• 제목/요약/키워드: Micro-controller

검색결과 616건 처리시간 0.028초

물리치료사의 병원 감염관리에 대한 인지도 연구 (Study of Recognition about Hospital Infection Management in Physical Therapists)

  • 송민영;이태식
    • 대한물리치료과학회지
    • /
    • 제9권3호
    • /
    • pp.141-150
    • /
    • 2002
  • Most of physical therapists has thought be exposed themselves to risk of hospital infection but it is reported that have been low concern about infection management. Above like this haven t done systematical education on hospital infection, also physical therapist's information management of infection disease is found very low. It is lack of driving information about disease condition of the patients. Physical therapists has thought their working room may be polluted a lots of micro-organism(%). The control situation of infection waste articles, only 53% responded that the controller has managed very intensive so we can feel to need more intensive It's reported that air culture investigation of physical therapy room has never initiated. To wash the hand, before, after treatment of the patients of physical therapist, is very low frequency. And 73% have responded that the time to wash the hand stays 15-45 second. It is examined that 70% physical therapy room is equipped with washing system, a response of 58% disinfects physical therapy room 1-2times per one month. 36% responded disinfection of treatment modality have done everyday, 25% responded have never done. The location physical therapy room is above one floor - 65%. A response of 57% is ventilation system sufficiency, it is considered that physical therapists needs more efforts on management of hospital infection.

  • PDF

PC 기반 GPS 수신기 하드웨어 모듈 및 펌웨어 개발 (Hardware and Software Implementation of a GPS Receiver Test Bed Running from PC)

  • 윈필롱;윈황휴;이상훈;박옥득;김현수;김한실
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년 학술대회 논문집 정보 및 제어부문
    • /
    • pp.394-396
    • /
    • 2006
  • When developing a new GPS receiver module, the essential problems are evaluation of reliable algorithms, software debugging, and performance comparison between algorithms to find optimal solution. Most GPS receiver modules nowadays use a correlator to track signals from satellites and an MCU (Micro Controller Unit) to control operations of the entire module. The problem of software evaluation from MCU is very difficult, due to limitation of MCU resources and low ability of interfacing with user. Normally, user has to expense special tool kit for a limiting access to MCU but it is also hard to use. This article introduces an implementation of a GPS receiver test bed using correlator GP2021 interfacing with ISA (Industry Standard Architecture) PC bus. This way can give user complete control and visibility into the operation of the receiver, then user can easily debug program and test algorithms. For this article, the least square method is implemented to test the hardware and software performance.

  • PDF

코드를 이용한 초음파 동시구동 시스템 (Simultaneous Driving System of Ultrasonic Sensors Using Codes)

  • 김춘승;최병준;이상룡;이연정
    • 제어로봇시스템학회논문지
    • /
    • 제10권11호
    • /
    • pp.1028-1036
    • /
    • 2004
  • Ultrasonic sensors are widely used in mobile robot applications to recognize external environments by virtue that they are cheap, easy to use, and robust under varying lighting conditions. In most cases, a single ultrasonic sensor is used to measure the distance to an object based on time-of-flight (TOF) information, whereas multiple sensors are used to recognize the shape of an object, such as a comer, plane, or edge. However, the conventional sequential driving technique involves a long measurement time. This problem can be resolved by pulse coding of ultrasonic signals, which allows multi-sensors to be emitted simultaneously and adjacent objects to be distinguished. Accordingly, this paper presents a new simultaneous coded driving system for an ultrasonic sensor array for object recognition in autonomous mobile robots. The proposed system is designed and implemented. A micro-controller unit is implemented using a DSP, Polaroid 6500 ranging modules are modified for firing the coded signals, and a 5-channel coded signal generating board is made using a FPGA. To verify the proposed method, experiments were conducted in an environment with overlapping signals, and the flight distances fur each sensor were obtained from the received overlapping signals using correlations and conversion to a bipolar PCM-NRZ signal.

