutes following the same treatment as the control group. After treatment, Visual Analogue Scale (VAS), Korean Western Ontario and McMaster Universities Arthritis Index (K-WOMAC), Berg Balance Scale (BBS), Range of Movement (ROM) and wound length was measured. Results: VAS showed significant effect in the control group and micro-current therapy group during the treatment period. According to the treatment of K-WOMACK, BBS, ROM, and Healing wounds showed main effects between groups. Conclusion: According to the results of this study, data showed improvement of pain relief, wound healing effects, and range of motion recovery. Thus, these selected treatments were effective after total knee replacement. In other words, electrical treatment continues to influence pain relief and functional recovery after total knee replacement.

Efficacy of electrical neuromuscular stimulation in the treatment of chronic periodontitis

  • Puhar, Ivan;Kapudija, Amalija;Kasaj, Adrian;Willershausen, Brita;Zafiropoulos, Gregory-George;Bosnjak, Andrija;Plancak, Darije
    • Journal of Periodontal and Implant Science
    • /
    • 제41권3호
    • /
    • pp.117-122
    • /
    • 2011
  • Purpose: The purpose of the present randomized controlled clinical study was to evaluate the short-term outcomes of micro-current electrical neuromuscular stimulation (MENS) as an adjunct method to nonsurgical periodontal therapy. Methods: Twenty patients with moderate to severe chronic periodontitis were recruited into the study and randomly treated with either nonsurgical periodontal therapy followed by 5 MENS treatments with a micro current device or by nonsurgical periodontal therapy alone. Periodontal parameters were measured at baseline and 6 weeks following therapy, and included the plaque index, bleeding on probing, probing depth, and clinical attachment level (CAL). Results: All measured values were reduced at the time of re-evaluation. The amount of inflammation was significantly reduced in both the test (P=0.002) and control group (P=0.015). The test group demonstrated a significant CAL gain at 6 weeks following therapy, including non-molar (P=0.009) and molar teeth (P=0.028). In comparison with the control group, the test group showed statistically significant differences in the CAL on both molar (P=0.027) and non-molar teeth (P=0.031). Conclusions: In conclusion, the short-term results of the study indicate that MENS could be a suitable adjunctive method in the treatment of chronic periodontitis.

의료용 4ch 광 조사 발진기 개발 (Development of 4ch Light Irradiator for Medical Therapy)

  • 천민우;김성환;문성표;박용필;김태곤;박노봉
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.480-480
    • /
    • 2007
  • This paper performed the basic study for developing the light therapy equipment for medical treatment. We developed the equipment for medical therapy using a high brightness LED. This equipment was fabricated using a micro-controller and a high brightness LED, and designed to enable us to control light irradiation time, intensity, frequency and so on. Especially, to control the light irradiation frequency, and to control the change of output value, TLC5941 was used. Control stage is divided into 4 step by program. Consequently, the current value could be controlled by the change of level in Continue Wave(CW) and the output of a high brightness LED could be controlled, stage by stage.

  • PDF

만성요통 환자에 대한 미세전류자극 치료가 통증 및 기능 회복에 미치는 영향 (The Effects of Microcurrent Stimulation on Recovery of Function and Pain in Chronic Low Back Pain)

  • 오현주;김종열;박래준
    • 대한물리의학회지
    • /
    • 제3권1호
    • /
    • pp.47-56
    • /
    • 2008
  • Purpose : This study observed the recovery of function and pain on the eletrostimulation therapy(transcutaneous electrical nerve stimulation(TENS) and micro current therapy(MT)). Methods : Subjects were assigned randomly either experimental group(n=17) who were taken TENS or the control group(n=20) who were taken MT. Also subjects were assessed for pain(Visual Analog Scale; VAS) and function(Oswestry LBP disability index). Results : The VAS has a statistically significant difference with each groups(p<.05), but there was no statistically significant difference with intergroup during treatment period(p>.05). The Oswestry LBP disability index has a statistically significant difference with each groups(p<.05), also there was a statistically significant difference with intergroup during treatment period(p<.05). Conclusion : The efficancy of microcurrent therapy used in this study should be futher investigated in a long period study and objective study outcomes.

  • PDF

체외 상처 치유를 위한 4-채널 광 치료기 (4-channel Light Medical Therapy Apparatus for External Injury Cure)

  • 천민우;김성환;소금영;문영래;문성표;박용필;이호식;김태곤
    • 한국전기전자재료학회논문지
    • /
    • 제20권8호
    • /
    • pp.731-735
    • /
    • 2007
  • We developed the 4channel Light Medical Therapy Apparatus for External Injury Cure using a high brightness LED. This equipment was fabricated using a micro-controller and a high brightness LED, and designed to enable us to control light irradiation time, intensity, frequency and so on, Especially, to control the light irradiation frequency, FPGA was used, and to control the change of output value, TLC5941 was used. Control stage is divided into 4 levels by program. Consequently, the current value could be controlled by the change of level in Continue Wave(CW) and the output of a high brightness LED could be controlled stage by stage. Compared with one LED irradiation, several LEDs irradiation could increase optical power.

