• Title/Summary/Keyword: Micro Bubble

Search Result 196, Processing Time 0.025 seconds

Painless Microjet Injector Using Laser Pulse Energy (레이저 펄스 에너지를 이용한 무통증 마이크로젯 약물전달시스템)

  • Yoh, Jai-Ick;Han, Tae-Hee;Hah, Jung-Moo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.5
    • /
    • pp.547-550
    • /
    • 2011
  • We have developed a laser-based needle-free liquid drug-injection device. A laser beam is focused inside the liquid contained in the rubber chamber of a micro-scale. The focused laser beam causes explosive bubble growth, and the sudden volume increase in a sealed chamber drives a microjet of liquid drug through the micronozzle. The exit diameter of a nozzle is less than 100 ${\mu}m$, and we verify that the injected microjet is fast enough to penetrate soft human tissue. In the experiment, the microjet penetrated a 5% gelatin-water solution that replicates the human thrombus and pork-fat tissue.

Simulation of non-steady state oxygen transfer caused by microbubble supply (비정상상태의 미세기포에 의한 산소 전달 특성 모사)

  • Lee, Jaiyeop;Kim, Ilho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.5
    • /
    • pp.381-388
    • /
    • 2018
  • Microbubbles oxygen transfer to water was simulated based on experimental results obtained from the bubbles generation operated under varying liquid supply velocity to the multi-step orifices of the generator. It had been known that liquid supply velocity and bubble size are inversely related. In the oxygen transfer, a non-steady state was assumed and the pseudo stagnation caused the slow movement of bubbles from the bottom to the water surface. Two parameters were considered for the simulation: They represent a factor to correct the pseudo stagnation state and a scale which represented the amount of bubbles in supply versus time. The sum of absolute error determined by fitting regression to the experimental results was comparable to that of the American Society of Civil Engineers (ASCE) model, which is based on concentration differential as the driving force. Hence, considering the bubbles formation factors, the simulation process has the potential to be easily used for applications by introducing two parameters in the assumptions. Compared with the ASCE model, the simulation method reproduced the experimental results well by detailed conditions.

Simulation of Water/steam into Sodium Leak Behavior for an Acoustic Noise Generation Mechanism Study

  • Kim, Tae-Joon;Hwang, Sung-Tai;Jeong, Kyung-Chai;Park, Jong-Hyeun;Valery S. Yughay
    • Nuclear Engineering and Technology
    • /
    • v.33 no.2
    • /
    • pp.145-155
    • /
    • 2001
  • This simulation first allows us to define a transition zone from a bubble to jet mode of the argon out-flow and hereinafter to define a similar area for water-steam leak in the KALIMER SG (Korea Advanced Liquid Metal Reactor Steam Generator) using a water mock-up system, taking into account the KALIMER leak classification and tube bundle design, as a simulation of a real water-steam into sodium leak. in accordance with leak conditions in the KALIMER SG, the transition from bubbling to jetting is studied by means of turbulence regime simulation for argon out-flow through a very small orifice, which has the equivalent diameter of about 0.253 mm. finally the noise generation mechanism is explained from the existing experimental data. We also confirmed the possibility of micro-leak detection from the information of the bubbling mode through simulations and the experiment in this study.

  • PDF

Treatment of Exhaust Pollutants from a Lime Kiln of Paper-mill with Micro-bubble System (마이크로버블 장치를 이용한 제지공정 소성로 배기 오염물질 처리)

  • Jung, Jae-Ouk;Jung, Yong-Jun
    • Journal of Environmental Science International
    • /
    • v.29 no.11
    • /
    • pp.1025-1032
    • /
    • 2020
  • This work was performed to develop a dip injection wet scrubber (DIWS) system with chlorine dioxide as the oxidant. The exhaust pollutants from a lime kiln of paper-mill were introduced to the system. When NaClO3 was used to oxidize NO into NO2, the oxidation was unsatisfactory and the combination of HNO3 or H2SO4 was required for 100% oxidation. ClO2 is recommended to oxidize NO and SO2 effectively. With the combination of 1st stage of DIWS and ClO2, 57.1% of NOx and 98% of SO2 were effectively removed. In the case of 2nd stage of DIWS and ClO2, 93.5% of NOx and 99% of SO2 were removed. The ClO2+DIWS process was superior to the ClO2+Scrubber process in terms of investment, running cost and NOx removal efficiency.

