• Title/Summary/Keyword: Micro-Power

Search Result 1,670, Processing Time 0.026 seconds

Extreme Job, How Will We Survive Since "Candlelight Protest"? -A Revival of Comic Mode and a Comedy Film in the Age of Self-Management (<극한직업>, '촛불혁명' 이후 어떻게 버티며 살아남을 것인가? -코믹 모드의 부활과 자기경영 시대의 코미디영화)

  • Chung, Young-Kwon
    • Journal of Popular Narrative
    • /
    • v.26 no.3
    • /
    • pp.221-254
    • /
    • 2020
  • This paper finds a solution in the social context which cannot be explained thoroughly by well-timed release date, revival of comedy films, and the attraction of Lee Byeong-heon's comedy etc. while it throws question of how the film, Extreme Job captivated 16 million audience. The incredible hits of Extreme Job cannot be explained by analyzing the text alone. After this essay investigates a function and a role of comedy as a public sphere, it examines people's desires and wishes in the comedy and other genres since 2008 when the conservative government has seized power. Since 2008 a series of dark tone's action thriller, social problem film, and disaster film have emerged, these genres showed absence of public security, crisis of democracy and criticism against rulling class. On the other hand, hit comedy films have showed escapism such as weepie, nostalgia, and fantasy at the same time, generally. Although Veteran (2015) is not full-blown comedy, after this film's big success, "comic mode" has gradually revived. A light tone's films which are truer to genre rules has started representing the wishes of people toward social reforms and changes. Meanwhile, "Candlelight Protest" served as a momentum to recover the democracy which has been in crisis, but it could not lead changes in economic and daily lives. Exreme Job can be read as a question how we will survive since "Candlight Protest." The lives of detectives as self-employed workers who has taken over a fried chicken restaurant for going undercover are appearances of ordinary persons who must survive in the edless conpetition. Furthermore, this film shows a dream of a "great success myth" which becomes well-known as a famous restaurant and a self-management such as brand-naming and an exapansion of franchise business. We can read ganster's chicken franchises as a huge distribution industry which disturbs market system by delivering drugs secretly. While applauses that we give to the police having identities of self-employed workers which sweeps the ganster are giving support to oridinary neighborhood like us, they are also wishes of people who long for the restoration of publicness of police in the market which is becoming increasingly privatized today. A significance of this essay is to examine Extreme Job in terms of the geography of film genres and the revival of comic mode sicne 2008 at the macro level, and is to read the film in the perspective of the problems of economic and daily lives which has been still unsolved since "Candlelight Protest" at the micro level.

Dry etching of polycarbonate using O2/SF6, O2/N2 and O2/CH4 plasmas (O2/SF6, O2/N2와 O2/CH4 플라즈마를 이용한 폴리카보네이트 건식 식각)

  • Joo, Y.W.;Park, Y.H.;Noh, H.S.;Kim, J.K.;Lee, S.H.;Cho, G.S.;Song, H.J.;Jeon, M.H.;Lee, J.W.
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.1
    • /
    • pp.16-22
    • /
    • 2008
  • We studied plasma etching of polycarbonate in $O_2/SF_6$, $O_2/N_2$ and $O_2/CH_4$. A capacitively coupled plasma system was employed for the research. For patterning, we used a photolithography method with UV exposure after coating a photoresist on the polycarbonate. Main variables in the experiment were the mixing ratio of $O_2$ and other gases, and RF chuck power. Especially, we used only a mechanical pump for in order to operate the system. The chamber pressure was fixed at 100 mTorr. All of surface profilometry, atomic force microscopy and scanning electron microscopy were used for characterization of the etched polycarbonate samples. According to the results, $O_2/SF_6$ plasmas gave the higher etch rate of the polycarbonate than pure $O_2$ and $SF_6$ plasmas. For example, with maintaining 100W RF chuck power and 100 mTorr chamber pressure, 20 sccm $O_2$ plasma provided about $0.4{\mu}m$/min of polycarbonate etch rate and 20 sccm $SF_6$ produced only $0.2{\mu}m$/min. However, the mixed plasma of 60 % $O_2$ and 40 % $SF_6$ gas flow rate generated about $0.56{\mu}m$ with even low -DC bias induced compared to that of $O_2$. More addition of $SF_6$ to the mixture reduced etch of polycarbonate. The surface roughness of etched polycarbonate was roughed about 3 times worse measured by atomic force microscopy. However examination with scanning electron microscopy indicated that the surface was comparable to that of photoresist. Increase of RF chuck power raised -DC bias on the chuck and etch rate of polycarbonate almost linearly. The etch selectivity of polycarbonate to photoresist was about 1:1. The meaning of these results was that the simple capacitively coupled plasma system can be used to make a microstructure on polymer with $O_2/SF_6$ plasmas. This result can be applied to plasma processing of other polymers.