A Novel Air-cell Mattress Based on Approximate Anthropometric Model for Preventing Pressure Ulcer

  • Moon, In-Hyuk;Kang, Sung-Jae;Kim, Gyu-Seok;Mun, Mu-Seong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1278-1282
    • /
    • 2005
  • Air mattress is now used widely to prevent the pressure ulcer by reducing the localized pressure peaks. In this paper an air-cell mattress and its pressure control method based on an approximate anthropometric model are presented. The air-cell mattress has eighteen cylindrical air cells made of porous material allowing air leakage to contribute in reducing the development of pressure ulcer by lowering the pressure peak, temperature and humidity. To determine an optimal air-cell pressure appropriate for each user, we divide the parts of the body into four sections such as head, trunk, hip, and leg. Then, the pressure of each section is independently calculated from the weight of each part based on the individual body height and weight and the approximate anthropometric model. Air supply system for the air-cell mattress is implemented by using four electronic solenoid valves and an air compressor, and it is driven by a real-time micro-controller. The experimental results with seven subjects shows that the proposed air-cell mattress is effective for the prevention of the pressure ulcer.

  • PDF

실시간 심전도 분석 및 모니터링 시스템 개발 (Development of Realtime ECG Analysis and Monitoring System)

  • 정구영;윤명종;유기호
    • 제어로봇시스템학회논문지
    • /
    • 제15권4호
    • /
    • pp.406-412
    • /
    • 2009
  • ECG is used on purpose to keep good health or monitor cardiac function of aged person as well as on purpose to diagnose the disease of heart patients. The ambulatory ECG monitoring system under guarantee of safety and accuracy is very efficient to prevent the progress of heart disease and sudden death. These systems can detect the temporary change of ECG that is very significant to diagnose heart disease such as myocardial ischemia, arrhyamia and cardiac infarction. In this paper, we describe the ECG signal analysis algorithm and measurement device for ECG monitoring. The authors designed a small-size portable ECG device that consisted of instrumentation amplifier, micro-controller, filter and RF module. The device measures ECG with four electrodes on the body and detects QRS complex and ST level change in realtime. Also it transmits the measured signals to the personal computer. The developed software for ECG analysis in personal computer has the function to detect the feature points and ST level changes.

A Wrist Watch-type Cardiovascular Monitoring System using Concurrent ECG and APW Measurement

  • Lee, Kwonjoon;Song, Kiseok;Roh, Taehwan;Yoo, Hoi-jun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제16권5호
    • /
    • pp.702-712
    • /
    • 2016
  • A wrist watch type wearable cardiovascular monitoring device is proposed for continuous and convenient monitoring of the patient's cardiovascular system. For comprehensive monitoring of the patient's cardiovascular system, the concurrent electrocardiogram (ECG) and arterial pulse wave (APW) sensor front-end are fabricated in $0.18{\mu}m$ CMOS technology. The ECG sensor frontend achieves 84.6-dB CMRR and $2.3-{\mu}Vrms$-input referred noise with $30-{\mu}W$ power consumption. The APW sensor front-end achieves $3.2-V/{\Omega}$ sensitivity with accurate bio-impedance measurement lesser than 1% error, consuming only $984-{\mu}W$. The ECG and APW sensor front-end is combined with power management unit, micro controller unit (MCU), display and Bluetooth transceiver so that concurrently measured ECG and APW can be transmitted into smartphone, showing patient's cardiovascular state in real time. In order to verify operation of the cardiovascular monitoring system, cardiovascular indicator is extracted from the healthy volunteer. As a result, 5.74 m/second-pulse wave velocity (PWV), 79.1 beats/minute-heart rate (HR) and positive slope of b-d peak-accelerated arterial pulse wave (AAPW) are achieved, showing the volunteer's healthy cardiovascular state.

