• 제목/요약/키워드: Micro plasma

검색결과 507건 처리시간 0.021초

헤마토크릿에 따른 혈액의 유변학적 특성 변화 (Effect of hematocrit on hemorheological characteristics of blood flow in a microtube)

  • 지호성;이정엽;이상준
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2006년도 추계학술대회 논문집
    • /
    • pp.111-112
    • /
    • 2006
  • In order to investigate flow characteristics of blood flow in a micro tube ($100{\mu}m$ in diameter) according to hematocrit, in-vitro experiments were carried out using a micro-PIV technique. The micro-PIV system consists of a microscope, a 2 head Nd:YAG laser, a 12 bit cooled CCD camera and a delay generator. Blood was supplied into the micro tube using a syringe pump. Hematocrit of blood was controlled to be 20%, 30% and 40%. The blood flow has a cell free layer near the tube wall and its thickness was changed with increasing the flow rate and hematocrit. The hemorheological characteristics such as shear rate and viscosity were evaluated using the velocity field data measured. As the flow rate increased, the blunt velocity profile in the tube center was sharpened. The viscosity of blood was rapidly increased with decreasing shear rate, especially in the region of low shear rate, changing RBC rheological properties. The variation of velocity profile and blood viscosity shows typical characteristics of Non-Newtonian fluids. On the basis of inflection points, the cell free layer and two-phase flow consisting of plasma and suspensions including RBCs were clearly discriminated.

  • PDF

대기압 저온 플라스마를 이용한 산화막 및 고분자 재료의 표면개질 (Surface Modification of Conductive Oxide films and Polymer Materials Employing Atmospheric Cold Plasma Surface Modification of Conductive Oxide films and Polymer Materials Employing Atmospheric Cold Plasma)

  • 이봉주;이현규;김창석;이경섭;김형곤;장헌
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 센서 박막재료
    • /
    • pp.32-34
    • /
    • 2001
  • we have quantitatively investigated the possibility of feeding oxygen radical in air environment. The oxygen radical generation from the plasma was verified and its efficiency was found to be dependent on the cathode material by the analysis with optical emission spectroscopy as well as by the quartz crystal micro-balance method.

  • PDF

백미(白米)와 교맥분(蕎麥粉) 혼식(混食)의 영양가개선(營養價改善)에 대(對)한 연구(硏究) (4) - 백미(白米)와 교맥분(蕎麥粉) 혼합사료(混合飼料)의 사육(飼育)한 흰쥐의 Growth Gain과 혈장중(血漿中)의 Branch-Amino Acid Level에 대(對)하여 - (Improving the Nutritional Value of Mixed Diet of Rice and Buckwheat (4) - Growth Gain and the Level of Branch-Amino Acids in Plasma of Rats Fed on Rice Diet Adding Buckwheat -)

  • 이숙희;이현기
    • 한국식품영양과학회지
    • /
    • 제3권1호
    • /
    • pp.7-11
    • /
    • 1974
  • Wistar Strain male rats were divided into four different diet groups and the control group was fed on seven percent casein diet (C), the second with a mixture of 80% of rice and 20% of buckwheat (RW), the third with rice only (R), and the fourth with a mixture of rice and buckwheat of equal nitrogen level (RWS). Each diet group consisted of six rats was fed for three weeks by the adlibitum feeding method. The results of the experiment, i, e, the growth gain and change in the level of branch-amino acids in the plasma determined by the micro-bioassay method were as follows. 1. The group C showed the largest growth gain and the rest did in the order of RW group, R group, and RWS group. 2. It was shown that rats fed on diet of higher protein score tend to have higher level of free branch-amino acids in the plasma. 3. Thus, the protein score may be estimated based on the level of the free branch-amino acids in the plasma.

