• Title/Summary/Keyword: Micro-current

Search Result 1,171, Processing Time 0.029 seconds

The external and internal morphological standard of original plants and herbal states in 2 kinds of Arisaematis Rhizoma (2종 천남성(天南星)의 외부(外部) 및 내부형태(內部形態)에 대한 연구)

  • Kang Jun-Hyug;Yun Ju-Bong;Ju Young-Sung
    • Herbal Formula Science
    • /
    • v.11 no.2
    • /
    • pp.213-232
    • /
    • 2003
  • Objectives : This study was designed to establish a characteristic discrimination of internal and external morphological standard of original plants and herbal states in Arisaema amurense var. serratum $N_{AKAI}$ and A. amurense $M_{AXIM}.$. Methods : In this studies, the external-internal morphological standards were determined by using stereoscope and butanol series. Results : 1. In the external shape of original plant, Arisaema amurense var. serratum $N_{AKAI}$ has high stem, an oval-elliptic leaflet and a serrate leaf margin. But A. amurense $M_{AXIM}$ has a relatively low stem, an upside oval leaflet and no serrate leaf margin. 2. On the herbs character of original plant, Arisaema amurense var. serratum $N_{AKAI}$ is small in height and diameter, but A. amurense $M_{AXIM}$ is relatively large in height and diameter. 3. On the gathered herbs character of original plant, the section of Arisaema amurense var. serratum $N_{AKAI}$ is brightly white, easily spilt and strong scent. But the section of A. amurense $M_{AXIM}$ is thin yellowish brown, not easily spilt and weak scent. Also the grade of gathered herbs, both can be classified by diameter and external scent. 4. In the current herbs character, Korean and Sichuan Province products are irregullar shape and have no scent, Jilin Province products are regular shape. Also, Guangxi Province products are small size and concave in one side, Hebei Province products are irregular size and shape. 5. In internal shape of original plant, epidermal cell of Arisaema amurense var. serratum is very tight. With the except of micro difference in parenchyma cell of cortex, on the whole there are nearly no differences with A. amurense $M_{AXIM}.$ Also, samely in the internal shape, according to collecting sites, epidermis exhibits a lot layer in curving state and secreting duct is developed and vascular bundle and exists between parenchyma cell of cortex. Conclusion : In the future, additional study is needed to distinguish herb and effect between same genus-degree of relatedness.

  • PDF

An Innovative Solution for the Power Quality Problems in Induction Motor by Using Silica and Alumina Nano Fillers Mixed Enamel for the Coatings of the Windings

  • Mohanadasse, K.;Sharmeela, C.;Selvaraj, D. Edison
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.4
    • /
    • pp.1621-1625
    • /
    • 2015
  • Power quality has always been a concern of power engineers. Certainly an argument can be successfully made that most parts of power engineering have the ultimate objective to improve power quality. AC motors were widely used in industrial and domestic applications. Generally, AC motors were of two types: Induction and Synchronous motors. In motor many parameters like different load cycling, switching, working in hot weather and unbalances creates harmonics which creates major reasons for temperature rise of the motors. Due to high peak value of voltage, harmonics can weaken insulation in cables, windings and capacitors and different electronic components. Higher value of harmonics increase the motor current and decrease the power factor which will reduce the life time of the motor and increase the overall rating of all electrical equipments. Harmonics reduction of all the motors in India will save more power. Coating of windings of the motor with nano fillers will reduce the amount of harmonics in the motor. Based on the previous project works, actions were taken to use the enamel filled with various nano fillers for the coating of the windings of the different AC motors. Ball mill method was used to convert the micro particles of Al2O3, SiO2, TiO2, ZrO2 and ZnO into nano particles. SEM, TEM and XRD were used to augment the particle size of the powder. The synthesized nano powders were mixed with the enamel by using ultrasonic vibrator. Then the enamel mixed with the nano fillers was coated to the windings of the several AC motors. Harmonics were measured in terms of various indices like THD, VHD, CHD and DIN by using Harmonic analyzer. There are many other measures and indices to describe power quality, but none is applicable in all cases and in many instances, these indices may hide more than they show. Sometimes power quality indices were used as a basis of comparison and standardization. The efficiency of the motors was increased by 5 – 10 %. The thermal withstanding capacity of the motor was increased by 5º to 15º C. The harmonics of the motors were reduced by 10 – 50%.