Dry Etching of Flexible Polycarbonate and PMMA in O2/SF6/CH4 Discharges (O2/SF6/CH4 플라즈마를 이용한 플렉시블 Polycarbonate와 PMMA의 건식 식각)

  • Joo, Y.W.;Park, Y.H.;Noh, H.S.;Kim, J.K.;Lee, J.W.
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.2
    • /
    • pp.85-91
    • /
    • 2009
  • There has been a rapid progress for flexible polymer-based MEMS(Microelectromechanical Systems) technology. Polycarbonate (PC) and Poly Methyl Methacrylate (PMMA), so-called acrylic, have many advantages for optical, non-toxic and micro-device application. We studied dry etching of PC and PMMA as a function of % gas ratio in the $O_2/SF_6/CH_4$ temary plasma. A photoresist pattern was defined on the polymer samples with a mask using a conventional lithography. Plasma etching was done at 100 W RIE chuck power and 10 sccm total gas flow rate. The etch rates of PMMA were typically 2 times higher than those of PC in the whole experimental range. The result would be related to higher melting point of PC compared to that of PMMA. The highest etch rates of PMMA and PC were found in the $O_2/SF_6$ discharges among $O_2/SF_6$, $O_2/CH_4$ and $SF_6/CH_4$ and $O_2/SF_6/CH_4$ plasma composition (PC: ${\sim}350\;nm/min$ at 5 sccm $O_2/5$ sccm $SF_6$, PMMA: ${\sim}570\;nm/min$ at 2.5 sccm $O_2/7.5$ sccm $SF_6$). PC has smoother surface morphology than PMMA after etching in the $O_2/SF_6/CH_4$ discharges. The surface roughness of PC was in the range of 1.9$\sim$3.88 nm. However, that of PMMA was 17.3$\sim$26.1 nm.

Investigation of Plugging and Wastage of Narrow Sodium Channels by Sodium and Carbon Dioxide Interaction (소듐과 이산화탄소 반응에 의한 소듐유로막힘 및 재료손상 현상 연구)

  • Park, Sun Hee;Min, Jae Hong;Lee, Tae-Ho;Wi, Myung-Hwan
    • Korean Chemical Engineering Research
    • /
    • v.54 no.6
    • /
    • pp.863-870
    • /
    • 2016
  • We investigated the physical/chemical phenomena that a slow loss of $CO_2$ inventory into sodium after the sodium-$CO_2$ boundary failure in printed circuit heat exchangers (PCHEs), which is considered for the supercritical $CO_2$ Brayton cycle power conversion system of a sodium-cooled fast reactor (SFR). The first phenomenon is plugging inside narrow sodium channels by micro cracks and the other one is damage propagation referred to as wastage combined with the corrosion/erosion effect. Experimental results of plugging shows that sodium flow immediately stopped as $CO_2$ was injected through the nozzle at $300{\sim}400^{\circ}C$ in 3 mmID sodium channels, whereas sodium flow stopped about 60 min after $CO_2$ injection in 5 mmID sodium channels. These results imply that if pressure boundary of sodium-$CO_2$ fails a narrow sodium channel would be plugged by reaction products in a short time whereas a relatively wider sodium channel would be plugged with higher concentration of reaction products. Wastage by the erosion effect of $CO_2$ (200~250 bar) hardly occurred regardless of the kinds of materials (stainless steel 316, Inconel 600, and 9Cr-1Mo steel), temperature ($400{\sim}500^{\circ}C$), or the diameter of the $CO_2$ nozzle (0.2~0.8 mm). Velocities at the $CO_2$ nozzle were specified as Mach 0.4~0.7. Our experimental results are expected to be used for determining the design parameters of PCHEs for their safeties.

