• Title/Summary/Keyword: Mg-Graphite

Search Result 87, Processing Time 0.025 seconds

An ionic liquid incorporated gel polymer electrolyte for double layer capacitors

  • Perera, Kumudu S.;Prasadini, K.W.;Vidanapathirana, Kamal P.
    • Advances in Energy Research
    • /
    • v.7 no.1
    • /
    • pp.21-34
    • /
    • 2020
  • Energy storage devices have received a keen interest throughout the world due to high power consumption. A large number of research activities are being conducted on electrochemical double layer capacitors (EDLCs) because of their high power density and higher energy density. In the present study, an EDLC was fabricated using natural graphite based electrodes and ionic liquid (IL) based gel polymer electrolyte (GPE). The IL based GPE was prepared using the IL, 1-ethyl-3-methylimidazolium trifluoromethanesulfonate (1E3MITF) with the polymer poly(vinyl chloride) (PVC) and the salt magnesium trifluoromethanesulfonate (Mg(CF3SO3)2 - MgTF). GPE was characterized by electrochemical impedance spectroscopy (EIS), DC polarization test, linear sweep voltammetry (LSV) test and cyclic voltammetry (CV) test. The maximum room temperature conductivity of the sample was 1.64 × 10-4 Scm-1. The electrolyte was purely an ionic conductor and the anionic contribution was prominent. Fabricated EDLC was characterized by EIS, CV and galvanostatic charge discharge (GCD) tests. CV test of the EDLC exhibits a single electrode specific capacitance of 1.44 Fg-1 initially and GCD test gives 0.83 Fg-1 as initial single electrode specific discharge capacitance. Moreover, a good stability was observed for prolonged cycling and the device can be used for applications with further modifications.

Synthesis of Highly Dispersed and Conductive Graphene Sheets by Exfoliation of Preheated Graphite in a Sealed Bath and its Applications to Polyimide Nanocomposites

  • Hossain, Muhammad Mohsin;Hahn, Jae Ryang;Ku, Bon-Cheol
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.7
    • /
    • pp.2049-2056
    • /
    • 2014
  • A simple method for exfoliating pristine graphite to yield mono-, bi-, and multi-layers of graphene sheets as a highly concentrated (5.25 mg/mL) and yielded solution in an organic solvent was developed. Pre-thermal treatment of pristine graphite at $900^{\circ}C$ in a sealed stainless steel bath under high pressures, followed by sonication in 1-methyl-2-pyrrolidinone solvent at elevated temperatures, produced a homogeneous, well-dispersed, and non-oxidized graphene solution with a low defect density. The electrical conductivities of the graphene sheets were very high, up to 848 S/cm. These graphene sheets were used to fabricate graphene-polyimide nanocomposites, which displayed a higher electrical conductivity (1.37 S/m) with an improved tensile strength (95 MPa). The synthesized graphene sheets and nanocomposites were characterized by transmission electron microscopy, scanning electron microscopy, atomic force microscopy, X-ray photoelectron spectroscopy, and Raman spectroscopy.

Studies on the Control of Porosity and Mean Pore Size in Cordierite Ceramics (Cordierite의 기공률 및 기공경조절에 관한 연구)

  • Yang, Jin
    • Journal of the Korean Ceramic Society
    • /
    • v.35 no.4
    • /
    • pp.399-405
    • /
    • 1998
  • The effect of each factor on the porosity and mean pore size of cordierite(2Mg$.$2{{{{ {Al}_{2 } {O }_{3 } }}$.$5{{{{ {SiO}_{2 } }}) ceram-ics which have been mainly used for hot gas filter was investigated by using orthogonal array. The poros-ity was observed to increase with the content of graphite added as pore-forming material and decrease with increasing talc size. The effects of the other factors the graphite size sintering temperature and hold-ing time at sintering temperature were observed to be small relatively. In case of mean pore size the ef-fect of talc size on the mean pore size of cordierity was investigated to be the largest. The mean pore size was observed to increase with increasing talc size.

