• 제목/요약/키워드: Micro transformer

검색결과 38건 처리시간 0.024초

초소형 마이크로 압전변압기 제작 및 특성 분석 (Fabrication and Characteristic Analysis of Piezoelectric Micro-Transformer)

  • 김성곤;서영호;최두선;황경현
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.469-470
    • /
    • 2006
  • Piezoelectric transformers based on lead zirconate titanate(PZT) have been received considerable interest because of their wide potential applications in transformer, oscillator, resonance sensor, actuator, acoustic transducer, as well as active slider for hard disk drives. However, for the applications which need a small power supply such as thin and flat displays, micro-robot, micro-system, it is especially necessary to integrate the passive components because they typically need more than 2/3 of the space of the conventional circuit. So, we have fabricated the piezoelectric micro-transformer to supply energy for micro-systems using PZT thin films and MEMS technologies.

  • PDF

마이크로 압전변압기 제작 및 전기-기계적 특성 분석 (Fabrication and Electro-Mechanical Characteristic Analysis of Piezoelectric Micro-transformers)

  • 김성곤;서영호;황경현;최두선
    • 대한기계학회논문집B
    • /
    • 제32권3호
    • /
    • pp.231-234
    • /
    • 2008
  • For the applications which need a micro-power supply such as thin and flat displays, micro-robot, and micro-system, it is especially necessary to integrate the passive components because they typically need more than 2/3 of the space of the conventional circuit. Therefore, we have designed and fabricated a novel piezoelectric micro transformer using the PZT thin film and MEMS technologies for application to the energy supply device of the micro-systems. The dimensions of the micro-transformer is $1000{\mu}m\;{\times}\;400{\mu}m\;{\times}\;4.8{\mu}m$ $(length{\times}width{\times}thickness)$. The dynamic displacement of around $9.2{\pm}0.064{\mu}m$ was observed at 10 V. The dynamic displacement varied almost linearly with applied voltage. The average voltage gain (step-up ratio) was approximately 2.13 at the resonant frequency $(F_r=8.006KHz)$ and load resistance $(R_L)$ of 1 $M{\Omega}$.

Analysis of DC insulation and properties of epoxy/ceramic composites with nanosized ZnO/TiO2 fillers

  • Kwon, Jung-Hun;Kim, Yu-Min;Kang, Seong-Hwa;Kim, Pyung-Jung;Jung, Jong-Hoon;Lim, Kee-Joe
    • Journal of Ceramic Processing Research
    • /
    • 제13권spc2호
    • /
    • pp.332-335
    • /
    • 2012
  • A molded transformer is maintenance-free, which makes it unnecessary to replace the insulating material, like in an oil-filled transformer, because the epoxy, which is a molded insulating resin, does not suffer variations in its insulating performance for heat cycles over a long time, as compared to insulating oil. In spite of these advantages, a molded transformer may still be accessed by the user, which is not good in regards to reliability or noise compared to the oil transformers. In particular, a distrust exists regarding reliability due to the long-term insulating performance. These properties have been studied in regards to the improvement of epoxy composites and molded transformer insulation. There have nevertheless been insufficient investigations into the insulation properties of epoxy composites. In this study, it is a researching of the epoxy for insulating material. In order to prepare the specimens, a main resin, a hardener, an accelerator, and a nano/micro filler were used. Varying amounts of TiO2 and ZnO nano fillers were added to the epoxy mixture along with a fixed amount of micro silica. This paper presents the DC insulation breakdown test, thermal expansion coefficient, and thermal conductivity results for the manufactured specimens. From these results, it has been found that the insulating performance of nano/micro epoxy composites is improved as compared to plain molded transformer insulation, and that nano/micro epoxy composites contribute to the reliability and compactness of molded transformers.

압전특성 및 부하변화에 따른 압전트랜스포머의 전기적 특성 (Electrical Characteristics of the Piezoelectric Transformer as a Function of Piezoelectric Properties and Load Variations)

  • 민석규;윤광희;류주현
    • 한국전기전자재료학회논문지
    • /
    • 제14권4호
    • /
    • pp.289-296
    • /
    • 2001
  • The piezoelectric transformers of 2.0x10x48 ㎣ size were fabricated with PSN-PMN-PZT(T10 and PNW-PMN-PZT(T2) composition ceramics. Effects of micro structural and piezoelectric properties on the electrical characteristics of the piezoelectric transformers were investigated. Under the fixed output power of 6 W, temperature rise of T1 transformer at the optimum load was smaller than T2 one because of fine grain size effect. Voltage step-up ratio of T1 transformer showed higher value than T2 one T1 transformer showed an excellent properties with voltage step-up ratio of 12.41, efficiency of 95.23% and temperature rise of 7.2$^{\circ}C$ at 200㏀ load resistance. And also, T2 transformer showed an excellent properties with voltage step up ratio of 9.81, efficiency of 95.51% and temperature rise of 9$^{\circ}C$ at 150㏀ load resistance.

