• Title/Summary/Keyword: Micro-CYCLONE

Search Result 11, Processing Time 0.022 seconds

Numerical Analysis Study on Micro-plastic Particle behavior According to the Shape of Cyclone Separator (Cyclone separator의 형상에 따른 미세플라스틱 입자 거동 수치해석 연구)

  • Insun Kang;Wonjun Seo;Dongho Yu;Yeongshik Kim;Hyeungchul Kim;Seokyeon Im
    • Tribology and Lubricants
    • /
    • v.40 no.2
    • /
    • pp.61-66
    • /
    • 2024
  • Micro-plastics are synthetic high-differentiation chemicals of less than 5mm in size, and are deposited not only on the sea surface but also on the coast. If these micro-plastics are not properly separated from the sand, they can threaten marine ecosystems. Thus, in the present study, we aimed to apply cyclone separator to the micro-plastic retrieval in order to predict the movement of particles according to the formation of the cyclone separator by applying the centrifugal force of the particle in accordance with the rotational movement of the air. The cyclone separator has three shapes, the first one is a typical interconnected cyclone separator. The second is the horn form, except for the cylinder in a regular cyclone separator, and the third is a form that increases the horn's height twice in the second. The numerical analysis simulation of the Cyclone separator used the Fluent software package. The output speed of the Cyclone separator was 5 to 13m/s at 1m/s intervals. The simulated particles include sand, Styrofoam, PET, PP, and PU. Sand particles are assigned a fixed diameter of 2mm, while other particles have a diameter of 3mm. As a result of the analysis, the first form was not separated from plastic. The Styrofoam separation efficiency in the second showed its highest efficiency at 72.7% at 7m/s, and the efficiency decreased after 12m/s as the sand particles were mixed into the plastic attachment location. In the third form, the separation efficiency of Styrofoam at 12m/s was highest at 67.9%.

Numerical Simulation of the Mixing and Flow Characteristics in a Micro Cyclone Combustor (마이크로 사이클론 연소기의 혼합 및 유동특성에 관한 수치해석 연구)

  • Oh, Chang-Bo;Choi, Byung-il;Han, Yong-shik;Kim, Myung-bae;Hwang, Cheol-hong
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.1900-1905
    • /
    • 2007
  • A micro cyclone combustor was developed to be used as a heat source of thermoelectric power generator (TPG). The cyclone combustor was designed so that fuel and air were supplied to the combustion chamber separately. The mixing and flow characteristics in the combustor were investigated numerically. The global equivalence ratio (${\Phi}$), defined using the fuel and air flow rates, was introduced to examine the flow features of the combustor. The mixing of fuel and air inside the combustor could be well understood using the fuel concentration distribution. It was found that the weak recirculating zone was formed upper the fuel-supplying tube in case of ${\Phi}$ < 1.0. In addition, it was found that small regions that have a negative axial velocity exist near the fuel injection ports. It is assumed that these negative axial velocity regions can stabilize a flame inside the micro cyclone combustor.

  • PDF

Flame Stabilization Mechanism of a Micro Cyclone Combustor (마이크로 사이클론 연소기의 화염 안정화 기구)

  • Oh, Chang-Bo;Choi, Byung-Il;Han, Yong-Shik;Kim, Myung-Bae;Hwang, Cheol-Hong
    • 한국연소학회:학술대회논문집
    • /
    • 2007.05a
    • /
    • pp.139-144
    • /
    • 2007
  • A micro cyclone combustor was developed to be used as a component of mobile power generator (MPG). The cyclone combustor was designed so that fuel and air were supplied to the combustion chamber separately to prevent a flash-back. The flame shape stabilized inside the micro cyclone combustor was visualized experimentally and the flow field and the combustion characteristics of the combustor were investigated numerically. The global equivalence ratio (${\Phi}$), defined using the fuel and air flow rates, was introduced to examine the overall flow and flame features of the combustor. The flame stabilization mechanism could be well understood using the velocity distribution inside the combustor. For only non-reacting case, it was found that a weak recirculating zone was formed upper the fuel-supplying tube in case of ${\Phi}$ < 1.0. It was also found that small regions that have a negative axial velocity exist near the fuel injection ports for both of non-reacting and reacting case. It was identify that a flame front was stabilized at the negative axial velocity regions near the fuel injection ports.

