• Title/Summary/Keyword: Method of stationary phase

Search Result 183, Processing Time 0.028 seconds

A Study on Sound Radition from the Periodic Structure depend on Symmetrical beam space Using FEM (FEM을 이용한 대칭형 보강재에 보강된 평판의 음향방사에 관한 연구)

  • Kim J.T.;Kim T.H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.732-739
    • /
    • 2005
  • The determination of sound pressure radiated from periodic plate structures is fundamental in the estimation of noise level in aircraft fuselages or ship hull structures. As a robust approach to this problem, here a very general and comprehensive analytical model is developed for predicting the sound radiated by a vibrating plate stiffened by periodically spaced orthogonal symmetrical beams subjected to a sinusoidally time varying point load. In this these, we experiment with the numerical analysis using the space harmonic series and the SYSNOISE for measuring the vibration mode and character of response caused by sound radiation with adding the harmonic point force in the thin isotropic plate supported by the rectangular lattice reinforcement. We used the reinforcements, beams of open type section like the style of 'ㄷ' letter; the space of the beams were chosen to be 0.2m, 0.3m, 0.4m. We studied the behavior of sound pressure levels, analysis of vibration mode between support points, connection between frequency function and sound pressure levels, and connection between position function and sound pressure levels.

  • PDF

Development and Validation of an Analytical Method for Glucuronolactone in Energy Drinks by Hydrophilic Interaction Liquid Chromatography-electrospray Tandem Mass Spectrometry

  • Oh, Mi Hyune;Lim, Moo Song;Chai, Jeung Young;Kim, Eun Jung;Cho, Joong Hoon;Lim, Chul Joo;Choi, Sun Ok
    • Journal of Food Hygiene and Safety
    • /
    • v.32 no.2
    • /
    • pp.89-95
    • /
    • 2017
  • A rapid, sensitive analytical method for glucuronolactone in beverages was developed and validated using hydrophilic interaction liquid chromatography coupled to electrospray ionization tandem mass spectrometry (HILIC-ESI-MS/MS). To determine the optimum analytical conditions for glucuronolactone, three different kinds of HILIC columns and two mobile phases with different pH values were examined. An amide-bonded stationary phase with a pH 9 acetonitrile-rich mobile phase was the best condition in terms of column retention, ESI-MS/MS response area, and signal-to-noise ratio. After extraction, glucuronolactone was separated through the HILIC amide column and detected by negative ESI-MS/MS in selected reaction monitoring (SRM) mode. Nine energy drinks sold in Korea were spiked with glucuronolactone at a concentration of 5 ng/mL; the Monster $Energy^{TM}$ sample showed the smallest peak area and its signal-to-noise ratio was used for method validation. Good linearity was obtained in the concentration range from 20 to 1500 ng/mL with a correlation coefficient > 0.998. The developed method had a limit of detection (LOD) of 6 ng/mL and a limit of quantitation (LOQ) of 20 ng/mL. The recovery of this method at concentration of 20, 100, 500, and 1000 ng/mL was 96.3%-99.2% with relative standard deviations (RSD) of 1.6%-14.0%. A reproducibility precision assessment at concentration of 100 and 500 ng/mL was carried out among three laboratories. The recovery of that evaluation was 95.1%-102.3% with RSD of 2.7%-7.0%. An analysis of variance indicated that there was no difference between the recovery results of the three laboratories at the 5% significance level. The validated method is applicable to inspecting beverages adulterated with glucuronolactone in Korea.

Modeling and Direct Power Control Method of Vienna Rectifiers Using the Sliding Mode Control Approach

