• Title/Summary/Keyword: Micro-RIA

Search Result 3, Processing Time 0.015 seconds

Development of Microfluidic Radioimmunoassay Platform for High-throughput Analysis with Reduced Radioactive Waste

  • Jin-Hee Kim;So-Young Lee;Seung-Kon Lee
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.8 no.2
    • /
    • pp.95-101
    • /
    • 2022
  • Microfluidic radioimmunoassay (RIA) platform called µ-RIA spends less reagent and shorter reaction time for the analysis compared to the conventional tube-based radioimmunoassay. This study reported the design of µ-RIA chips optimized for the gamma counter which could measure the small samples of radioactive materials automatically. Compared with the previous study, the µ-RIA chips developed in this study were designed to be compatible with conventional RIA test tubes. And, the automatic gamma counter could detect radioactivity from the 125I labeled anti-PSA attached to the chips. Effects of the multi-layer microchannels and two-phase flow in the µ-RIA chips were investigated in this study. The measured radioactivity from the 125I labeled anti-PSA was linearly proportional to the number of stacked chips, representing that the radioactivity in µ-RIA platform could be amplified by designing the chips with multi-layers. In addition, we designed µ-RIA chip to generate liquid-gas plug flow inside the microfluidic channel. The plug flow can promote binding of the biomolecules onto the microfluidic channel surface with recirculation in the liquid phase. The ratio of liquid slug and air slug length was 1 : 1 when the 125I labeled anti-PSA and the air were injected at 1 and 35 µL/min, respectively, exhibiting 1.6 times higher biomolecule attachment compared to the microfluidic chip without the air injection. This experimental result indicated that the biomolecular reaction was improved by generating liquid-gas slugs inside the microfluidic channel. In this study, we presented a novel µ-RIA chips that is compatible with the conventional gamma counter with automated sampler. Therefore, high-throughput radioimmunoassay can be carried out by the automatic measurement of radioactivity with reduced radiowaste generation. We expect the µ-RIA platform can successfully replace conventional tube-based radioimmunoassay in the future.

Technology Acceptance Model of Financial Technology in Micro, Small, and Medium Enterprises (MSME) in Indonesia

  • PURNAMASARI, Pupung;PRAMONO, Irena Paramita;HARYATININGSIH, Ria;ISMAIL, Shahifol Arbi;SHAFIE, Rohami
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.7 no.10
    • /
    • pp.981-988
    • /
    • 2020
  • Seeing the existence of MSME needs that have still not been met although this sector is undeniably important in Indonesian economy, changes in community behaviour and the intensity of the use of technology in the community, financial technology (fintech) has a lot of potentials to become a part of the solution of the problem commonly faced by MSMEs. Therefore this research needs to be done to observe the potential of fintech in integrating MSMEs in terms of the application of technology and knowledge from the community related to fintech. By using Technology Acceptance Model, this research tries to understand the determinant factors of the fintech application used by MSME. Based on the research framework and model, path analysis method used in this research. This research uses primary data gathered by the questioner, which was distributed to MSME. From the analysis conducted, we can conclude that the external factors tested in this research could have an effect on the behaviour intention through perceived usefulness in MSME practice of financial technology. Large variation in MSME educational background, busineess age and size would become a challenge in promoting fintech application, therefore this finding suggests that fintech should be promoted by highlighting what benefits can be obtained by using fintech application.

Report on the Effects Lipemic Specimen in Anti-ds DNA Antibody Test (Anti-ds DNA 항체 검사 시 Lipemic 검체의 영향에 관한 보고)

  • Cheon, Jun Hong;Kim, Whe Jung;Kim, Sung Ho;Moon, Hyoung Ho;Yoo, Seon Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.153-157
    • /
    • 2014
  • Purpose: SLE (systemic lupus erythematosus) is an inflammatory autoimmune disease, characterized by various autoantibody. The detection of Anti double-stranded DNA (Anti-ds DNA) is important in the diagnostics of SLE, and include the American College of Rheumatology (ACR) diagnostic criteria for SLE. Also SLE disease activity and correlativity with the level Anti-ds DNA antibody have been reported and Anti-ds DNA antibody quantitative test is very useful for tracing before and after SLE treatment. When These Anti-ds DNA antibody test (Farr assay: $^{125}I$ labeled ds-DNA and bound Anti-ds DNA antibodies complex in serum is precipitated by ammonium sulfate and used to centrifugation, measured it) inhaled supernatant after centrifugation, a lipemic specimen does not facilitate the formation of precipitate and also occurs situation was inhaled with precipitate. To solve these problems, The Influence of the degree of lipemic specimen was evaluated. Materials and Methods: September 2012 to February 2013, We selected lipemic samples (n=81) of specimen commissioned by Anti-ds DNA antibody test. Lipemic samples were done pre-treatment (high-speed centrifugation: 14,000 rpm 5 mins) used a micro-centrifuge (Eppendorf Model 5415D). At the same time lipemic specimen and pre-treatment samples were performed Anti-ds DNA antibody test (Anti-ds DNA kit, Trinity Biotech, Ireland). Statistical analysis were analyzed Pearson's correlation coefficients and regression and paired t-test, and Difference (%). Results: Experimental group 1 (Lipemic Specimen Anti-ds DNA Ab concentration ${\leq}7IU/mL$) at y=0.368X+4.732, $R^2=0.023$, Pearson's correlation coefficient was 0.154, paired t-test (P=0.003), Difference (%) mean 65.7 and showed a statistically significant difference. Experimental group 2 (Lipemic Specimen Anti-ds DNA Ab concentration ${\geq}8IU/mL$) at y=0.983X+0.298, $R^2=0.994$, Pearson's correlation coefficient showed 0.997, paired t-test (P=0.181), Difference (%) mean -5.53 made no statistically significant difference. Conclusion: Lipemic sample of low Anti-ds DNA Ab concentration (2.5-7 IU/mL) and the result is obtained pre-treatment (high-speed centrifugation: 14,000 rpm 5 mins) were made a significant difference statistically. Anti-ds DNA is one of the primary auto-antibodies present in patients with SLE, and remain an important diagnostic test for SLE. Therefore, we recommend preprocessing (high-speed centrifugation: 14,000 rpm 5 mins) in order to exclude the influence of lipemic specimen.

  • PDF