• 제목/요약/키워드: Micro chamber

검색결과 242건 처리시간 0.024초

통합형 오일 정제 시스템의 개발 (Development of an Integrated Oil Purification System)

  • 홍성호;이경희;정남화
    • Tribology and Lubricants
    • /
    • 제38권4호
    • /
    • pp.121-127
    • /
    • 2022
  • This study presents the development of an integrated oil purification system consisting of moisture removal, oil flushing, and oil filtering devices. In this system, the oil flushing device is combined with a micro-bubble generator. Oil purification is necessary for ensuring the high performance of the lubricant through the efficient removal of contaminants and thus enables good maintenance of mechanical systems. The developed purification system removes moisture, varnish, and solid particles. Moreover, during oil purification, the oil flushing device separates foreign materials and contaminants remaining in the lubricating oil piping or mechanical systems. The microbubble generator, which is combined with the oil flushing device, can separate harmful contaminants, such as sludge, wear particles, and rust, from piping or lubrication systems through the cavitation effect. Moisture is removed using a double high-vacuum chamber, while sludge and varnish are removed via electro-absorption using a high-voltage generator. Additionally, the total maintenance cost of the system is reduced through the use of domestically fabricated cartridge filters composed of glass fiber and cellulose. The heater, which maintains the temperature of the lubricant at 60℃, can process 41,000 L of lubricant simultaneously. Multiple tests confirmed that the proposed integrated purification system exhibits good performance in oil flushing and removal of water and varnish.

세기조절방사선치료(Intensity Modulated Radiation Therapy; IMRT)의 정도보증(Quality Assurance) (Quality Assurance for Intensity Modulated Radiation Therapy)

  • 조병철;박석원;오도훈;배훈식
    • Radiation Oncology Journal
    • /
    • 제19권3호
    • /
    • pp.275-286
    • /
    • 2001
  • 목적 : 세기조절방사선치료의 임상적용을 위한 정도보증 절차를 확립하고, 실제 치료환자 1례에 대한 적용 과정을 보고하고자 한다. 대상 및 방법 : 본원에서는 세기조절방사선치료를 시행하기 위해 역방향 치료계획(inverse planning) 시스템으로 $P^3IMRT$ (ADAC, 미국)와 다엽콜리메이터(Multileaf collimator, MLC)가 부착된 방사선치료용 선형가속기 Primus (Siemens, 미국)를 사용하였다. 먼저 다엽콜리메이터에 대한 위치의 정확성, 재현성, leaf transmission factor를 측정하였다. 또한 소조사면에 대한 치료계획시스템의 commissioning을 실시하였다. 이를 이용하여 C자 형태의 가상 PTV (Planning Target Volume)에 대해 9개의 빔을 사용하여 세기변조 조사빔을 설계하여, 이를 팬톰 내에서 절대선량 및 상대선량을 측정하여 비교, 분석하였다. 실제 6개의 세기변조 조사빔을 사용하여 치료를 시행한 전립선암 환자를 대상으로, 팬톰내에서 재 계산된 선량계산 결과를 0.015 cc 미소전리함, 다이오드선량계(Scanditronix, 스웨덴), 필름 선량계, 그리고 선형배열다중검출기(array detector) 등을 사용하여 절대선량 및 상대선량을 평가하였다. 결과 : MLC 위치 정확도는 1 mm 이내이었으며, 재현성은 0.5 mm 내외로 평가되었고, leaf transmission 인자는 10MV 광자선에 대해서 interleaf leakage의 경우, $1.9\%$, midleaf leakage의 경우, $0.9\%$로 측정되었다. 필름, 다이오드선량계, 미소전리함, 물팬톰용 전리함(0.125 cc) 등의 반음영을 측정해 본 결과, 물팬톰용 전리함으로 측정된 반음영 영역$(80\~20\%)$은 필름에 비해 2 mm 가량 크며, 최소 beamlet 크기가 5 mm 임을 감안할 때 부적합한 것으로 판명되었다. RTP commissioning 후 계산 선량은 $1\times1\;cm^2$ 크기 소조사면에서의 측정치와 $2\%$ 범위 내에서 일치하였다. C자 형태의 PTV에 대한 9개의 세기변조된 조사빔에 대한 2회에 걸친 치료중심점에서의 절대선량 측정결과 개별 조사빔에 대하여는 $10\%$ 이상 차이를 보였으나 총 선량은 $2\%$ 이내에서 일치하였다. 필름을 이용한 선량분포도도 계산치와 비교적 잘 일치하였다. 실제 치료환자의 팬톰 내에서의 절대선량 측정 결과 총 선량은 $1.5\%$ 차이를 보였다. 각 조사빔에 대해 중심 leaf의 측방선량분포도를 필름 및 선형배열다중검출기를 사용하여 측정하였으며, 조사면 밖에서 계산선량이 $2\%$ 내외로 작게 나타났으나, 특정 위치를 제외하고는 $3\%$ 이내로 잘 일치함을 확인하였다. 결론 : 세기조절방사선치료를 위해서는 다엽콜리메이터의 위치에 대한 보다 정밀한 정도관리 절차가 개발되어야 될 것으로 판단되며, 조사빔내 세기패턴을 효율적으로 확인할 수 있는 정도보증 절차가 필요할 것으로 사료된다. 본원에서는 팬톰 내에서의 치료중심점과 같이 특정 지점에서의 절대선량 확인 및 필름 혹은 선형배열다중검출기를 사용한 세기분포 패턴의 확인 과정을 통하여, 이를 적절히 병행하여 사용함으로써 세기조절방사선치료에 적합한 정도관리를 시행할 수 있었다.