지연성 근육통에 대한 미세전류자극치료가 통증과 CK에 미치는 영향 (Effects of Microcurrent Delayed Onset Muscle Soreness on Creatine Kinase)

  • 조남정;송승혁
    • 대한통합의학회지
    • /
    • 제2권3호
    • /
    • pp.31-37
    • /
    • 2014
  • Purpose : Delayed onset muscle soreness(DOMS) is a common problem that can interfere with rehabilitation as well as activities of daily living. The purpose of this study was to compare the effect of both trascutaneous electrical nerve stimulation(TENS) Micro current(MC) and only normal Therapy on Delyed Onset Muscle Soreness(DOMS). Method : The Methods ten untrained and male volunteer subjects were randomly assigned to one of two treatment groups: 1) a group that received TENS (60Hz) MC($60{\mu}A$, 3pps) a control group that received no MC treatment. Subjects performed repeated eccentric exercise of the non-dominant forearm flexor muscle with submaximal intensity by the simply designed eccentric exercise devices. Treatments were applied after 24hours and 48hours. Subjects attended on two consecutive days for treatment and measurement of paining(visual analogue scale: VAS) and CK(Creatine kinase) on a daily basis. Measurements were taken after treatment. Results : 1) There were no significant differences between TENS and MENS by two-way repeated ANOVA. The Results that t-test for VAS revealed significant differences within TENS group. 3) The t-test for VAS, and Creatine Kinase of time revealed significant differences within MC group. Conclusion : These findings suggest that both TENS and MENS had effect on DOMS.

좌골신경손상 쥐 모델을 이용한 미세전류 자극의 근위축 억제 효과 확인 및 자극 세기 별 비교 (The Effect of Microcurrent Electrical Stimulation on Muscle Atrophy Suppression in a Sciatic Nerve Injured Rat Model; Comparative Study by Current Intensity)

  • 황동현;김서현;이한아;장승준;김세빈;김택중;최수임;곽호영;김한성
    • 대한의용생체공학회:의공학회지
    • /
    • 제38권4호
    • /
    • pp.175-182
    • /
    • 2017
  • Microcurrent electrical stimulation(MES) has been used to accelerate recovery of atrophied skeletal muscle. However, convincing stimulation parameters for suppressing muscle atrophy due to injured sciatic nerve remains unclear. The objective of this study was to investigate the effective intensity of MES on restraining muscle atrophy with rat model underwent sciatic nerve injury(SNI). Twenty-5-week-old Sprague Dawley male rats were equally assigned to five groups : Control group(Control, CON, n = 4), Denervation group(Denervation, D, n = 4), Denervation with MES of $22{\mu}A$ group(Denervation + $22{\mu}A$, D+22, n = 4), Denervation with MES of $100{\mu}A$ group (Denervation + $100{\mu}A$, D+100 n = 4), Denervation with MES of $400{\mu}A$ group(Denervation + $400{\mu}A$, D+400, n = 4). To induce muscle atrophy, all rats in the D, D+22, D+100, and D+400 groups, were subjected to sciatic nerve injury on their right hindlimb and allowed to have 1 week of resting period. Following this period, rats underwent daily MES(60 min/ a day, 5times/1week) for 4 weeks. After that, we investigate morphological changes in muscle volume by using in vivo micro-computed tomography at week 0, 1, 3 and 5. After 5 weeks, the muscle volume had the highest value in D+400 group, and also noticeably increased in D+100 group compared to it in D group. The results of this study imply that MES with current intensities between $100-400{\mu}A$ can suppress muscle atrophy effectively.

세포증식을 위한 LED 조사 시스템 개발 (Development of LED Irradiation System for Cell Proliferation)

  • 천민우;박용필;이호식;김태곤;김영표
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2010년도 춘계학술대회
    • /
    • pp.581-582
    • /
    • 2010
  • 광 의료 분야 중 저출력레이저 치료에 사용되는 레이저와 같은 특정 파장을 발생하고 레이저보다 안정적으로 사용이 가능한 고휘도 LED를 조사하여 광 의료 분야에 적용할 수 있는 시스템을 개발하였다. 광조사 시스템은 마이크로 컨트롤러, FPGA, TLC5941 및 고휘도 LED를 이용하여 설계 및 제작하였으며 광조사 시간, 강도, 주기 등 세포 증식에 영향을 칠 수 있는 다양한 변수들의 제어가 가능하도록 하였다. 또한 세포 배양에 사용되는 인큐베이터 내부의 조사가 용이하도록 탈부착이 가능한 모듈화 된 LED를 설계 제작하여 세포 증식에서 발생 가능한 생물학적 변수를 최소화하였다.

  • PDF

동물 세포 증식을 위한 저출력 광 소스의 특성 (Characteristics of Low-level Light Source for Animal Cell Proliferation)

  • 천민우;김성환;송창훈;문성표;김태곤;박용필;김대영;김영수
    • 한국전기전자재료학회논문지
    • /
    • 제20권1호
    • /
    • pp.92-97
    • /
    • 2007
  • This paper performed the basic study for developing the Photodynamic Therapy Equipment for medical treatment. We developed the equipment palpating cell proliferation using a high brightness LED. This equipment was fabricated using a micro-controller and a high brightness LED, and designed to enable us to control light irradiation time, intensity, frequency and so on. Especially, to control the light irradiation frequency, FPGA was used, and to control the change of output value, TLC5941 was used. Control stage is divided into 30 levels by program. Consequently, the current value could be controlled by the change of level in Continue Wave(CW) and Pulse Width Modulation(PWM), and the output of a high brightness LED could be controlled stage by stage. And then, each experiment was performed to irradiation group and non-irradiation group for both Rat bone marrow and Rat tissue cells. MTT assay method was chosen to verify the cell increase of two groups and the effect of irradiation on cell proliferation was examined by measuring 590 nm transmittance of ELISA reader. As a result, the cell increase of Rat bone marrow and tissue cells was verified in irradiation group as compared to non-irradiation group. The fact that specific wavelength irradiation has an effect on cell vitality and proliferation is known through this study.