• 제목/요약/키워드: Micro-current

Search Result 1,171, Processing Time 0.029 seconds

Calibration of micro-ohm shunt used for large current measurement (대전류 측정용 마이크로-옴 분류기의 교정에 관한 연구)

  • Kim, M.K.;Kim, I.K.;Jeong, J.Y.;Kim, I.S.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1862-1864
    • /
    • 2002
  • In this study, micro-ohm shunts with rated ac current of 2, 20, 80kA intended for use as an approved system for ac current measurement were calibrated according to IEC 60060. The scale factor and linearity were determined by comparison with the reference measuring system. Measurements of temperature rise due to the rated current was also investigated to analyze a temperature effect. One of the main goals was the determination of the measurement uncertainty of the shunt. The expanded uncertainty of the scale factor for the complete measuring system was satisfied with the STL(Short-circuit Testing Liaison) guide recognized tentatively.

  • PDF

Manufacturing and Tests of Cryostat for SMES (초전도에너지저장장치용 Cryostat 제작 및 특성시험)

  • Cho, J.W.;Sim, K.D.;Ha, H.S.;Kim, H.J.;Seong, K.C.;Kwon, Y.K.;Ryu, K.S.;Koh, D.Y.;Ryoo, C.S.;Kim, S.R.
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.15-18
    • /
    • 2001
  • SMES consists of superconducting magnet, power converter and cryostat and HTS current lead. The prototype cryostat with HTS current leads and refrigerators was designed and manufactured for micro-SMES. HTS current lead with cryocooler was measured the temperature rise under dc current. The cryostat was evaluated the helium boil-off and mechanical stress during transfer and vibration test. These results will be applied to develope the micro-SMES system.

  • PDF

Fabrication of the pyramid-type silicon tunneling devices for displacement sensor applications (변위센서응용을 위한 피라미드형 실리콘 턴널링소자의 제조)

  • Ma, Tae-Young;Park, Ki-Cheol;Kim, Jeong-Gyoo
    • Journal of Sensor Science and Technology
    • /
    • v.9 no.3
    • /
    • pp.177-181
    • /
    • 2000
  • The tunneling current is exponentially dependent on the separation gap between a pair of conductors. The detection of displacement can be, therefore, carried out by measurment of a variation in the tunneling current. In this experiment, we fabricated pyramid-type silicon tunneling devices in which a tunneling current flow between a micro-tip and $Si_3N_4$ thin film membrane. A MEMS process was used for the fabrication of the tunneling devices. The micro-tips were formed on Si wafers by undercutting a differently oriented square of $SiO_2$ with KOH. The stiffness of the $Si_3N_4$ films were observed and the model for the stiffness calculation, which is useful in predicting the stiffness even when the stiffness ranges beyond the scope of the normal experimental condition, was suggested.

  • PDF

The Effects of Microcurrent Treatment and Ultrasound Treatment on the Pain Relief and Functional Recovery after Total Knee Replacement (미세전류치료와 초음파치료가 슬관절전치환술 후 통증경감과 기능회복에 미치는 영향)

  • Cho, Woon-Su;Kim, Yong-Nam;Kim, Yong-Seong;Hwang, Tae-Yeon;Jin, Hee-Kyung
    • The Journal of Korean Physical Therapy
    • /
    • v.24 no.2
    • /
    • pp.118-126
    • /
    • 2012
  • Purpose: The purpose of this study was to investigate pain relief and functional recovery after total knee replacement. Methods: The treatment was performed by dividing individuals into a control group ($n_1=5$), ultrasound treatment group ($n_2=5$), and micro-current treatment group ($n_3=5$). The control group applied the hot pack for 15 minutes, Transcutaneous Electrical Nerve Stimulation (TENS) for 15 minutes, and Continuous Passive Movement (CPM) for 40 minutes. The ultrasound therapy group applied the frequency of 1 MHz, intensity of 1.0 $W/cm^2$ for five minutes following the same treatment as the control group. The micro-current therapy group applied the intensity of 25 ${\mu}A$, and pulsation frequency 5 pps for 15 minutes following the same treatment as the control group. After treatment, Visual Analogue Scale (VAS), Korean Western Ontario and McMaster Universities Arthritis Index (K-WOMAC), Berg Balance Scale (BBS), Range of Movement (ROM) and wound length was measured. Results: VAS showed significant effect in the control group and micro-current therapy group during the treatment period. According to the treatment of K-WOMACK, BBS, ROM, and Healing wounds showed main effects between groups. Conclusion: According to the results of this study, data showed improvement of pain relief, wound healing effects, and range of motion recovery. Thus, these selected treatments were effective after total knee replacement. In other words, electrical treatment continues to influence pain relief and functional recovery after total knee replacement.

