Generation and Application of Atmospheric Pressure Glow Plasma in Micro Channel Reactor (마이크로 채널 반응기 내 상압 글로우 플라즈마 생성 및 응용)

  • Lee, Dae-Hoon;Park, Hyoun-Hyang;Lee, Jae-Ok;Lee, Seung-S.;Song, Young-Hoon
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1869-1873
    • /
    • 2008
  • In this work, to make it possible to generate glow discharge in atmospheric pressure condition with relatively high and wide electric field, micro channel reactor is proposed. Si DRIE and Cr deposition by Ebeam evaporation is used to make channel and bottom electrode layer. Upper electrode is made from ITO glass to visualize discharge within micro channel. Fabricated reactor is verified by generating uniform glow plasma with N2 / He gases each as working fluid. The range of gas electric field to generate glow plasma is from about 200 V/cm and upper limit is not observed in tested condition of up to 150 kV/cm. This data shows that micro channel plasma reactor is more versatile. Indirect estimation of electron temperature in this reactor can be inferred that the electron temperature within glow discharge in micro reactor lies $0{\sim}2eV$. This research demonstrates that the reactor is appropriate in application that needs to maintain low temperature condition during chemical process.

  • PDF

The Study of the Photocatalytic Degradation for Microreactor (마이크로 반응기를 이용한 광촉매 분해특성 연구)

  • Choi B.C.;Kim H.T.
    • Journal of Energy Engineering
    • /
    • v.14 no.2 s.42
    • /
    • pp.105-111
    • /
    • 2005
  • In this study, the photocatalytic degradtion of D-glucose with the micro channel reactor was performed on the various experimental conditions. To apply the $TiO_2$ coating on the micro channel reactor, $TiO_2$ solution was synthesized by hydrolysis of titanium oxysulfate. The feeding rate was proportional to degradation rate of D-glucose solution over the micro channel reactor. Also, the reaction rate constant and Langmuir adsorption coefficient were calculated under various experimental conditions. And the results of these system photonic efficiencies were calculated. This study aims to understand the photocatalytic degradation characteristics on $TiO_2$ coating in the micro channel reactor experimented by the feed batch reaction system.

Hydrogen Production by Methanol Steam Reforming over Micro-channel Reactor (마이크로 채널 반응기에서 메탄올의 수증기 개질반응을 통한 수소 제조)

  • Lee, Jin-Woo;Jeon, Hye-Jeong;Hong, Sung-Chang
    • Clean Technology
    • /
    • v.15 no.2
    • /
    • pp.130-136
    • /
    • 2009
  • Commercial catalyst (Cu-Zn/$Al_2O_3$, Johnson Matthey Co., 83-3 Catalyst) was applied to the hydrogen production by steam reforming of methanol in the micro-channel reactor (MCR). The steam reforming of methanol was tested over Cu-Zn catalyst at temperatures in the range of 200 and 300$^{\circ}C$, the catalyst size of 0.05${\sim}$2.2 mm, the space velocity of 3,000${\sim}$10,000 $hr^{-1}$ in a fixed bed continuous flow reactor. The conversion of methanol and the yield $H_2$ preferred high temperatures and low space velocities, and had optimal results with the particle size of 0.35 mm. Based on the results from experiments with fixed bed reactor, two types of MCR, boat bed and stacked bed MCRs, were studied. The stacked bed type MCR showed better methanol conversion compared with the boat type one.

Microfluidic Biosensor System for HDL Cholesterol

  • Kim, Joo-Eun;Paek, Se-Hwan
    • 한국생물공학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.717-720
    • /
    • 2003
  • A chromogenic biosensor employing microfluidics on a chip has been developed for the determination of high-density lipoprotein (HDL) cholesterol (HDL-C) in human serum. We have investigated a plain and effective method to immobilize enzymes within the microchip without chemically modifying micro-channel or technically micro-fabricating column reactor and fluid channel network. In assessing risk factors of coronary heart disease, a micro-chip system would minimize requirements of instrument and reagent handling.

