• 제목/요약/키워드: Micro positioning system

검색결과 99건 처리시간 0.023초

초정밀 데스크탑 마이크로 NC 선반 개발 및 성능평가 (Development and Evaluation of Ultra-precision Desktop NC Turning Machine)

  • 노승국;박종권;박현덕;김양근
    • 한국생산제조학회지
    • /
    • 제22권4호
    • /
    • pp.747-754
    • /
    • 2013
  • This study introduces a recently designed desktop-sized NC turning system and its components. This machine is designed for the ultra-precise turning of parts with a diameter of 0.5-20 mm with minimum space usage for the machine. This study aims to achieve submicron-level accuracy of movements and good rigidity of the machine for precision machining using the desktop-sized machine. The components such as the main machine structure, air bearing servo spindle, and XZ stage with needle roller guides are designed, and the designed machine is built with a PC-based CNC controller. Its static and dynamic stiffness performances and positioning resolutions are tested. Through machining tests with single-crystal diamond tools, a form error less than $0.8{\mu}m$ and surface roughness (Ra) of $0.03{\mu}m$ for workpieces are obtained.

보행행태조사방법론의 변화와 모바일 빅데이터의 가능성 진단 연구 - 보행환경 분석연구 최근 사례를 중심으로 - (Changes in Measuring Methods of Walking Behavior and the Potentials of Mobile Big Data in Recent Walkability Researches)

  • 김현주;박소현;이선재
    • 대한건축학회논문집:계획계
    • /
    • 제35권1호
    • /
    • pp.19-28
    • /
    • 2019
  • The purpose of this study is to evaluate the walking behavior analysis methodology used in the previous studies, paying attention to the demand for empirical data collecting for urban and neighborhood planning. The preceding researches are divided into (1)Recording, (2) Surveys, (3)Statistical data, (4)Global positioning system (GPS) devices, and (5)Mobile Big Data analysis. Next, we analyze the precedent research and identify the changes of the walkability research. (1)being required empirical data on the actual walking and moving patterns of people, (2)beginning to be measured micro-walking behaviors such as actual route, walking facilities, detour, walking area. In addition, according to the trend of research, it is analyzed that the use of GPS device and the mobile big data are newly emerged. Finally, we analyze pedestrian data based on mobile big data in terms of 'application' and distinguishing it from existing survey methodology. We present the possibility of mobile big data. (1)Improvement of human, temporal and spatial constraints of data collection, (2)Improvement of inaccuracy of collected data, (3)Improvement of subjective intervention in data collection and preprocessing, (4)Expandability of walking environment research.

경량 모바일매핑시스템을 위한 도심지 내 MEMS 기반 IMU/GPS 통합센서(MTi-G) 특성 연구 (Study on MEMS based IMU & GPS Performance in Urban Area for Light-Weighted Mobile Mapping Systems)

  • 우희숙;권광석;김병국
    • 대한공간정보학회지
    • /
    • 제20권1호
    • /
    • pp.65-72
    • /
    • 2012
  • MEMS(Micro Electro Mechanical System)기술이 발전하여 작고 저렴한 IMU(Initial Measurement Unit)와 GPS(Global Positioning System)통합센서가 생산되어 다양한 분야에서 활용되고 있다. 본 연구에서는 모바일매핑시스템을 경량화하기 위해서 MEMS 기반 IMU/GPS 통합센서가 적합할 것으로 판단하고 XSens사 MEMS 기반 IMU/GPS 통합센서(MTi-G)의 특성 분석을 위한 실험을 수행하였다. 차량 대시보드에 통합센서를 고정하고 인천 송도 국제도시 도로구간과 터널구간을 주행하여 후처리 과정을 거치지 않은 좌표성과를 취득하였다. 전반적으로 위치결정 성과가 양호했지만 일부 구간(정지구간, 과속방지턱, 터널구간 등)에서 센서 특성, XKF(칼만필터) 특성 및 GPS 신호 수신환경 제한으로 인해 양호하지 못한 부분이 확인되었다. 실험결과 경량 모바일매핑시스템의 활용 가능성을 확인할 수 있었으며, 향후 다양한 GPS 신호 수신환경과 주행 조건에서의 실험과 보다 정밀한 정확도 분석이 요구된다.

