• 제목/요약/키워드: Micro-CYCLONE

검색결과 11건 처리시간 0.026초

Cyclone separator의 형상에 따른 미세플라스틱 입자 거동 수치해석 연구 (Numerical Analysis Study on Micro-plastic Particle behavior According to the Shape of Cyclone Separator)

  • 강인선;서원준;유동호;김영식;김형철;임석연
    • Tribology and Lubricants
    • /
    • 제40권2호
    • /
    • pp.61-66
    • /
    • 2024
  • Micro-plastics are synthetic high-differentiation chemicals of less than 5mm in size, and are deposited not only on the sea surface but also on the coast. If these micro-plastics are not properly separated from the sand, they can threaten marine ecosystems. Thus, in the present study, we aimed to apply cyclone separator to the micro-plastic retrieval in order to predict the movement of particles according to the formation of the cyclone separator by applying the centrifugal force of the particle in accordance with the rotational movement of the air. The cyclone separator has three shapes, the first one is a typical interconnected cyclone separator. The second is the horn form, except for the cylinder in a regular cyclone separator, and the third is a form that increases the horn's height twice in the second. The numerical analysis simulation of the Cyclone separator used the Fluent software package. The output speed of the Cyclone separator was 5 to 13m/s at 1m/s intervals. The simulated particles include sand, Styrofoam, PET, PP, and PU. Sand particles are assigned a fixed diameter of 2mm, while other particles have a diameter of 3mm. As a result of the analysis, the first form was not separated from plastic. The Styrofoam separation efficiency in the second showed its highest efficiency at 72.7% at 7m/s, and the efficiency decreased after 12m/s as the sand particles were mixed into the plastic attachment location. In the third form, the separation efficiency of Styrofoam at 12m/s was highest at 67.9%.

마이크로 사이클론 연소기의 혼합 및 유동특성에 관한 수치해석 연구 (Numerical Simulation of the Mixing and Flow Characteristics in a Micro Cyclone Combustor)

  • 오창보;최병일;한용식;김명배;황철홍
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.1900-1905
    • /
    • 2007
  • A micro cyclone combustor was developed to be used as a heat source of thermoelectric power generator (TPG). The cyclone combustor was designed so that fuel and air were supplied to the combustion chamber separately. The mixing and flow characteristics in the combustor were investigated numerically. The global equivalence ratio (${\Phi}$), defined using the fuel and air flow rates, was introduced to examine the flow features of the combustor. The mixing of fuel and air inside the combustor could be well understood using the fuel concentration distribution. It was found that the weak recirculating zone was formed upper the fuel-supplying tube in case of ${\Phi}$ < 1.0. In addition, it was found that small regions that have a negative axial velocity exist near the fuel injection ports. It is assumed that these negative axial velocity regions can stabilize a flame inside the micro cyclone combustor.

  • PDF

마이크로 사이클론 연소기의 화염 안정화 기구 (Flame Stabilization Mechanism of a Micro Cyclone Combustor)

  • 오창보;최병일;한용식;김명배;황철홍
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2007년도 제34회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.139-144
    • /
    • 2007
  • A micro cyclone combustor was developed to be used as a component of mobile power generator (MPG). The cyclone combustor was designed so that fuel and air were supplied to the combustion chamber separately to prevent a flash-back. The flame shape stabilized inside the micro cyclone combustor was visualized experimentally and the flow field and the combustion characteristics of the combustor were investigated numerically. The global equivalence ratio (${\Phi}$), defined using the fuel and air flow rates, was introduced to examine the overall flow and flame features of the combustor. The flame stabilization mechanism could be well understood using the velocity distribution inside the combustor. For only non-reacting case, it was found that a weak recirculating zone was formed upper the fuel-supplying tube in case of ${\Phi}$ < 1.0. It was also found that small regions that have a negative axial velocity exist near the fuel injection ports for both of non-reacting and reacting case. It was identify that a flame front was stabilized at the negative axial velocity regions near the fuel injection ports.