Development of a painless injector using high speed laser propulsion and its spin-off to medical industry (고속레이저추진원리를 활용한 무통증 주사기의 개발 및 의료산업으로의 Spin-off)

  • Han, Tae-Hee;Yoh, Jai-Ick
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.05a
    • /
    • pp.326-330
    • /
    • 2010
  • A laser based needle-free liquid drug injection device has been developed. A laser beam is focused inside the liquid contained in the rubber chamber of micro scale. The focused laser beam causes explosive bubble growth, and the sudden volume increase in a sealed chamber drives a microjet of liquid drug through the micronozzle. The exit diameter of a nozzle is 125 ${\mu}m$ and the injected microjet reaches an average velocity of 264 m/s. This device adds the time-varying feature of microjet to the current state of liquid injection for drug delivery.

  • PDF

Analysis of the operating factors of dissolved air flotation (DAF) process for effluent quality improvement from aquaculture rearing tank (양식장 배출수 수질관리를 위한 용존공기부상 공법의 운전 인자 영향 분석)

  • Ki, Jae-Hong;Kim, Hyoung-Jun;Lee, Ju-Young;Han, Moo-Young;Gang, Hee-Woong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.1
    • /
    • pp.107-113
    • /
    • 2012
  • Pollutants in aquaculture system effluent mostly originated from solid wastes including uneaten feed and excreta of cultured species. In this research, DAF(Dissolved Air Flotation) unit is suggested as an integrated solid control unit especially as a form of IIBG(Inline Injection Bubble Generation) process in aquaculture system. Solid removal performance of DAF unit was examined under various operation and salinity conditions with turbidity and suspended solid. Solid waste removal efficiencies were found to be affected by operation conditions including saturator pressure, recycle ratio, coagulant concentration. Solid removal efficiency was higher under higher saturator pressure and recycle ratio under which condition larger number of bubbles is generated. Coagulant is thought to have important role in creating bubble-particle aggregate by showing better removal efficiency with higher concentration. However higher saline water showed less effectiveness in removing solids by DAF(IIBG). Application of DAF(IIBG) process also showed additional effect in phosphate removal and DO(Dissolved Oxygen) supply. Phosphate existed in polluted water was removed up to 46% after treatment, which is thought to attribute to aluminium phosphate precipitation. And DO concentration was found to increase over 50% of initial saturation concentration after the injection of micro-bubbles. Through experiments on solid removal from aquaculture effluent, DAF(IIBG) process is estimated to be effective solid control method. This property can help aquaculture system being installed and operated simply and effectively.

A Study on Cost-effective Treatment of Wastewater and Odor Reduction for Southeast Asian Market Entry

  • Jung, Min-Jae;Kim, Yong-Do;Kwon, Lee-Seung;Lee, Woo-Sic;Kwon, Woo-Taeg
    • The Journal of Industrial Distribution & Business
    • /
    • v.9 no.12
    • /
    • pp.23-29
    • /
    • 2018
  • Purpose - The purpose of this study is to apply a cost effective ultrasonic odor reduction method that generated micro-bubbles using ejector to the Southeast Asian wastewater market. Research design, data, and methodology - A leather maker located in Ansan-city, Gyunggi-do, South Korea was sampled from the collection tank to select experimental materials. Experimental setup consisted of circulating water tank-air ejector-ultrasonic device, and circulating wastewater. Sample analysis was performed by CODcr, T-N, T-P, and turbidity by the National Environmental Science Institute. Results - Experimental results show that it is most effective in removing odors when the frequency range of ultrasonic wave is 60~80 Khz and the output is 200 W. It showed that the concentration of complex odor dropped from a maximum of 14,422 times to a minimum of 120 times. Also, analysis of ammonia and hydrogen sulfide in specific odor substances has shown that they were reduced from 1.5 ppm to 0.4 ppm and from 0.6 ppm to 0.1 ppm, respectively. Conclusions - It is possible to shorten more than 12 hours in the treatment of micro-organisms. It can be seen that the processing time of odor after ultrasonic treatment in the pre-treatment facility is reduced by 25% when compared to the resultant micro-organisms after the chemical treatment, that is, the time of the bio-treatment of micro-organisms. Based on the results, it was confirmed that the pre-treatment method using the ultrasonic and the air ejector device of the experiment shows the effect of reducing the water pollutants and odor more effectively in a relatively short time than the conventional advanced oxidation method.