소동물영상을 위한 마이크로 컴퓨터단층촬영장치 (Micro-CT System for Small Animal Imaging)

  • 남기용;김경우;김재희;손현화;유종현;강성훈;천권수;박성훈;윤권하
    • 한국의학물리학회지:의학물리
    • /
    • 제19권2호
    • /
    • pp.102-112
    • /
    • 2008
  • 살아있는 마우스 영상화를 목적으로 겐트리 회전형과 평판영상검출기를 기반으로 한 고분해능 마이크로 컴퓨터단층촬영 장치를 개발하였다. 이 장치는 주로, 마이크로 크기 광원사이즈를 갖는 X-선 광원, Csl (TI)과 결합된 평판형 상보성 금속산화 반도체 영상검출기(CMOS), 선형이송 카우치, 위치정보 엔코더와 결합된 겐트리, 그리고 영상데이터 처리를 위한 병렬처리 시스템으로 구성되었다. 본 장치는 겐트리 회전형으로 설계되었는데, 이는 살아있는 마우스를 CT 영상을 얻는데 있어서 마우스 움직임에 기인한 영상결점의 최소화에 유리하고 촬영하는 동안 쥐의 호흡마취시행에 여러 가지 장점을 갖기 때문이다. CT팬텀을 이용하여 개발한 CT장치의 공간해상도, 영상대비도 그리고 영상균일도를 평가하였다. 결과로써, 본 장치의 공간해상도는 MTF 곡선으로부터 10%에 해당하는 약 11.3 cycles/mm을 얻었으며, 마우스에 대한 방사선 피폭선량은 81.5 mGy의 결과를 얻었다. 저대비 영상팬텀을 이용한 영상실험에서 분해가능 최소영상대비차는 약 46 CT였다. $55{\times}55{\times}X100\;{\mu}^3$의 복셀(voxel) 크기에서 영상의 불균일도는 약 70 CT 임을 얻었다. 또한 본 연구에서는 살아있는 마우스의 몸체, 뼈, 그리고 간에 대한 영상 테스트 결과를 제시하였다.

  • PDF

Traffic Flow Sensing Using Wireless Signals

  • Duan, Xuting;Jiang, Hang;Tian, Daxin;Zhou, Jianshan;Zhou, Gang;E, Wenjuan;Sun, Yafu;Xia, Shudong
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제15권10호
    • /
    • pp.3858-3874
    • /
    • 2021
  • As an essential part of the urban transportation system, precise perception of the traffic flow parameters at the traffic signal intersection ensures traffic safety and fully improves the intersection's capacity. Traditional detection methods of road traffic flow parameter can be divided into the micro and the macro. The microscopic detection methods include geomagnetic induction coil technology, aerial detection technology based on the unmanned aerial vehicles (UAV) and camera video detection technology based on the fixed scene. The macroscopic detection methods include floating car data analysis technology. All the above methods have their advantages and disadvantages. Recently, indoor location methods based on wireless signals have attracted wide attention due to their applicability and low cost. This paper extends the wireless signal indoor location method to the outdoor intersection scene for traffic flow parameter estimation. In this paper, the detection scene is constructed at the intersection based on the received signal strength indication (RSSI) ranging technology extracted from the wireless signal. We extracted the RSSI data from the wireless signals sent to the road side unit (RSU) by the vehicle nodes, calibrated the RSSI ranging model, and finally obtained the traffic flow parameters of the intersection entrance road. We measured the average speed of traffic flow through multiple simulation experiments, the trajectory of traffic flow, and the spatiotemporal map at a single intersection inlet. Finally, we obtained the queue length of the inlet lane at the intersection. The simulation results of the experiment show that the RSSI ranging positioning method based on wireless signals can accurately estimate the traffic flow parameters at the intersection, which also provides a foundation for accurately estimating the traffic flow state in the future era of the Internet of Vehicles.