  • PDF

자유수면에서 블레이드 수 변화가 마이크로 중력식 와류 수차 성능에 미치는 영향 (Effect of Blade Number Variations on Performance of Micro Gravitational Vortex Turbine in Free Water Surface)

  • 김종우;최인호;정기수
    • 한국습지학회지
    • /
    • 제25권3호
    • /
    • pp.176-183
    • /
    • 2023
  • 본 연구는 자유수면 아래 원통형 와류발생부에서 와류 수차 성능에 대한 블레이드 수가 미치는 영향을 이해하는 것이다. 동일한 블레이드 형상을 사용하여 상대 와류 수심비(y/hv) 0.065 ~ 0.417 범위에 설치된 2개, 3개, 4개, 5개 및 6개의 블레이드로 마이크로 와류 수차의 성능을 실험하였다. 연구 결과로서 블레이드 수가 증가함에 따라 회전수, 전압, 전류 및 출력이 유속 0.7 m/s 이하일 때 상대 와류 수심비 0.065와 0.111 지점에서 증가한다. 5개 블레이드 수차의 평균 출력은 다른 블레이드 수보다 높게 나타난다. 오리피스 근처에 설치된 직경 130 mm인 4개의 블레이드 수차의 성능이 와류발생부에서 동일한 수의 직경 220 mm인 블레이드 수차보다 높다.

광유도발광선량계(Optically Stimulated Luminescent Dosimeter)의 선량 특성에 관한 고찰 (Characteristic Evaluation of Optically Stimulated Luminescent Dosimeter (OSLD) for Dosimetry)

  • 김정미;전수동;백금문;조영필;윤화룡;권경태
    • 대한방사선치료학회지
    • /
    • 제22권2호
    • /
    • pp.123-129
    • /
    • 2010
  • 목 적: 방사선 치료의 선량평가를 위해 사용되는 Optically stimulated luminescent dosimeters (OSLD) 선량 특성을 분석하여, 선량 측정의 유용성을 알아보고자 한다. 대상 및 방법: $NanoDot^{TM}$$Inlight^{TM}$MicroStar Reader, Solid Water Phantom, 의료용 선형가속기 $TRYLOGY^{(R)}$를 사용하였다. 측정 조건은 OSLD를 Solid Water Phantom의 $D_{max}$ 깊이에 위치시킨 후 SSD는 100 cm, Field size는 $10{\times}10\;cm^2$로 하고 300 MU/min으로 6 MV 광자선, 100 cGy의 방사선을 조사하였다. OSLD를 10분 마다 판독하면서 변화값을 측정하였고, OSLD에 선량을 50 cGy와 100 cGy씩 누적시켜 판독하였다. 또한 에너지 의존성은 6 MV, 15 MV, 4~20 MeV를 사용하였다. 선량률은 100~1,000 MU/min로 변화시키면서 측정하였다. 광자선 6 MV의 PDD의 변화를 측정하기 위해 OSLD와 전리함(Ionization chamber) (FC 65P-747)을 사용하였다. 결 과: 시간의 경과에 따른 OSLD의 재현성은 ${\pm}2.5%$였다. OSLD의 선량에 대한 선형성(linearity)을 평가한 결과 300 cGy까지는 선형적으로 증가하였고, 300 cGy 이상에서는 초선형적(supralinearity)으로 증가하였다. 에너지 의존성은 ${\pm}2%$ 이내였고 선량율 의존성은 ${\pm}3%$ 이내였다. 6 MV 광자선에 대하여 OSLD로 측정한 $PDD_{10}$은 66.7%, $PDD_{20}$은 38.4%였고 전리함(Ionization chamber)으로 측정한 $PDD_{10}$은 66.6%, $PDD_{20}$은 38.3%였다. 결 론: OSLD의 특성을 분석한 결과 시간, 에너지, 선량률의 변화에 따른 차이는 ${\pm}3%$ 이내였으며 전리함(Ionization chamber)과 비교한 PDD는 0.3% 이내였다. 또한 300 cGy까지는 선량이 선형적으로 증가하였다. OSLD는 여러 번 반복 측정이 가능하였고 측정과 판독이 용이하여 선량계로서 유용성을 확인하였다.