  • PDF

Numerical Simulation of the Mixing and Flow Characteristics in a Micro Cyclone Combustor (마이크로 사이클론 연소기의 혼합 및 유동특성에 관한 수치해석 연구)

  • Choi, Byung-ll;Han, Yong-Shik;Kim, Myung-Bae;Hwang, Cheol-Hong;Oh, Chang-Bo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.12
    • /
    • pp.1042-1047
    • /
    • 2007
  • A micro cyclone combustor was developed to be used as a heat source of thermoelectric power generator (TPG). The cyclone combustor was designed so that fuel and air were supplied to the combustion chamber separately. The mixing and flow characteristics in the combustor were investigated numerically. The global equivalence ratio ($\Phi$), defined using the fuel and air flow rates, was introduced to examine the flow features of the combustor. The mixing of fuel and air inside the combustor could be well understood using the fuel concentration distribution. It was found that the weak recirculating zone was formed upper the fuel-supplying tube in case of ${\Phi}$<1.0. In addition, it was found that small regions that have a negative axial velocity exist near the fuel injection ports. It is assumed that these negative axial velocity regions can stabilize a flame inside the micro cyclone combustor.

Wet Deposition Fluxes of Ions Contributed by Cyclone-, Stationary Front- and Typhoon-associated Rains at the Southwestern Japan Coast

  • Toyonaga, Satoshi;Zhang, Daizhou
    • Asian Journal of Atmospheric Environment
    • /
    • v.10 no.2
    • /
    • pp.57-66
    • /
    • 2016
  • Wet deposition fluxes of ions at a coastal site in southwestern Japan in the period 1996-2003 were investigated to quantify the respective contributions of cyclone-, stationary front- and typhoon-associated rains. On average, the deposition fluxes of terrigenous-origin ions, nss-$SO_4{^{2-}}$, $NO_3{^-}$, $NH_4{^+}$ and nss-$Ca^{2+}$ were $37.6{\pm}7.3$, $16.3{\pm}4.2$, $19.0{\pm}3.4$ and $9.6{\pm}4.8meq\;m^{-2}yr^{-1}$, and those of $Na^+$ and $Cl^-$, the major ions in sea water, were $97.0{\pm}38.2$ and $115.2{\pm}48.2meq\;m^{-2}yr^{-1}$, respectively. Cyclone-associated rain constituted more than 50% of the fluxes of the terrigenous ions in almost all years. Stationary front-associated rain also contributed significantly, although the contribution was lower than the contribution by Cyclone-associated rain in almost all years. In particular, the wet deposition flux of nitrogen compounds of $NO_3{^-}$ and $NH_4{^+}$, which are important nutrients for micro-bioactivities in sea surface water, was dominated by cyclone-associated rain. Due to the extreme abundance of $Na^+$ and $Cl^-$ in the rainwater of typhoons, the fluxes of $Na^+$ and $Cl^-$ were contributed substantially by typhoons in years with typhoons' passage although cyclones were still the largest contributor to the fluxes. These results indicate the dominance of cyclones in the wet deposition to the East China Sea areas and the necessity to take rain types into account for a more accurate elucidation of the temporal and spatial variation of the wet deposition.

A STUDY ON SPACE ZONING BY COMPUTING IDLE-TIMES IN CONSTRUCTION PROCESSES

  • Sang-Min Park;Won-Suk Jang;Dong-Eun Lee
    • International conference on construction engineering and project management
    • /
    • 2013.01a
    • /
    • pp.509-512
    • /
    • 2013
  • An inappropriate space zoning plan causes the unnecessary transportation of construction material and equipment among work areas and increases the disorder of work space. Space zoning is an essential operation management technique which contributes to reduce the process and/or operation idle-time. This paper introduces a method that computes the idle-times between construction operations (or processes) by using Web-CYCLONE. It allows computing with idle-times that affect the construction productivity. Using the idle time between operations and between processes, it computes the optimal number of zones and finds the optimal combination of zones that minimize the idle times. The method contributes to minimize the idle times relative to the operation schedule using complete enumeration. This paper presents the system prototype in detail. A case study is presented to demonstrate the system and verifies the validity of the model. It allows a project manager to establish space zoning plan that effectively segregates a project into optimal number of construction zones and to assign the constrained resources (e.g., laborer, equipment).

  • PDF

Implementation of Digital CODEC for RFID Dual-band Reader system (RFID Dual-band 리더 시스템의 디지털 코덱 설계)

  • Sim, Jae-Hee;Lee, Yong-Joo;Lee, Yong-Surk
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.10A
    • /
    • pp.1015-1022
    • /
    • 2007
  • In this paper, dual-band digital codec for UHF(Ultra High Frequency) and MW(Micro Wave) is proposed for an RFID reader system. Most RFID systems have been supported only one protocol. But, There are many protocols of each bandwidth. Especially, UHF bandwidth which is widely used on the globe consists of A,B,C type, and more standards will be established. Recently, Since an interest about mobile RFID system is increasing, the RFID system with more than one protocol will be need. Therefore, this paper suggests a dual-band digital codec with UHF and MW bands for an RFID reader system. Standards used in this system are 18000-6C and 18000-4 standards. The digital codec is synthesize by the Quartus II compiler. Target device is EPC20Q240C8 which is family of CycloneII. Main Clock is 19.2MHz and elements of FPGA which is used for the system is 18,752.