Reclamation of Effluent Textile Wastewater Using Micro/nano Bubbles-Dissolved Ozone Flotation Process (초미세기포-용존오존부상(DOF)공정을 이용한 염색폐수 처리수의 재이용)

  • Jung, Byung-Gil;Lee, Ki-Hyung;Jung, Jin-Hee;Jang, Seong-Ho;Cho, Do-Hyun;Sung, Nak-Chang
    • Journal of Environmental Science International
    • /
    • v.20 no.3
    • /
    • pp.291-299
    • /
    • 2011
  • The main objectives of this research are to investigate characteristics of ozone solubility due to low solubility of conventional bubbles-ozone generators, evaluate the treatment characteristics of reclaiming textile wastewater for industrial water by means of micro/nano bubbles-dissolved ozone flotation(MNB-DOF) process. The textile wastewater used in this research was obtained from final effluent of the textile wastewater in B city. There is a 400L reactor which consists of a micro-nano bubble system and a ozone generator for experiments. As a result of generating micro-nano bubbles (below $0.5{\mu}m$) by using of MNB-DOF process, it improved ozone solubility due to higher ozone transfer rates. Consequently, the shorter ozonation time clearly indicates the lower power costs. The reported results clearly indicated that MNB-DOF process can be effectively and inexpensively. Results of the experiments through MNB-DOF process in this study satisfy all reclaiming standards as industrial water: pH 6.5~8.5, SS 10 mg/L or below, $BOD_5$) 6 mg/L or below, turbidity 10 NTU or below, Coliforms 1,000/100 mL or below. Therefore there is a possibility of the reclaiming of the textile wastewater as industrial water.

Colour Removal from Dyestuff Wastewater by Micro Bubbles Flotation Process (마이크로 버블 부상 공정에 의한 염료폐수의 색도 제거)

  • Kim, Myeng-Joo;Han, Sien-Ho
    • Applied Chemistry for Engineering
    • /
    • v.33 no.6
    • /
    • pp.606-612
    • /
    • 2022
  • The purpose of this study is to convert hydrophobic dyestuff to hydrophilic dyestuff by reacting cationic collector with anionic dyestuff and reaction anionic collector with cationic dyestuff. The removal of colors from aqueous solutions and/or dispersions has been studied by dispersed-air flotation in a batch column. In this studies used generated micro bubble by ceramic gas diffuser having micro pore size for air flotation process. In this study, a ceramic gas diffuser with micro pore size was used to generate micro bubbles for the air flotation process. Two colours were used for the experiments: Basic Yellow 1 (cationic dyestuff) and Direct Orange 10 (anionic dyestuff). All two were effectively removed by flotation within 8 mins. Sodium dodecyl sulfate, sodium oleate (an anionic collector), and amines (a cationic collector) were found to be effective as collectors in the removal of color, which was found to be related to the pH of the solution and the amount of collector added to it, with high collector dosages causing the process to become pH-independent.

Comparative Study on Removal Characteristics of Disinfection By-products by Air Stripping and Flotation Processes (탈기와 부상 공정에 의한 소독부산물의 제거특성에 관한 비교 연구)

  • Cha, Hwa-Jeong;Won, Chan-Hee;Lee, Kang-Hag;Oh, Won-Kyu;Kwak, Dong-Heui
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.9
    • /
    • pp.513-520
    • /
    • 2016
  • It is well known that volatile compounds including disinfection by-products as well as emissive dissolved gas in water can be removed effectively by air stripping. The micro-bubbles of flotation unit are so tiny as microns while the diameter of fine bubbles applied to air stripping is ranged from hundreds to thousands of micrometer. Therefore, the micro-bubbles in flotation can supply very wide specific surface area to transfer volatile matters through gas-liquid boundary. In addition, long emission time also can be gained to emit the volatile compound owing to the slow rise velocity of micro-bubbles in the flotation tank. There was a significant difference of the THMs species removal efficiency between air stripping and flotation experiments in this study. Moreover, the results of comparative experiments on the removal characteristics of THMs between air stripping and flotation revealed that the mass transfer coefficient, $K_La$ showed obvious differences. To overcome the limit of low removal efficiency of dissolved volatile compounds such as THMs in flotation process, the operation range of bubble volume concentration is required to higher than the operation condition of conventional particle separation.