삼중헤드 SPECT에서 기하학적 보정 기법의 개발 (Development of Geometric Calibration Method for Triple Head Pinhole SPECT System)

  • 김중현;이재성;이원우;박소연;손지연;김유경;김상은;이동수
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제42권1호
    • /
    • pp.61-69
    • /
    • 2008
  • 목적: 일반적인 바늘구멍 조준기를 사용한 SPECT 시스템은 피사체를 확대시킬 수 있다는 장점이 있어 설치류와 같은 소동물 영상을 얻기에 적합하다. 그러나 몇 가지 기하학적 오차는 영상의 해상도를 크게 저하시킬 수 있으므로 이를 보정해주는 기법이 필요하다. 본 연구에서는 바늘구멍 조준기를 장착한 삼중 헤드 SPECT 시스템에서 간단한 기하학적 보정기법을 개발하고 이를 모형과 몇몇 설치류 영상에 대해 적용하여 기하학적 보정 효과를 검증하였다. 대상 및 방법: Trionix사의 TRIAD XLT9 SPECT시스템에 1.0 mm의 입구를 갖는 바늘구멍 조준기를 장착하고 실험하였다. 회전각도에 의존하는 기하학적 오차를 측정하기 위해 중앙에 위치시킨 점선원의 영상을 얻었다. 무게중심을 구하는 방법으로 점선원의 중심 위치를 찾아주었고 이 중심 위치를 이용하여 기하학적 오차를 보정하였다. 또한 입력해준 회전 반경과 실제 회전 반경의 차이를 보정하기 위해 종축 방향으로 서로 떨어져 있는 두 개의 점선원 영상을 얻었다. 기하학적 오차의 보정 기법을 검증하기 위해 점선원을 보정 전, 후에 각각 재구성하여 이를 비교하였다. 또한 열소반점 초소형 모형 및 몇몇 설치류 영상에 대해 SPECT 영상을 얻어 보정 효과를 검증하였다. 결과: 보정 전 기울어진 도넛 모양으로 보이던 점선원의 재구성 영상이 보정 후 완벽한 구 모양으로 얻어졌고 축방향의 해상도 역시 개선되었다. 열소반점 모형과 설치류 영상에서도 매우 높은 해상도의 영상을 얻을 수 있었다. 결론: 기하학적 오차에 의한 영상 왜곡 및 해상도의 저하 현상이 이 연구에서 개발된 하나 또는 두 개의 점선원을 이용한 간단한 보정 기법에 의해 크게 보정되었다.

고기동 환경에 적용 가능한 소형 GPS/MEMS IMU 통합항법 수신모듈 설계 (Design of a Compact GPS/MEMS IMU Integrated Navigation Receiver Module for High Dynamic Environment)

  • 정구용;박대영;김성민;이종혁
    • 한국항행학회논문지
    • /
    • 제25권1호
    • /
    • pp.68-77
    • /
    • 2021
  • 본 논문에서는 높은 동특성 환경에서 동작이 가능한 GPS/MEMS IMU 통합항법 수신모듈을 설계 및 제작하고, 그 결과를 확인하였다. 설계한 모듈은 RF 수신부, 관성측정부, 신호처리부, 상관기, 항법 S/W로 구성된다. RF 수신부는 저잡음증폭, 주파수 변환, 필터링, 자동이득조절 기능을 수행하고, 관성측정부는 3축 자이로스코프, 가속도계, 지자기센서가 적용된 MEMS급 IMU로부터 측정 데이터를 수집하여 항법S/W로 전달하는 인터페이스를 제공한다. 신호처리부 및 상관기는 FPGA 로직으로 구현하여 필터링 및 상관 값 계산을 수행하고, FPGA 내부 CPU를 사용하여 위성항법, 통합항법 S/W를 구현하였다. 제작된 모듈의 크기는 95.0 × 85.0 × 12.5 mm 이고, 무게는 110g을 확인하였으며, 동적성능 1200m/s, 가속도 10g의 환경에서 규격 이내의 항법정확도 성능을 확인하였다.