  • Ma, Hui;Xie, Yunxiang;Sun, Biaoguang;Mo, Lingjun
    • Journal of Power Electronics
    • /
    • v.15 no.1
    • /
    • pp.190-201
    • /
    • 2015
  • This paper uses the switching function approach to present a simple state model of the Vienna-type rectifier. The approach introduces the relationship between the DC-link neutral point voltage and the AC side phase currents. A novel direct power control (DPC) strategy, which is based on the sliding mode control (SMC) for Vienna I rectifiers, is developed using the proposed power model in the stationary ${\alpha}-{\beta}$ reference frames. The SMC-based DPC methodology directly regulates instantaneous active and reactive powers without transforming to a synchronous rotating coordinate reference frame or a tracking phase angle of grid voltage. Moreover, the required rectifier control voltages are directly calculated by utilizing the non-linear SMC scheme. Theoretically, active and reactive power flows are controlled without ripple or cross coupling. Furthermore, the fixed-switching frequency is obtained by employing the simplified space vector modulation (SVM). SVM solves the complicated designing problem of the AC harmonic filter. The simplified SVM is based on the simplification of the space vector diagram of a three-level converter into that of a two-level converter. The dwelling time calculation and switching sequence selection are easily implemented like those in the conventional two-level rectifier. Replacing the current control loops with power control loops simplifies the system design and enhances the transient performance. The simulation models in MATLAB/Simulink and the digital signal processor-controlled 1.5 kW Vienna-type rectifier are used to verify the fast responses and robustness of the proposed control scheme.

Isolation and Characterization of Thermophilic Bacillus licheniformis YJ09 from Spent Mushroom (Pleurotus ostreatus) Substrates (느타리 수확후배지로부터 분리된 고온성 Bacillus licheniformis YJ09의 특성)

  • Kim, Hye Soo;Kim, Chul Hwan;Cho, Soo Jeong
    • Journal of Mushroom
    • /
    • v.14 no.4
    • /
    • pp.244-248
    • /
    • 2016
  • In order to isolate thermophilic bacteria with high activity of CMCase and xylanase, spent mushroom substrates was collected from an oyster mushroom cultivation farm in Jinju, Gyeongnam, Korea. Among the isolates, one strain designated as YJ09 was selected by agar diffusion method. The isolate YJ09 was identified as a member of Bacillus licheniformis based on biochemical characteristics using Bacillus ID kit and MicroLog system. Comparative 16S rDNA sequence analysis showed that isolate YJ09 formed a distinct phylogenetic tree within the genus Bacillus and was most closely related to Bacillus licheniformis with sequence similarity of 98.9%. Based on its physiological properties, biochemical characteristics and phylogenetic distinctiveness, the isolate YJ09 was classified as Bacillus licheniformis. The CMCase and xylanase activity of B. licheniformis YJ09 was slightly increased corresponding to the bacterial population from exponential phase to stationary phase in the growth curve of B. licheniformis YJ09.

Characterization and Enhanced Production of Enterocin HJ35 by Enterococcus faecium HJ35 Isolated from Human Skin

  • Yoon Yoh Chang;Park Hye Jung;Lee Na-Kyoung;Paik Hyun-Dong
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.10 no.4
    • /
    • pp.296-303
    • /
    • 2005
  • A strain named as HJ35 was isolated from the skin of sixty-five men and fourteen women for acne therapy, in order to find an effective antimicrobial agent against Propionibacterium acnes. Isolate HJ35 was identified as Enterococcus faecium based on 16 rDNA sequence and produced enterocin HJ35 having antimicrobial activities against most lactic acid bacteria, En­terococcus spp., Staphylococcus aureus, S. epidermidis, Clostridium perfringens, some bacilli, Mi­crococcus flavus, Listeria monocytogenes, L. ivanovii, Escherichia coli, Pseudomonas fluorescens and Propionibacterium acnes, in the modified well diffusion method. Especially, enterocin HJ35 showed a bactericidal activity against Propionibacterium acnes P1. The antimicrobial activity of enterocin HJ35 was disappeared completely with the use of protease XIV. But enterocin HJ35 activity is very stable at high temperature (up to $100^{\circ}C$ for 30 min), in wide range of pH (3.0${\~}$9.0), and by treatment with organic solvents. The apparent molecular mass of enterocin HJ35 was estimated to be approximately 4${\~}$4.5 kDa on detection of its bactericidal activity after SDS-PAGE. In batch fermentation of E. faecium HJ35, enterocin HJ35 was produced at the mid­log growth phase, and its maximum production was obtained up to 2,300 AU/mL at the late stationary phase. By employing fed-batch fermentation, the enhanced production of enterocin HJ35 was achieved up to 12,800 AU/mL by feeding with 10 g/L glucose or 6 g/L lactate.