  • PDF

Properties of Methane Steam Reforming in Micro Channel Reactor (미세유로 반응기를 이용한 메탄 스팀 개질 반응 특성)

  • Lee, Sung-Wook;Lee, Chun-Boo;Kim, Kwang-Ho;Park, Jin-Woo;Hwang, Kyung-Ran;Park, Jong-Soo;Kim, Sung Hyun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.114.2-114.2
    • /
    • 2010
  • 마이크로 반응기술은 작은 반응기 부피, 높은 열전달, 넓은 반응 면적/부피 및 정확한 반응시간 조절이 가능하기 때문에 화학공정의 고집적화, 반응 선택도의 향상 및 안전도 향상을 꾀할 수 있는 장점이 있다. 이러한 마이크로 반응 기술을 중소형 천연가스 및 국내에서 소규모로 국지적으로 발생하는 메탄의 활용 방안으로서 개발함은 청정 합성유를 제조함으로서 석유 자원의 고갈과 고유가에 대비하여 에너지 자원의 다변화 및 자립을 확보 할 수 있다. 본 연구에서는 마이크로 반응기술을 적용한 미세 유로 반응기(Micro Channel Reactor)를 사용하여 메탄 스팀 개질 반응 특성을 연구하였다. 미세유로 반응기는 내부 홀이 존재하는 plate를 적층함으로 반응기내에 반응가스가 이동할 수 있는 미세유로가 존재하게 하였다. 이러한 미세유로는 반응기의 크기가 작음에도 반응기내에서 반응가스가 충분히 반응할 수 있는 시간과 높은 열전달 효율을 가질 수 있게 한다. 메탄 스팀 개질 반응에 사용된 촉매는 Ni 촉매를 사용하였고, 반응에 필요한 열원으로는 수소 연소에서 발생한 열을 사용하여 반응을 유도하였다. 본 반응기는 외부의 열원을 사용하지 않고, 반응기 내부의 수소 연소에서 발생한 열을 사용함으로 적은 발생 열만으로 메탄 스팀 개질 반응에 필요한 에너지를 얻을 수 있고, 열의 손실이 적다. 또한 메탄 스팀 개질 반응으로 발생한 일부의 수소를 열원으로 이용하여 에너지 사용면에서도 효율적인 반응 공정이다.

  • PDF

Optimization of an extra vessel electromagnetic pump for Lead-Bismuth eutectic coolant circulation in a non-refueling full-life small reactor

  • Kang, Tae Uk;Kwak, Jae Sik;Kim, Hee Reyoung
    • Nuclear Engineering and Technology
    • /
    • v.54 no.10
    • /
    • pp.3919-3927
    • /
    • 2022
  • This study presents an optimal design of the coolant system of a non-refueling full-life small reactor by analyzing the space-integrated geometrical and electromagnetic variables of an extra vessel electromagnetic pump (EVEMP) for the circulation of a lead-bismuth eutectic (LBE) coolant. The EVEMP is an ideal alternative to the thermal-hydraulic system of non-refueling full-life micro reactors as it possesses no internal structures, such as impellors or sealing structures, for the transportation of LBE. Typically, the LBE passes through the annular flow channel of a reactor, is cooled by the heat exchanger, and then circulates back to the EVEMP flow channel. This thermal-hydraulic flow method is similar to natural circulation, which enhances thermal efficiency, while providing a golden time for cooling cores in the event of an emergency. When the forced circulation technology of the EVEMP was applied, the non-refueling full-life micro reactor achieve an output power of 60 MWt, which is higher than that achievable via the natural circulation method (30 MWt). Accordingly, an optimized EVEMP for Micro URANUS with a flow rate of 4196 kg/s and developed pressure of 73 kPa under a working temperature of 250 ℃ was designed.

Fabrication of Micro-reactor by 3D Printing Machine (3D 프린터를 이용한 마이크로 리액터 가공에 관한 연구)

  • Choi, Hae Woon;Yoon, Sung Chul;Ma, Jae Kwon;Bang, Dae Wook
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.23 no.3
    • /
    • pp.218-222
    • /
    • 2014
  • A 3D printer was used to fabricate a micro-TAS system for biomedical applications. A polymeric medical device fabrication based on a 3D printer can be performed at atmospheric conditions. A CAD- and CAM-based system is a flexible method to design medical components, and a 3D printer is a suitable device to perform this task. In this research, a 100-micron-wide fluidic channel was fabricated with a high-aspect ratio. A cross-sectional SEM image confirmed its possible usage in a micro-reactor using 3D printers. CNC-machined samples were compared to 3D printer-fabricated samples, and the advantages and disadvantages were discussed. Based on the SEM images, the surface roughness of the 3D printed reactor was not affected by wet or dry conditions due to its manufacturing principle. An aspect ratio of 5 to 1 was achievable with 100-${\mu}$ m-wide fluid channels. No melting was found, and the shape of channels was straight enough to be used for micro reactors.