  • PDF

초소형 마이크로콘 관입시험기의 개발 및 적용 (Development and Application of Ultra Small Micro-Cone Penetrometer)

  • 이종섭;신동현;윤형구;이우진
    • 한국지반공학회논문집
    • /
    • 제24권2호
    • /
    • pp.77-86
    • /
    • 2008
  • 흙의 교란영역과 측정값은 관입시험기의 크기에 영향을 받는다. 관입기의 크기가 작을수록 더 국부적인 값을 얻을 수 있다. 관입시험 시 흙의 교란을 최소화하면서 흙의 특성을 파악하기 위하여 극소형 마이크로콘(외경 5mm)을 설계 및 제작하였다. 선단저항력은 마이크로콘 선단부에 설치된 변형률계를 이용하여 측정하였다. 뿐만 아니라 선단 저항력으로부터 마찰저항력 성분을 효과적으로 제거하기 위하여 이중관 형식의 마찰 슬리브를 채택하였다. 설계 시 변형률계의 설치, 회로구성, 관입시스템, 관입속도, 측정률, 작동 온도, 그리고 calibration 과정이 고려되었다. 점토의 경계면, 점토-모래지반의 경계면을 마이크로콘을 적용함으로써 효과적으로 찾아 낼 수 있었다. 뿐만 아니라, 마이크로 콘과 직경 16mm의 미니어처 콘을 이용하여 측정한 선단저항력이 매우 유사하지만, 마이크로 콘의 해상도가 매우 높은 것으로 나타났다. 본 논문은 마이크로 콘이 매우 높은 해상도 그리고 주변지반의 변형을 최소화하면서 흙의 경계면을 효과적으로 감지할 수 있음을 보여준다.

원형 다중전극을 이용한 DNA 조작소자 (Micromachined DNA Manipulation Device Using Circular Multi-Electrodes)

  • 문상준;윤재영;남홍길;지연태;이승섭
    • 대한기계학회논문집A
    • /
    • 제27권7호
    • /
    • pp.1071-1075
    • /
    • 2003
  • In this paper, we present a DNA manipulation device in the reaction chamber, which consists of a center electrode and circular outer electrodes of a reaction unit. The charged bio-molecules, DNA, are manipulated by the charge of the electrode in reaction unit. Controlling the induced dynamic electric field between the center electrode and the outer electrodes, concentration / repulsion / manipulation of bio-molecules are enabled at a periphery of electrode. Concentration of the fluorescent DNA at the center electrode is observed by applying +2V. Subsequently, applying -2V, the concentrated DNA is repelled rapidly from the center electrode, which makes dispersion completely in 0.5second. Furthermore, repeated applying +1V/-1V every 5 seconds at each outer electrode, we can circulate the DNA. We also investigate a micro-heater and sensor for DNA manipulation and reaction temperature. The coefficient of heat-resistance and heater temperature characteristic is 0.0043 and 100$^{\circ}C$/sec, respectively.