Cellulase and Xylanase Activity of Compost-promoting Bacteria Bacillus sp. SJ21 (부숙촉진 세균 Bacillus sp. SJ21 균주의 cellulase와 xylanase 활성)

  • Shin, Pyung-Gyun;Cho, Soo-Jeong
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.44 no.5
    • /
    • pp.836-840
    • /
    • 2011
  • In order to isolate thermophilic compost-promoting bacteria with high activity of cellulase and xylanase, spent mushroom substrates with sawdust were collected from mushroom cultivation farm, Jinju, Gyeongnam in Korea. Among of the isolates, one strain, designated SJ21 was selected by agar diffusion method. The strain SJ21 was identified as members of the Bacillus lincheniformis by biochemical characteristics using Bacillus ID kit and VITEK 2 system. Comparative 16S rDNA gene sequence analysis showed that strain SJ21 formed a distinct phylogenetic tree within the genus Bacillus and was most closely related to Bacillus subtilis with 16S rDNA gene sequence similarity of 99%. On the basis of its physiological properties, biochemical characteristics and phylogenetic distinctiveness, strain SJ21 was classified within the genus Bacillus, for which the name Bacillus sp. SJ21 is proposed. The cellulase and xylanase activity of Bacillus sp. SJ21 was slightly increased according to bacterial population from exponential phase to stationary phase in growth curve for Bacillus sp. SJ21.

Development of Human Detection Algorithm for Automotive Radar (보행자 탐지용 차량용 레이더 신호처리 알고리즘 구현 및 검증)

  • Hyun, Eugin;Jin, Young-Seok;Kim, Bong-Seok;Lee, Jong-Hun
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.25 no.1
    • /
    • pp.92-102
    • /
    • 2017
  • For an automotive surveillance radar system, fast-chirp train based FMCW (Frequency Modulated Continuous Wave) radar is a very effective method, because clutter and moving targets are easily separated in a 2D range-velocity map. However, pedestrians with low echo signals may be masked by strong clutter in actual field. To address this problem, we proposed in the previous work a clutter cancellation and moving target indication algorithm using the coherent phase method. In the present paper, we initially composed the test set-up using a 24 GHz FMCW transceiver and a real-time data logging board in order to verify this algorithm. Next, we created two indoor test environments consisting of moving human and stationary targets. It was found that pedestrians and strong clutter could be effectively separated when the proposed method is used. We also designed and implemented these algorithms in FPGA (Field Programmable Gate Array) in order to analyze the hardware and time complexities. The results demonstrated that the complexity overhead was nearly zero compared to when the typical method was used.

Rapid HPLC Method for the Simultaneous Determination of Eight Urinary Metabolites of Toluene, Xylene and Styrene

  • Lee, Cheol-Woo;Lee, Jeong-Mi;Lee, Jae-Hyun;Eom, Han-Young;Kim, Min-Kyung;Suh, Joon-Hyuk;Yeom, Hye-Sun;Kim, Un-Yong;Youm, Jeong-Rok;Han, Sang-Beom
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.9
    • /
    • pp.2021-2026
    • /
    • 2009
  • Toluene, xylene and styrene are volatile organic solvents that are commonly used in mixtures in many industries. Because these solvents are metabolized and then excreted in urine, their urinary metabolites are thought to be biomarkers of occupational exposure to these solvents. Therefore, a simple, rapid, and yet reliable analytical method for determining the metabolites is required for accurate biological monitoring. In the present study, a simple and rapid HPLC-UV method was developed for the simultaneous determination of eight major metabolites of toluene, xylene and styrene: hippuric acid (HA), mandelic acid (MA), o-, m- and p-methylhippuric acids (o-, m- and p-MHAs), and o-, m- and p-cresols. A monolithic column was employed as the stationary phase and several conditions, including flow rate, composition of mobile phase and column temperature, were variables for the optimization of the chromatographic resolution. All eight metabolites were successfully resolved within 5 minutes in 10% aqueous ethanol containing 0.3% acetic acid and 1.6% $\beta$-cyclodextrin, using a flow rate gradient of 1.0 - 5.0 mL/min at 25 ${^{\circ}C}$. The performance of this method was validated by linearity, intra- and inter-day accuracy, and precision. The linearity was observed with correlation coefficients of 0.9998 for HA, 0.9999 for MA, 0.9989 for o-MHA, 0.9998 for m-MHA, 0.9991 for p-MHA, 0.9997 for o-cresol, 0.9998 for m-cresol, and 0.9986 for p-cresol. The intra- and inter-day precision of the method were less than 5.89% (CV) and the accuracy ranged from 92.95 to 106.62%. The validity was further confirmed by analysis of reference samples that were prepared by the inter-laboratory quality assurance program of the Korea Occupational Safety and Health Agency (KOSHA, Seoul, Korea). All measured concentrations of the analytes agreed with the certified values.

