• Title/Summary/Keyword: Method of energy saving

Search Result 686, Processing Time 0.028 seconds

Evaluation of Energy Saving with Vector Control Inverter Driving Centrifugal Pump System (벡터 제어 인버터 구동 원심펌프시스템의 에너지 절감 평가)

  • Suh, Sang-Ho;Kim, Kyungwuk;Kim, Hyoung-Ho;Yoon, In Sik;Cho, Min-Tae
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.2
    • /
    • pp.67-72
    • /
    • 2015
  • The purpose of this study is to achieve energy saving effect of inverter driving multistage centrifugal pump. For determining the operation points in the pump system, the system curves should be obtained experimentally. To get the system curves, three pumps combined in parallel and one pump operated with different rotational speeds. But for variable speed pump system, energy saving rates can not be evaluated from operation efficiencies. That is why operation efficiencies, system curves, duty cycles, and input powers of the pump system were measured by the constructed experimental apparatus. The duty cycle segmented into different flow rates and weighting the average value for each segment by the interval time. The system was operated with two different periods. The mean duty cycles were collected from apartment and found that the system operated at 40% and at 50% or below capacity. Measured energy saving rate was 58.16%. Estimating method of energy saving rate could be more effective operation index than that of operation efficiency.

Analysis of energy-saving effects of recirculation aquaculture system using seawater source heat pumps and solar power generation (해수 열원 히트펌프와 태양광 발전을 이용한 순환여과식 양식장의 에너지 절감 효과 분석)

  • Jong-Hyeok RYU;Hyeon-Suk JEONG;Seok-Kwon JEONG
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.60 no.2
    • /
    • pp.194-206
    • /
    • 2024
  • This study focuses on analyzing the energy-saving effects of the recirculation aquaculture system using seawater source heat pumps and solar power generation. Based on the thermal load analysis conducted using the transient system simulation tool, the annual energy consumption of the recirculation aquaculture system was analyzed and the energy-saving effects of utilizing the photovoltaic system was evaluated. When analyzing the heat load, the sea areas where the fish farms are located, the type of breeding tank, and the circulation rate of breeding water were taken into consideration. In addition, a method for determining the appropriate capacity for each operation time was examined when applying the energy storage system instead of the existing diesel generator as an emergency power, which is required to maintain the water temperature of breeding water during power outage. The results suggest that, among the four seas considered, Jeju should be estimated to achieve the highest energy-saving performance using the solar power generation, with approximately 45% energy savings.

An Analysis of Heating and Cooling Loads by Insulated Shades and Control Method in an Energy Saving Apartment (에너지절약형 주택에서의 단열차양 적용과 제어방법에 따른 냉난방부하 분석)

  • Park, Sun-Hyo;Kwon, Kyung-Woo;Sohn, Jang-Yeul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.6
    • /
    • pp.392-397
    • /
    • 2010
  • Energy loss from windows accounts for large scores of heating and cooling loads also in energy saving apartments that is reduced over 30% of total energy consumption. Movable reflective insulations, insulation shutters, blinds, insulated shades are used to reduce energy loads from windows. In this study, energy saving performance of insulated shades was simulated by control methods. According to installation of insulated shades, heating loads were decreased about 10.5~11.3%, and cooling loads are decreased about 29.1~38.3% on an energy saving apartment. The heating peak load was reduced about 9.5% by insulated shades and the cooling peak load was reduced about 25.7~31.5%. In the case of insulated shades with automatic control system, simple time schedule control system would be more efficient than outdoor detection control system that should use several sensors.

A Study on the Energy Saving and the Reproducibility of highly-efficient Injection Molding Machine (고효율 사출성형기의 에너지 절감 및 성형 재현성 연구)

  • Jeong, C.;Kim, J.S.;Yoon, K.H.;Ahn, H.J.;Hwang, C.J.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2008.10a
    • /
    • pp.418-421
    • /
    • 2008
  • Because of steep rise of international energy cost in recent years high efficiency has been emphasized in energy policy. As far as injection molding machine is concerned, hybrid method using hydraulic and electric systems became the key to this energy saving. the energy saving and molding reproducibility of hybrid injection molding process were shown experimentally, power consumption of hybrid machine is 38% as compared with that of hydraulic machine. Furthermore, the molding reproducibility showed between two methods.

