• 제목/요약/키워드: Micro focus X-ray CT system

검색결과 6건 처리시간 0.023초

소형 동물의 생체 촬영을 위한 고해상도 Micro-CT 시스템의 개발 (Development of High Resolution Micro-CT System for In Vivo Small Animal Imaging)

  • 박정진;이수열;조민형
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권1호
    • /
    • pp.95-101
    • /
    • 2007
  • Recently, small-animal imaging technology has been rapidly developed for longitudinal screening of laboratory animals such as mice and rats. One of newly developed imaging modalities for small animals is an x-ray micro-CT (computed tomography). We have developed two types of x-ray micro-CT systems for small animal imaging. Both systems use flat-panel x-ray detectors and micro-focus x-ray sources to obtain high spatial resolution of $10{\mu}m$. In spite of the relatively large field-of-view (FOV) of flat-panel detectors, the spatial resolution in the whole-body imaging of rats should be sacrificed down to the order of $100{\mu}m$ due to the limited number of x-ray detector pixels. Though the spatial resolution of cone-beam CTs can be improved by moving an object toward an x-ray source, the FOV should be reduced and the object size is also limited. To overcome the limitation of the object size and resolution, we introduce zoom-in micro-tomography for high-resolution imaging of a local region-of-interest (ROI) inside a large object. For zoom-in imaging, we use two kinds of projection data in combination, one from a full FOV scan of the whole object and the other from a limited FOV scan of the ROI. Both of our micro-CT systems have zoom-in micro-tomography capability. One of both is a micro-CT system with a fixed gantry mounted with an x-ray source and a detector. An imaged object is laid on a rotating table between a source and a detector. The other micro-CT system has a rotating gantry with a fixed object table, which makes whole scans without rotating an object. In this paper, we report the results of in vivo small animal study using the developed micro-CTs.

소 동물 촬영을 위한 Micro-CT의 개발 (Development of a Micro-CT System for Small Animal Imaging)

  • Sang Chul Lee;Ho Kyung Kim;In Kon Chun;Myung Hye Cho;Min Hyoung Cho;Soo Yeol Lee
    • 대한의용생체공학회:의공학회지
    • /
    • 제25권2호
    • /
    • pp.97-102
    • /
    • 2004
  • 소 동물 촬영에 이용될 수 있는 고해상도의 x-선 cone-beam micro computed tomography (micro-CT) 시스템을 개발하였다 Micro-CT 시스템은 120${\times}$120 mm2 의 2차원 평판 x-선 감지기, micro-focus x-선 발생장치, 주사 기구부, 병렬처리 영상 재구성 시스템으로 이루어져 있다. 개발된 시스템의 성능을 평가하기 위해 대조도와 공간해상도를 측정하였다. 대조도 실험에서는 95 mGy 에서 36 CT-번호를 구별할 수 있음을 확인하였고, 공간 해상도 실험에서는 14 lp/mm 의 성능을 확인하였다. 소 동물 촬영 결과로 실험용 쥐의 대퇴부, 심장 그리고 복부 동맥 혈관을 촬영한 경상을 제시하였다. 개발된 micro-CT 시스템은 소 동물을 이용한 생명공학 분야 연구에 널리 이용될 수 있을 것으로 기대된다.

3차원 X-ray 단층 화상을 이용한 스카른 광석의 정량분석 연구 (Quantitative Analysis of Skarn Ore Using 3D Images of X-ray Computed Tomography)

  • 정미희;조상호;정수복;김영훈;박재구
    • 한국광물학회지
    • /
    • 제23권3호
    • /
    • pp.211-217
    • /
    • 2010
  • 스카른 Zn-Pb-Cu 복합광석을 구성하는 주요 구성 광물의 정량분석을 목적으로, 마이크로 포커스 X-ray 단층촬영 장비를 이용한 스카른 복합광석의 3차원 비파괴검사를 수행하였다. X-ray 단층화상의 화상결함을 감소시키고자 제안된 화상보정법을 이용하여 화상들을 보정한 후에 3차원으로 재구성하였다. 주사전자현미경(SEM)에 의한 표면분석과 보정된 X-ray 단층화상을 비교하여 주요광물에 대한 CT 값의 범위를 결정하였다. 재구성화상 내 전체 광물의 체적비율을 분석한 결과, 황화광물 20.5%, 맥석광물 79.5%로 평가되었다. X-ray 3차원 단층화상 정량분석법은 광석 내 유용광물의 부존형상과 회수율 분석에 유용하게 적용될 것으로 기대된다.

