• Title/Summary/Keyword: Method of Measurement

Search Result 15,888, Processing Time 0.045 seconds

A new seat surface deformation measurement method for ergonomic seat evaluation (인간공학적 좌석평가를 위한 좌면 형상 변형측정에 관한 연구)

  • ;Saito, M.
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 1990.04a
    • /
    • pp.171-185
    • /
    • 1990
  • In order to measure the shape deformation of seat surfaces, an indentation measurement mat was devised. The 50cm * 50 cm mat containing small polyethylene beads were made using two sheets of polyurethane film. The indentation measurement mat was shaped by vacuuming between the subject and the testing seat. This method showed less than 5mm of deformation measurement error. Deformation of CADILLAC and MAXIMA seats were compared to demonstrate usefulness of the new method.

  • PDF

Implementation of Temperature Measurement System Using Fuzzy Theory (Fuzzy 이론을 이용한 디지털 온도계측 시스템의 구현)

  • Kang, Moon-Sung;Hong, Sung-Hun
    • Proceedings of the KIEE Conference
    • /
    • 1997.07b
    • /
    • pp.510-512
    • /
    • 1997
  • Measurement errors in a temperature measurement system are mainly due to the consisting elements' accuracies and the circuit parameters' changes following the environment variations such as temperature. Further, system's non-linearity makes the measurement accuracy worse, and accordingly a linearization method should be considered to avoid this worsening. In this study, an error-correction method and a linearization method are proposed and a system utilizing these methods is realized.

  • PDF

Analysis of Repeated Measurement Problem in SP data (SP 데이터의 Repeated Measurement Problem 분석)

  • CHO, Hye-Jin
    • Journal of Korean Society of Transportation
    • /
    • v.20 no.1
    • /
    • pp.111-119
    • /
    • 2002
  • One of the advantages of SP methods is the possibility of getting a number of responses from each respondent. However, when the repeated observations from each respondent are analysed by applying the simple modeling method, a potential problem is created because of upbiased significance due to the repeated observation from each respondent. This study uses a variety of approaches to explore this issue and to test the robustness of the simple model estimates. Among several different approaches, the Jackknife method and Kocurs method were applied. The Jackknife method was implemented using a program JACKKNIFE. The model estimate results of Jackknife method and Kocurs method were compared with those of the uncorrected estimates in order to test whether there was repeated measurement problem or not and the extent to which this problem affected the model estimates. The standard errors between the uncorrected model estimates and Jackknife estimates were also compared. The results reveals that the t-ratios of Kocurs are much lower than those of the uncorrected method and Jackknife estimates, indicating that Kocurs method underestimates the significance of the coefficients. Jackknife method produced the almost same coefficients as those of the uncorrected model but the lower t-ratios. These results indicate that the coefficients of the uncorrected method are accurate but that their significance are somewhat overestimated. In this study. 1 concluded that the repeated measurement Problem did exist in our data, but that it did not affect the model estimation results significantly. It is recommended that such a test should become a standard procedure. If it turns out that the analysis based on the simple uncorrected method are influenced by the repeated measurement problem. it should be corrected.

Aplication of the Thermodynamic Measurement Method for On-site Performance Evaluation of Hot Water Pumps Used in District Heating (지역난방 중온수 펌프의 현장 성능평가를 위한 열역학적 측정법 적용)

  • Park, Cheol Gyu;Yoo, Hoseon
    • Plant Journal
    • /
    • v.17 no.1
    • /
    • pp.50-57
    • /
    • 2021
  • It is very difficult to accurately calculate efficiency of each accessory device constituting the pump system and pump efficiency by the Conventional efficiency measurement method only. Therefore, this study introduced the lastest Thermodynamic pump efficiency measurement method in the district heating pump system for the first time in Korea. As a result, data uncertainty was high by the Conventional method, but the pump and Hydraulic Coupling efficiency values applied the Thermodynamic and Conventional method parallel measurement data were able to derive meaningful results that verified the reliability and adequancy of the pump performance measurement method by performing complementary roles. In additon, as a result of applying the Thermodynamic method to the distirct heating pump system, despite the high temperature environment of up to 120 ℃, it was possible to verify the reliability of the Thermodynamic method, such as high stable data mesurement, and durability of the measurement equipment.

Methods of A-weighted Sound Pressure Level Measurement for Fans and Blowers (KS B 6361, Focus on Revised Content made in 2000) (송풍기의 소음레벨 측정방법 (KS B6361, 2000년 개정내용을 중심으로))

  • Kim, Kyoung-Ho;Lee, Seung-Bae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.424-432
    • /
    • 2000
  • The revision was provided for the method of A-weighted sound pressure measurement for fans and blowers, in which the newly developed measurement techniques were applied to KS B 6361. This revision includes the sound power methods for radiated sound from the body, the in-duct measurement method, and the correction method for flow noise upon measuring microphone, etc.