  • PDF

Electrochemical Diagnosis of Magnesium Ion in Fish Liver and Mice Droppings

  • Lee, Chang-Hyun;Ly, Suw Young
    • Journal of the Korean Applied Science and Technology
    • /
    • v.31 no.4
    • /
    • pp.663-668
    • /
    • 2014
  • An in-vivo diagnosis of trace Mg(II) ion was performed using a low-cost and environment-friendly voltammetric method, using a graphite counter and reference electrodes and a fluorine-immobilized graphite working electrode, and clean deep seawater was used as an electrolyte solution. Under optimum conditions, the analytical working ranges attained microgram ranges, and a detection limit of $80.6ugL^{-1}$ was obtained using stripping voltammety with 60 sec accumulation time. Ex-vivo application was performed on fish liver and mice droppings. The developed techniques can be applicable to tumor cell analysis.

Effect of Carbon Equivalent on the Fading Behavior of Hypoeutectic Ductile Cast Iron (아공정 구상흑연주철의 Fading 거동에 미치는 탄소당량의 영향)

  • Park, Hun-Berm;Park, Sang-Jun
    • Journal of Korea Foundry Society
    • /
    • v.24 no.5
    • /
    • pp.290-294
    • /
    • 2004
  • The effect of carbon equivalent on the fading behavior of hypoeutectic ductile cast iron was investigated. The carbon content was slightly increased right after graphite spheroidization treatment and remained almost constant with holding at $1,490^{\circ}C$ after 4 minute. The residual magnesium content was decreased slowly with holding. The empirical equation expressing the relationship between this and holding time was proposed ; $C=C_o-P{\times}t$. The proportionality constant, P, was inversely proportional to carbon content.

Structural Arrangements and Bonding Analysis of MgB2C2

  • Kang, Dae-Bok
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.9
    • /
    • pp.2565-2570
    • /
    • 2010
  • The orthorhombic $MgB_2C_2$ structure contains well-separated parallel graphite-like $B_2C_2^{2-}$ layers which extend infinitely in two dimensions. Three possible ways to distribute B and C atoms in the hexagonal sublattice sites are adopted. Band structures for the hypothetical distribution patterns are examined to assess the electronic stability of these phases and to account for the observed arrangement by means of extended Huckel tight-binding calculations. The preferred choice is the layer with B and C alternating strictly so that B is nearest neighbor to C and vice versa. A rationale for this is given. Due to the alternation of B and C within the honeycomb layers, $MgB_2C_2$ is a band insulator, which through partial substitution of Mg with Li, is predicted to turn metallic with holes in the $\sigma$ bands at the Fermi level.

Adsorption of p-Xylene by Expanded Graphite (팽창흑연을 이용한 p-Xylene 흡착)

  • Lee, Chae-Young;Jee, Hyeong-Sub;Chung, Jae-Woo;Kim, Sang-Hyoun;Cho, Yun-Chul;Kang, Seok-Tae
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.5
    • /
    • pp.35-40
    • /
    • 2012
  • In this study, adsorption characteristics of expanded graphite (EG) were investigated by a series of batch adsorption tests using p-Xylene as a model volatile organic compounds (VOCs). After acid treatment, graphite were expanded at various temperature from $600^{\circ}C$ to $1000^{\circ}C$ for one minute. The optimal temperature was $800^{\circ}C$, where the expansion ratio reached 195 times of original volume. The BET specific surface area of EG was $92.4m^2/g$, which was only 1/10 of granular activated carbon (GAC), however the adsorption of p-Xylene by EG was almost completed within 5 minutes while that of GAC continued for 7 days because the majority of pores of EG was consisted with meso- and macro-pores. According to the Langmuir isotherm analysis, the maximum specific adsorption of p-Xylene onto EG was 24.0 mg/L with the adsorption constant of 7.94. In conclusion, the adsorption capacity of EG was much less than that of GAC due to the significantly lower specific surface area, but the first order kinetic constant was more than 500 times larger than GAC. Overall, EG might be effective where the fast adsorption is required.

