A Study on Determining the Size of the Interface Inductor for Grid-Connected Micro-Sources (Micro-Source의 계통 연계용 인덕터 크기 선정에 관한 연구)

  • Son, Kwang-Myung;Kim, Young-Seob
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • 제19권6호
    • /
    • pp.52-58
    • /
    • 2005
  • The concept of the Micro-Grid comprising Micro-Sources supplying both heat and power ranging from several [KW] to 1[MW] to local customers is proposed by CERTS(Consortium for Electric Reliability Technology Solutions). Micro-Sources adopt environmentally friendly and reliable power sources such as Fuel-Cell and Micro-Turbines. Micro-Sources adopt voltage source inverter with AC grid system in order to provide independent real and reactive power control for premium power quality. Thus Micro-Source needs series inductance for interfacing with AC grid system. With this reason, we propose a technique that can decide the optimal size of the inductor for effective transfer of the power into the grid.

Bilateral Series Resonant Inverter for High Frequency Link UPS (고주파 링크 무정전 교류 전원장치를 위한 직렬 공진형 인버어터)

  • 신봉수;정용호;조규형
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • 제38권7호
    • /
    • pp.524-538
    • /
    • 1989
  • A new bilateral series resonant inverter and its control method are proposed. The proposed inverter consists of zero current switched cycloconverter. Output voltage is regulated by modulating the average magnitude of resonant current sinusoidally. Cycloconverter synthesizes low frequency output voltage from high frequency resonant current pulses. In the proposed inverter, bidirectional power flow in possible and isolation transformer is miniaturized. The proposed control method is verified through simulation and experiment. The proposed inverter will satisfy the small size and low cost requirements of small Uninterruptible Power Supply (UPS) of less than 1 KVA suitable for micro-computers and electronic equipments used in office and home automation.

The Operation of SRM through mathematical equations from the maximum torque (최대 토크 해석 방정식에 의한 SRM의 구동)

  • 서종윤
    • Proceedings of the KIPE Conference
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.725-728
    • /
    • 2000
  • This paper presents the switching angle and voltage for maximizing torque of 4-phase 6-poles SRM. The switching angle and voltages was determined through the approximated analysis and computer simulation by using SIMULINK according to the speed and torque required by load but we used new analytic equation from maximum torque characteristic And then one-chp micro-controller controls the switching angle and voltage of an asymmetrical inverter in the SRM driver. Also we expects that this method reduce micro-controller load and realize approximated real time control

  • PDF

Design of a Electronic Ballast using Microprocessor (마이크로 프로세서를 이용한 전자식 안정기 설계)

  • Lee, Chang-Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • 제21권5호
    • /
    • pp.44-52
    • /
    • 2007
  • In this study, design and control method using low cost Micro-controller(MCU) for inverter driving circuit in fluorescence lamp is presented. Soft starting technique is adopted to reduce switching loss and moment deterioration which are induced by high speed switching frequency in inverter ballast. Performance of the ballast stabilizer and the lighting characteristic of the fluorescence lamp have been improved by stabilizing switching pulses through the Pulse Width Modulation control.

Isolated Feedback of Inverter DC-Link Voltage Using Flyback Converters (플라이백 컨버터를 이용한 인버터 직류링크 전압의 절연 궤환)

  • Kim, Kyung-Seo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • 제23권4호
    • /
    • pp.281-285
    • /
    • 2018
  • An isolated feedback method for measuring the inverter DC-link voltage is proposed. This method provides a simple and economical solution to inverter control systems that use a flyback converter as a controller power supply. In the proposed method, data on the DC-link voltage are acquired when the primary side voltage appears on the secondary side of the flyback transformer, thereby eliminating the need to adopt an extra signal isolation method. To solve the non-synchronization problem between the flyback converter switching and main controller sampling, the external interrupt function of the micro-controller is used as a trigger signal for the A/D conversion.

Feeder Flow Control Algorithm for Photovoltaic-Fuel cell Hybrid System in Micro-Grid (마이크로그리드에서 태양광-연료전지 하이브리드 시스템의 Feeder Flow Mode 운영 기법)

  • Moon, Dae-Seong;Gang, Gi-Hyeok;Kim, Yun-Seong;Seo, Jae-Jin;Won, Dong-Jun
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.161-163
    • /
    • 2008
  • The paper deals with a inverter control scheme to apply feeder flow control in the hybrid system consisted of a photovoltaic system and a fuel-cell system. The inverter operation modes and a feeder control reference is changed by changing of the loads. Simulation results using the PSCAD/EMTDC are presented to establish a inverter control method for a Feeder flow control mode.

