• Title/Summary/Keyword: Method of Measurement

Search Result 15,838, Processing Time 0.053 seconds

The Acceptance Testing of 5 Mega Pixels Primary Electronic Display Devices and the Study of Quality Control Guideline Suitable for Domestic Circumstance (5 Mega 화소 진단용 전자표시장치 인수검사 및 국내 실정에 적합한 정도관리 가이드라인 연구)

  • Jung, Hai-Jo;Kim, Hee-Joung;Kim, Sung-Kyu
    • Progress in Medical Physics
    • /
    • v.18 no.2
    • /
    • pp.98-106
    • /
    • 2007
  • In June 2005, Yonsei University Medical Center, Severance Hospital upgraded a full-PACS system by adding twenty (5 mega pixels) Totoku ME511L flat panel LCD display devices for diagnostic interpretation purposes. Here we report upon the quantitative (or visual) acceptance testing of the twenty Totoku ME511L display devices for reflection, luminance response, luminance spatial dependency, resolution, noise, veiling glare, and display chromaticity based on AAPM TG 18 report. The tools used in the tests included a telescopic photometer, which was used as a colorimeter, illuminance meter, light sources for reflection assessment, light-blocking devices, and digital TG18 test patterns. For selected 8 flat panel displays, mean diffuse reflection coefficient ($R_d$) was $0.019{\pm}0.02sr^{-1}$. In the luminance response test, luminance ratio (LR), maximum luminance difference ($L_{max}$), and deviation of contrast response were $550{\pm}100,\;2.0{\pm}1.9%\;and\;5.8{\pm}1.8%$, respectively. In the luminance uniformity test, maximum luminance deviation was $14.3{\pm}5.5%$ for the 10% luminance of the TG18-UNL10 test pattern. In the resolution test with luminance measurement method, percent luminance (${\Dalta}L$) at the center was $0.94{\pm}0.64%$. In all cases of noise testing, rectangular target In every square in the three quadrants was visible and all 15 targets except the smallest one in the every corner pattern and the center pattern. The glare ratio (GR) was $12,346{\pm}1,995$. The color uniformity, (u',v'), was $0.0025{\pm}0.0008$. Also, the research results of qualify control guideline of primary disply devices suitable for domestic circumstance are presented All test results are in-line with the criteria recommended by AAPM TG18 report and are thus fully acceptable for diagnostic image interpretation. As a result, the acceptance testing schedule described provides not only an acceptance standard but also guidelines for quality control, optimized viewing conditions, and a means for determining the upgrading time of LCD display devices for diagnostic interpretation.

  • PDF

Production and Assessing Usefulness of the Moving Phantom for Respiration Gated Radiotherapy (호흡동조 방사선치료용 팬텀의 제작 및 유용성 평가)

  • Lee, Yang-Hoon;Lee, Jae-Hee;Yoo, Suk-Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.2
    • /
    • pp.135-144
    • /
    • 2010
  • Purpose: The purpose of this study is that through production of phantom for respiration gated radiotherapy, assessing appropriacy of exposure dose for the therapy using RPM (Real-time Position Management). Materials and Methods: We located measurement object on the phantom for respiration gated radiotherapy made of 2 linear actuator, acrylic panel, stanchion, iron plate ets. to drive (up, down, front, back). Using 4D CT scan, we analyzed patient's respiration and reproduced the movement by computer. On the phantom, we located a 2D-Array (PTW) and an White water phantom (4.5 cm) and used DMLC (interval 2 cm) in the field size $10{\times}10\;cm$, then exposed 21EX X-ray 100 MU, in the case of phantom was (1) static (2) moving (3) gated using RPM respectively gantry $0^{\circ}$ and $90^{\circ}$ We measured with a 0.125 CC ionization chamber (PTW) on the phantom (7.5 cm) in the same condition. Results: Ionization chamber: There were within 0.3% of error with gating respiration and approximately 2% of error without gating in the same condition. 2D-Array: Gantry $90^{\circ}$, field size $10{\times}10\;cm$, using DMLC. There were within 3% of error with gating respiration and approximately 16% of error without gating. Conclusion: The phantom for respiration gated radiotherapy makes plans considering patient's movement, quantitative analysis of exposure dose and proper assessment therapy for IMRT patients using RPM possible.