Current Generation from Microbial Fuel Cell Using Stainless Steel Wire as Anode Electrode (스텐철사를 전극으로 이용하는 미생물연료전지의 전류 발생)

  • Jang, Jae Kyung;Kim, Kyung Min;Byun, SungAh;Ryou, Young Sun;Chang, In Seop;Kang, Young Koo;Kim, Young Hwa
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.11
    • /
    • pp.753-757
    • /
    • 2014
  • Anode electrode in a microbial fuel cell (MFC) should transfer the receiving electron as well as provide large surface area that can be immobilized microorganisms. Microorganisms' population is one of important factors to improve the current generation and to treat the livestock wastewater by biological treatment. These studies were attempted to investigate if stainless-steel wire skein (SSWS) could be used as anode electrode replacement a graphite felt electrode in microbial fuel cell. For these studies, pretreated livestock wastewater was used diluted to 500 mg/L as COD before use. At this time, the current showed a little difference of about 5% when using each of a SSW and graphite felt (control). There was no significant difference in the current value. The organic removal rate in the microbial fuel cells used graphite felt and SSWS was 82.4% and 88.3%, respectively. The COD removal in the MFC used the SSWS was higher than that of graphite felt. Ammonium nitrogen was showed similar trend in two case all. These results about current generation and organic matter reduction seem possible that SSWS was used to anode electrode. When SSWS is used, the initial investment for system construction is expected to be able to reduce by approximately 1/50.

Studies on a Feasibility of Swine Farm Wastewater Treatment using Microbial Fuel Cell (미생물연료전지의 가축분뇨 처리 가능성 연구)

  • Jang, Jae-Kyung;Kim, Se-Hee;Ryou, Young-Sun;Lee, Sung-Hyoun;Kim, Jong-Gu;Kang, Young-Goo;Kim, Young-Hwa;Choi, Jung-Eun
    • Microbiology and Biotechnology Letters
    • /
    • v.38 no.4
    • /
    • pp.461-466
    • /
    • 2010
  • In this study the feasibility of simultaneous electricity generation and treatment of swine farm wastewater using microbial fuel cells (MFCs) was examined. Two single-chamber MFCs containing an anode filled with different ratio of graphite felt and stainless-steel cross strip was used in all tests. The proportion of stainless-steel cross strip to graphite felt in the anode of control microbial fuel cell (CMFC) was higher than that of swine microbial fuel cell (SMFC) to reduce construction costs. SMFCs produced a stable current of 18 mA by swine wastewater with chemical oxygen demand (COD) of $3.167{\pm}80\;mg/L$ after enriched. The maximum power density and current density of SMFCs were $680\;mW/m^3$ and $3,770\;mA/m^3$, respectively. In the CMFC, power density and current density was lower than that of SMFC. CODs decreased by the SMFC and CMFC from $3.167{\pm}80$ to $865{\pm}21$ and $930{\pm}14\;mg/L$, achieving 72.7% and 70.6% COD removal, respectively. The suspended solid (SS) of both fuel cells was also reduced over 99% ($4,533{\pm}67$ to $24.0{\pm}6.0\;mg/L$). The concentration of nutritive salts, ${NH_4}^+$, ${NO_3}^-$, and ${PO_4}^{3-}$, dropped by 65.4%, 57.5%, and 73.7% by the SMFC, respectively. These results were similar with those of CMFC. These results show that the microbial fuel cells using electrode with mix stainless-steel cross strip and graphite felt can treat the swine wastewater simultaneously with an electricity generation from swine wastewater.

Determination of Trace Metals in Fel Ursi (시판 웅담의 미량금속 정량에 관한 연구)

  • Lee, Sook-Yun;Yu, Bong-Shin;Mun, Hye-Ryoung;Kim, Sung-Kyung
    • Korean Journal of Pharmacognosy
    • /
    • v.13 no.3
    • /
    • pp.102-105
    • /
    • 1982
  • Nine trace elements in Bear Galls(Fel Ursi) studied in this paper are Na, Mg, K, Ca, Cu, Zn, Fe, Pb and Ge. The contents of Na, Mg, K, Ca, Cu, Zn, Fe, Pb are determined by atomic absorption spectrometry and Ge is determined by graphite atomic absorption spectrometry. In both methods, the sample is digested with nitric-perchloric acid and then ashed. The results of analysis are shown in table and the result obtained from this study are as follows. a. The highest content of trace element of Bear Gall is Na and other elements are getting lower in order of K, Mg, Ca, Ge, Zn, Fe, Cu, and Pb. b. Particularly the content of Ge in Bear Gall was determined.

  • PDF