  • PDF

A Study on the Effective Downscaling Methodology for Design of a Micro Smart Grid Simulator

  • Ko, Yun-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권4호
    • /
    • pp.1425-1437
    • /
    • 2018
  • In this paper, a methodology was proposed to reduce the electrical level and spatial size of the smart grid with distributed generations (DGs) to a scale in which the electrical phenomena and control strategies for disturbances on the smart grid could be safely and freely experimented and observed. Based on the design methodology, a micro smart grid simulator with a substation transformer capacity of 190VA, voltage level of 19V, maximum breaking current of 20A and size of $2{\times}2m^2$ was designed by reducing the substation transformer capacity of 45MVA, voltage level of 23kV and area of $2{\times}2km^2$ of the smart grid to over one thousandth, and also reducing the maximum breaking current of 12kA of the smart grid to 1/600. It was verified that the proposed design methodology and designed micro smart grid simulator were very effective by identifying how all of the fault currents are limited to within the maximum breaking current of 20A, and by confirming that the maximum error between the fault currents obtained from the fault analysis method and the simulation method is within 1.8% through the EMTP-RV simulation results to the micro smart grid simulator model.

코어 기반의 마이크로 트랜스포머의 시뮬레이션 (Simulation for a Core based micro transformer)

  • 조세준;차두열;이재혁;장성필
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.123-124
    • /
    • 2009
  • 현재 전자기기의 소형화 추세에 맞물려 수동 소자중의 하나인 트랜스포머의 소형화가 큰 이슈가 되고 있다. 본 논문에서는 실리콘 웨이퍼 위에 트랜스포머와의 절연층을 삽입 하여 기판의 에디 커런트로 오는 멤돌이 손실의 영향을 줄이고 중간 코어를 투자율이 높은 퍼멀로이로 설계하여 1차 코일과 2차 코일의 턴수의 비를 기준으로 1:1 인 트랜스포머 (3/3, 5/5, 7/7)의 인덕턴스 및 상호 인덕턴스를 시뮬레이션 하였다. 트랜스포머의 최대 크기는 $1mm\;{\times}\;1.95mm$이고 선폭과 선간 간격, post의 높이는 각각 50um 이다. 이때 삽입 손실은 10GHz에서 0.12dB의 낮은 손실 값을 나타내었다.

  • PDF

온도 변화에 따른 Nano/Micro $SiO_2$ 혼합 Epoxy의 체적고유저항 특성

  • 김정식;정인범;류부형;김귀열;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 추계학술대회 논문집
    • /
    • pp.153-153
    • /
    • 2009
  • In the study the volume resistivity Characteristics of epoxy resin using nano and micro filler, nano and micro filler are made from insulating material epoxy resin using for transformer equipment and molding several devices as changing amount of addition of diameter 12 [nm] and 7 [${\mu}m$] $SiO_2$, we measured volume resistivity of nano and micro filler by High Resistance Meter(4329A). As the result of measurement, When is micro filler, the volume resistivity continuously increased over 80 [$^{\circ}$].

  • PDF

교류전압 보상 기능을 갖는 독립형 단상 연료전지 마이크로 소스 (Stand-Alone Type Single-Phase Fuel Cells Micro-Source with ac Voltage Compensation Capability)

  • 정영국
    • 전기학회논문지
    • /
    • 제58권1호
    • /
    • pp.35-41
    • /
    • 2009
  • This paper proposes a stand alone type single-phase fuel cells micro-source with a voltage sag compensator for compensating the ac output voltage variations (sag or swell) of micro-source. The proposed micro-source is consist of a PEM(polymer electrolyte membrane) fuel cells simulator, a full bridge de converter, a 60Hz PWM(pulse width modulation) VSI(voltage source inverter), and a voltage sag compensator. Voltage sag compensator is similar to the configuration of hybrid series active power filter, and it is directly connected to micro-source through the injection transformer. Compensation algorithm of a voltage sag compensator adopts a single phase p-q theory. Effectiveness of the proposed the system is verified by the PSIM(power electronics simulation tool) simulation in the steady state and transient state which the proposed system is able to simultaneously compensate the harmonic current and source voltage sag or swell.

AC Breakdown Property of Nano-$TiO_2$ and Micro-Silica filler Mixture of Epoxy Based Composites

  • Heo, J.;Jung, E.H.;Lim, K.J.;Kang, S.H.
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 추계학술대회 논문집
    • /
    • pp.150-150
    • /
    • 2009
  • In this paper, various kinds of epoxy based nanocomposites were made and AC breakdown properties of nano-$TiO_2$ and micro-silica filler mixture of epoxy based composites were studied by sphere to sphere electrode. Moreover, nano- and micro-filler combinations were adopted as an approach toward practical application of nanocomposite insulating materials. AC breakdown test was performed at room temperature $(25^{\circ}C)$, $80^{\circ}C$ and $100^{\circ}C$. The result shows breakdown strength about non-filled, nano-scale $TiO_2$, micro-scale silica and nano-$TiO_2$, micro-silica filled epoxy composites.

  • PDF

컴퓨터 그래픽스를 이용한 마이크로 배전 설비 관리 시스템 (A Micro Distribution Facility Management System Using Computer Graphics)

  • 김호용;고윤석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 전기.전자공학 학술대회 논문집
    • /
    • pp.874-878
    • /
    • 1988
  • In this paper, we constructed the distribution database using computer graphics which is supported by a microcomputer system. Using this micro computer system, we established the retrievement technique of the transformer and customer information. We showed visually the displaying technique for the separation and restoration of the distribution system fault zone.

  • PDF