다공성 칼슘포스파이트에 대한 파괴분석 (Numerical analysis of fracture mechanisms for porous calcium phosphate)

  • 박진홍;배지용;심재범;전인수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.1301-1302
    • /
    • 2008
  • In this study, the fracture strength for fracture mechanism porous calcium phosphate made from sintered with ${\beta}$-tricalcium phosphate obtained by wet precipitation procedure is analyzed using finite element method and experiment measurement. First, three $3{\times}3{\times}3mm^3$ and $5{\times}5{\times}5mm^3$ specimens are prepared and tomographic images of one $5{\times}5{\times}5mm^3$ specimen are obtained by micro focus X-ray CT. The compression tests using the specimens are carried out to measure the elastic modulus and fracture strength to analyze the fracture mechanism of porous calcium phosphate specimen. The tomographic images are reconstructed by 3D reconstruction program. The finite elements are directly built up in the reconstructed specimen. The numerical simulation for the compression tests is performed using the element. The mechanism of calcium phosphate of simulation are obtained by the compression tests using there cylindric specimen of height 19.5 mm and diameter 10 mm. From the results, the applicability of porous calcium phosphate is evaluated to care fracture and vacant bone of a patient as the reinforcement material.

  • PDF

닫힌 셀 구조 Al 발포 재료의 압축 거동에 대한 수치해석 (Numerical Analysis on the compressive behavior of closed-cell Al foam)

  • 전인수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.1663-1666
    • /
    • 2007
  • The finite element method is applied to analyze the deformation mechanisms in the closed-cell Al foam under the compression. The modeling of the real cellular structure proceeds with the concept of the reverse engineering. First of all, the small, $10{\times}\;10{\times}\;10mm^3$ sized specimens of the closed-cell Al foam are prepared. The micro focus X-ray CTsystem of SHIMADZU Corp. is used to scan the full structures of the specimens. The scanned structures are converted to the geometric surfaces and solids through the software for 3-D scan data processing, RapidFormTMof INUS Tech. Inc. Then the solid meshes are directly generated on the converted geometric solids for the finite element analysis. The large elastic-plastic deformation and 3-D contact problems for the Al cellular material are considered. The clear and successful analysis for the deformation mechanisms in the closed-cell Al foam is carried out through the comparison of the numerical results in this research with the referred experimental ones.

  • PDF

동적하중 하에서 석회암의 변형 및 파괴거동에 관한 실험적 연구 (Experimental Study on Deformation and Failure Behavior of Limestones under Dynamic Loadings)

  • 강명수;강형민;김승곤;천대성;;조상호
    • 터널과지하공간
    • /
    • 제22권5호
    • /
    • pp.339-345
    • /
    • 2012
  • 동적하중 하에서 암석의 변형거동 및 파괴강도는 발파, 지진 또는 암반돌출의 지진동에 의한 지하구조물의 안정해석에 중요하다. 본 연구에서는 스플릿 홉킨슨 압력봉(SHPB) 충격실험시스템을 석회암시료의 일축압축시험과 압열인장시험에 적용하여 고변형률과 동적강도 평가를 수행하였다. 충격봉의 발사속도를 제어하여 파괴강도 이하 동적응력 상태에서의 석회암시료의 동적응력-변형거동을 분석하였다. 시료 내 파괴여부 및 파괴양상을 파악하기 위하여 Micro-focus X-ray 단층촬영을 수행하였다. 동적 압축강도 실험결과, 석회암시료의 동적압축강도는 변형율속도 의존성을 보였으며, 동적 압축파괴강도는 140 MPa 이상으로 평가되었다. 동적 압열 인장 실험결과, 석회암시료의 동적 압열인장강도는 21 MPa 이상으로 정적 압열인장강도보다 3배 이상 높은 것으로 평가되었다.