  • PDF

Evaluation of Basin-Specific CH4 emission flux from Intertidal Flat Sediments of Sogeun-ri, Taean, Mid-west Korea (한국 서해안 태안 소근리 갯벌의 메탄가스 발생량 특성)

  • Lee, Jun-Ho;Jeong, Kap-Sik;Woo, Han Jun;Kang, Jeongwon;Lee, Dong-Hun;Jang, Seok;Kim, Seong-Ryul
    • Journal of Wetlands Research
    • /
    • v.16 no.2
    • /
    • pp.281-291
    • /
    • 2014
  • In March to August 2013, the emission of gases ($CH_4$, VOC, $CO_2$, $O_2$, and LEL) was measured three times from the intertidal flat sediments at Sogeun-ri, Taean-gun, in the Mid-western seashore of Korea by using chamber method. After analyzing gas emission concentrations inside of flux enclosure chamber by using a GC equipped with Agilent 6890. The gas emission fluxes were calculated from a linear regression of the changes in the concentrations with time. The ranges of gas flux during the experimental period were $+0.06{\sim}+0.60mg/m^2/hr$ for $CH_4$, $+58.45{\sim}+95.58mg/m^2/hr$ for $CO_2$, $-0.02{\sim}-0.20mg/m^2/hr$ for $O_2$, and $-0.60{\sim}+0.65mg/m^2/hr$ for VOC, respectively. The flux measurement results revealed that $CH_4$ fluxes during March in the relatively low sediment temperature ($14.5^{\circ}C$) were significantly higher ($+0.60mg/m^2/hr$) than during June and August ($+0.06{\sim}+0.18mg/m^2/hr$) in high sediment temperature ($32.0{\sim}36.8^{\circ}C$). $CH_4$ flux to mean size of sediments and temperature of inner chamber exhibited strong positive correlation ($R^2=-0.97$ and $R^2=-0.89$, respectively).

Neuroprotective effects of Extract of Broccoli, Cultivated in Desalinated Magma Seawater, on neuron-like SH-SY5Y cells (제주도 탈염 용암해수 재배로 제조한 브로콜리 추출물의 신경 세포 보호 효과)

  • Rhee, Jin Seol;Jang, Youn Bi;Choi, Ge Sun;Choung, Jai Jun;Kang, Seung Woo
    • Journal of the Korean Applied Science and Technology
    • /
    • v.37 no.3
    • /
    • pp.448-462
    • /
    • 2020
  • Dietary nutrition is a critical lifestyle factor that can reduce the risk of future cognitive impairments caused by dementia. Accumulating evidence suggests that dietary supplementation with Sulforaphane may help the prevention of cognitive impairments and dementia. Thus, Sulforaphane-enriched broccoli extract would hold promise to improve cognitive impairments of dementia patients. Here, we have used broccoli extracts, prepared from broccoli cultivated in Magma Seawater, to test if the broccoli extracts can be dietary supplement to improve cognitive impairments. Magma Seawater originated from Jeju Island, Korea is unique in terms of containing high concentrations of usable minerals (Zinc, Vanadium and Germanium etc.). Broccoli, grown in Magma Seawater, would contain Sulforaphane and the extra amount of usable minerals. The chemical compositions of the broccoli extracts were analyzed using LC-Q-orbitrap to detect Sulforaphane and Glucoraphanin. Analysis method based on HPLC was developed for measurement of sulforaphane levels in the broccoli extracts. We have tested if the broccoli extracts have anti-apoptotic and anti-inflammatory effects on neuron-like SH-SY5Y cells. In addition, we examined if the broccoli extracts are able to upregulate expression of synaptic plasticity-associated proteins (BDNF and phospho-CREB) and to inhibit acetylcholine esterase (AchE) activity. We have shown that the broccoli extracts inhibited the apoptotic pathway and inflammatory responses. Finally, we present evidence showing that AchE activity was inhibited by the broccoli extracts, but expression of BDNF and phospho-CREB was upregulated. Taken together, these findings suggest that the broccoli extracts from Magma Seawater-grown broccoli would be a good source of dietary nutrition to improve cognitive impairments in the future.