  • PDF

마이크로 사이클론 연소기의 혼합 및 유동특성에 관한 수치해석 연구 (Numerical Simulation of the Mixing and Flow Characteristics in a Micro Cyclone Combustor)

  • 최병일;한용식;김명배;황철홍;오창보
    • 대한기계학회논문집B
    • /
    • 제31권12호
    • /
    • pp.1042-1047
    • /
    • 2007
  • A micro cyclone combustor was developed to be used as a heat source of thermoelectric power generator (TPG). The cyclone combustor was designed so that fuel and air were supplied to the combustion chamber separately. The mixing and flow characteristics in the combustor were investigated numerically. The global equivalence ratio ($\Phi$), defined using the fuel and air flow rates, was introduced to examine the flow features of the combustor. The mixing of fuel and air inside the combustor could be well understood using the fuel concentration distribution. It was found that the weak recirculating zone was formed upper the fuel-supplying tube in case of ${\Phi}$<1.0. In addition, it was found that small regions that have a negative axial velocity exist near the fuel injection ports. It is assumed that these negative axial velocity regions can stabilize a flame inside the micro cyclone combustor.

Wet Deposition Fluxes of Ions Contributed by Cyclone-, Stationary Front- and Typhoon-associated Rains at the Southwestern Japan Coast

  • Toyonaga, Satoshi;Zhang, Daizhou
    • Asian Journal of Atmospheric Environment
    • /
    • 제10권2호
    • /
    • pp.57-66
    • /
    • 2016
  • Wet deposition fluxes of ions at a coastal site in southwestern Japan in the period 1996-2003 were investigated to quantify the respective contributions of cyclone-, stationary front- and typhoon-associated rains. On average, the deposition fluxes of terrigenous-origin ions, nss-$SO_4{^{2-}}$, $NO_3{^-}$, $NH_4{^+}$ and nss-$Ca^{2+}$ were $37.6{\pm}7.3$, $16.3{\pm}4.2$, $19.0{\pm}3.4$ and $9.6{\pm}4.8meq\;m^{-2}yr^{-1}$, and those of $Na^+$ and $Cl^-$, the major ions in sea water, were $97.0{\pm}38.2$ and $115.2{\pm}48.2meq\;m^{-2}yr^{-1}$, respectively. Cyclone-associated rain constituted more than 50% of the fluxes of the terrigenous ions in almost all years. Stationary front-associated rain also contributed significantly, although the contribution was lower than the contribution by Cyclone-associated rain in almost all years. In particular, the wet deposition flux of nitrogen compounds of $NO_3{^-}$ and $NH_4{^+}$, which are important nutrients for micro-bioactivities in sea surface water, was dominated by cyclone-associated rain. Due to the extreme abundance of $Na^+$ and $Cl^-$ in the rainwater of typhoons, the fluxes of $Na^+$ and $Cl^-$ were contributed substantially by typhoons in years with typhoons' passage although cyclones were still the largest contributor to the fluxes. These results indicate the dominance of cyclones in the wet deposition to the East China Sea areas and the necessity to take rain types into account for a more accurate elucidation of the temporal and spatial variation of the wet deposition.

A STUDY ON SPACE ZONING BY COMPUTING IDLE-TIMES IN CONSTRUCTION PROCESSES

  • Sang-Min Park;Won-Suk Jang;Dong-Eun Lee
    • 국제학술발표논문집
    • /
    • The 5th International Conference on Construction Engineering and Project Management
    • /
    • pp.509-512
    • /
    • 2013
  • An inappropriate space zoning plan causes the unnecessary transportation of construction material and equipment among work areas and increases the disorder of work space. Space zoning is an essential operation management technique which contributes to reduce the process and/or operation idle-time. This paper introduces a method that computes the idle-times between construction operations (or processes) by using Web-CYCLONE. It allows computing with idle-times that affect the construction productivity. Using the idle time between operations and between processes, it computes the optimal number of zones and finds the optimal combination of zones that minimize the idle times. The method contributes to minimize the idle times relative to the operation schedule using complete enumeration. This paper presents the system prototype in detail. A case study is presented to demonstrate the system and verifies the validity of the model. It allows a project manager to establish space zoning plan that effectively segregates a project into optimal number of construction zones and to assign the constrained resources (e.g., laborer, equipment).

