• Title/Summary/Keyword: Micro chamber

Search Result 242, Processing Time 0.025 seconds

Numerical Study of Hydrogen/Air Combustion in Combustion Chamber of Ultra Micro Gas Turbine by Change of Flow Rate and Equivalence Ratio (공급 유량 및 당량비 변화에 따른 초소형 가스터빈 연소실 내 수소/공기 연소의 수치해석 연구)

  • Kwon, Kilsung;Hwang, Yu Hyeon;Kang, Ho;Kim, Daejoong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.2
    • /
    • pp.103-109
    • /
    • 2013
  • In this study, we performed a numerical study of hydrogen/air combustion in the combustion chamber of an ultra micro gas turbine. The supply flow rate and equivalence ratio are used as variables, and the commercial computational fluid dynamic program (STAR-CCM) is used for the numerical study of the combustion. The flow rate significantly affects the flame position, flame temperature, and pressure ratio between the inlet and the outlet. The flame position is close to the outlet in the combustion chamber, and the flame temperature and pressure ratio monotonously increases with the supply flow rate. The change in the equivalence ratio does not affect the flame position. The maximum flame temperature occurs under stoichiometric conditions.

The Development of Micro Wiring System for Micro Active Endoscope (박막 공정을 이용한 초소형 내시경의 MicroWiring System의 개발)

  • Jung, Seok;Chang, Jun-Keun;Han, Dong-Chul
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.362-365
    • /
    • 1997
  • In the field of Micro-Mechanics, it has been known diffcult to integrate the micro-machine with sensor and source line for the conventional copper line cnanot be used in compact and small size. We developed a system to make thethin copper film as a connect line on the poyurethane pipe (2mm in diameter) by the evaporation technique. This system consists of an evaporation chamber two long branches, substrate hoider and a Linear-Rotary motion feed feedthrough. The results showed that thin copper film coated polyurethanc pipe could be applied th the small medical devices such as the micro active endoscope.

  • PDF

A Study on the Rotordynamic Characteristics of the Micro Turbo Generator (터보 방식으로 구동되는 마이크로 파워 시스템의 회전체 동역학적 특성에 관한 연구)

  • Ryu, Keun;Lee, Yong-Bok;Lee, Byoung-Su;Kim, Chang-Ho
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.109-115
    • /
    • 2004
  • The micro turbo generator is new portable power source based on the Brayton cycle, which consists of a compressor, a turbine, a generator, and a combustion chamber. In this paper, the thermodynamic analysis was performed to find the required condition for hundreds watts power in the micro turbo generator, and also the rotordynamic stability was predicted using the numerical analysis of air foil bearings which support the micro turbo generator. By experimental works, the rotordynamic stability of the micro turbo generator with foil bearings was verified. While various transient dynamic situation, the micro turbo generator had stable performances. From the result, it was demonstrated that air foil bearings could be adapted to the micro turbo generator as a excellent lubrication element.

  • PDF

Status Change Monitoring of Semiconductor Plasma Process Equipment (주파수 도메인 반사파 측정법을 이용한 플라즈마 공정장비 상태변화 연구)

  • Yunsang Lee;Sang Jeen Hong
    • Journal of the Semiconductor & Display Technology
    • /
    • v.23 no.1
    • /
    • pp.52-55
    • /
    • 2024
  • In this paper, a state change study was conducted through Frequency Domain Reflectometry (FDR) technology for the process chamber of plasma equipment for semiconductor manufacturing. In the experiment, by direct connecting the network analyzer to the RF matcher input of the 300 mm plasma enhanced chemical vapor deposition (PECVD) chamber, S11 was measured in a situation where plasma was not applied, and the frequency domain reacting to the chamber state change was searched. Response factors to changes in the status, such as temperature, spacing of the heating chuck, internal pressure difference, and process gas supply state were confirmed. Through this, the frequency domain in which a change in the reflection value was detected through repeated experiments. The reliability of the measured micro-displacement was verified through reproducibility experiments.

  • PDF

Characteristic Study of Micro-Nozzles according to the Ratios of Nozzle Expansion and Specific heats in low vacuum condition (저진공상태에서 노즐 팽창비와 비열비에 따른 마이크로 노즐의 특성 연구)

  • Kim, Youn-Ho;Jung, Sung-Chul;Huh, Hwan-Il
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.249-252
    • /
    • 2006
  • We conducted the experiment to analyze characteristics of micro-nozzle using different cold gas under two different nozzle expansion ratios in low vacuum condition. We measured thrust and chamber pressure and mass flow rate under low vacuum condition, and then compared them with those in ambient pressure.

  • PDF

Feasibility Study of the microDiamond Detector for Measurement of Small Field Photon Beam (광자선 소조사면 선량측정을 위한 microDiamond 검출기의 유용성 고찰)