링크 공간평균속도 신뢰성 확보를 위한 프로브 차량 데이터 적정 수집주기 산정 연구 (Probe Vehicle Data Collecting Intervals for Completeness of Link-based Space Mean Speed Estimation)

  • 오창환;원민수;송태진
    • 한국ITS학회 논문지
    • /
    • 제19권5호
    • /
    • pp.70-81
    • /
    • 2020
  • GPS가 탑재된 차내 단말기, 스마트폰에서 방대하게 수집되는 초 단위 위치(위·경도) 데이터는 교통 분야에 다양하게 활용되고 있다. 이러한 데이터는 공공의 교통관련 의사결정자들과 교통서비스를 개발·제공하는 민간회사들에게 운전자들의 행태와 교통흐름을 미시적으로 파악할 수 있게 한다. 특히, 속도 데이터는 통행시간 예측에 주요한 정보로 활용되며, 해상도 높은 데이터 기반의 고차원 서비스 개발에 이용되고 있어 신뢰성있는 정보의 확보가 요구된다. 그럼에도 불구하고 링크별 속도 산출 시 각기 다른 저장, 수집주기 등을 기준으로 사용하고 있어 정보 활용에 있어 신뢰성을 담보하기 어렵다. 본 연구의 목적은 차내 단말기를 장착한 프로브차량 데이터를 수집해 링크 공간평균속도를 산출하고 동일 구간 및 시간대의 영상기반 공간평균속도와 비교분석을 통해 오차율을 도출하는 것이다. 수집주기와 실제 속도 상황에 따른 오차율을 분석한 결과 8초 이내 수집주기에서 95% 신뢰수준을 보였으며 이를 공간평균속도 산출 시 신뢰성확보를 위한 적정 수집 주기로 제안했다. 해당 결과는 향후 커넥티드 환경에서 수집될 핵심 정보들의 신뢰성 확보와 서비스 개발 시 기초 정보로 활용될 것으로 기대해본다.

고선량률 강내 근접치료에 사용되는 Ir-192 선원과 치료계획 시스템간의 계산선량 비교 (Dose Comparison of Treatment Plans Using Different Ir-192 Sources and Treatment Planning Systems for Intracavitary HDR Brachytherapy)

  • 박동욱;김영석;박성호;최은경;김종훈;이상욱;송시열;안승도;노영주
    • 한국의학물리학회지:의학물리
    • /
    • 제20권1호
    • /
    • pp.1-6
    • /
    • 2009
  • 본 연구에서는 동일한 시스템 내에서 기하학적 모델이 다른 Ir-192 선원을 사용한 두 치료계획의 선량차이를 비교하고, 치료계획시스템 간 차이에 대해서 동일 선원을 사용할 경우 제조사별 프로그램 및 선원들의 위치결정방법에 따른 선량 계산결과의 차이와 그 영향을 평가하고자 하였다. 이를 위해 2007년 10월에서 2008년 1월까지 본 원에서 Ovoids와 Tandem을 이용하여 자궁경부암 근접치료를 시행 받았던 10명 환자의 치료계획에 대하여 적용하였다. 실제 환자에 적용된 치료계획을 바탕으로 평가한 결과 선원의 기하학적 특성의 차이로 발생할 수 있는 임상의 영향이 1.43% 이내로 전체 조사시간의 차이 및 B-point, 방광과 직장에서의 선량차이는 평균 $-0.91{\pm}0.09%$, $-0.27{\pm}0.07%$, $0.88{\pm}0.37%$, $0.22{\pm}0.39%$로 나타났다. 각 제조사별 프로그램에서 계산된 선량값들 간의 차이는 A-point, B-point, 방광 및 직장에서 평균 각각 $-0.22{\pm}0.42%$, $-0.25{\pm}0.29%$, $-0.23{\pm}0.63%$, $-0.17{\pm}0.76%$로 나타났다. 두 시스템에서 서로 다른 프로그램과 위치결정방법을 이용하여 계산한 각 치료계획의 선량분포 차이는 A-point, B-point, 방광 및 직장에서 평균 $-0.61{\pm}0.59%$, $-0.77{\pm}0.45%$, $-0.72{\pm}1.70%$, $0.35{\pm}2.82%$로 나타났다. 제조사별 프로그램상의 차이는 대체로 1.68% 이내, 직교좌표 상에서 선원의 경로좌표를 결정하는 방법론적인 차이에서는 치료계획자의 주관적인 판단이 더해져 최대 5.87% 가량의 선량계산결과 차이가 발생할 수 있음을 알 수 있었다. 또한 이러한 선원의 위치차이는 주로 환자의 AP방향에 위치한 직장과 방광의 선량에 더욱 민감하게 반영되었다.

  • PDF