• Title/Summary/Keyword: Method of Compliance

Search Result 883, Processing Time 0.028 seconds

Disease-related Knowledge Level and Compliance of Health Behavior in Patients with Myocardial Infarction According to the Atherosclerotic Risk Factors (심근 경색증 환자의 죽상경화증 위험요인별 질병관련 지식과 건강행위 이행)

  • Jeong, Hey-Sun
    • Korean Journal of Adult Nursing
    • /
    • v.13 no.4
    • /
    • pp.529-538
    • /
    • 2001
  • Purpose: This study purposed to examine the disease-related knowledge level and compliance with good health behavior in patients with myocardial infarction according to the atherosclerotic risk factors. Method: The subjects consisted of 72 patients with myocardial infarction and the data were collected by interviewing the subjects with questionnaires and reviewing their medical records from September, 15, 1999 to July 31, 2000. Data were analyzed using the SAS program. Results: 1) With regard to atherosclerotic risk factors: of the subjects, 91.7% lacked regular exercise, followed by smoking (61.1%). 2) The average knowledge score of the patients was 19.7 and the average compliance score was 53.9. 3) There were no significant differences in the total knowledge scores according to the patients' atherosclerotic risk factors. 4) Non-diabetics were significantly higher in knowledge scores on domain of risk factors than the diabetics. 5) The overweight patients were significantly higher in knowledge score on domain of nature of disease than the normalweight patients. 6) The total compliance scores of the non-smokers were significantly higher than those of the smokers. 7) The total compliance scores of the patients who do regular exercise were significantly higher than those of the patients who forgo regular exercise. 8) The non-smokers were significantly higher in compliance scores on domain of diet than the smokers. 9) The diabetic patients were significantly higher in compliance scores on domain of smoking cessation than the non-diabetics. 10) Patients who do regular exercise were significantly higher in compliance scores on other domains than the patients who forgo regular exercise. Conclusion: According to the above findings, it can be concluded that intensive nursing care and education should be provided to patients who have atherosclerotic risk factors such as smoking, hypertension, diabetes mellitus, lack of exercise, over weight, or hypercholesterolemia to increase disease related knowledge level and to improve compliance with good health behavior.

  • PDF

Evaluation of a Back Face Strain Compliance of CT specimen (CT시험편의 Back Face Strain Compliance 평가)

  • Kim, Won Beom
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.12
    • /
    • pp.686-691
    • /
    • 2016
  • In welded steel structures, there are many stress concentration sites such as weld beads, and welding defects are likely to occur at the welded parts. When a repeated fatigue load acts on a stress concentration site, fatigue crack occurs and propagates, leading to fatigue fracture. Therefore, it is necessary to understand fatigue life, crack initiation life, and crack propagation life in order to prevent fatigue failure. In this study, a compliance method was derived for use in the study of fatigue crack propagation characteristics. This compliance can be used for automated measurement of fatigue cracks. The compliance was calculated using an in-house FEM program for a CT specimen. The results of this calculation are presented in relation to a/W and compared with calculation results using the J integral and a program from a previous study. In addition, the strain distribution in the upward and downward directions was calculated from the center of the back face of the CT specimen. In this distribution, the strain tended to decrease from the center to the top and bottom. The compliance method was achieved from these calculations and can be used for automatic execution of crack propagation tests.

Analysis of a Planar 3 DOF RCC Mechanism using Prismatic Joint Compliances (미끄럼 관절 콤플라이언스를 활용한 평면형 3 자유도 RCC 메카니즘의 해석)

  • 김희구;김동국;이병주
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1994.10a
    • /
    • pp.611-616
    • /
    • 1994
  • Most of Commercial Remote Center Compliance(RCC) devices have been designed using deforma ble structures. In this work, we propose another type of assembly devices which generate the compliance effec ts by attaching the compliances (or spring) at the prismatic joints of the griven mechainsm. First, the kinematic analysis for a parallel-type planar 3-degree-of-freedom mechanism is performed using modified transfer method of generalized coordinate. Then, compliance characteristics for the mechanism using prismatic joint compliances are investigated. In particular, when the system maintains its symmetric configuration, the mechanism is show n to have RCC points at the center of the workspace. Finally, sensitivity analysis around RCC points is perfor med.