  • Lee, Chang Yeol;Kim, Woo Chul;Kim, Hun Jeong;Ji, Young Hoon;Kim, Kum Bae;Lee, Sang Hoon;Min, Chul Kee;Jo, Gwang Hwan;Shin, Dong Oh;Kim, Seong Hoon;Huh, Hyun Do
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.255-263
    • /
    • 2014
  • The dosimetry of very small fields is challenging for several reasons including a lack of lateral electronic equilibrium, large dose gradients, and the size of detector in respect to the field size. The objective of this work was to evaluate the suitability of a new commercial synthetic diamond detector, namely, the PTW 60019 microDiamond, for the small field dosimetry in cyberknife photon beams of 6 different collimator size (from 5 mm to 30 mm). Measurements included dose linearity, dose rate dependence, output factors (OF), percentage depth doses (PDD) and off center ratio (OCR). The results were compared to those of pinpoint ionization chamber, diamond detector, microLion liquid Ionization chamber and diode detector. The dose linearity results for the microDiamond detector showed good linearly proportional to dose. The microDiamond detector showed little dose rate dependency throughout the range of 100~600 MU/min, while microLion liquid Ionization chamber showed a significant discrepancy of approximately 5.8%. The OF measured with microDiamond detector agreed within 3.8% with those measured with diode. PDD curves measured with silicon diode and diamond detector agreed well for all the field sizes. In particular, slightly sharper penumbras are obtained by the microDiamond detector, indicating a good spatial resolution. The results obtained confirm that the new PTW 60019 microDiamond detector is suitable candidate for application in small radiation fields dosimetry.

Development of having double-chamber in micro-bubble pump (두 개의 챔버를 갖는 마이크로 버블펌프의 개발)

  • 최종필;박대섭;반준호;김병희;장인배;김헌영
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1186-1190
    • /
    • 2003
  • In this paper, a valveless bubble-actuated fluid micropump was has been developed and its performance was tested. The valveless micropump consists of the lower plate, the middle plate, the upper plate and a resistive heater. The lower plate includes the nozzle-diffuser elements and the double-chamber. Nozzle-diffuser elements and a double-chamber are fabricated on the silicon wafer by the DRIE(Deep Reactive Ion Etching) process. The lower plate also has inlet/outlet channels for fluid flow. The middle plate is made of glass and plays the role of the diaphragm. The chamber in the upper plate is filled with deionized water, and which contacts with the resistive heater. The resistive heater is patterned on a silicon substrate by Ti/Pt sputtering. Three plates and the resister heater are laminated by the aligner and bonded in the anodic bonder. Since the bubble is evaporated and condensed periodically in the chamber, the fluid flows from inlet to outlet with respect to the diffusion effect. In order to avoid backflow, the double chamber system is introduced. Analytical and experimental results show the validity of the developed double-chamber micropump.

  • PDF

Evaluation of volatile organic compounds emitted from door-trim armrest using micro chamber and 20 L static chamber (마이크로 챔버와 20 L static chamber를 이용한 도어트림 암레스트로부터 방출되는 휘발성 유기화합물 평가)

  • Lee, Ik-Hee;Yoo, Ji-Ho;Kim, Man-Goo
    • Analytical Science and Technology
    • /
    • v.24 no.4
    • /
    • pp.290-297
    • /
    • 2011
  • In present, evaluation method for car cabin air quality has been developed in ISO, China, Japan. Also The management standard for new produced car has been applied since 1, July, 2010. To manage car cabin air quality, It is important to evaluate VOC emitted from interior material. In this study, complete component of door trim armrest was evaluated in accordance with ISO 12219-5, cut component was evaluated in accordance with ISO 12219-3. The vapour gas was collected with stainless tube packed with Tenax TA and analyzed with TD-GC/MS. It was confirmed that emission rate of each compounds was difficult in each evaluation method. As a result, to evaluating each components composing door trim armrest, main sources of emitting VOCs in door trim armrest were PP substrate and adhesive.

A study on the Thermopneumatic Actuator with Phase Change for Micro Pump (상변화를 이용한 열공압형 마이크로 펌프용 액츄에이터 성능에 관한 연구)

  • Park, S.;Hwang, J.Y.;Lee, S.;Kang, K.;Kang, H.;Jang, J.;Lee, H.;Kang, S.
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.425-428
    • /
    • 2006
  • Recently, Direct Methanol Fuel Cell (DMFC) for portable devices has been received much attention because DMFC has a possibility of higher energy density than electrical batteries and smaller size than other fuel cells. This paper presents the fabrication and test of a thermopneumatic microactuator with a phase change for DMFC. A microactuator consists of an inlet an outlet a chamber, a heater and a sensor of resistance temperature detector(RTD). The micoractuator is fabricated by the spin-coating process, the lithograph process, the deep RIE process and so on. The total size of microactuator is $20{\times}20{\times}0.53mm^3$. When the current is applied, the heater heats liquid in chamber. As a result the liquid vaporizes. The response of temperature in the chamber was measured using thermocouple The changed temperature is $3^{\circ}C$ for 5 sec at 0.032W.

  • PDF

Micro-tissue collecting tool for diagnosis of micro-spike biopsy (마이크로 스파이크로 채취한 조직의 진단을 위한 미세 조직회수도구)

  • Jeong, Hyo-Young;Koo, Kyo-In;Lee, Sang-Min;Ban, Jae-Won;Park, Ho-Soo;Bang, Seoung-Min;Song, Si-Young;Cho, Dong-Il Dan
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.2
    • /
    • pp.122-127
    • /
    • 2009
  • We have developed and reported several micro-spikes for minimally invasive biopsy. In this paper, a micro-tissue collecting tool for tissue diagnosis extracted by micro-spike is presented. Using proposed polydimethy-siloxane (PDMS) micro-tissue collecting tool, which has a negative micro-spike structure in a porous chamber, the extracted tissue in a micro-spike is effectively detached. The gastro-intestinal tissue of a pig is extracted in an in vivo environment, and then it is detached from a micro-spike using the PDMS micro-tissue collecting tool. A fine clinical picture of the detached tissue is acquired.