Dispersion Effect Based on Irradiation Dose and Position of QRD Microwave in Sealed Chamber (밀폐된 챔버의 QRD 마이크로파 조사용량과 위치에 따른 분산효과)

  • Kim, Jin Hyun;Han, Chung Su;Lee, Keun Woo;Lim, Kyoung Ho;Lee, Jae Hyun;Kim, Kyung Min;Ha, Yu Shin
    • Journal of Bio-Environment Control
    • /
    • v.23 no.1
    • /
    • pp.1-10
    • /
    • 2014
  • This study analyzed the efficiency and uniformity by measuring the temperature change depending on the position in the chamber with the use of QRD (quadratic residue diffusor) microwave capable of inducing even sterilization by changing wavelength phase difference and enhancing the effect on low power. The results are summarized as follows: When irradiating 7 kW of QRD microwave, the highest efficiency was obtained at 35 cm height and in the center of the chamber. When irradiating 5 kW of QRD microwave, high efficiency was obtained on the sides of the chamber. When irradiating 3 kW of QRD microwave to Magnetrons 1, 2 and 3, the temperature uniformity according to the position of the bars was similar in the position of Bar 1 and 2. When irradiating 3 kW of QRD microwave to Magnetrons 3, 4 and 5, the temperature increased by approximately 10 to 20% in Bar 3. When irradiating 5, 7 and 9 kW of magnetron, the average temperature during the irradiation time increased in a similar form independently of the position of the bars. On the other hand, the efficiency of the chamber's proper internal volume was not necessarily proportional to the irradiation dose. When irradiating 3 kW of magnetron for 60 120 and 180 seconds, the temperature increased by approximately 5 to 10 at the edge of the chamber according to the irradiation position of magnetron. The temperature distribution for each position in the horizontal plane was relatively uniform, and the temperature had a tendency to slightly increase at the edge. When irradiating 5, 7 and 9 kW of magnetron, the temperature relatively evenly increased independently of the position of the bars. It was thought necessary to increase the irradiation dose by approximately 10 to 20% by considering the difference in temperature rise according to the position of magnetron.

Effect of the Nematode Sterilization of Nursery Medium using QRD Microwave in the Plant Factory (QRD 마이크로파를 이용한 식물공장용 배지의 멸균 효과)

  • Kim, Jin Hyun;Kim, Tae Wook;Lee, Keun Woo;Ha, Yu Shin;Lee, Jae Hyun;Kim, Kyung Min
    • Journal of Bio-Environment Control
    • /
    • v.22 no.2
    • /
    • pp.100-107
    • /
    • 2013
  • Unlike general microwave, QRD (Quadratic Residue Diffusor) Microwave used in this study is known as a new technology that enhances the sterilization effect with low power because it is possible to induce the average sterilization by changing wavelength phase difference. Therefore, basic research was conducted on the function that could sterilize culture media for plant factory by using environmentally friendly and low energy consuming QRD Microwave. The results are as follows: It was confirmed that there was no external deformation in the polyurethane foam and rock wool medium when changing the microwave level between 2 and 8 kW in different water content of culture media. However, PDA solid media at 2 kW were not dissolved in 60 and 180 seconds. All of the media were dissolved in other processing. There was little difference in the microwave irradiation level and surface temperature of the strain according to the processing time between Bacillus sp. and Burkholderia sp. In the sterility test according to the microwave irradiation level and processing time, it was confirmed that both Bacillus sp. and Burkholderia sp. grew in the microwave level 2 kW regardless of time. In the microwave level 6 kW, all experimental groups except the processing of Burkholderia sp. for 60 seconds were sterilized, and all of Bacillus sp. was killed in the all experimental groups. In the microwave level 8 kW, it was confirmed that both Bacillus sp. and Burkholderia sp. were sterilized regardless of time. The temperature in microwave-processed media after contaminating strains to each medium was maintained at more than 100 in polyurethane foam and rock wool medium after 60 seconds. In general, it was shown that it was possible to sterilize after 60 seconds. Therefore, it is considered that Bacillus sp. and Burkholderia sp. which are the biggest problems in the plant factory can be adequately sterilized by QRD Microwave used in this study.

Recent Progress in Air Conditioning and Refrigeration Research - A Review of papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 1998 and 1999 - (공기조화, 냉동 분야의 최근 연구 동향 - 1998년 1999년 학회지 논문에 대한 종합적 고찰 -)