Design and Implementation of Quality Broker Architecture to Web Service Selection based on Autonomic Feedback (자율적 피드백 기반 웹 서비스 선정을 위한 품질 브로커 아키텍처의 설계 및 구현)

  • Seo, Young-Jun;Song, Young-Jae
    • The KIPS Transactions:PartD
    • /
    • v.15D no.2
    • /
    • pp.223-234
    • /
    • 2008
  • Recently the web service area provides the efficient integrated environment of the internal and external of corporation and enterprise that wants the introduction of it is increasing. Also the web service develops and the new business model appears, the domestic enterprise environment and e-business environment are changing caused by web service. The web service which provides the similar function increases, most the method which searches the suitable service in demand of the user is more considered seriously. When it needs to choose one among the similar web services, service consumer generally needs quality information of web service. The problem, however, is that the advertised QoS information of a web service is not always trustworthy. A service provider may publish inaccurate QoS information to attract more customers, or the published QoS information may be out of date. Allowing current customers to rate the QoS they receive from a web service, and making these ratings public, can provide new customers with valuable information on how to rank services. This paper suggests the agent-based quality broker architecture which helps to find a service providing the optimum quality that the consumer needs in a position of service consumer. It is able to solve problem which modify quality requirements of the consumer from providing the architecture it selects a web service to consumer dynamically. Namely, the consumer is able to search the service which provides the optimal quality criteria through UDDI browser which is connected in quality broker server. To quality criteria value decision of each service the user intervention is excluded the maximum. In the existing selection architecture, the objective evaluation was difficult in subjective class of service selecting of the consumer. But the proposal architecture is able to secure an objectivity with the quality criteria value decision where the agent monitors binding information in consumer location. Namely, it solves QoS information of service which provider does not provide with QoS information sharing which is caused by with feedback of consumer side agents.

Development and Assessment of a Non-face-to-face Obesity-Management Program During the Pandemic (팬데믹 시기 비대면 비만관리 프로그램의 개발 및 평가)

  • Park, Eun Jin;Hwang, Tae-Yoon;Lee, Jung Jeung;Kim, Keonyeop
    • Journal of agricultural medicine and community health
    • /
    • v.47 no.3
    • /
    • pp.166-180
    • /
    • 2022
  • Objective: This study evaluated the effects of a non-face-to-face obesity management program, implemented during the pandemic. Methods: The non-face-to-face obesity management program used the Intervention mapping protocol (IMP). The program was put into effect over the course of eight weeks, from September 14 to November 13, 2020 in 48 overweight and obese adults, who applied to participate through the Daegu Citizen Health Support Center. Results: IMP was first a needs assessment was conducted; second, goal setting for behavior change was established; third, evidence-based selection of arbitration method and performance strategy was performed; fourth, program design and validation; fifth, the program was run; and sixth, the results were evaluated. The average weight after participation in the program was reduced by 1.2kg, average WC decreased by 3cm, and average BMI decreased by 0.8kg/m2 (p<0.05). The results of the health behavior survey showed a positive improvement in lifestyle factors, including average daily intake calories, fruit intake, and time spent in walking exercise before and after participation in the program. A statistically significant difference was seen (p<0.05). The satisfaction level for program process evaluation was high, at 4.57±0.63 point. Conclusion: The non-face-to-face obesity management program was useful for obesity management for adults in communities, as it enables individual counseling by experts and active participation through self-body measurement and recording without restriction by time and place. However, the program had some restrictions on participation that may relate to the age of the subject, such as skill and comfort in using a mobile app.