  • PDF

RFID Dual-band 리더 시스템의 디지털 코덱 설계 (Implementation of Digital CODEC for RFID Dual-band Reader system)

  • 심재희;이용주;이용석
    • 한국통신학회논문지
    • /
    • 제32권10A호
    • /
    • pp.1015-1022
    • /
    • 2007
  • 본 논문에서는 UHF(Ultra High Frequency)와 MW(Micro Wave) 대역의 RFID 리더 시스템을 위한 디지털 코덱을 제안하였다. 현재 RFID 시스템은 하나의 프로토콜만을 지원하는 것이 대부분이다. 하지만, 현재 제정되어 있는 표준은 5개의 주파수 대역마다 각각 하나씩 제정되어 있고, 전 세계적으로 가장 널리 쓰이고 있는 UHF 대역의 경우에는 A,B,C 타입이 있으며 향후 더 많은 표준이 제정될 것이다. 또한 앞으로 모바일 RFID 시스템의 관심이 고조되면서 하나 이상의 프로토콜을 지원하는 RFID 시스템의 필요성은 더욱 더 증가할 것이다. 따라서 본 논문에서는 UHF 대역과 MW대역의 dual-band RFID 시스템을 위한 디지털 코덱을 제안하였다. UHF 대역은 EPC 클래스 1 제너레이션 2(EPC Class1 Generation2)표준인 18000-6C 와 MW 대역의 표준인 18000-4 표준을 기반으로 시스템을 구현하였다. 설계된 회로는 알테라사의 쿼터스II 를 이용하여 합성 하였다. 목적 디바이스는 Altera 사의 CycloneII 계열인 EP2C20Q240C8이다. 주 클럭 주파수는 19.2MHz 로 설정하였으며 합성 시 사용된 FPGA의 소자(element)는 18,752개이다.

미세먼지 저감을 위한 특허기술들 (Patent Technologies for Reducing Micro-Dust)

  • 조태준;김태수
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제24권2호
    • /
    • pp.9-14
    • /
    • 2020
  • 필터가 장착 된 먼지 감소 팬을 포함하여 새로운 유형의 Composite Cyclone Scrubber를 개발하고, 목표 설치 및 유지 보수 비용에 대해서는 기존 도로 오염 저감 시스템 대비 64 %의 투자비 절감 (61 억 원 vs. 170 억 원), 기존 도로 오염 저감 조치 (72.6 억 원) 대비 사회적 비용편익이 43 % 증가, 50.8 억 원)가 예측되고 있다. 장치의 구성은 송풍기 형 나선형 가이드 베인이며, 분사 압력은 미세먼지를 포집한다. 분사 각도 및 접촉 범위가 다양한 노즐, 스프레이 액체 등과 순환 수를 이용한 스프레이이며, 분사 된 물이 Guide Vane과 45도 각도로 충돌로 인해 오염된 가스를 만나기 때문에 41.4 % 더 많은 미세 먼지를 포집한다. 이는 기존의 집진기보다 141 % 증가한 것이다. 포집 액체, 순환 빗물 및 우물 공급원과 관련하여 우리는 특허에서 막대한 양의 에너지와 경제적으로 절약되는 친환경 시스템을 기대한다. 가이드 베인 및 금속 필터는 90 % 이상의 미세 먼지를 줄였으며, 분무 된 물은 베인과 필터를 청소하여 유지 관리 예산을 최소화했다. 개발 된 설계의 예비 평가를 통해 특징적인 물분사로 인하여 유지 보수 예산을 줄일 수 있다.