  • 이재헌;김광우;김병주;이재효;김우승;조형희;김민수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.12
    • /
    • pp.1098-1125
    • /
    • 2000
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 1998 and 1999 has been done. Focus has been put on current status of research in the aspect of heating, cooling, ventilation, sanitation and building environment. The conclusions are as follows. 1) A review of the recent studies on fluid flow, turbomachinery and pipe-network shows that many experimental investigations are conducted in applications of impingement jets. Researches on turbulent flows, pipe flows, pipe-networks are focused on analyses of practical systems and prediction of system performance. The results of noise reduction in the turbomachinery are also reported. 2) A review of the recent studies on heat transfer analysis and heat exchanger shows that there were many papers on the channel flow with the application to the design of heat exchanger in the heat transfer analysis. Various experimental and numerical papers on heat exchanger were also published, however, there were few papers available for the analysis of whole system including heat exchanger. 3) A review of the recent studies on heat pump system have focused on the multi-type system and the heat pump cycle to utilize treated sewage as the heat source. The defrosting and the frosting behaviors in the fin-tube heat exchanger is experimentally examined by several authors. Several papers on the ice storage cooling system are presented to show the dynamic simulation program and optimal operation conditions. The study on the micro heat pipes for the cooling of high power electronic components is carried out to examine the characteristics of heat and mass transfer processed. In addition to these, new type of separate thermosyphon is studied experimentally. 4) The recent studies on refrigeration/air conditioning system have focused on the system performance and efficiency for new alternative refrigerants. New systems operating with natural refrigerants are drawing lots of attention. In addition to these, evaporation and condensation heat transfer characteristics of traditional and new refrigerants are investigated for plain tubes and also for microfin tubes. Capillary tubes and orifice are main topics of research as expansion devices and studies on thermophysical properties of new refrigerants and refrigerant/oil mixtures are widely carried out. 5) A review of the recent studies on absorption cooling system shows that numerous experimental and analytical studies on the improvement of absorber performance have been presented. Dynamic analysis of compressor have been performed to understand its vibration characteristics. However research works on tow-phase flow and heat transfer, which could be encountered in the refrigeration system and various phase-change heat exchanger, were seemed to be insufficient. 6) A review of recent studies on duct system shows that the methods for circuit analysis, and flow balancing have been presented. Researches on ventilation are focused on the measurement of ventilation efficiency, and variation of ventilation efficiency with ventilation methods by numerous experimental and numerical studies. Furthermore, many studies have been conducted in real building in order to estimate indoor thermal environments. Many research works to get some information for cooling tower design have been performed but are insufficient. 7) A review on the recent studies on architectural thermal environment and building mechanical systems design shows that thermal comfort analysis is sitting environment, thermal performance analysis of Korean traditional building structures., and evaluation of building environmental load have been performed. However research works to improve the performance of mechanical system design and construction technology were seemed to be insufficient.

  • PDF

The Effect of Aging Treatment on the High Temperature Fatigue Fracture Behavior of Friction Welded Domestic Heat Resisting Steels (SUH3-SUS 303) (마찰용접된 국산내열 강 (SUH3-SUS303 )의 시효열처리가 고온피로강도 및 파괴거동에 미치는 영향에 관한 연구)

  • Lee, Kyu-Yong;Oh, Sae-Kyoo
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.17 no.2
    • /
    • pp.93-103
    • /
    • 1981
  • It is well-known that nowadays heat resisting and anti-corrosive materials have been widely used as the components materials of gas turbines, nuclear power plants and engines etc. In the fields of machine production industry. And materials for engine components, like as the exhaust valve of internal combustion engine, have been required to operate under the high temperature range of $700^{\circ}C$-$800^{\circ}C$ and high pressured gas with repeated mechanical load for the high performance of engines. For these components, friction welding for bonding of dissimilar steels can be applied for in order to obtain process shortening, production cost reduction and excellent bonding quality. And age hardening recently has been noticed to the heat resisting materials for further strengthening of high temperature strength, especially high temperature fatigue strength. However, it is difficult to find out any report concerning the effects of age hardening for strengthening high temperature fatigue strength to the Friction welded heat resisting and anti-corrosive materials. In this study the experiment was carried out as the high temperature rotary bending fatigue testing under the condition of $700^{\circ}C$ high temperature to the friction welded domestic heat resisting steels, SUH3-SUS303, which were 10hr., 100hr. aging heat treated at $700^{\circ}C$ after solution treatment 1hr. at $1, 060^{\circ}C$ for the purpose of observing the effects of the high temperature fatigue strength and fatigue fracture behaviors as well as with various mechanical properties of welded joints. The results obtained are summarized as follows: 1) Through mechanical tests and micro-structural examinations, the determined optimum welding conditions, rotating speed 2420 rpm, heating pressure 8kg/mm super(2), upsetting pressure 22kg/mm super(2), the amount of total upset 7mm (heating time 3 sec and upsetting time 2 sec) were satisfied. 2) The solution treated material SUH 3, SUS 303, have the highest inclination gradient on S-N curve due to the high temperature fatigue testing for long time at $700^{\circ}C$. 3) The optimum aging time of friction welded SUH3-SUS 303, has been recognized near the 10hr. at $700^{\circ}C$ after the solution treatment of 1hr. at $1, 060^{\circ}C$. 4) The high temperature fatigue limits of aging treated materials were compared with those of raw material according to the extender of aging time, on 10hr. aging, fatigue limits were increased by SUH 3 75.4%, SUS 303 28.5%, friction welded joints SUH 3-SUS 303 44.2% and 100hr. aging the rates were 64.9%, 30.4% and 36.6% respectively. 5) The fatigue fractures occurred at the side of the base matal SUS303 of the friction welded joints SUH 3-SUS 303 and it is difficult to find out fractures at the friction welding interfaces. 6) The cracking mode of SUS 303, SUH 3-303 is intergranular in any case, but SUH 3 is fractured by transgranular cracking.

