• 제목/요약/키워드: Micro-Channel

검색결과 611건 처리시간 0.03초

마이크로채널 내의 FC-72 흐름응축에 관한 수치적 연구 (Numerical Study on FC-72 Condensing Flow in a Micro-Channel)

  • 김성민
    • 한국가시화정보학회지
    • /
    • 제13권1호
    • /
    • pp.30-34
    • /
    • 2015
  • This study concerns flow and heat transfer characteristics of FC-72 condensing flow in a micro-channel. A computational model of condensing flow with a hydraulic diameter of 1 mm is constructed using the FLUENT computational fluid dynamics code. The computed void fraction contour plots are presented for different mass velocities. The smooth-annular, wavy-annular, transition and slug flows are observed with the model, which are quite similar to those observed in a micro-channel experiment. The computed two-phase condensing heat transfer coefficient is compared with previous empirical correlation for two-phase condensation heat transfer in micro-channels.

미소 채널의 형상변화에 의한 혼합효율에 관한 수치 해석적 연구 (Numerical Analysis on Mixing Efficiency in a Micro-channel with Varied Geometry)

  • 윤준용;한규석;변성준
    • 공업화학
    • /
    • 제16권2호
    • /
    • pp.275-281
    • /
    • 2005
  • 본 연구에서는 격자 볼츠만 방법 중 Scalar Passive 코드를 사용하여 미소채널 내에서의 수동형 믹서의 혼합에 대하여 계산을 수행하였다. 미소채널 내에서의 수동형 믹서의 혼합에 대하여 유선과 압력분포를 통해 혼합과 압력 강하를 물리적으로 규명하였으며, 혼합에 영향을 주는 인자에 대해서 알아보았다. 수동형 믹서의 경우 고정물의 간격보다는 고정물의 개수와 고정물의 크기가 혼합효율과 압력강하에 큰 영향을 주었다.

피코초 레이저를 이용한 고세장비 미세 홀가공의 실험적 연구 (Experimental study on micro-hole drilling with high aspect ratio using picosecond laser)

  • 오부국;김종기;김두영;이승기;정수화;홍순국
    • 한국레이저가공학회지
    • /
    • 제18권2호
    • /
    • pp.11-13
    • /
    • 2015
  • Pressure-drop in a micro-channel is critical when a hole diameter is less then 100um with the high aspect ratio, more than 40. To minimize these pressure loss for micro-channel applications is important and there would be the best hole diameter, taper angle, and their combinations. In this work, the parametric study for laser drilling of anodized material is conducted to obtain the micro-channel hole with high aspect ratio.

미세채널 전사성 향상을 위한 사출성형 공정최적화 기초연구 (A study on the process optimization of injection molding for replicability enhancement of micro channel)

  • 고영배;김종선;유재원;민인기;김종덕;윤경환;황철진
    • Design & Manufacturing
    • /
    • 제2권1호
    • /
    • pp.45-50
    • /
    • 2008
  • Micro channel is to fabricate desired pattern on the polymer substrate by pressing the patterned mold against the substrate which is heated above the glass transition temperature, and it is a high throughput fabrication method for bio chip, optical microstructure, etc. due to the simultaneous large area patterning. However, the bad pattern fidelity in large area patterning is one of the obstacles to applying the hot embossing technology for mass production. In the present study, stamper of cross channel with width $100{\mu}m$ and height $50{\mu}m$ was manufactured using UV-LiGA process. Micro channel was manufactured using stamper manufactured in this study. Also replicability appliance was evaluated for micro channel and factors affected replicability were investigated using Taguchi method.

  • PDF

열모세관에 의한 미소액적 구동과 모세관 밸브 (Micro droplet driven by thermocapillary and capillary valve)

  • 임남혁;김성욱;유정열
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.1777-1782
    • /
    • 2003
  • This paper presents the design, fabrication, and testing of the capillary-induced pressure drop valve, thermocapillary pumping of liquid droplet in hydrophilic channels and the splitting of droplet. The capillaryinduced pressure drop is derived with thermodynamic approach considering three-dimensional meniscus shape which is essential for calculating pressure drop in the diverging shape channel when the aspect ratio is close to one. The micro channel is fabricated via MEMS processes, which consists of the liquid stop valve to retard the liquid droplet, thermocapillary pumping region and the bifurcation region. Also the micro heaters are fabricated to drive the droplet by thermocapillary. The theoretical approaches agree well with the experimental data. The functionality of capillary valve is confirmed to be valid when the aspect ratio is smaller than one. To overcome the difficulty in splitting of the droplet due to the pressure drop in the general Y-shape channel, the protrusion shape is employed for easy splitting in the bifurcation channel.

  • PDF

Micro-EDM 채널가공에서 초음파 가진의 영향 (Effect of Ultrasonic Vibration on Micro-EDM Channel)

  • 임희성;홍민성
    • 한국생산제조학회지
    • /
    • 제25권6호
    • /
    • pp.421-425
    • /
    • 2016
  • Micro-EDM is one of the recent fine-machining technologies. Micro-EDM is widely used in precision processes because products manufactured via EDM are free from workpiece hardness. However, the debris produced during the process cause many problems such as reduced precision of the process. The first solution of this problem involves using the milling hole process. Micro-EDM hole process involves an electrode moving rapidly in the vertical direction via a servo system to disperse debris. However, this process can cause reduced work efficiency owing to contact between the electrode and workpiece. In this study, ultrasonic vibration is added to micro-EDM channel machining. Ultrasonic vibration removes the debris during machining and enables precision machining. Consequently, a clean work environment for the subsequent processes is maintained.