  • PDF

다공성 금속 샤워헤드가 적용된 상압플라즈마 화학기상증착법을 이용한 저온 다결정 실리콘 증착 공정 (Low Temperature Polycrystalline Silicon Deposition by Atmospheric Pressure Plasma Enhanced CVD Using Metal Foam Showerhead)

  • 박형규;송창훈;오훈정;백승재
    • 한국전기전자재료학회논문지
    • /
    • 제33권5호
    • /
    • pp.344-349
    • /
    • 2020
  • Modern thin film deposition processes require high deposition rates, low costs, and high-quality films. Atmospheric pressure plasma-enhanced chemical vapor deposition (AP-PECVD) meets these requirements. AP-PECVD causes little damage on thin film deposition surfaces compared to conventional PECVD. Moreover, a higher deposition rate is expected due to the surface heating effect of atomic hydrogens in AP-PECVD. In this study, polycrystalline silicon thin film was deposited at a low temperature of 100℃ and then AP-PECVD experiments were performed with various plasma powers and hydrogen gas flow rates. A deposition rate of 15.2 nm/s was obtained at the VHF power of 400 W. In addition, a metal foam showerhead was employed for uniform gas supply, which provided a significant improvement in the thickness uniformity.

Plasma Textured Glass Surface Morphologies for Amorphous Silicon Thin Film Solar Cells-A review

  • Hussain, Shahzada Qamar;Balaji, Nagarajan;Kim, Sunbo;Raja, ayapal;Ahn, Shihyun;Park, Hyeongsik;Le, Anh Huy Tuan;Kang, Junyoung;Yi, Junsin;Razaq, Aamir
    • Transactions on Electrical and Electronic Materials
    • /
    • 제17권2호
    • /
    • pp.98-103
    • /
    • 2016
  • The surface morphology of the front transparent conductive oxide (TCO) films plays a vital role in amorphous silicon thin film solar cells (a-Si TFSCs) due to their high transparency, conductivity and excellent light scattering properties. Recently, plasma textured glass surface morphologies received much attention for light trapping in a-Si TFSCs. We report various plasma textured glass surface morphologies for the high efficiency of a-Si TFSCs. Plasma textured glass surface morphologies showed high rms roughness, haze ratio with micro- and nano size surface features and are proposed for future high efficiency of a-Si TFSCs.

Microstructures and Mechanical Properties of Pressureless and Spark Plasma Sintered ZrO2(3 mol%Y2O3) Bodies

  • Shin, Na-Young;Han, Jae-Kil;Lee, Hae-Hyoung;Lee, Byong-Taek
    • 한국세라믹학회지
    • /
    • 제42권2호
    • /
    • pp.140-144
    • /
    • 2005
  • The microstructures and mechanical properties of Tetragonal Zirconia Polycrystals (TZP) sintered bodies, which made by pressureless and spark plasma sintering techniques, were investigated using XRD, SEM, and TEM techniques. In the spark plasma sintered samples, the TZP grains were equiaxed type including many sub-grain boundaries regardless of sintering conditions. The biaxial strength of TZP having an average of 80 nm grains in diameter was high in value with 1025 MPa, but fracture toughness showed a low value due to the absence of a fracture toughening mechanism such as transformation toughening. In the Pressureless Sintered (PLSed) samples, the grain size of TZP was strongly dependent on the sintering temperature; i.e., it gradually increased as the sintering temperature increased. The value of fracture toughness increased as the grain size increased by the stress-induced phase transformation and Borne crack deflection.

기계적 밀링과 플라즈마 활성 소결법에 의한 TiB2 분산 Cu기 복합재료 제조 (Synthesis of TiB2 Dispersed Cu Matrix Composite Material by the Combination of the Mechanical Milling and Plasma Activated Sintering Process)

  • 김경주;이길근;박익민
    • 한국분말재료학회지
    • /
    • 제14권5호
    • /
    • pp.292-297
    • /
    • 2007
  • The present study was focused on the synthesis of a $TiB_2$ dispersed copper matrix composite material by the combination of the mechanical milling and plasma activated sintering processes. The $Cu/TiB_2$ mixed powder was prepared by the combination of the mechanical milling and reduction processes using the copper oxide and titanium diboride powder as the raw material. The synthesized $Cu/TiB_2$ mixed powder was sintered by the plasma activated sintering process. The hardness and electric conductivity of the sintered bodies were measured using micro vickers hardness and four probe method, respectively. The relative density of $Cu/TiB_2$ composite material sintered at $800^{\circ}C$ showed about 98% of theoretical density. The $Cu-1vol%TiB_2$ composite material has a hardness of about 130Hv and an electric conductivity of about 85% IACS. The hardness and electric conductivity of $Cu-3vol%TiB_2$ composite material were about 140 Hv and about 45% IACS, respectively.

