• Title/Summary/Keyword: Micro Line

Search Result 617, Processing Time 0.027 seconds

Laser Stream Patterning Improvement for Gravure Printing (그라비아 인쇄를 위한 Laser Stream Patterning 개선)

  • Ahn T. Y.;Kim H. G.;Lee D. H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2001.10a
    • /
    • pp.186-189
    • /
    • 2001
  • The main method in micro-etching process, used in manufacturing semiconductors, electronic components, circuits, is Photo Masking method that exposes and develops on the photo-sensitivity solutions or films. This method enables one to process highly precisely, $\pm$0.03 mm in end line location area. But this has limits in a high speed / wide width process, difficulties in endless masking, and the problem of high price. We have developed the direct masking method to make use of Gravure printing, widely used in grocery packing sheet printing. We made cylinder tools to influence the masking quality by laser stream process. We have confirmed that the end line location accuracy in the line width of the product is improved from 0.12 mm to $\pm$0.07 mm level, after etching process.

  • PDF

A Study on the Design and Development of Automatic Optical Fiber Aligner (자동 광섬유 정렬 장치의 설계 및 제작에 관한 연구)

  • Kim, Byung-Hee;Uhm, Chul;Choi, Young-Suk
    • Journal of Industrial Technology
    • /
    • v.22 no.B
    • /
    • pp.241-249
    • /
    • 2002
  • Optical fiber is indispensable for optical communication systems that transmit large volumes of data at high speed, but super precision technology in sub-micron units is required for optical axis adjustment. We developed the automatic optical fiber by image processing and automatic loading system. we have developed 6-axis micro stage system for I/O optical fiber arrays, the initial automatic aligning system software for a input optical array by the image processing technique, fast I/O-synchronous aligning strategy, the automatic loading/unloading system and the automatic UV bonding mechanism. In order to adjust the alignment it used on PC based motion controller, a $10{\mu}m$ repeat-detailed drawing of automatic loading system is developed by a primary line up for high detailed drawing. Also, at this researches used the image processing system and algorithm instead of the existing a primary hand-line up and fiber input array and waveguide chip formed in line by automatic.

  • PDF

Design of Half-Wavelength Low-PASS Filter using EBG Structure (EBG 구조를 이용한 반파장 저역통과 여파기 설계)

  • Kang, Myung-Soo;Kim, Young-Tae;Park, Jun-Seok
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2003.11a
    • /
    • pp.376-379
    • /
    • 2003
  • In this raper, proposed easy half-wavelength LPF and acceptor structure in actuality manufacture using EBG (Electromagnatic Bandgap) structure for application of micro-strip circuit. Because conventional half-wavelength LPF and acceptor is narrow line-width of High impedance, actuality manufacture is difficult. Width that in proposed structure narrow microstrip line of High impedance EBG structure use and has equal impedance embodied to wide microstrip line. Also, it is seen that actuality manufacture is available applying to half-wavelength LPF that have cut-off Frequency of 3GHz.

  • PDF

Islanding Detection Based on Complex Power at the Intertie (연계점에서의 복소전력을 이용한 단독운전 판단기법)

  • Kang, Yong-Cheol;Cha, Sun-Hee;Jang, Sung-Il;Kang, Hae-Gweon;Kim, Yong-Gyun;Park, Goon-Cherl
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.12
    • /
    • pp.2167-2172
    • /
    • 2008
  • A large scale embedded generator or a micro-grid is usually interconnected to the grid through the dedicated line. Immediately after the removal of the grid supply, it must be disconnected and remain disconnected until the normal grid supplies are restored. This paper proposes an islanding detection algorithm based on complex power at the intertie. Complex power at the intertie delivered to the grid has a value depending on power flow during normal operation. When loss of mains occurs, complex power at the intertie moves to a value depending on the parameters of the dedicated line. The performance of the proposed algorithm was investigated under various operating and fault conditions. The proposed algorithm can detect an islanding operation even if no power is exchanged prior to loss of mains and discriminate the fault condition from islanding.