마이크로 전자빔 시스템을 위한 전자광학렌즈의 제작에 의한 나노 패턴 형성 (Nano-scale pattern delineation by fabrication of electron-optical lens for micro E-beam system)

  • 이용재;박정영;전국진;국양
    • 전자공학회논문지D
    • /
    • 제35D권9호
    • /
    • pp.42-47
    • /
    • 1998
  • 현재의 전자빔 묘화의 한계를 극복할 수 있는 마이크로 전자빔 시스템의 전자 광학 렌즈를 제작하였고 전자빔 묘화실험을 통하여 이를 검증하였다. 마이크로머시닝기술을 이용하여 실리콘 전극을 제작하고 이를 양극 접합을 통해 조립하여 다층 전극의 전자 광학 렌즈를 제작하였다. 완성된 전자 광학 소자를 초고진공 챔버에 장착하여, STM(Scanning Tunneling Microscope) 팁에서 방출된 전자빔의 focusing 특성을 관찰하였으며 전자를 집속하여 리소그라피를 수행하였다. E-beam 감광막은 PMMA(Poly-methylmethacrylate)를 사용하였고 0.13㎛의 패턴을 형성시킬 수 있었다.

  • PDF

Liquid phase hydrogen peroxide decomposition for micro-propulsion applications

  • McDevitt, M. Ryan;Hitt, Darren L.
    • Advances in aircraft and spacecraft science
    • /
    • 제4권1호
    • /
    • pp.21-35
    • /
    • 2017
  • Hydrogen peroxide is being considered as a monopropellant in micropropulsion systems for the next generation of miniaturized satellites ('nanosats') due to its high energy density, modest specific impulse and green characteristics. Efforts at the University of Vermont have focused on the development of a MEMS-based microthruster that uses a novel slug flow monopropellant injection scheme to generate thrust and impulse-bits commensurate with the intended micropropulsion application. The present study is a computational effort to investigate the initial decomposition of the monopropellant as it enters the catalytic chamber, and to compare the impact of the monopropellant injection scheme on decomposition performance. Two-dimensional numerical studies of the monopropellant in microchannel geometries have been developed and used to characterize the performance of the monopropellant before vaporization occurs. The results of these studies show that monopropellant in the lamellar flow regime, which lacks a non-diffusive mixing mechanism, does not decompose at a rate that is suitable for the microthruster dimensions. In contrast, monopropellant in the slug flow regime decomposes 57% faster than lamellar flow for a given length, indicating that the monopropellant injection scheme has potential benefits for the performance of the microthruster.

보온력 차이에 따른 방한복 상의의 인체착의 생리반응 (Physiological Responses of Cold Protective Clothing with Different clo Value)

  • 이정숙;김희은;송민규
    • 한국의류산업학회지
    • /
    • 제10권5호
    • /
    • pp.683-689
    • /
    • 2008
  • The purpose of this study was to investigate physiological responses such as rectal temperature, skin temperature, micro climate, sweat rate and subjective sensations using cold protective clothing with five different clo value. The clo value was measured by thermal manikin in windless condition. Healthy five 20's males volunteered as subjects for wearing trial experiment. The climate chamber was controlled at $50^{\circ}C$, 65% RH. The experiment consisted of repeated exercise and recovery periods. We found that the higher clo value has, the higher mean skin temperature, micro climate and sweat rate show. They felt warm and wet with higher insulation clothing. Thermal comfort increased in the last recovery period after exercise. There was significant difference between five cold protective clothing. In correlation analysis of clo value, it showed that correlation coefficient(r) values were more than 0.8. Therefore, in terms of clothing insulation, we found that correlation between thermal manikin experiment and wearing trial experiment was high. Clothing insulation could be variable according to many factors such as body movement, covering area, clothing gap, layering and design. Considering the body movement, we thought that insulation measurement need to carry out both thermal manikin experiment and wearing trial experiment.

Fabrication and Characteristics of Micro-Electro-Mechanical-System-Based Gas Flow Sensor

  • Choi, Ju-Chan;Lee, June-Kyoo;Kong, Seong-Ho
    • 센서학회지
    • /
    • 제20권6호
    • /
    • pp.363-367
    • /
    • 2011
  • This paper proposes a highly-sensitive gas flow sensor with a simple structure. The sensor is composed of a micro-heater for heating the gas medium and a pair of temperature sensors for detecting temperature differences due to gas flow in a sealed chamber on one axis. Operation of the gas flow sensor depends on the transfer of heat through the air medium. The proposed gas flow sensor has the capability to measure gas flow rates <5 $cm^3$/min with a resolution of approximately 0.01 $cm^3$/min. Furthermore, this paper reports some additional experiment results, including the sensitivity of the proposed gas flow sensor as a function of operating current and the flow of different types of gas(oxygen, carbon dioxide, and nitrogen). The fabrication process of the proposed sensor is very simple, making it a good candidate for mass production.