  • PDF

The Energy Saving and the Reproducibility of Highly-Efficient Injection Molding Machine (고효율 사출성형기의 에너지 절감 및 성형 재현성 연구)

  • Hwang, C.J.;Kim, J.S.;Jeong, C.;An, H.J.;Heo, Y.M.;Kim, J.D.;Yoon, K.H.
    • Transactions of Materials Processing
    • /
    • v.17 no.8
    • /
    • pp.662-667
    • /
    • 2008
  • Because of steep rise of international energy cost in recent years, high efficiency has been emphasized in energy policy. As far as injection molding machine is concerned, hybrid method using hydraulic and electric systems became the key to this energy saving. The energy saving and molding reproducibility of hybrid injection molding process were shown experimentally. The power consumption of hybrid injection molding machine is reduced to 38% as compared with that of hydraulic machine. Furthermore, the molding reproducibility was shown for both methods.

Techniques of Management and Energy saving by using power installation (전력사용설비의 에너지 절감방안 및 관리를 위한 진단기법)

  • Chung, Choon-Byeong;Jeon, Kee-Young;Hahm, Nyun-Gun;Kim, Dae-Gyun;Lee, Sang-Chip;Oh, Bong-Hwan;Lee, Hoon-Gu;Han, Kyung-Hee
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.329-333
    • /
    • 2004
  • The human beings have increased concern about Energy saving and alternative energy. The power demand has increased the growth of industry and the improvement of life. We have to explore alternate energy sources and utilize effectively domestic resources. The lighting equipments developed Energy saving by using an electric ballast. The load installation should be promoted to rational power management, according to the network, inteligent, and high-function. Therefore, this paper has studied the method of energy saving and consulting.

  • PDF

A Study on Energy saving for refrigeration warehouse (냉동냉장창고에 대한 에너지 절약에 대한 연구)

  • Chung, Choon-Byeong;Kim, Dae-Gyun;Kim, Ik-Hwan;Lee, Sang-Chip;Hahm, Nyun-Gun;Jeon, Kee-Young;Lee, Hoon-Gu;Han, Kyung-Hee
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.270-274
    • /
    • 2005
  • The human beings have increased concern about Energy saving and alternative energy. The power demand has increased the growth of industry and the improvement of life. We have to explore alternate energy sources and utilize effectively domestic resources. The lighting equipments developed Energy saving by using an electric ballast. The load installation should be promoted to rational power management, according to the network, inteligent, and high-function. Therefore, this paper has studied the method of energy saving and consulting.

  • PDF

Techniques of Management and Energy saving by using Power installation (전력 사용설비의 에너지 절감방안 및 관리를 위한 진단기법)

  • Lee, S.C.;Jeon, K.Y.;Harm, N.G.;Kim, D.G.;Kang, S.W.;Oh, B.H.;Lee, H.G.;Han, K.H.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1102-1104
    • /
    • 2003
  • The human beings have increased concern about energy saving and alternative energy. The Power demand has increased the growth of industry and the improvement of lift. We have to explore alternate energy sources and utilize effectively domestic resources. The lighting equipments developed energy saving by using an electric ballast. The load installation should be promoted to rational power management according to the network, intelligent and high-function. Therefore, this paper has studied the method of energy saving and consulting.

  • PDF

Power Consumption Management Algorithm Based on OpenADR (OpenADR 기반의 전력사용량 관리 알고리즘)

  • Kim, Jeong-Uk
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.12
    • /
    • pp.991-994
    • /
    • 2016
  • This paper presents a load management method based on OpenADR of smart grid. Previous demand side algorithm is restricted on reducing peak power. But, in this paper we suggest a method of performing the energy-saving control according to the power price utilizing building automatic control system installed on the customer side in the case of hourly differential pricing signal is transmitted to the open automated demand response system. And, we showed the integrated demand management software for 3 buildings.

A Study on the Perfomance Analysis of Low Energy Cooling Systems in Office building (사무소건물의 에너지절약형 냉방시스템 성능분석에 관한 연구)

  • Park, Chang-Bong;Rhee, Eon-Gu
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.6
    • /
    • pp.89-94
    • /
    • 2010
  • A large portion of the energy cost of a building is cooling and heating to maintain a comfortable indoor environment. Air conditioning is now one of the important parts in the building design, as increase in energy consumption and pollutant emission in energy conversion process. In this study, elements that affects the energy consumption of model building are identified and the perfomance analysis of the alternative a Low Energy Cooling Systems considering characteristics of model building and energy saving performance is analyzed. In this study, elements that affect the energy consumption of office building are identified and energy saving performance of the alternative air conditioning system is analyzed. As a result, applied to earn and suggest basic data for energy saving measures. In this study, EnergyPlus simulation program was used to evaluate the energy load when alternative Low Energy Cooling Systems are applied to the model building. The reliability of simulation program is verified by comparing actual energy load from operation data of building management office and predicted energy load using simulation program. For Low Energy Cooling System application which considers the purpose and characteristics of the building, reasonable and energy-saving air conditioning method obtained by analyzing energy consumption elements for each expected air conditioning methods is used to deduct result of this study.