ROC Analysis of Simulated Chest Lesions for Computed Radiography and Digital Radiography at Various Tube Voltages (다양한 관전압에 따른 CR과 DR 모의병변 흉부 영상의 ROC 평가)

  • Cho, Hyo-Min;Kim, Hee-Joung;Lee, Chang-Lae;Jung, Ji-Young;Park, Hye-Suk
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.298-304
    • /
    • 2008
  • Current digital radiographic systems are rapidly growing in clinical applications. The purpose of this study was to evaluate the diagnostic performance of computed radiography (CR) and digital radiography (DR) at different tube voltages in the detection of simulated chest lesions. Patterns of simulated interstitial lung disease, incipient infiltration, and nodules were superimposed over an anthropomorphic chest phantom. A simulated chest phantom radiograph was obtained with CR and DR at different tube voltages (70 kV, 90 kV, and 120 kV). A total of 18,000 observations were analyzed using a receiver operating characteristic (ROC) analysis. The detection of all lesions showed higher $A_z$ values at 70 kV than 120 kV with CR. For the DR, mean $A_z$ values at 70 kV were higher than other tube voltages not all lesions but for micro-nodule interstitial lung disease, linear interstitial lung disease, and incipient infiltration. Based on these results, a clinical study should be performed to judge the use of suitable tube voltage according to the type of detector system and lesions.

  • PDF

Study on Material Flow Analysis of Mercury in Paint (페인트 중 수은의 물질흐름분석 연구)

  • Cho, Yoon A;Jeong, Mi Jeong;Jeon, Tea Wan;Lee, Hee Sung;Kim, Yong Jun;Yeon, Jin Mo;Cho, Na Hyeon;Shin, Sun Kyoung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.4
    • /
    • pp.180-185
    • /
    • 2017
  • For the management of mercury-containing products, the products were selected to do material flow analysis in preference of not having selected in previous studies. Domestically mercury have been added to pigment for prevention of bacterial growth. So, in this study paint containing pigment was selected as a target. 71 samples of paint products collected in 2014 and data of 38 samples of wastes (dust, sludge, paint) analyzed in 2010 were used in material flow analysis. The result shows that mercury was 0~0.25 mg/kg in products and 0.23~0.69 mg/kg in the wastes. In the material flow analysis, the amount of flow in the process of distribution was 10.06 kg/year, but the amount of flow in disposal like a landfill, incineration and recycling was much than distribution as 25.27 kg/year. It was caused by different sampling period between collecting products and data of wastes. Therefore, It could be possible to be affected from regulation by RoHS like decreasing usage of mercury in paint products or eradicated in the industry. Mercury contents in current paint products are very low to affect discharging to the environment.

A Genetic Variant in MiR-146a Modifies Digestive System Cancer Risk: a Meta-analysis

  • Li, Ying-Jun;Zhang, Zhen-Yu;Mao, Ying-Ying;Jin, Ming-Juan;Jing, Fang-Yuan;Ye, Zhen-Hua;Chen, Kun
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.1
    • /
    • pp.145-150
    • /
    • 2014
  • MicroRNAs (miRNAs) negatively regulate gene expression and act as tumor suppressors or oncogenes in oncogenesis. The association between a single nucleotide polymorphism (SNP) in miR-146a rs2910164 and susceptibility to digestive system cancers was inconsistent in previous studies. In this study, we conducted a literature search of PubMed to identify all relevant studies published before August 31, 2013. A total of 21 independent case-control studies were included in this updated meta-analysis with 9,558 cases and 10,614 controls. We found that the miR-146a rs2910164 polymorphism was significantly associated with decreased risk of digestive system cancers in an allele model (OR=0.90, 95%CI 0.87-0.94), homozygote model (OR=0.84, 95%CI 0.77-0.91), dominant model (OR=0.90, 95%CI 0.84-0.96), and recessive model (OR=0.85, 95%CI 0.79-0.91), while in a heterozygous model (OR = 0.99, 95% CI 0.89-1.11) the association showed marginal significance. Subgroup analysis by cancer site revealed decreased risk in colorectal cancer above allele model (OR=0.90, 95%CI 0.83-0.97) and homozygote model (OR=0.85, 95%CI 0.72-1.00). Similarly, decreased cancer risk was observed when compared with allele model (OR=0.87, 95%CI 0.81-0.93) and recessive model (OR=0.81, 95%CI 0.72-0.90) in gastric cancer. When stratified by ethnicity, genotyping methods and quality score, decreased cancer risks were also observed. This current meta-analysis indicated that miR-146a rs2910164 polymorphism may decrease the susceptibility to digestive system cancers, especially in Asian populations.