A Study on the Method for Quantifying CO2 Contents in Decarbonated Slag Materials by Differential Thermal Gravimetric Analysis (DTG 분석법을 활용한 슬래그류 비탄산염 재료의 CO2 정량 측정방법 연구)

  • Jae-Won Choi;Byoung-Know You;Yong-Sik Chu;Min-Cheol Han
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.12 no.1
    • /
    • pp.8-16
    • /
    • 2024
  • Limestone (CaCO3, calcium carbonate), which is used as a raw material in the portland cement and steel industry, emits CO2 through decarbonation by high temperatures in the manufacturing process. To reduce CO2 emissions by the use of raw materials like limestone, it has been proposed to replace limestone with various industrial by-products that contain CaO but less or none of the carbonated minerals, that cause CO2 emissions. Loss of Ignition (LOI), Thermogravimetric analysis (TG), and Infrared Spectroscopy (IR) are used to quantitative the amount of CO2 emission by using these industrial by-products, but CO2 emissions can be either over or underestimated depending on the characteristics of by-product materials. In this study, we estimated CO2 contents by LOI, TG, IR and DTG(Differential Thermogravimetric analysis) of calcite(CaCO3) and samples that contain CO2 in the form of carbonate and whose weight increases by oxidation at high temperatures. The test results showed for CaCO3 samples, all test methods have a sufficient level of reliability. On the other hand, for the CO2 content of the sample whose weight increases at high temperature, LOI and TG did not properly estimate the CO2 content of the sample, and IR tended to overestimate compared to the predicted value, but the estimated result by DTG was close to the predicted valu e. From these resu lts, in the case of samples that contain less than a few percent of CO2 and whose weight increases during the temperature that carbonate minerals decompose, estimating the CO2 content using DTG is a more reasonable way than LOI, TG, and IR.

The Effect of Photoneutron Dose in High Energy Radiotherapy (10 MV 이상 고에너지 치료 시 발생되는 광중성자의 영향)

  • Park, Byoung Suk;Ahn, Jong Ho;Kwon, Dong Yeol;Seo, Jeong Min;Song, Ki Weon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.1
    • /
    • pp.9-14
    • /
    • 2013
  • Purpose: High-energy radiotherapy with 10 MV or higher develops photoneutron through photonuclear reaction. Photoneutron has higher radiation weighting factor than X-ray, thus low dose can greatly affect the human body. An accurate dosimetric calculation and consultation are needed. This study compared and analyzed the dose change of photoneutron in terms of space according to the size of photon beam energy and treatment methods. Materials and Methods: To measure the dose change of photoneutron by the size of photon beam energy, patients with the same therapy area were recruited and conventional plans with 10 MV and 15 MV were each made. To measure the difference between the two treatment methods, 10 MV conventional plan and 10 MV IMRT plan was made. A detector was placed at the point which was 100 cm away from the photon beam isocenter, which was placed in the center of $^3He$ proportional counter, and the photoneutron dose was measured. $^3He$ proportional counter was placed 50 cm longitudinally superior to and inferior to the couch with the central point as the standard to measure the dose change by position changes. A commercial program was used for dose change analysis. Results: The average integral dose by energy size was $220.27{\mu}Sv$ and $526.61{\mu}Sv$ in 10 MV and 15 MV conventional RT, respectively. The average dose increased 2.39 times in 15 MV conventional RT. The average photoneutron integral dose in conventional RT and IMRT with the same energy was $220.27{\mu}Sv$ and $308.27{\mu}Sv$ each; the dose in IMRT increased 1.40 times. The average photoneutron integral dose by measurement location resulted significantly higher in point 2 than 3 in conventional RT, 7.1% higher in 10 MV, and 3.0% higher in 15 MV. Conclusion: When high energy radiotherapy, it should consider energy selection, treatment method and patient position to reduce unnecessary dose by photoneutron. Also, the dose data of photoneutron needs to be systematized to find methods to apply computerization programs. This is considered to decrease secondary cancer probabilities and side effects due to radiation therapy and to minimize unnecessary dose for the patients.