  • PDF

Comparative Study for the Measurement of Fermoral Anteversion by Manual Method and Image Viewer (대퇴골 전염각 측정을 위한 수 작업 방법과 Image Viewer 방법과의 비교 연구)

  • Gwon, Dae-Cheol;Park, Beom
    • Journal of the Ergonomics Society of Korea
    • /
    • v.20 no.3
    • /
    • pp.27-35
    • /
    • 2001
  • The measurement of the fermoral anteversion is an important factor in the practice of orthopedic surgery. The anteversion is measured by means of the axis of head and neck of the femur. In this study. widely used computed tomography method of measuring anteversion was tested on femoral necks of patients. Measurement by the manual method and image viewer of computed tomography to determine the anteversion of femoral head were carried out on both femurs. In January and February 2001, 30 patients 3 to 6 years of age were randomly selected from Seoul National University Hospital. the purpose of this paper was to introduce a new method to measure femoral anteversion angle utilizing image viewer program. This new method was more accurate and convenient than the conventional manual method. No significant difference was observed between the manual method and the image viewer measurement of femoral anteversion. In conclusion, image viewer program was statistically more reliable in determining the angle of the fermoral anteversion.

  • PDF

Accuracy Improvement of Digital Measurement System by Modified Piecewise Measuring Functions (개선 구산 계측함수에 의한 디지털 계측시스템의 정밀도 향상)

  • Hong, Sung-Hun;Kang, Moon-Sung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.7 no.2
    • /
    • pp.138-145
    • /
    • 2001
  • Measurement errors in a digital measurement systems are mainly due to the consisting elements accuracies and the circuit parameters changes following the environment variations such as temperature. Further, systems non-linearity makes the measurement accuracy worse, and accordingly a linearization method should be considered to avoid this worsening. In this study, a temperature error-correction method and linearization methods are proposed and a digital temperature measurement system utilizing these methods is realized. And the proposed measurement methods are observed to increase the measurement accuracy of the digital measurement system.

  • PDF

Development of the Ultrasonic Method for Two-Phase Mixture Level Measurement

  • Lee, Dong-Won;No, Hee-Cheon;Song, Chul-Wha;Jeong, Moon-Ki
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1999.05a
    • /
    • pp.124-124
    • /
    • 1999
  • An ultrasonic method is developed for the measurement of the two-phase mixture level in the reactor vessel or steam generator. The ultrasonic method is selected among the several non¬nuelear two-phase mixture level measurement methods through two steps of selection procedure. A commercial ultrasonic level measurement method is modified for application into the high temperature, pressure, and other conditions. The calculation method of the ultrasonic velocity is modified to consider the medium as the homogeneous mixture of air and steam. and to be applied into the high temperature and pressure conditions. The cross-correlation technique is adopted as a detection method to reduce the effects of the attenuation and the dif.JUsed reflection caused by suface fluctuation. The waveguides are developed to reduce the loss of echo and to remove the effects of obstructs. The present experimental study shows that the developed ultrasonic method measures the two-phase mixture level more accurately than the conventional methods do.

  • PDF

Blood Pressure Measurement using the Modified Step-wise Deflation Method (개선된 계단 배기 방법을 이용한 혈압 측정)

  • Oh, Hong-Sic;Lee, Jong-Shill;Chee, Young-Joon;Kim, In-Young
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.5
    • /
    • pp.351-358
    • /
    • 2010
  • In the automatic non-invasive blood pressure measurement device, the oscillometric method iswidely used. In the oscillometric method, the step-wise deflation has the advantage of the robustness for the motion artifacts than the linear deflation method. But it has the disadvantage of its longer measurement time because we need to detect two or more pulses in a certain cuff pressure step. In this study, we suggest the modified step-wise deflation method to overcome this limitation while maintaining the general concept of step-wise deflation. Using one valid pulse in each step and the deflating valve control during the diastolic period, the measurement time could be reduced. In order to verify the accuracy of the proposed algorithm, we compared the blood pressure values from the suggested method and the blood pressure values from the conventional auscultation method. The mean and standard deviation were -0.50${\pm}$5.3mmHg and 2.08${\pm}$4.75mmHg, for systolic and diastolic blood pressure respectively. The measurement time can be reduced up to the half of conventional step-wise deflation method.

Hybrid Closed-Form Solution for Wireless Localization with Range Measurements (거리정보 기반 무선위치추정을 위한 혼합 폐쇄형 해)

  • Cho, Seong Yun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.7
    • /
    • pp.633-639
    • /
    • 2013
  • Several estimation methods used in the range measurement based wireless localization area have individual problems. These problems may not occur according to certain application areas. However, these problems may give rise to serious problems in particular applications. In this paper, three methods, ILS (Iterative Least Squares), DS (Direct Solution), and DSRM (Difference of Squared Range Measurements) methods are considered. Problems that can occur in these methods are defined and a simple hybrid solution is presented to solve them. The ILS method is the most frequently used method in wireless localization and has local minimum problems and a large computational burden compared with closed-form solutions. The DS method requires less processing time than the ILS method. However, a solution for this method may include a complex number caused by the relations between the location of reference nodes and range measurement errors. In the near-field region of the complex solution, large estimation errors occur. In the DSRM method, large measurement errors occur when the mobile node is far from the reference nodes due to the combination of range measurement error and range data. This creates the problem of large localization errors. In this paper, these problems are defined and a hybrid localization method is presented to avoid them by integrating the DS and DSRM methods. The defined problems are confirmed and the performance of the presented method is verified by a Monte-Carlo simulation.