  • PDF

Design of a 6-axis Compliance Device with F/T Sensing for Position/Force Control (위치/힘 동시제어를 위한 F/T측정 기능을 갖는 6축 순응기구 설계)

  • Kim, Han Sung
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.21 no.2
    • /
    • pp.63-70
    • /
    • 2018
  • In this paper, the design of a novel 6-axis compliance device with force/torque sensing capability and the experiment results on force measurement are presented. Unlike the traditional control methods using a force/torque sensor with very limited compliance, the force control method employs a compliant device to provide sufficient compliance between an industrial robot and a rigid environment for more stable force control. The proposed compliance device is designed to have a diagonal stiffness matrix at the tip and uses strain gauge measurement which is robust to dust and oil. The measurement circuit is designed with low-cost IC chips however the force resolution is 0.04N.

Evaluation on fracture toughness of high frequency electric resistance welded steel pipe by unloading compliance method (고주파 전기저항 용접강관의 제하 컴플라이언스법에 의한 파괴인성 평가)

  • 오세욱;윤한기;안광주
    • Journal of Welding and Joining
    • /
    • v.5 no.2
    • /
    • pp.44-52
    • /
    • 1987
  • The fracture toughness, $J_{IC}$ of high frequency electric resistance welded steel pipe for smooth and side-grooved CT specimen was evaluated by unloading compliance method. The crack growth, .${\delta}a$ was obtained from the equation of Donald and Saxena & Hudak, and $J_{IC}$ was determined from the curve of J-${\delta}a$ relations. The crack growth on the experiment using unloading compliance method is underestimated as compared with ${\delta}a$ measured directly by the SEM, so the reliability of $J_{IC}$ from saxena & Hudak equation is large than that from Donald. The $J_{IC}$ value of side-grooved CT Specimen is estimated less than that of smooth, and this is the effect of the side-groove, the shear-lip of crack tip and the reduction of crack tunnelling phenomena.

  • PDF

Fracture Resistance Characteristics of SA516-Gr.70 Steel Plate for RCS Piping Elbow and Support Skirt (원자로 냉각재배관 엘보우 및 서포트 스컷트용)

  • Son, Jong-Dong;Lim, Man-Bae
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.4 s.76
    • /
    • pp.49-54
    • /
    • 2006
  • The evaluation of elastic-plastic fracture characteristic was investigated in ferrite steel SA 516- Gr70 used for reactor coolant piping elbow and support skirt of pressure vessels. This paper describes the effect of temperature on J-R curve characteristic of this material. The elastic-plastic fracture mechanics parameter J is obtained with unloading compliance method. The test method were analyzed according to ASTM E 813-89 and E 1152-89. Unloading compliance $J_{IC}$ tests were performed on 1 CT specimens at varied temperatures from $25^{\circ}C$ to about $400^{\circ}C$ using a high temperature extensometer. At all temperature, valid $J_{IC}$ measurements could be made and $J_{IC}$ decreased with increasing temperature. SEM fractography schematically illustrates microvoid initiation, growth and coalescence at the tip of a preexisting crack.

Crack Propagation at Boundary Face of Composite Compact Tension Specimen

  • Cho, Jae-Ung;Han, Moon-Sik
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.2
    • /
    • pp.337-341
    • /
    • 2013
  • In this study, fatigue crack propagation in composite material under fatigue is investigated by simulation result. When another material on the specimen exists vertically to the crack line, the phenomena that crack may go straight or propagate along the boundary face according to the elastic modulus ratio of another material to matrix are investigated with compact tension specimen by compliance method. Crack propagation direction is evaluated by compliance method. By arranging this study result systematically about the crack propagation behavior due to the stiffness of inhomogeneous material, high-tech material (automobile, aircraft and steel industry) can be improved. The estimation of safety design and life (construction & nuclear power station, etc.) will be of great value industrially.