The Effect of Uni-nanoadditive Manufactured Using RF Plasma Processing on Core-shell Structure in MLCC

  • Song, Soon-Mo;Kim, Hyo-Sub;Park, Kum-Jin;Sohn, Sung-Bum;Kim, Young-Tae;Hur, Kang-Heon
    • 한국세라믹학회지
    • /
    • 제46권2호
    • /
    • pp.131-136
    • /
    • 2009
  • Radio frequency (RF) plasma treatment is studied for the size reduction and the spheroidization of coarse particles to change them into nano-sized powders of spherical shape in MLCC fields. The uni-nanoadditives manufactured by RF plasma processing for high dispersion have been investigated for the effect on core-shell structure in dielectrics of MLCC. Microstructures have been characterized using scanning electron microscope (SEM), transmission electron microscope (TEM) and Electron Probe Micro Analyzer (EPMA). We compared the distribution of core-shell grains between specimens manufactured using uni-nanoadditive and using mixed additive. In addition, the uniformity of rare earth elements in the core-shell structured grains was analyzed. It was shown, from TEM observations, that the sintered specimen manufactured using uni-nanoadditives had more dense small grains with well-developed core-shell structure than the specimen using mixed additives, which had a homogeneous microstructure without abnormal grain growth and shows broad temperature coefficient of capacitance (TCC) curves in all temperature ranges because of well dispersed additives.

산화막 식각 기구 연구를 위한 QMF Ion Beam 장치의 제작 (QMF Ion Beam System Development for Oxide Etching Mechanism Study)

  • 주정훈
    • 한국표면공학회지
    • /
    • 제37권4호
    • /
    • pp.220-225
    • /
    • 2004
  • A new ion beam extraction system is designed using a simple ion mass filter and a micro mass balance and a QMS based detecting system. A quadrupole Mass Filter is used for selective ion beam formation from inductively coupled high density plasma sources with appropriate electrostatic lens and final analyzing QMS. Also a quartz crystal microbalance is set between a QMF and a QMS to measure the etching and polymerization rate of the mass selected ion beam. An inductively coupled plasma was used as a ion/radical source which had an electron temperature of 4-8 eV and electron density of $4${\times}$10^{11}$#/㎤. A computer interfaced system through 12bit AD-DA board can control the pass ion mass of the qmf by setting RF/DC voltage ratio applied to the quadrupoles so that time modulation of pass ion's mass is possible. So the direct measurements of ion - surface chemistry can be possible in a resolution of $1\AA$/sec based on the qcm's sensitivity. A full set of driving software and hardware setting is successfully carried out to get fundamental plasma information of the ICP source and analysed $Ar^{+}$ beam was detected at the $2^{nd}$ QMS.

The Effects of Gas Compositions During Post Nitriding on the AISI 316L Stainless Steel after Plasma Carburizing

  • Lee, Insup
    • 한국표면공학회지
    • /
    • 제48권6호
    • /
    • pp.269-274
    • /
    • 2015
  • In this experiment, post-nitriding treatment was performed at $400^{\circ}C$ on AISI 316 stainless steel which was plasma carburized previously at $430^{\circ}C$ for 15 hours. Plasma nitriding was implemented on AISI 316 stainless steel at various gas compositions (25% $N_2$, 50% $N_2$ and 75% $N_2$) for 4 hours. Additionally, during post nitriding Ar gas was used with $H_2$ and $N_2$ to observe the improvement of surface properties. After treatment, the behavior of the hybrid layer was investigated by optical microscopy, X-ray diffraction, and micro-hardness testing. Potentiodynamic polarization test was also used to evaluate the corrosion resistance of the samples. Meanwhile, it was found that the surface hardness increased with increasing the nitrogen gas content. Also small percentage of Ar gas was introduced in the post nitriding process which improved the hardness of the hardened layer but reduced the corrosion resistance compared with the carburized sample. The experiment revealed that AISI 316L stainless steel showed better hardness and excellent corrosion resistance compared with the carburized sample, when 75% $N_2$ gas was used during the post nitriding treatment. Also addition of Ar gas during post nitriding treatment degraded the corrosion resistance of the sample compared with the carburized sample.