Properties of Ag Thin Films Deposited in Oxygen Atmosphere Using in- line Magnetron Sputter System (In-line 마그네트론 스퍼터 장치를 사용하여 산소 분위기에서 제작한 Ag 박막의 특성)

  • Ku, Dae-Young;Kim, Won-Mok;Cho, Sang-Moo;Hwang, Man-Soo;Lee, In-Kyu;Cheong, Byung-Ki;Lee, Taek-Sung;Lee, Kyeong-Seok;Cho, Sung-Hun
    • Korean Journal of Materials Research
    • /
    • v.12 no.8
    • /
    • pp.661-668
    • /
    • 2002
  • A study was made to examine the electrical, compositional, structural and morphological properties of Ag thin films deposited by DC magnetron sputtering in $O_2$ atmosphere with deposition temperature from room temperature to 15$0^{\circ}C$ using in-line sputter system. The Ag films deposited at temperature above $100^{\circ}C$ in oxygen atmosphere gave a similar specific resistivity to and even lower oxygen content than those deposited using pure Ar sputter gas The Ag films deposited with pure Ar gas was mainly composed of crystallites with [111] preferred orientation, while, for those deposited in oxygen atmosphere, more than 50% of the volume was composed of crystallites with [100] orientation. The difference in the micro structure did not cause any difference in the specific resistivity of Ag films. The results showed that the transparent conducting oxide films and the Ag films could be processed sequentially in the same deposition chamber with careful control of deposition temperature, which might result in a cost reduction for constructing the large scale in-line deposition system.

Evaluation of Factors Used in AAPM TG-43 Formalism Using Segmented Sources Integration Method and Monte Carlo Simulation: Implementation of microSelectron HDR Ir-192 Source (미소선원 적분법과 몬테칼로 방법을 이용한 AAPM TG-43 선량계산 인자 평가: microSelectron HDR Ir-192 선원에 대한 적용)

  • Ahn, Woo-Sang;Jang, Won-Woo;Park, Sung-Ho;Jung, Sang-Hoon;Cho, Woon-Kap;Kim, Young-Seok;Ahn, Seung-Do
    • Progress in Medical Physics
    • /
    • v.22 no.4
    • /
    • pp.190-197
    • /
    • 2011
  • Currently, the dose distribution calculation used by commercial treatment planning systems (TPSs) for high-dose rate (HDR) brachytherapy is derived from point and line source approximation method recommended by AAPM Task Group 43 (TG-43). However, the study of Monte Carlo (MC) simulation is required in order to assess the accuracy of dose calculation around three-dimensional Ir-192 source. In this study, geometry factor was calculated using segmented sources integration method by dividing microSelectron HDR Ir-192 source into smaller parts. The Monte Carlo code (MCNPX 2.5.0) was used to calculate the dose rate $\dot{D}(r,\theta)$ at a point ($r,\theta$) away from a HDR Ir-192 source in spherical water phantom with 30 cm diameter. Finally, anisotropy function and radial dose function were calculated from obtained results. The obtained geometry factor was compared with that calculated from line source approximation. Similarly, obtained anisotropy function and radial dose function were compared with those derived from MCPT results by Williamson. The geometry factor calculated from segmented sources integration method and line source approximation was within 0.2% for $r{\geq}0.5$ cm and 1.33% for r=0.1 cm, respectively. The relative-root mean square error (R-RMSE) of anisotropy function obtained by this study and Williamson was 2.33% for r=0.25 cm and within 1% for r>0.5 cm, respectively. The R-RMSE of radial dose function was 0.46% at radial distance from 0.1 to 14.0 cm. The geometry factor acquired from segmented sources integration method and line source approximation was in good agreement for $r{\geq}0.1$ cm. However, application of segmented sources integration method seems to be valid, since this method using three-dimensional Ir-192 source provides more realistic geometry factor. The anisotropy function and radial dose function estimated from MCNPX in this study and MCPT by Williamson are in good agreement within uncertainty of Monte Carlo codes except at radial distance of r=0.25 cm. It is expected that Monte Carlo code used in this study could be applied to other sources utilized for brachytherapy.

Fabrication of novel micromachined microstrip transmission line for millimeter wave applications (마이크로머시닝 기술을 이용한 새로운 형태의 고주파 저손실 Microstrip 전송선의 제작)

  • 이한신;김성찬;임병옥;신동훈;김순구;박현창;이진구
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.8
    • /
    • pp.37-44
    • /
    • 2004
  • This paper describes a new GaAs-based surface-micromachined microstrip line supported by dielectric post and air-gapped signal line with ground metal. This new type of dielectric-supported air-gapped microstripline(DAML) structure is developed using surface micromachining techniques to provide easy means of airbridge connection between the signal lines and to archive low losses at millimeter-wave frequency band with wide impedance range. Each DAMLs with the length of 5 mm are fabricated and the measured characteristics are compared with those of the conventional microstrip transmission line. These transmission lines are composed of 10 ${\mu}{\textrm}{m}$ height of signal line, post size of 10 ${\mu}{\textrm}{m}$ ${\times}$ 10 ${\mu}{\textrm}{m}$ and post height of 9 ${\mu}{\textrm}{m}$. By elevating the signal lines from the substrate using the micromachining technology, the substrate dielectric loss can be reduced Compared with of the conventional microstrip transmission line showing 7.5 dB/cm loss at 50 GHz, the loss can be reduced to 1.1 dB/cm loss at 50 GHz.