Development and Evaluation of a Portable Micro-Current Stimulator for Acute Lateral Epicondylitis (급성 외측 상과염 치료를 위한 휴대용 미세전류자극기 개발 및 효과 검증)

  • Kwon, Hyeok Chan;Lee, Hyun Ju;Tae, Ki Sik
    • Journal of Biomedical Engineering Research
    • /
    • v.40 no.2
    • /
    • pp.68-74
    • /
    • 2019
  • Lateral epicondylitis is caused by repeated use of the wrist, which causes inflammation and pain in the wrist extensor and tendon of the humerus. Delayed onset muscle soreness (DOMS) caused by repetitive resistance exercise affects the tendons connected in series with the muscle, leading to lateral epicondylitis. Although micro-current stimulation has been suggested as a possible treatment for tendinitis, there are insufficient studies on specific variables such as frequency. In this study, 15 healthy adult males and females developed DOMS in the wrist extensor and tendon in the humerus. The experimental group consisted of a low frequency group applying 20 Hz and a high frequency group applying 100 Hz according to the micro-current frequency. Each subject underwent an experiment for 5 days after DOMS, and the recovery rates were compared by measuring AROM, GPT, MST, PPT, and VAS. As a result, the 20 Hz group showed significant changes in AROM, MST, and VAS compared to the control group on the 4th day, and the recovery rate was also higher than that of the 100 Hz group. On the 5th day, recovery rate of 100 Hz group was higher than 20 Hz in AROM and PPT, and MST showed higher recovery rate than 20 Hz group, but there was no significant difference. These results indicate that microcurrent stimulation is effective for the treatment of delayed myalgia and tendon inflammation and that the 100 Hz group has faster recovery than the 20 Hz group.

The Micro-Current Stimulation Inhibits Adipogenesis by Activating Wnt/β-Catenin Signaling (Wnt/β-catenin 신호 활성화를 통한 미세전류 자극의 지방생성 억제 효과)

  • Hwang, Donghyun;Lee, Hana;Lee, Minjoo;Cho, Seungkwan;Kim, Han Sung
    • Journal of Biomedical Engineering Research
    • /
    • v.41 no.6
    • /
    • pp.235-246
    • /
    • 2020
  • This study aimed to evaluate the inhibitory effect of micro-current stimulation(MCS) on adipogenesis regarding with Wnt/β-catenin pathway using the ob/ob mouse and 3T3-L1 cell line. 6-week old ob/ob male mice were equally assigned to four groups: obese group(ob), obese with MCS groups(50 μA, 200 μA, and 400 μA). 6-week old C57BL/6J male mice were assigned to the control group(CON). We analyzed abdominal adipose tissue volume by using in vivo micro-CT and measured the body weight, feed intake, liver weight and triglycerides in serum. All the MCS groups showed that significantly reduced body weight and triglycerides in serum. In the case of liver weight and abdominal adipose tissue volume, the inhibitory effect of adipogenesis was shown in the 200 μA and 400 μA groups. To elucidate the anti-obesity effect of MCS, β-catenin, C/EBPα and FAS protein expressions were analyzed by western blotting. β-catenin expression was upregulated, C/EBPα and FAS expression were down-regulated in the relatively high-intensity groups(200 μA and 400 μA). Thus, the 200 μA and 400 μA for the intensity of MCS were chosen for cell experiments. In the 3T3-L1 cell line, Wnt/β-catenin pathway including Wnt10b, Wnt3a, β-catenin and Cyclin D1 was activated in all MCS groups. Accordingly, the expression level of C/EBPα was decreased during the differentiation and lipid droplet was significantly reduced in Oil red O staining results. These results suggest that the Wnt/β-catenin signaling might be activated by MCS with current intensities between 200-400 μA and it may lead to anti-obesity effects.