  • PDF

Effects of Packaging Materials and Storage Temperature on the Shelf-life of Korean Grinded Yam (포장재료와 보관온도에 따른 갈은 마의 저장수명 및 품질변화에 관한 연구)

  • Ko, Eui Suk;Won, Jong Hwa;Jin, Hyung Seok;Song, Kihyeon;Jeon, Kyu Bae;Kim, Jai Neung
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.20 no.3
    • /
    • pp.103-111
    • /
    • 2014
  • This study analyzed effects of packaging materials and storage temperature on the shelf-life of Korean grinded yam. For experimental measurement, experimental groups were used $PET(12{\mu}m)/Al(9{\mu}m)/LLDPE(60{\mu}m)$ as opaque barrier packaging material and $PET(12{\mu}m)/PE(20{\mu}m)/VM-PET(12{\mu}m)/PE(25{\mu}m$) and barrier $NY(15{\mu}m)/LLDPE(60{\mu}m$) as transparent barrier packaging material. Control group were used normal $NY(15{\mu}m)/LLDPE(65{\mu}m)$. The grinded yam stored at refrigeration temperature ($5^{\circ}C$) and room temperature ($20^{\circ}C$C) for 8 days. Changes in color, pH, viscosity, microorganisms and sensory characteristics were measured. In the grinded yam L and ${\Delta}E$ value were not changed rapidly at refrigeration temperature. However L and ${\Delta}E$ were rapidly changed in all of packaging materials at room temperature. In two temperature condition, pH and viscosity were decreased during storage but pH was increased at $5^{\circ}C$ after 4 days. PET/Al/LLDPE and PET/PE/VM-PET/PE inhibited the growth of microorganisms effectively. PET/AL/LLDPE which is a high barrier packaging material showed the best in two temperature condition.

  • PDF

A Localized Secular Variation Model of the Geomagnetic Field Over Northeast Asia Region between 1997 to 2011 (지역화된 동북아시아지역의 지구자기장 영년변화 모델: 1997-2011)

  • Kim, Hyung Rae
    • Economic and Environmental Geology
    • /
    • v.48 no.1
    • /
    • pp.51-63
    • /
    • 2015
  • I produced a secular variation model of geomagnetic field by using the magnetic component data from four geomagnetic observatories located in Northeast Asia during the years between 1997 and 2011. The Earth's magnetic field varies with time and location due to the dynamics of fluid outer core and the magnetic observatories on the surface measure in time series. To adequately represent the magnetic field or secular variations of the Earth, a spatio-temporal model is required. In making a global model, satellite observations as well as limited observatory data are necessary to cover the regions and time intervals. However, you need a considerable work and time to process a huge amount of the dataset with complicated signal separation procedures. When you update the model, the same amount of chores is demanded. Besides, the global model might be affected by the measurement errors of each observatory that are biased and the processing errors in satellite data so that the accuracy of the model would be degraded. In this study, as considered these problems, I introduced a localized method in modeling secular variation of the Earth's magnetic field over Northeast Asia region. Secular variation data from three Japanese observatories and one Chinese observatory that are all in the INTERMAGNET are implemented in the model valid between 1997 to 2011 with the interval of 6 months. With the resulting model, I compared with the global model called CHAOS-4, which includes the main, secular variation and secular acceleration models between 1997 to 2013 by using the three satellites' databases and INTERMAGNET observatory data. Also, the geomagnetic 'jerk' which is known as a sudden change in the time derivatives of the main field of the Earth, was discussed from the localized secular acceleration coefficients derived from spline models.