마이크로 채널 충전 과정의 유동 현상(I) - 유동 가시화 실험 - (Flow Phenomena in Micro-Channel Filling Process (I) - Flow Visualization Experiment -)

  • 김동성;이광철;권태헌;이승섭
    • 대한기계학회논문집A
    • /
    • 제26권10호
    • /
    • pp.1982-1988
    • /
    • 2002
  • Micro-injection molding and microfluidic devices with the help of MEMS technologies including the LIGA process are expected to play important roles in micro-system industries, in particular the bio-application industry, in the near future. Understanding fluid flows in micro-channels is important since micro-channels are typical geometry in various microfluidic devices and mold inserts for micro-injection molding. In the present study, Part 1, an experimental investigation has been carried out to understand the detailed flow phenomena in micro-channel filling process. Three sets of micro-channels of different thickness (40um,30um and 2011m) were fabricated using SU-8 on silicon wafer substrate. And a flow visualization system was developed to observe the filling flow into the micro-channels. Experimental flow observations are extensively made to find the effects of pressure, inertia force, viscous force and surface tension. A dimensional analysis for experimental results was carried out and several relationships A dimensionless parameters are obtained.

PIV measurement of oscillatory flow in a micro-channel as a bronchiole model

  • LEE Won-je;KAWAHASHI Massaki;HIRAHARA Hiroyuki
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2004년도 Proceedings of 2004 Korea-Japan Joint Seminar on Particle Image Velocimetry
    • /
    • pp.125-134
    • /
    • 2004
  • The improvement of artificial respiration method has brought about the decrease in mortality of pulmonary diseases patients. Various respiratory curative methods, inclusive of HFOV (High Frequency Oscillatory Ventilation), have been developed for more effectual and less harmful management of acute respiratory failure. However, the mechanism of gas transfer and diffusion in a bronchiole has not yet been clarified in detail. As a first approach to the problem, we measured oscillatory flows in a Y-shaped micro-channels as bronchiole model by micro Particle Image Velocimetry(micro PIV). In order to establish the fundamental technique of PIV measurements on oscillatory air flow in a micro-channel, we used about 500-nm-diameter incense smoke particles, a diode laser, a high speed camera including an objective lens, and a HFOV, which is effective technique for medical care of pulmonary disease patients, especially, infants. The bronchiole model size is that parent tube is $500\{mu}m$ width and $500\{mu}m$ depth, and daughter tubes are $450\{mu}m$ width and $500\{mu}m$ depth. From this study made on the phenomenon of fluid in micro size bronchus branch of a lung, we succeeded to get time series velocity distribution in a micro scale bronchial mode. The experimental results of velocity distribution changing with time obtained by micro PIV can give fundamental knowledge on oscillatory airflow in micro-channel.

  • PDF

마이크로 채널 충전 과정의 유동 현상 (II) - 수치 해석 - (Flow Phenomena in Micro-channel Filling Process (II) - Numerical Analysis -)

  • 김동성;이광철;권태헌;이승섭
    • 대한기계학회논문집A
    • /
    • 제27권5호
    • /
    • pp.657-665
    • /
    • 2003
  • Several interesting results were obtained from the flow visualization experiment in the accompanying paper, Part I. in the present study, Part II, a numerical study has been carried out to explain the detailed flow phenomena in micro-channel filling process. Hele-Shaw flow approximation was applied to the micro-channel geometry based on the small characteristic length. And surface tension effect has been introduced on the flow front as the boundary condition with the help of a dynamic contact angle concept between the melt front and the wall. A dimensional analysis for numerical results was carried out and a strong relationship between dimensionless pressure and Capillary number is obtained. The numerical analysis results are compared with the flow visualization experimental observations. And the numerical system developed in the present study seems to be able to predict the interesting micro-channel filling flow characteristics observed from experiments.

미세 유체통로를 이용한 대면적 평판 구조의 부양에 관한 연구 (Study on the Micro Channel Assisted Release Process)

  • 김재흥;이준영;김용권
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1924-1926
    • /
    • 2001
  • A novel wet release process ($\mu$ CARP - Micro Channel Assisted Release Process) for releasing an extreme large-area plate structure without etching hole is proposed and experimented. Etching holes in conventional process reduce a effective area and degrade an optical characteristics by a diffraction. In addition, as the area of a released structure increases, the stietion becomes more serious. The proposed process resolves these problems by the introduction of a micro fluidic channel beneath the structure which will be released. In this paper, a 5 mm${\times}$5mm-single crystal silicon plate structure was released by the proposed $\mu$CARP without etch holes on the structure. The variation in etching time with respect to the of the introduced micro channel is also examined. This process is expected to be beneficial for the actuator of a nano-scale data storage and the scanning mirror.

  • PDF