지그비 계층적 라우팅의 성능 향상 기법 (Improvement of Hierarchical Routing in ZigBee Networks)

  • 김태홍;김대영;유성은;성종우;김영수
    • 대한임베디드공학회논문지
    • /
    • 제1권2호
    • /
    • pp.104-112
    • /
    • 2006
  • ZigBee is the emerging industrial standard for ad hoc networks based on IEEE 802.15.4. It is used for low data rate and low power wireless network applications. Expected applications of ZigBee include wireless sensor networks for remote monitoring, home control, and industrial automation. Since one of the most important design goals of ZigBee is to reduce the installation and running costs, the ZigBee stack is embedded in the cheap and small micro-controller unit. The hierarchical routing algorithm is used for ZigBee end devices which have very limited resources. Using the block addressing scheme, end devices can send data to the destination without a routing table. However, hierarchical routing has the problem that the packets follow the tree hierarchy to the destination even if the destination is located nearby. In this paper, we propose a scheme to improve the hierarchical routing algorithm in ZigBee networks by employing the neighbor table that is originally used together with the routing table. We suggest selecting the neighbor node that has the minimum remaining hops to the destination as the next hop node. Simulation result shows that the proposed scheme saves more than 30% of the hop counts compared with the original hierarchical routing.

  • PDF

RF 모듈을 이용한 ECU 자기진단 신호의 원격 계측 (Remote Measurement for ECU Self Diagnostic Signal by RF Module)

  • 정진호;이영춘;윤여흥;권대규;이우열;이성철
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.231-234
    • /
    • 2001
  • OBD-II regulations are already effective in many countries. The California Air Resources Board(CARB) first issued regulations in 1985 for the 1988 model year, known as OBD-I, and required the vehicle's engine management computer to warn the driver by means of a dash-mounted light if a malfunction occurred in either the oxygen sensor, the exhaust gas recirculation(EGR) valve or the evaporative emission system purge solenoid, and to store information on troubles that have no recurrent characteristics. This paper presents two methods of wireless monitoring OBD signal, which is one of the ECU output for self diagnostic measurement. RF module is used to monitor ECU's Self diagnostic signal remotely. Two kinds of measurement systems which are based on micro-controller(80C196KC) for portable detection and PC for sever are considered for receiving the RF signal. Therefore, possibility of real-time monitoring of ECU's self diagnostic signal remotely is verified on this paper.

  • PDF

지능로봇: 지능 에이전트를 기초로 한 접근방법 (Intelligent Robot Design: Intelligent Agent Based Approach)

  • 강진식
    • 한국지능시스템학회논문지
    • /
    • 제14권4호
    • /
    • pp.457-467
    • /
    • 2004
  • 본 논문에서는 로봇을 하나의 에이전트로 보고 로봇에 필요한 기능-환경인지, 지능, 행동-등을 부-에이전트로 하는 로봇 구조를 제안하였다. 각각의 부 에이전트들은 로봇 기능의 기초단위를 구성하는 마이크로 에이전트로 구성된다. 로봇의 제어 구조는 행위기반 반사행동 제어 형태와 행동 선택 에이전트로 구성되며, 행동 선택 에이전트에서의 행동 선택은 행동 우선순위, 수행성능, 강화학습에 의한 학습기능을 부가하였다. 제시된 로봇 구조는 다중 부-에이전트 구조로 각각의 기능에 대하여 지능을 부여하기 쉬우며 다중 로봇 제어를 위한 새로운 접근 방법이다. 제시된 로봇을 장애물을 회피와 chaotic한 탐색을 목표로 하여 모의실험을 수행하였으며 8bit 마이크로 콘트롤러를 이용하여 제작 실험하였다.

MEMS 센서를 활용한 휴대용 음주 측정기 구현 (Implementation of a Portable Breathalyzer Using MEMS Sensor)

  • 주용완;박장식;김현태;유윤식
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2011년도 춘계학술대회
    • /
    • pp.779-781
    • /
    • 2011
  • 음주는 음주 운전, 그리고 건강 이상 등 사회적인 여러 문제들의 가장 중요한 원인 중 하나이다. 음주를 한 개인이 자신이 어느 정도 취한 상태인지를 즉시 알 수 있다면, 음주 운전이나 계속된 음주 스케줄을 자제할 수 있다. 본 논문은 휴대가 가능하도록 MEMS 기반 반도체식 가스센서를 이용한 초소형의 디지털 음주측정기의 구현 방법을 제시한다. 소형 마이크로콘트롤러로써 저전력 소모와 표면 실장이 가능한 ATMEGA48를 기반으로 반도체식 가스센서를 디지털적으로 제어하고 7 세그먼트 LED에 알콜 농도 값을 표출한다.

  • PDF