HPLC Method Validation of Naringin Determination in Goheung Yuzu Extract as a Functional Ingredient (건강기능식품 기능성 원료로서 고흥 유자 추출물의 지표성분 Naringin 분석법)

  • Moon, So-Hyun;Ko, Eun-Young;Assefa, Awraris Derbie;Park, Se-Won
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.43 no.11
    • /
    • pp.1737-1741
    • /
    • 2014
  • An HPLC method for determination of naringin was developed to standardize it as a marker compound in Goheung yuzu extract as a functional health food. Optimum results were obtained by C-18 column chromatography using solvent mixtures (A: 0.5% acetic acid, B: acetonitrile) as the stationary phase and mobile phase. The method was fully validated and sensitive with a limit of detection (LOD) of 0.0218 mg/L and limit of quantification (LOQ) of 0.0661 mg/L. The method showed high linearity (coefficient of correlation=0.9986) and high accuracy, as recovery rates of naringin at concentrations of 1, 0.5, 0.1, 0.05 mg/mL were in the ranges of 95.74~98.25%, 97.67~101.01%, 97.33~104.64%, and 95.53~106.82%, respectively. Intra-day and inter-day variation, which are measures of method precision, were 1.39~1.95% and 0.17~1.49%, respectively. Therefore, the method could be used without modification for determination of naringin as a marker compound in Goheung yuzu extracts.

Ammonia Gas Removal by Bacillus subtilis IB101 and Dctimization of Culture Media (Bacillus subtilis IB101을 이용한 암모니아 가스 제거 및 생산배지 최적화)

  • Kim, So-Young;Noh, Yong-Ho;Kang, Sung-Gak;Kim, Young-Bum;Jang, Woo-Jin;Kim, Dong-Joon;Yun, Hyun-Shik
    • KSBB Journal
    • /
    • v.22 no.3
    • /
    • pp.162-167
    • /
    • 2007
  • Ammonia gas is one of the major pollutants which cause environmental pollution and damage to the human and the livestock. The objective of this study was to investigate the important parameters for the development of efficient removal of ammonia gas by Bacillius subtilis IB101 and to optimize the medium composition for the mass production of B. subtilis IB101. The ammonia gas removal efficiency was evaluated at different growth phases and by changing culture conditions (temperature, pH). The effect of $(NH_4)_2SO_4$ concentration in preculture medium was examined. Medium optimization for the mass production of B. subtilis IB101 was performed by using Plackett-Burman design and one factor at a time method. The removal of ammonia gas was more efficient at exponential phase by 20% than at stationary phase. The ammonia gas removal was the highest at pH 4 and 30 $^{\circ}C$. There was not any significant influence of concentration of $(NH_4)_2SO_4$ on the removal of ammonia gas. The components of optimized medium for the production of viable Bacillus subtilis IB101 was yeast extract 10 g/l, soluble starch 2.5 g/l, $MgSO_4$ 6 g/l, $CaCl_2$ 1.55 g/l, $(NH_4)_2SO_4$ 5 g/l, $KH_2PO_4$ 0.75 g/l, soy bean meal 8 g/l.