FPGA를 이용한 다채널 비동기 통신용 IC 설계 (The Design of Multi-channel Asynchronous Communication IC Using FPGA)

  • 옥승규;양오
    • 대한전자공학회논문지SD
    • /
    • 제47권1호
    • /
    • pp.28-37
    • /
    • 2010
  • 본 논문에서는 FPGA와 VHDL을 이용하여 다채널 비동기 통신용 IC를 설계하였다. 기존에 상용되고 있는 대부분의 비동기 통신용 IC들은 최대 1~2채널(Channel)로 구성되어 있다. 따라서 2채널 이상의 통신 시스템을 구성할 때 원가가 높아지고 구현하기도 복잡해진다. 그리고 매우 적은 송수신 버퍼(Buffer)를 가지고 있으므로 고속으로 대용량의 데이터를 전송할 경우 마이크로프로세서에 걸리는 부하가 많아지게 된다. 이러한 문제를 해결하기 위해 본 논문에서는 비동기 통신 채널 8개를 단 한개의 IC로 설계하여 원가 절감 및 기능과 성능을 향상 시키도록 설계하였으며, 송수신 버퍼의 크기를 각각 256 바이트로 설계함으로써 고속의 통신을 가능하게 하였다. 또한 통신시 오동작을 방지하기 위해 디지털(Digital) 필터 및 첵섬(Check-sum) 로직을 설계하여 신뢰성을 향상시켰으며, 채널 먹스 로직을 설계하여 각 채널별 입/출력을 자유롭게 선택하도록 하여 통신 채널에 대한 입/출력 포트를 유연하게 사용할 수 있도록 설계하였다. 이와 같이 설계된 다채널 비동기 통신 IC를 ALTERA사의 Cyclone II Series EP2C35F672C8과 QuartusII V8.1을 이용하여 로직을 합성 및 시뮬레이션 하였다. QuartusII 시뮬레이션과 실험에서 성공적으로 수행되었으며, 설계된 IC의 우수성을 보이기 위해 비동기 통신 칩으로 많이 사용되고 있는 TI(Texas Instruments)사의 TL16C550A, ATMEL사의 ATmega128 범용 마이크로 콘트롤러와 수행시간 및 성능을 비교하여 본 논문에서 설계된 다채널 비동기 통신용 IC의 우수함을 확인하였다.

초미세입자 제거를 위한 고온용 나노 세라믹 필터 개발 (Development of Nano Ceramic Filter for the Removal of Ultra Fine Particles)

  • 김종원;안영철;이병권;정현재
    • 설비공학논문집
    • /
    • 제22권1호
    • /
    • pp.13-20
    • /
    • 2010
  • Airborne particulate matters have two modes of size distributions of coarse mode and fine mode. The coarse mode which is formed by break down mechanism of large particles has a peak around the $100\;{\mu}m$, and the fine mode formed by condensation and build up mechanism of evaporated vapors has a peak at several ${\mu}m$. The coarse mode particles can be removed easily by conventional collecting equipments such as a cyclone, an electrostatic precipitator, and a filter, however the fine mode particles can not be collected easily. Usually the fine mode particles are generated in the high temperature conditions especially through boilers and incinerators, so the high efficient and temperature filter is essential for the filtration. In this study, a nano ceramic filter for the removal of fine particles in the high temperature is developed and tested for several characteristics. The nano ceramic filter has double layer of micro and nano structure and the pressure drop and the filtration efficiency for $0.31\;{\mu}m$ at 3 cm/s are 15.45 mmAq, and 96.75%, respectively. The thermal conductivity is $0.038\;W/m{\cdot}K$, and the coefficient of water vapor permeability is $3.63\;g/m^2{\cdot}h{\cdot}mmHg$. It is considered that the sensible heat exchange rate is very poor because the low thermal conductivity but it has high potential to exchange latent heat.