Patent Technologies for Reducing Micro-Dust (미세먼지 저감을 위한 특허기술들)

  • Cho, Taejun;Kim, Tae-Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.2
    • /
    • pp.9-14
    • /
    • 2020
  • Four developed patents have applied for a new type of Composite Cyclone Scrubber followed by the previous research (Cho and Kim, 2017), including dust reducing fan with filters. Regarding target installation and maintenance cost, 64% reduction for investment costs (6.2 billion won vs. 17 billion won) compared to existing road pollution reduction system, while social benefit costs increase by 43% compared to existing road pollution reduction measures (72.6 billion won vs. 50.8 billion won). The composition of the device is an air blower type spiral guide vane, and an injection pressure collecting dust efficiency. A nozzle varies Injection angle and contact range, spray liquid species (waterworks, salty water). The proposed patent tests are circulation water Time-by-Time Spray and collected 41.4% more increased micro dust since the sprayed water meets contaminated gas due to the 45° degree colliding, which is 141% increased conventional dust collector. (Ratio of collection over 85%). As regards the source of collection liquid, circulated rainwater and well water, we expect a huge amount of energy and economically saved eco-friendly system in our patent. Finally, the guided vane and metal filter reduced over 90% micro-dust, while sprayed water cleans the vane and filters, resultantly minimizing the maintenance budget. The preliminary evaluations of the developed design make it possible to reduce not only cheaper maintenance budget due to the characteristic water spraying but the cost of water comes from mainly rain and underground.

The Design of Multi-channel Asynchronous Communication IC Using FPGA (FPGA를 이용한 다채널 비동기 통신용 IC 설계)

  • Ock, Seung-Kyu;Yang, Oh
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.1
    • /
    • pp.28-37
    • /
    • 2010
  • In this paper, the IC (Integrated Circuit) for multi-channel asynchronous communication was designed by using FPGA and VHDL language. The existing chips for asynchronous communication that has been used commercially are composed of one to two channels. Therefore, when communication system with two channels or more is made, the cost becomes high and it becomes complicated for communication system to be realized and also has very little buffer, load that is placed into Microprocessor increases heavily in case of high speed communication or transmission of high-capacity data. The designed IC was improved the function and performance of communication system and reduced costs by designing 8 asynchronous communication channels with only one IC, and it has the size of transmitter/receiver buffer with 256 bytes respectively and consequently high speed communication became possible. To detect errors between communications, it was designed with digital filter and check-sum logic and channel MUX logic so that the malfunction can be prevented and errors can be detected more easily and input/output port regarding each communication channel can be used flexibly and consequently the reliability of system was improved. It was composed and simulated logic of VHDL described by using Cyclone II Series EP2C35F672C8 and QuartusII V8.1 of ALTERA company. In order to show the performance of designed IC, the test was conducted successfully in QuartusII simulation and experiment and the excellency was compared with TL16C550A of TI (Texas Instrument) company and ATmegal28 general-purpose micro controller of ATMEL company that are used widely as chips for asynchronous communication.

Development of Nano Ceramic Filter for the Removal of Ultra Fine Particles (초미세입자 제거를 위한 고온용 나노 세라믹 필터 개발)

  • Kim, Jong-Won;Ahn, Young-Chull;Yi, Byeong-Kwon;Jeong, Hyeon-Jae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.1
    • /
    • pp.13-20
    • /
    • 2010
  • Airborne particulate matters have two modes of size distributions of coarse mode and fine mode. The coarse mode which is formed by break down mechanism of large particles has a peak around the $100\;{\mu}m$, and the fine mode formed by condensation and build up mechanism of evaporated vapors has a peak at several ${\mu}m$. The coarse mode particles can be removed easily by conventional collecting equipments such as a cyclone, an electrostatic precipitator, and a filter, however the fine mode particles can not be collected easily. Usually the fine mode particles are generated in the high temperature conditions especially through boilers and incinerators, so the high efficient and temperature filter is essential for the filtration. In this study, a nano ceramic filter for the removal of fine particles in the high temperature is developed and tested for several characteristics. The nano ceramic filter has double layer of micro and nano structure and the pressure drop and the filtration efficiency for $0.31\;{\mu}m$ at 3 cm/s are 15.45 mmAq, and 96.75%, respectively. The thermal conductivity is $0.038\;W/m{\cdot}K$, and the coefficient of water vapor permeability is $3.63\;g/m^2{\cdot}h{\cdot}mmHg$. It is considered that the sensible heat exchange rate is very poor because the low thermal conductivity but it has high potential to exchange latent heat.