  • PDF

Methods that can be Substituted for Earth Healing of Seedling by Using the Plastic Vinyl and their Micro-climatical Characteristics (프라스틱비닐제품(製品)을 이용(利用)한 가식대치방법(假植代置方法)과 미기상학적(微氣象學的) 특성(特性))

  • Ma, Sang Kyu;Lee, Jang Soo
    • Journal of Korean Society of Forest Science
    • /
    • v.47 no.1
    • /
    • pp.44-51
    • /
    • 1980
  • In order to find out the suitable methods that can omit the earth healing and increase the survival through improving the seedling-healing and transportable methods. Several trials with plastic vinyl have been done and its results are as follows: 1. Though P. rigitaeda seedling have been stored in the black and white vinyl sack for 35 days in the storehouse. This seedling have survived with very high percentage as Table 1. This means that the earth healing work at the nursery or planting area can be omitted if seedling sould be stored in the storehouse by using the vinyl sack. The possibilities of long-period storage in the black and white vinyl sack seem to be come from the reasons that air humidity in the sack is nearly 100% and its air temperature is only around $15^{\circ}C$ with very little difference between day and night time. This sack also can be utilized in place of the planting sack, and though this sack with seedling have been laid under direct sunshine for 1 to 2 days. Any difference between the sack stored in the storehouse has not been observed on the survival specially Table 2. 2. When the bundled seedling have been covered with the black and white vinyl instead of earth healing, even if these seedling have been laid for 18 days under the vinyl. This seedling show us high survival as Table 3. High humidity with nearly 95%, very little difference of air temperature between day and night time under the vinyl and not so big difference between out-and inside temperature could be reasons of high survival to be considered. So through covering by the black and white vinyl. The labour power for earth healing works can be saved also. 3. In order to protect the healed seedling from the direct sunshine and the eva-transpiration. Black vinyl net and reed mat could be effective for this purpose. Because vinyl net could intercept around one to third, reed mat two to third of total solar energy and also suppress more than 50% of total water loss by the transpiration.

  • PDF

Developed an output device for high-frequency cosmetic medical equipment using micro multi-needle (마이크로 멀티니들을 이용한 고주파 피부미용 의료기기를 위한 출력 장치 개발)

  • Kim, Jun-tae;Joo, Kyu-tai;Cha, Eun Jong;Kim, Myung-mi;Jeong, Jin-hyoung
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.14 no.5
    • /
    • pp.394-402
    • /
    • 2021
  • The entry of an aging society and the extension of human life expectancy, the increasing interest in women's social advancement and men's appearance, and the natural interest in K-culture through media media, while receiving worldwide attention, Focus on K-Bueaty. Recently, looking at the occupation of the medical tourism field, in the case of aesthetic medicine tourism such as molding and dermatology, it has gained popularity not only in Asia such as China and Japan, but also in North America and Europe. The first external confirmation of human aging is the wrinkles on the skin of the face. Clean, wrinkle-free, elastic and healthy skin is a desire of most people. Skin condition and condition such as focused ultrasonic stimulation (HIFU: High Intensity Focused Utrasound) and low frequency, high frequency (RF: Radio Frequency), galvanic therapy using microcurrent, cryotherapy using rapid cooling, etc. Depending on the method of management, the effect of the treatment differs depending on the output and the stimulation site, etc., even in the treatment of medical equipment and beauty equipment using the same mechanism. In this research, in order to develop invasive high-frequency dermatological devices using a large number of beauty medical devices and microneedles of beauty devices, the international standards IEC 60601-2 (standards for individual medical devices) and MFDS (Ministry of) We designed and developed a high-frequency output device in compliance with the high-frequency stimulation standard announced in the Food and Drug Safety (Ministry of Food and Drug Safety). The circuit design consists of an amplifier (AMP: Amplifier) using Class-A Topology and a power supply device using Half-Bridge Topology. As a result of measuring the developed high-frequency output device, an average efficiency of 63.86% was obtained, and the maximum output was measured at 116.7W and 50.67dBm.