  • PDF

Development of VVVF Inverter Control System for Propulsion System (차량용 VVVF 인버터 제어시스템 개발)

  • Kim, B.S.;Lee, K.C.;Lee, H.S.;Kim, S.W.;Park, Y.C.;Kim, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.249-251
    • /
    • 1994
  • This paper introduces an implementation of high performance voltage source inverter system based on 16bit micro-processor and DSP for the application to modem rolling stock traction system. In contrast with other industry oriented inverter system, this system requires precise control action complying with various load condition and high overload capability. An asynchronous PWM generation and 3' pulse mode technology are adopted in order to improve compliant starting torque characteristics at starting phase and soft backward-forward starting motion.

  • PDF

Inverter Air-conditioner Power System with Low Power Dissipation Type using Micro-controller

  • Mun, Sang-Pil;Shu, Ki-Young;Kim, Ju-Yong;Kim, Kwang-Tae
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 한국조명전기설비학회 2004년도 춘계학술대회 논문집
    • /
    • pp.492-496
    • /
    • 2004
  • When using a conventional power factor correction circuit, a comparatively huge capacitor is used to boost-up output voltage. It has a large amount of harmonic distortion in the input current waveform. To improve the input current waveform of diode rectifiers, we propose a new operating principle for the power factor correction circuit. Due to the fact that the proposed circuit uses smaller ones and a smaller reactor, the output voltage increases and obtains higher input current waveforms. These are suitable for the harmonics guidelines. The proposed circuit is able to obtain higher power factor and efficiency. Also, it has reduced switching loss and held over-shooting by using an inverter of eliminated dead-time HPWM that has non-linear impedance circuits to make up diodes, capacitance and a reactor. We compared the conventional PWM inverter and proposed HPWM inverters and found that a high input power factor of 97[%] and an efficiency of 98[%] were also obtained.

  • PDF

Stand alone type Fuel Cell generation system controlled by micro-processor (마이크로프로세서에 의해 제어되는 독립형 연료전지용 전력변환 회로 설계)

  • 이원철;이태원;장수진;김진태;문승필;원충연
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 한국조명전기설비학회 2003년도 학술대회논문집
    • /
    • pp.63-68
    • /
    • 2003
  • Recently, a fuel cell is remarkable for new generation system. The fuel cell generation system converts the chemical energy of a fuel directly into electrical energy. The fuel cell generation is characterized by low voltage and high current. For connecting to general load, it needs both a step up converter and an inverter. The step up converter makes DC to DC and the inverter changes DC to AC. In this paper, full bridge converter and the single phase inverter are designed and installed for fuel cell. Simulation and experimental results are displayed under several load conditions.

  • PDF

Photovoltaic Micro Converter Operated in Boundary Conduction Mode Interfaced with DC Distribution System

  • Seo, Gab-Su;Shin, Jong-Won;Cho, Bo-Hyung;Lee, Kyu-Chan
    • Proceedings of the KIPE Conference
    • /
    • 전력전자학회 2011년도 추계학술대회
    • /
    • pp.44-45
    • /
    • 2011
  • Research on photovoltaic (PV) generation is taking a lot of attention due to its infinity and environment-friendliness with decrease of price per PV cell. While central inverters connect group of PV modules to utility grid in which maximum power point tracking (MPPT) for each module is difficult, micro inverter is attached on each module so that MPPT for individual modules can be easily achieved. Moreover, energy generation and consumption efficiency can be much improved by employing direct current (DC) distribution system. In this paper, a digitally controlled PV micro converter interfacing PV to DC distribution system is proposed. Boundary conduction mode (BCM) is utilized to achieve zero voltage switching (ZVS) of active switch and eliminate reverse recovery problem of passive switch. A 120W prototype boost PV micro converter is implemented to verify the feasibility and experimental results show higher than 98% efficiency at peak power and 97.29% of European efficiency.

  • PDF