Fabrication, Estimation and Trypsin Digestion Experiment of the Thermally Isolated Micro Teactor for Bio-chemical Reaction

  • Sim, Tae-Seok;Kim, Dae-Weon;Kim, Eun-Mi;Joo, Hwang-Soo;Lee, Kook-Nyung;Kim, Byung-Gee;Kim, Yong-Hyup;Kim, Yong-Kweon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.5 no.3
    • /
    • pp.149-158
    • /
    • 2005
  • This paper describes design, fabrication, and application of the silicon based temperature controllable micro reactor. In order to achieve fast temperature variation and low energy consumption, reaction chamber of the micro reactor was thermally isolated by etching the highly conductive silicon around the reaction chamber. Compared with the model not having thermally isolated structure, the thermally isolated micro reactor showed enhanced thermal performances such as fast temperature variation and low energy consumption. The performance enhancements of the micro reactor due to etched holes were verified by thermal experiment and numerical analysis. Regarding to 42 percents reduction of the thermal mass achieved by the etched holes, approximately 4 times faster thermal variation and 5 times smaller energy consumption were acquired. The total size of the fabricated micro reactor was $37{\times}30{\times}1mm^{3}$. Microchannel and reaction chamber were formed on the silicon substrate. The openings of channel and chamber were covered by the glass substrate. The Pt electrodes for heater and sensor are fabricated on the backside of silicon substrate below the reaction chamber. The dimension of channel cross section was $200{\times}100{\mu}m^{2}$. The volume of reaction chamber was $4{\mu}l$. The temperature of the micro reactor was controlled and measured simultaneously with NI DAQ PCI-MIO-16E-l board and LabVIEW program. Finally, the fabricated micro reactor and the temperature control system were applied to the thermal denaturation and the trypsin digestion of protein. BSA(bovine serum albumin) was chosen for the test sample. It was successfully shown that BSA was successfully denatured at $75^{\circ}C$ for 1 min and digested by trypsin at $37^{\circ}C$ for 10 min.

Multi-step Reactions on Microchip Platform Using Nitrocellulose Membrane Reactor

  • Park, Sung-Soo;Joo, Hwang-Soo;Cho, Seung-Il;Kim, Min-Su;Kim, Yong-Kweon;Kim, Byung-Gee
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.8 no.4
    • /
    • pp.257-262
    • /
    • 2003
  • A straightforward and effective method is presented for immobilizing enzymes on a microchip platform without chemically modifying a micro-channel or technically microfabricating a column reactor and fluid channel network. The proposed method consists of three steps: the reconstitution of a nitrocellulose (NC) membrane on a plane substrate without a channel network, enzyme immobilization on the NC membrane, and the assembly of another substrate with a fabricated channel network. As a result, enzymes can be stably and efficiently immobilized on a microchip. To evaluate the proposed method, two kinds of enzymatic reaction are applied: a sequential two-step reaction by one enzyme, alkaline phosphatase, and a coupled reaction by two enzymes, glucose oxidase and peroxidase, for a glucose assay.

Development Study of Mono-Propellant Micro Propulsion Using MEMS Technology

  • Dan, Yoichiro;Kishida, Masahiro;Ikuta, Tatsuya;Takahashi, Koji
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.03a
    • /
    • pp.597-600
    • /
    • 2004
  • Fabrication technique and performance test of catalytic micro propulsion are treated based on MEMS technology. This propulsion is designed to use hydrogen peroxide as liquid mono-propellant for attitude control of pica-satellite. The propellant is fed into the micro reactor channel and decomposed into hot gas yielding controllable thrust by catalyst. In order to increase the efficiency of the reaction that depends on the contact area of propellant and catalyst, porous surface formation on the channel accompanied by platinum particle deposition has been performed using H$_2$PtCl$_{6}$ solution as a precursor. Several thrusters were fabricated in different concentration of H$_2$PtCl$_{6}$ solution to determine the best quantity of Pt particles. For the comparison of the performance of each thruster, the volume of oxygen generated by the decomposition of hydrogen peroxide and the thrust were measured.red.

  • PDF