The Cutting Process Monitoring of Micro Machine using Multi Sensor (멀티센서를 이용한 마이크로 절삭 공정 모니터링)

  • Shin, B.C.;Ha, S.J.;Kang, M.H.;Heo, Y.M.;Yoon, G.S.;Cho, M.W.
    • Transactions of Materials Processing
    • /
    • v.18 no.2
    • /
    • pp.144-149
    • /
    • 2009
  • Recently, the monitoring technology of machining process is very important to improve productivity and quality in manufacturing filed. Such monitoring technology has been performed to measurement using vibration signal, acoustic emission signal and tool dynamometer. However, micro machining is limited small-scale parts machining because micro tool is very small and weakness to generate signal in micro machining process. Therefore, this study has efficient sensing technology for real monitoring system in micro machine that is proposed to supplement a disadvantage of single-sensor by multi sensor. From experimental result, it was evaluated tool wear and cutting situation according to repetitive slot cutting condition and changing cutting condition, and it was performed monitoring spindle rpm and condition according to compare acceleration signal with current signal.

The Variation of Electrical Characteristics of PV Module due to Mechanical Stress (기계적 스트레스에 의한 태양전지모듈의 전기적 특성변화)

  • Kong, Ji-Hyun;Ji, Yang-Geun;Kang, Gi-Hwan;Kim, Kyung-Su;Yu, Gwon-Jong;Ahn, Hyung-Kuen;Han, Deuk-Young
    • New & Renewable Energy
    • /
    • v.6 no.1
    • /
    • pp.38-45
    • /
    • 2010
  • Abstract Under the physical stress on photovoltaic (PV) module, it will be warped according to elongation of the front glass and then micro-crack will be occurred in the thermally sealed solar cell. This micro-crack leads to drop of short circuit current of the PV module. This is because of increase of resistance component by micro-crack. Micro-crack at specific solar cell in the module lessens the durability of PV module with reduced output, hot-spot caused by solar cell output mismatch and increased resistance component. This study shows the relation between electrical characteristics and micro- cracks due to mechanical stress on PV module.

Plating Process of Micro-needle for MEMS Probe Card (MEMS Probe Card용 Micro Needle 공정 연구)

  • Han, Myung-Soo;Ahn, Su-Chang;Nam, An-Sik;Kim, Jang-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.152-152
    • /
    • 2008
  • Micro probe with Ni-Co tip was designed. Unit processes for fabricating the micro probe were developed. We are investigated the micro probe tip using by Ni-Co alloy. One-step and three-step needle was fabricated by plating process, CMP, and photolithography process. The plating thickness was varied by current density and time. Futher data will be extract by different process conditions.

  • PDF

Numerical Analysis of the Slip Velocity and Temperature-Jump in Microchannel Using Langmuir Slip Boundary Condition (미소채널내의 Langmuir 미끄럼 경계조건을 통한 미끄럼 속도 및 급격한 온도변화에 관한 수치해석)

  • Kim, Sang-Woo;Kim, Hyun-Goo;Lee, Do-Hyung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.3
    • /
    • pp.164-169
    • /
    • 2009
  • The slip velocity and the temperature jumps for low-speed flow in microchannels are investigated using Langmuir slip boundary condition. This slip boundary condition is suggested to simulate micro flow. The current study analyzes Langmuir slip boundary condition theoretically and it analyzed numerically micro-Couette flow, micro-Poiseuille flow and grooved microchannel flow. First, to prove validity for Langmuir slip condition, an analytical solution for micro-Couette flow is derived from Navier-Stokes equations with Langmuir slip conditions and is compared with DSMC and an analytical solution with Maxwell slip boundary condition. Second, the numerical analysis is performed for micro-Poiseuille flow and grooved microchannel flow. The slip velocity and temperature distribution are compared with results of DSMC or Maxwell slip condition and those are shown in good agreement.