The Development Trend of a VTOL MAV with a Ducted Propellant (덕티드 추진체를 사용한 수직 이·착륙 초소형 무인 항공기 개발 동향)

  • Kim, JinWan
    • Journal of Aerospace System Engineering
    • /
    • v.14 no.1
    • /
    • pp.68-73
    • /
    • 2020
  • This purpose of this paper was to review the development trend of the VTOL MAVs with a ducted propellant that can fly like the VTOL at intermediate and high speeds, hovering, landing, and lifting off vertically over urban areas, warships, bridges, and mountainous terrains. The MAV differs in flight characteristics from helicopters and fixed wings in many respects. In addition to enhancing thrust, the duct protects personnel from accidental contact with the spinning rotor. The purpose of the U.S. Army FCS and DARPA's OAV program is spurring development of a the VTOL ducted MAV. Today's MAVs are equipped with video/infrared cameras to hover-and-stare at enemies hidden behind forests and hills for approximately one hour surveillance and reconnaissance. Class-I is a VTOL ducted MAV developed in size and weight that individual soldiers can store in their backpacks. Class-II is the development of an organic VTOL ducted fan MAV with twice the operating time and a wider range of flight than Class-I. MAVs will need to develop to perch-and-stare technology for lengthy operation on the current hover-and-stare. The near future OAV's concept is to expand its mission capability and efficiency with a joint operation that automatically lifts-off, lands, refuels, and recharges on the vehicle's landing pad while the manned-unmanned ground vehicle is in operation. A ducted MAV needs the development of highly accurate relative position technology using low cost and small GPS for automatic lift-off and landing on the landing pad. There is also a need to develop a common command and control architecture that enables the cooperative operation of organisms between a VTOL ducted MAV and a manned-unmanned ground vehicle.

Study of the Operation of Actuated signal control Based on Vehicle Queue Length estimated by Deep Learning (딥러닝으로 추정한 차량대기길이 기반의 감응신호 연구)

  • Lee, Yong-Ju;Sim, Min-Gyeong;Kim, Yong-Man;Lee, Sang-Su;Lee, Cheol-Gi
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.17 no.4
    • /
    • pp.54-62
    • /
    • 2018
  • As a part of realization of artificial intelligence signal(AI Signal), this study proposed an actuated signal algorithm based on vehicle queue length that estimates in real time by deep learning. In order to implement the algorithm, we built an API(COM Interface) to control the micro traffic simulator Vissim in the tensorflow that implements the deep learning model. In Vissim, when the link travel time and the traffic volume collected by signal cycle are transferred to the tensorflow, the vehicle queue length is estimated by the deep learning model. The signal time is calculated based on the vehicle queue length, and the simulation is performed by adjusting the signaling inside Vissim. The algorithm developed in this study is analyzed that the vehicle delay is reduced by about 5% compared to the current TOD mode. It is applied to only one intersection in the network and its effect is limited. Future study is proposed to expand the space such as corridor control or network control using this algorithm.

Corrosion behaviors of Cp-Ti and Ti-6Al-4V alloys by TiN coating (TiN 코팅된 Ti 및 Ti-6Al-4V합금의 부식거동)

  • Lee, Soon-Hyun;Jung, Yoong-Hun;Choi, Han-Chul;Ko, Yeong-Mu
    • Journal of Technologic Dentistry
    • /
    • v.30 no.1
    • /
    • pp.25-31
    • /
    • 2008
  • Cp-Ti and Ti-6Al-4V alloys commonly used dental implant materials, particularly for orthopaedic and osteosynthesis because of its suitable mechanical properties and excellent biocompatibility. This alloys have excellent corrosion behavior in the clinical environment. The first factor to decide the success of dental implantation is sufficient osseointegration and high corrosion resistance between on implant fixture and its surrounding bone tissue. In this study, in order to increase corrosion resistance and biocompatibility of Cp-Ti and Ti-6Al-4V alloy that surface of manufactured alloy was coated with TiN by RF-magnetron sputtering method. The electrochemical behavior of TiN coated Cp-Ti and Ti-6Al-4V alloy were investigated using potentiodynamic (EG&G Co, PARSTAT 2273. USA) and potentiostatic test (250mV) in 0.9% NaCl solution at 36.5 $\pm$ 1$^{\circ}C$. These results are as follows : 1. From the microstructure analysis, Cp-Ti showed the acicular structure of $\alpha$-phase and Ti-6Al-4V showed the micro-acicular structure of ${\alpha}+{\beta}$ phase. 2. From the potentiodynamic test, Ecorr value of Cp-Ti and Ti-6Al-4V alloys showed -702.48mV and -319.87mV, respectively. Ti-6Al-4V alloy value was higher than Cp-Ti alloy. 3. From the analysis of TiN and coated layer, TIN coated surface showed columnar structure with 800 nm thickness. 4. The corrosion resistance of TiN coated Cp-Ti and Ti-6Al-4V alloys were higher than those of the non-coated Ti alloys in 0.9% NaCl solution from potentiodynamic test, indicating better protective effect. 5. The passivation current density of TiN coated Cp-Ti and Ti-6Al-4V alloys were smaller than that of the noncoated implant fixture in 0.9% NaCl solution, indicating the good protective effect resulting from more compact and homogeneous layer formation.