A Study on Moving Fitness and Slit Length in Relation to Length & Silhouette of Tight Skirt (타이트 스커트 실루엣 및 길이에 따른 동작적합성과 트임길이에 관한 연구)

  • Kim, Hee Young;Choi, Hae Sun
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.17 no.4
    • /
    • pp.539-549
    • /
    • 1993
  • The purpose of this study was to find out the moving fitness and slit length of tight skirt in relation to its length & silhouette. Five kinds of length, micro mini, mini, natural line, medi and maxi, and two kinds of siihuette, slim & straight-a total of ten tight skirts-were investigated. Ten college students were chosen for this experiment. The moving fitness was tested by measuring the step length, step width and step angle in the case of walking on the flat and going up the stairway & bus stair. The slit length was tested by measuring the back slit length needed in the case of going up stairway & bus stair. Data were analyzed with use of SAS pakage. The statistics were based on average, standard diviation, two-way ANOVA, Pearson's correlation and multiple regression analysis. The main results were as follows. 1. There was significant difference in the moving fitness according to length & silhouette of tight skirt. The moving fitness of slim type was lower than that of straight type and the longer the skirt length was, the lower the moving fitness was. The significance appeared particularly in the case of going up the bus stair. 2. There was significant difference in the skirt length obove slit accorting to length & silhouette of tight skirt. The skirt length obove slit of slim type was shorter than that of straight type. The longer skirt length was, the longer it was from micro mini to natural line, that of medi skirt was shorter or a little longer than that of natural line skirt and there was little change from medi skirt to maxi skirt.

  • PDF

Development of simulation method for heating line optimization of E-Mold by using commercial CAE softwares (전산모사 프로그램을 이용한 E-MOLD의 Heating Line 배치의 최적화 설계에 관한 연구)

  • Chung, Jae-Youp;Kim, Dong-Hak
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.6
    • /
    • pp.1754-1759
    • /
    • 2008
  • To produce plastic parts that have fine pattern through conventional injection molding, a lot of difficulties follow. Therefore, rapid heating and cooling methods are good candidates for manufacturing injection-molded parts with micro/nano patterns. In this study, we adopted the E-Mold patent technology. The mold for E-Mold technology has a separate heated core with micro heaters. It is very important to optimize the lay-out of the heaters in heated core because it influences both control and distribution of mold temperature. We developed a optimization method of heating line lay-out by using commercial softwares and compared the output with the experimental results. We used Pro-Engineer Wildfire 2.0 for the mold design, ICEMCFD for mesh generation, and FLUENT for heat transfer simulation. The simulation results showed the temperature profile from $60^{\circ}C$ to $120^{\circ}C$ or $180^{\circ}C$ during heating and cooling process which were compared with the injection molding experiments. We concluded that the simulation could well explain the experimental results. It was shown that the E-Mold optimization design for heater lay-out could be available through the simulation.

Low Conversion Loss and High Isolation 94 GHz MHEMT Mixer Using Micro-machined Ring Coupler (마이크로 머시닝 링 커플러를 사용한 낮은 변환 손실 및 높은 격리 특성의 94 GHz MHEMT 믹서)

  • An Dan;Kim Sung-Chan;Park Jung-Dong;Lee Mun-Kyo;Lee Bok-Hyung;Park Hyun-Chang;Shin Dong-Hoong;Rhee Jin-Koo
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.43 no.6 s.348
    • /
    • pp.46-52
    • /
    • 2006
  • We report on a high performance 94 GHz MMIC resistive mixer using 70-nm metamorphic high electron mobility transistor (MHEMT) and micro-machined W-band ring coupler. A novel 3-dimensional structure of resistive mixer was proposed in this work, and the ring coupler with the surface micro-machined dielectric-supported air-gap microstrip line (DAMLs) structure was used for high LO-RF isolation. The fabricated mixer showed an excellent LO-RF isolation of -29.3 dB and a low conversion loss of 8.9 dB at 94 GHz. To our knowledge, compared to previously reported W-band mixers, the proposed MHEMT-based resistive mixer using micro-machined ring coupler has shown superior LO-RF isolation as well as similar conversion loss.