Knowledge Level and Compliance of Health Behavior in Patients with Myocardial Infarction (심근 경색증 환자의 질병관련 지식과 건강행위 이행)

  • Jeong Hye-Sun;Yoo Yang-Sook
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.8 no.3
    • /
    • pp.334-345
    • /
    • 2001
  • Purpose : This study purposes to examine the knowledge level and compliance of health behavior in patients with myocardial infarction to develope a cardiac rehabilitation program. Method: The subjects consisted of 72 patients with myocardial infarction, hospitalized at three university-affiliated hospitals. The data were collected by interviewing their subjects using a questionnaire and reviewing the medical records from September 15, 1999 to July 31, 2000. Data were analyzed using the SAS program for Windows version 6.12. Results: 1 The average knowledge score of the patients was 19.7 and the average compliance score was 53.9. 2. Knowledge scores were highest in the items of avoiding overeating and taking medicine at prescribed dosage, and lowest in the item of when to avoid sexual activity. 3. Knowledge level were highest on domains of exercise & daily activities, and risk factors and followed by diet. medication. and nature of disease. 4. Those who had higher education, or were living with a spouse were significantly higher in knowledge score. 5. Compliance score was highest in the item of smoking cessation and lowest in the item of measuring heart rate regularly. 6. Compliance score was highest on domain of smoking cessation and followed by diet, exercise, others, and managing mental stress. 7. Female patients had significantly higher compliance scores of health behavior on domain of diet than male patients. 8. The knowledge score was positively correlated to compliance of health behaviors. Conclusion: According to the above findings, it can be concluded that intensive nursing care and education should be provided to the patients who have lower education or are living without a spouse. Also, nursing intervention should be developed to increase compliance of managing mental stress and doing regular exorcise.

  • PDF

Cryogenic Fracture Toughness Evaluation for Austenitic Stainless Steels by Means of Unloading Compliance Method

  • Yu, Hyo-Sun;Kwon, Il-Hyun
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.1
    • /
    • pp.26-34
    • /
    • 2001
  • Most research to date concerning the cryogenic toughness of austenitic stainless steels has concentrated on the base metal and weld metal in weldments. The most severe problem faced on the conventional austenitic stainless steel is the thermal aging degradation such as sensitization and carbide induced embrittlement. In this paper, we investigate the cryogenic toughness degradation which can be occurred for austenitic stainless in welding. The test materials are austenitic stainless JN1, JJ1 and JK2 steels, which are materials recently developed for use in nuclear fusion apparatus at cryogenic temperature. The small punch(SP) test was conducted to detect similar isothermally aging condition with material degradation occurred in service welding. The single-specimen unloading compliance method was used to determine toughness degradation caused by thermal aging for austenitic stainless steels. In addition, we have investigated size effect on fracture toughness by using 20% side-grooved 0.5TCT specimens.

  • PDF

Evaluation of the Crack Initiation of Curved Compact Tension Specimens of a Zr-2.5Nb Pressure Tube Using the Unloading Compliance and Direct Current Potential Drop Methods (제하 컴플라이언스법 및 직류전위차법을 이용한 Zr-2.5Nb 압력관 휘어진 CT 시편의 균열시작 평가)

  • Jeong, Hyeon-Cheol;Ahn, Sang-Bok;Kim, Young-Suk
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.8 s.239
    • /
    • pp.1118-1122
    • /
    • 2005
  • The direct current potential drop (DCPD) method and the unloading compliance (UC) method with a crack opening displacement gauge were applied simultaneously to the Zr-2.5Nb curved compact tension (CCT) specimens to determine which of the two methods can precisely determine the crack initiation point and hence the crack length for evaluation of their fracture toughness. The DCPD method detected the crack initiation at a smaller load-line displacement compared to the UC method. As a verification, a direct observation of the fracture surfaces on the curved compact tension specimens was made on the CCT specimens experiencing either 0.8 to 1.0 mm load line displacement or various loads from $50\%\;to\;80\%$ of the maximum peak load, or $P_{max}$. The DCPD method is concluded to be more precise in determining the crack initiation and fracture toughness, J in Zr-2.5Nb CCT specimens than the UC method.