  • PDF

Association of Metastasis with Clinicopathological Data in Mexican Patients with Osteosarcoma, Giant Cell Tumor of Bone and Chondrosarcoma

  • Estrada-Villaseor, E;Escamilla-Uribe, R;De la Garza-Montano, P;Dominguez-Rubio, R;Martinez-Lopez, V;Avila-Luna, A;Alfaro-Rodriguez, A;Ruvalcaba-Paredes, EK;Garciadiego-Cazares, D;Bandala, C
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.17
    • /
    • pp.7689-7694
    • /
    • 2015
  • Background: Bone tumors are neoplasias with a high overall mortality; one of the main factors that reduce survival is their high capacity to develop metastases. It has been reported that finding lung metastases at diagnosis of osteosarcoma (OS), chondrosarcoma (CS) and giant cell tumor of bone (GCTb) is quite common. In this study, we inquire the relationship of metastases caused by these tumors with different clinical and pathological aspects, in order to guide medical personnel in the diagnosis and opportune treatment of metastases or micro metastases. Materials and Methods: We collected data of 384 patients with clinical, radiological and histopathological diagnosis of OS, GCTb and CS that attended the National Rehabilitation Institute (INR) during 2006 to 2014. Chi-square and Fisher's exact tests were performed for data analysis. Results: In the three tumor types, the presence of metastases at diagnosis was variable (p=0.0001). Frequency of metastases was 36.7%, 31.7% and 13.2% for OS, CS and GCTb respectively. The average age had no significant difference (p>0.05) in relation to metastases, even so, patients with OS and GCTb and metastases, were older while patients with CS and metastases were younger, in comparison to patients without metastases. Males had a higher frequency of metastases (68.2%, p = 0.09) in contrast to CS and GCTb, in which the metastases was more frequent in women with 51.9% (p = 0.44) and 57.9% (p = 0.56) respectively. Broadly, metastasis was associated with primary tumors located in the femur (44.4%), followed by the tibia (15.6%); metastases was more frequent when primary tumor of GCTb and OS were in the same bones, but were located in the hip (26.3%) for CS. Conclusions: The frequency of metastases in OS, GCTb and CS is high in our population and is determined by different clinicopathological variables related to the kind of tumor. Further studies are needed in order to evaluate metastases subsequent to diagnosis and associations with survival and clinicopathological factors, as well as to determine the sensitivity and specificity of current methods of detection.

A Study on Apparatus of Smart Wearable for Mine Detection (스마트 웨어러블 지뢰탐지 장치 연구)

  • Kim, Chi-Wook;Koo, Kyong-Wan;Cha, Jae-Sang
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.2
    • /
    • pp.263-267
    • /
    • 2015
  • current mine detector can't division the section if it is conducted and it needs too much labor force and time. in addition to, if the user don't move the head of sensor in regular speed or move it too fast, it is hard to detect a mine exactly. according to this, to improve the problem using one direction ultrasonic wave sensing signal, that is made up of human body antenna part, main micro processor unit part, smart glasses part, body equipped LCD monitor part, wireless data transmit part, belt type power supply part, black box type camera, Security Communication headset. the user can equip this at head, body, arm, waist and leg in removable type. so it is able to detect the powder in a 360-degree on(under) the ground whether it is metal or nonmetal and it can express the 2D or 3D film about distance, form and material of the mine. so the battle combats can avoid the mine and move fast. also, through the portable battery and twin self power supply system of the power supply part, combat troops can fight without extra recharge and we can monitoring the battle situation of distant place at the command center server on real-time. and then, it makes able to sharing the information of battle among battle combats one on one. as a result, the purpose of this study is researching a smart wearable mine detector which can establish a smart battle system as if the commander is in the site of the battle.